1.
Int J Ophthalmol ; 6(5): 618-25, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24195036

RESUMO

AIM: To evaluate the accuracy of spherical equivalent (SE) estimates of a double-pass system and to compare it with retinoscopy, subjective refraction and a table-mounted autorefractor. METHODS: Non-cycloplegic refraction was performed on 125 eyes of 65 healthy adults (age 23.5±3.0 years) from October 2010 to January 2011 using retinoscopy, subjective refraction, autorefraction (Auto kerato-refractometer TOPCON KR-8100, Japan) and a double-pass system (Optical Quality Analysis System, OQAS, Visiometrics S.L., Spain). Nine consecutive measurements with the double-pass system were performed on a subgroup of 22 eyes to assess repeatability. To evaluate the trueness of the OQAS instrument, the SE laboratory bias between the double-pass system and the other techniques was calculated. RESULTS: The SE mean coefficient of repeatability obtained was 0.22D. Significant correlations could be established between the OQAS and the SE obtained with retinoscopy (r=0.956, P<0.001), subjective refraction (r=0.955, P<0.001) and autorefraction (r=0.957, P<0.001). The differences in SE between the double-pass system and the other techniques were significant (P<0.001), but lacked clinical relevance except for retinoscopy; Retinoscopy gave more hyperopic values than the double-pass system -0.51±0.50D as well as the subjective refraction -0.23±0.50D; More myopic values were achieved by means of autorefraction 0.24±0.49D. CONCLUSION: The double-pass system provides accurate and reliable estimates of the SE that can be used for clinical studies. This technique can determine the correct focus position to assess the ocular optical quality. However, it has a relatively small measuring range in comparison with autorefractors (-8.00 to +5.00D), and requires prior information on the refractive state of the patient.

2.
Optom Vis Sci ; 87(9): 675-81, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20581726

RESUMO

PURPOSE: To evaluate the intra- and intersession repeatability of the optical quality parameters provided by the Optical Quality Analysis System (OQAS), which is based on the double-pass technique. METHODS: We performed optical quality measurements using the OQAS on 20 eyes of 10 healthy subjects who had best spectacle-corrected visual acuity of 20/20 or better. Measurements were performed by the same examiner in three different sessions that were separated by 10-min intervals. The subject's eye was realigned at the beginning of each session. During each session, three consecutive measurements were taken without realignment. The following optical quality parameters were analyzed: the modulation transfer function cutoff frequency (MTFcutoff), the Strehl ratio, the OQAS values (OV) at contrasts of 100%, 20%, and 9%, and the objective scatter index (OSI). RESULTS: The mean coefficients of repeatability obtained for the first session were 4.51 (MTFcutoff), 0.049 (Strehl ratio), 0.15 (OV 100%), 0.21 (OV 20%), 0.28 (OV 9%), and 0.11 (OSI), which were similar to those found in the second and third sessions. The confidence limits in the Bland and Altman charts when the intrasession repeatability was assessed (in a comparison of the first and second measurements of the first session) ranged from -3.16 to 3.94 (MTFcutoff), -0.060 to 0.069 (Strehl ratio), -0.12 to 0.18 (OV 100%), -0.20 to 0.23 (OV 20%), -0.29 to 0.27 (OV 9%), and -0.12 to 0.13 (OSI). The same limits when the intersession repeatability was assessed (in a comparison of the first and second sessions) ranged from -5.30 to 5.49 (MTFcutoff), -0.054 to 0.050 (Strehl ratio), -0.17 to 0.17 (OV 100%), -0.22 to 0.19 (OV 20%), -0.26 to 0.29 (OV 9%), and -0.12 to 0.13 (OSI). CONCLUSIONS: Our findings showed that OQAS is a clinical instrument with a good intra- and intersession repeatability and that the realignment of the eye does not introduce any additional variability in the measurements.


Assuntos
Técnicas de Diagnóstico Oftalmológico/normas , Implante de Lente Intraocular , Avaliação de Resultados em Cuidados de Saúde/métodos , Avaliação de Resultados em Cuidados de Saúde/normas , Procedimentos Cirúrgicos Refrativos , Aberrometria/métodos , Aberrometria/normas , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...