Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
J. optom. (Internet) ; 17(3): [100491], jul.-sept2024. ilus, tab, graf
Artigo em Inglês | IBECS | ID: ibc-231873

RESUMO

Background and objectives: The invention described herein is a prototype based on computer vision technology that measures depth perception and is intended for the early examination of stereopsis. Materials and methods: The prototype (software and hardware) is a depth perception measurement system that consists on: (a) a screen showing stereoscopic models with a guide point that the subject must point to; (b) a camera capturing the distance between the screen and the subject's finger; and (c) a unit for recording, processing and storing the captured measurements. For test validation, the reproducibility and reliability of the platform were calculated by comparing results with standard stereoscopic tests. A demographic study of depth perception by subgroup analysis is shown. Subjective comparison of the different tests was carried out by means of a satisfaction survey. Results: We included 94 subjects, 25 children and 69 adults, with a mean age of 34.2 ± 18.9 years; 36.2 % were men and 63.8 % were women. The DALE3D platform obtained good repeatability with an interclass correlation coefficient (ICC) between 0.94 and 0.87, and coefficient of variation (CV) between 0.1 and 0.26. Threshold determining optimal and suboptimal results was calculated for Randot and DALE3D test. Spearman's correlation coefficient, between thresholds was not statistically significant (p value > 0.05). The test was considered more visually appealing and easier to use by the participants (90 % maximum score). Conclusions: The DALE3D platform is a potentially useful tool for measuring depth perception with optimal reproducibility rates. Its innovative design makes it a more intuitive tool for children than current stereoscopic tests. Nevertheless, further studies will be needed to assess whether the depth perception measured by the DALE3D platform is a sufficiently reliable parameter to assess stereopsis.(AU)


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto Jovem , Visão Binocular , Percepção de Profundidade , Visão Ocular , Testes Visuais
2.
J Optom ; 17(3): 100491, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38218113

RESUMO

BACKGROUND AND OBJECTIVES: The invention described herein is a prototype based on computer vision technology that measures depth perception and is intended for the early examination of stereopsis. MATERIALS AND METHODS: The prototype (software and hardware) is a depth perception measurement system that consists on: (a) a screen showing stereoscopic models with a guide point that the subject must point to; (b) a camera capturing the distance between the screen and the subject's finger; and (c) a unit for recording, processing and storing the captured measurements. For test validation, the reproducibility and reliability of the platform were calculated by comparing results with standard stereoscopic tests. A demographic study of depth perception by subgroup analysis is shown. Subjective comparison of the different tests was carried out by means of a satisfaction survey. RESULTS: We included 94 subjects, 25 children and 69 adults, with a mean age of 34.2 ± 18.9 years; 36.2 % were men and 63.8 % were women. The DALE3D platform obtained good repeatability with an interclass correlation coefficient (ICC) between 0.94 and 0.87, and coefficient of variation (CV) between 0.1 and 0.26. Threshold determining optimal and suboptimal results was calculated for Randot and DALE3D test. Spearman's correlation coefficient, between thresholds was not statistically significant (p value > 0.05). The test was considered more visually appealing and easier to use by the participants (90 % maximum score). CONCLUSIONS: The DALE3D platform is a potentially useful tool for measuring depth perception with optimal reproducibility rates. Its innovative design makes it a more intuitive tool for children than current stereoscopic tests. Nevertheless, further studies will be needed to assess whether the depth perception measured by the DALE3D platform is a sufficiently reliable parameter to assess stereopsis.

4.
Ophthalmol Ther ; 13(2): 509-527, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38113025

RESUMO

INTRODUCTION: There is growing evidence that confirms morphological changes in the posterior structures in patients with keratoconus (KC); however, isolated alterations could have been missed. This study assesses choroidal thickness (CT) in the fovea and beyond in KC eyes. METHODS: This prospective case-control and non-randomized study enrolled 107 eyes, 62 eyes of 62 patients with KC, and 45 age-matched eyes of 45 control subjects with axial length in the range of 22-26 mm. Swept-source optical coherence tomography (SS-OCT) was performed to manually measure the subfoveal choroidal thickness (SCT) using a single-line scan. CT was obtained automatically from the Early Treatment Diabetic Retinopathy Study (ETDRS) grid using the 12-lines radial scan pattern. A two-way repeated-measures analysis of variance (ANOVA) was conducted to evaluate CT variations among macular eccentricity, parafoveal area, and the interaction between both factors. CT was compared in all parafoveal areas between groups and subgroups of KC. RESULTS: SCT was significantly thicker in KC eyes (357 ± 57 µm) than in healthy eyes (325 ± 63 µm) (p < 0.001). Significant choroidal thickening was observed in the central ring and outer and inner rings of the temporal, superior, and inferior parafoveal macular areas (p < 0.001), except in the outer ring of the nasal macular zone (p > 0.05) of KC compared to healthy eyes. The CT significantly decreased from the center to the outer ring regardless of the presence of KC (p < 0.001). The choroid in the nasal macular zone was significantly thinner than that in the temporal, superior, and inferior parafoveal areas (p < 0.001). CONCLUSIONS: The choroidal structure increased its thickness not only in the subfoveal area, but also in eight parafoveal areas of the ETDRS grid encompassing a wider area of macular examination. These findings demonstrate and corroborate that keratoconus is not a purely corneal disease. Furthermore, it confirms the role that the choroidal structure has in the pathophysiology of keratoconus.

5.
J Clin Med ; 12(21)2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37959216

RESUMO

This systematic review investigates the prevalence and underlying causes of corneal edema following cataract surgery employing manual phacoemulsification. A comprehensive search encompassing databases such as PubMed, Embase, ProQuest, Cochrane Library, and Scopus was conducted, focusing on variables encompassing cataract surgery and corneal edema. Two independent reviewers systematically extracted pertinent data from 103 articles, consisting of 62 theoretical studies and 41 clinical trials. These studies delved into various aspects related to corneal edema after cataract surgery, including endothelial cell loss, pachymetry measurements, visual performance, surgical techniques, supplies, medications, and assessments of endothelial and epithelial barriers. This review, encompassing an extensive analysis of 3060 records, revealed significant correlations between corneal edema and endothelial cell loss during phacoemulsification surgery. Factors such as patient age, cataract grade, and mechanical stress were identified as contributors to endothelial cell loss. Furthermore, pachymetry and optical coherence tomography emerged as valuable diagnostic tools for assessing corneal edema. In conclusion, this systematic review underscores the link between corneal edema and endothelial cell loss in manual phacoemulsification cataract surgery. It highlights the relevance of factors like patient demographics and diagnostic modalities. However, further research is essential to unravel the complexities of refractive changes and the underlying mechanisms.

6.
Life (Basel) ; 13(11)2023 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-38004363

RESUMO

PURPOSE: Considering that peripheral corneal thinning occurs in keratoconus (KC), the anterior scleral thickness (AST) profile was measured to compare thickness variations in healthy and KC eyes across several meridians. METHODS: This cross-sectional case-control study comprised 111 eyes of 111 patients: 61 KC eyes and 50 age- and axial-length-matched healthy eyes. The AST was explored at three scleral eccentricities (1, 2, and 3 mm from the scleral spur) across four scleral zones (nasal, temporal, superior, and inferior) by using swept-source optical coherence tomography. The AST variations among eccentricities and scleral regions within and between groups were investigated. RESULTS: The AST significantly varied with scleral eccentricity in healthy eyes over the temporal meridian (p = 0.009), whereas in KC eyes, this variation was observed over the nasal (p = 0.001), temporal (p = 0.029) and inferior (p = 0.006) meridians. The thinnest point in both groups was 2 mm posterior to the scleral spur (p < 0.001). The sclera was thickest over the inferior region (control 581 ± 52 µm, KC 577 ± 67 µm) and thinnest over the superior region (control 448 ± 48 µm, KC 468 ± 58 µm) in both populations (p < 0.001 for all eccentricities). The AST profiles were not significantly different between groups (p > 0.05). The inferior-superior thickness asymmetry was statistically different 2 mm posterior to the scleral spur between groups (p = 0.009), specifically with subclinical KC (p = 0.03). There is a trend where the asymmetry increases, although not significantly, with the KC degree (p > 0.05). CONCLUSIONS: KC eyes presented significant thickness variations among eccentricities over the paracentral sclera. Although AST profiles did not differ between groups, the inferior-superior asymmetry differences demonstrated scleral changes over the vertical meridian in KC that need further investigation.

7.
Optom Vis Sci ; 100(12): 882-886, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37890116

RESUMO

SIGNIFICANCE: Some patients show poor visual outcomes after Descemet stripping automated endothelial keratoplasty. In such cases, secondary Descemet membrane endothelial keratoplasty can be performed to achieve complete visual recovery. Anterior segment optical coherence tomography (AS-OCT) is a valuable tool for the follow-up of posterior lamellar keratoplasty outcomes and complications. PURPOSE: This study aimed to report the clinical outcome of secondary Descemet membrane endothelial keratoplasty for managing poor visual results in a patient with graft failure after a previous Descemet stripping automated endothelial keratoplasty, highlighting the importance of AS-OCT in the follow-up of endothelial keratoplasty. CASE REPORT: A 38-year-old woman with high myopia underwent Descemet stripping automated endothelial keratoplasty for bullous keratopathy after explantation of an angle-supported phakic intraocular lens. Two years after keratoplasty, the patient experienced poor visual acuity (counting fingers), and significant corneal edema was observed on clinical examination hindering visualization of the anterior chamber structures. Anterior segment optical coherence tomography showed a failed and thickened graft adhering well to the recipient cornea in an anterior chamber without other comorbidities. Therefore, the graft was removed and replaced with a Descemet membrane endothelial keratoplasty graft without any complications. One year later, the clinical outcome was evaluated by comparing the pre-operative and post-operative best-corrected visual acuity, biomicroscopy findings, endothelial cell density, and corneal central thickness. CONCLUSIONS: Anterior segment optical coherence tomography is an important tool when deciding on the surgical technique to be applied and for the post-surgical monitoring of endothelial corneal grafts. This case demonstrates the successful management of Descemet stripping automated endothelial keratoplasty graft failure with Descemet membrane endothelial keratoplasty graft, highlighting the importance of AS-OCT in detecting complications such as graft dislocation and primary graft failure. In addition, corneal thickness measured using AS-OCT serves as a critical predictor of graft failure, as observed in this case.


Assuntos
Doenças da Córnea , Edema da Córnea , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Feminino , Humanos , Adulto , Doenças da Córnea/diagnóstico , Doenças da Córnea/etiologia , Doenças da Córnea/cirurgia , Endotélio Corneano , Tomografia de Coerência Óptica , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/efeitos adversos , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Acuidade Visual , Estudos Retrospectivos , Edema da Córnea/diagnóstico , Edema da Córnea/etiologia , Edema da Córnea/cirurgia , Lâmina Limitante Posterior
8.
Eur J Ophthalmol ; : 11206721231199121, 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37671407

RESUMO

PURPOSE: To demonstrate that intense pulsed light therapy (IPL) of the upper and lower eyelids with meibomian gland expression (MGX) is effective in improving dry eye disease due to meibomian gland dysfunction (MGD). METHODS: Patients with ocular discomfort (Ocular Surface Disease Index -OSDI- above 13) and signs of MGD were recruited. All patients underwent OSDI, visual acuity (VA), intraocular pressure, Schirmer test, meibography, non-invasive tear breakup time (NITBUT), slit-lamp examination (corneal and conjunctival staining, hyperemia, gland expressibility, and meibum quality), tear osmolarity and lipid layer thickness. IPL was performed with Optima IPL (Lumenis Ltd.) following a standardized protocol on upper and lower eyelids of both eyes, with inferior eyelid MGX. Patients received four sessions separated by two weeks each. Four weeks after, examinations were repeated. RESULTS: 160 patients (320 eyes) were included, of which 108 (67.5%) were women and mean age was 59.2 ± 15.08 (range 20-89). After four sessions, VA, OSDI, tear osmolarity, lipid layer thickness, NITBUT, hyperemia, corneal and conjunctival staining, gland expressibility, meibum quality, inferior eyelid Meiboscore and Schirmer test improved (all, p < 0.027). Changes in OSDI, initial and average NITBUT increased with dry eye disease severity (according to OSDI). Increased pre-treatment OSDI, hyperemia, corneal and conjunctival staining and Schirmer test were associated with an improvement in OSDI (all, p < 0.040). No adverse events were noted. CONCLUSIONS: The combination of IPL on upper and lower eyelids with MGX is safe and effective for the treatment of MGD. Patients with severe dry eye disease present greater improvements.

9.
Artigo em Inglês | MEDLINE | ID: mdl-37478724

RESUMO

In this work, a new approach for the identification of unknown compounds in human tears has been developed and validated using ultra-high performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS) linked to an intelligent data acquisition mode (AcquireX DS-dd-MS2) coupled to an automated data processing software (Compound Discoverer™ 3.2). As a pilot research study, four human tear samples from volunteers were analyzed. Data were acquired in both positive and negative ionization modes and exact mass, isotope pattern, and MS2 spectra match were used for the tentative identification. Following this approach, 58 substances were identified, 47 in positive mode and 11 in negative mode, with an estimated concentration ranging from 0.1 to 9000 ng mL-1. Most of them were amino acids, hormones, metabolites, and pharmaceuticals. In order to validate the proposed method, the system suitability was evaluated and 29 commercial analytical standards of the tentatively identified substances were analyzed, of which 28 were confirmed obtaining a high identification accuracy (96.6 %). These results confirm that the screening tool presented in this work can facilitate the discovery of new metabolites, novel potential biomarkers, and substances to which the person is exposed, such as pollutants.


Assuntos
Lágrimas , Humanos , Cromatografia Líquida de Alta Pressão/métodos , Projetos Piloto , Espectrometria de Massas/métodos
10.
Front Med (Lausanne) ; 10: 1157773, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37305138

RESUMO

Introduction: Glaucoma is a chronic neurodegenerative disease, which is the leading cause of irreversible blindness worldwide. As a response to high intraocular pressure, the clinical and molecular glaucoma biomarkers indicate the biological state of the visual system. Classical and uncovering novel biomarkers of glaucoma development and progression, follow-up, and monitoring the response to treatment are key objectives to improve vision outcomes. While the glaucoma imaging field has successfully validated biomarkers of disease progression, there is still a considerable need for developing new biomarkers of early glaucoma, that is, at the preclinical and initial glaucoma stages. Outstanding clinical trials and animal-model study designs, innovative technology, and analytical approaches in bioinformatics are essential tools to successfully uncover novel glaucoma biomarkers with a high potential for translation into clinical practice. Methods: To better understand the clinical and biochemical-molecular-genetic glaucoma pathogenesis, we conducted an analytical, observational, and case-comparative/control study in 358 primary open-angle glaucoma (POAG) patients and 226 comparative-control individuals (CG) to collect tears, aqueous humor, and blood samples to be processed for identifying POAG biomarkers by exploring several biological pathways, such as inflammation, neurotransmitter/neurotrophin alteration, oxidative stress, gene expression, miRNAs fingerprint and its biological targets, and vascular endothelial dysfunction, Statistics were done by using the IBM SPSS 25.0 program. Differences were considered statistically significant when p ≤ 0.05. Results: Mean age of the POAG patients was 70.03 ± 9.23 years, and 70.62 ± 7.89 years in the CG. Malondialdehyde (MDA), nitric oxide (NO), interleuquin (IL)-6, endothelin-1 (ET-1), and 5 hydroxyindolacetic acid (5-HIAA), displayed significantly higher levels in the POAG patients vs. the CG (p < 0.001). Total antioxidant capacity (TAC), brain derived neurotrophic factor (BDNF), 5-hydroxy tryptamine (5-HT), solute carrier family 23-nucleobase transporters-member 2 (SLC23A2) gene, and the glutathione peroxidase 4 (GPX4) gene, showed significantly lower levelsin the POAG patients than in the CG (p < 0.001). The miRNAs that differentially expressed in tear samples of the POAG patients respect to the CG were the hsa miR-26b-5p (involved in cell proliferation and apoptosis), hsa miR-152-3p (regulator of cell proliferation, and extracellular matrix expression), hsa miR-30e-5p (regulator of autophagy and apoptosis), and hsa miR-151a-3p (regulator of myoblast proliferation). Discussion: We are incredibly enthusiastic gathering as much information as possible on POAG biomarkers to learn how the above information can be used to better steer the diagnosis and therapy of glaucoma to prevent blindness in the predictable future. In fact, we may suggest that the design and development of blended biomarkers is a more appropriate solution in ophthalmological practice for early diagnosis and to predict therapeutic response in the POAG patients.

11.
Nutrients ; 15(5)2023 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-36904299

RESUMO

A prospective, randomized, single-center preliminary study was performed in patients with keratoconus stages I-III (Amsler-Krumeich), who received a high rich docosahexaenoic acid (DHA) (1000 mg/day) supplement for 3 months versus untreated patients. One eye per patient was evaluated. Thirty-four patients were recruited (75% men, mean age 31 years), with 15 randomized to the control group and 19 to the DHA-treated group. Corneal topography variables and plasma biomarkers of oxidative stress and inflammatory status were evaluated. A panel of fatty acids in blood samples was also assessed. There were significant between-group differences in the astigmatism axis, asphericity coefficient, and intraocular pressure in favor of the DHA group. Additionally, between-group significant differences in total antioxidant capacity (TAC), malondialdehyde (MDA), free glutathione (GSH) and GSH/GSSG ratio, as well as reduced values of inflammatory markers, including interleukin (IL)-4, IL-6, and vascular endothelial growth factor (VEGF-A) were found. These preliminary findings support the usefulness of the antioxidant and anti-inflammatory effects of DHA supplementation for targeting underlying pathophysiological mechanisms of keratoconus. Prolonged duration of DHA supplementation may be needed to detect more noticeable clinical changes in corneal topography.


Assuntos
Ácidos Docosa-Hexaenoicos , Ceratocone , Masculino , Humanos , Adulto , Feminino , Ácidos Docosa-Hexaenoicos/farmacologia , Antioxidantes , Triglicerídeos , Fator A de Crescimento do Endotélio Vascular , Ceratocone/tratamento farmacológico , Estudos Prospectivos , Suplementos Nutricionais , Glutationa/metabolismo , Anti-Inflamatórios/uso terapêutico
12.
Vision (Basel) ; 7(1)2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36649052

RESUMO

Digital asthenopia (DA) or Computer Vision Syndrome can occur after prolonged use of digital devices and is usually managed with ergophthalmological measures and the use of artificial tears. This prospective, controlled study evaluated the use of hyaluronic acid artificial tears on the signs and symptoms of DA in participants of a videogame convention. Subjects (n = 56) were randomized into a control group (CG, n = 26), which followed ergophthalmological measures, and a study group (SG, n = 30), which followed ergophthalmological measures and instilled 1 drop of artificial tears with hyaluronic acid 0.15% four times a day. Subjects were evaluated before and after playing for three consecutive days for eye dryness (SPEED questionnaire), conjunctival hyperemia, corneal fluorescein staining, conjunctival lissamine green staining, tear breakup time, Schirmer I test, near convergence and accommodation, and using questionnaires for DA symptoms. After 3 days of intense videogaming, the SPEED score of CG increased significantly (p = 0.0320), while for the SG it was unchanged. Similarly, the CG presented significant increases in ocular fatigue (p = 0.0173) and dryness (p = 0.0463), while these parameters decreased significantly in the SG (p = 0.0149 and p = 0.00427, respectively). This study confirms the protective effect of hyaluronic acid artificial tears against DA symptoms associated with prolonged visual display terminal use.

13.
Eur J Ophthalmol ; 33(4): NP13-NP18, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35435049

RESUMO

PURPOSE: Descemet´s membrane ruptures (with a discontinuation of Descemet´s membrane and double detached coiled edges) in the context of complicated anterior segment surgery have rarely been described and its management can be challenging. We report a modified Descemet stripping only (DSO) technique associated with ripasudil drops to treat these cases when other techniques fail. METHODS: We describe two cases of large Descemet´s membrane detachments associated with Descemet´s ruptures after cataract surgery that did not respond to two SF6 intracameral injections. As the detached Descemet's membrane and coiled edges might have prevented endothelial cell migration, we decided to perform a modified DSO with post-operative ripasudil drops to promote corneal clearance. RESULTS: Both cases improved significantly in unaided and best corrected visual acuity (BCVA), corneal clearance and pachymetry, avoiding the need for an endothelial keratoplasty. Endothelial cells were observed on specular microscopy within the area of the descemetorhexis. CONCLUSION: DSO with ripasudil drops might be a valuable tool to recover corneal clearance and avoid endothelial keratoplasty in complex Descemet´s membrane detachments with ruptures that do not respond to other treatments.


Assuntos
Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs , Humanos , Distrofia Endotelial de Fuchs/cirurgia , Lâmina Limitante Posterior/cirurgia , Endotélio Corneano/cirurgia , Acuidade Visual , Células Endoteliais , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos
14.
J Cataract Refract Surg ; 49(2): 177-183, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36255227

RESUMO

PURPOSE: To assess the effects of cataract surgery on the spontaneous blinking pattern and blinking kinematics. SETTING: FISABIO Oftalmología Médica Eye Hospital, Valencia, Spain. DESIGN: Observational descriptive clinical study. METHOD: Patients with senile cataract were evaluated before (visit 1) and at 1 month (visit 2) and 3 months (visit 3) after undergoing phacoemulsification cataract surgery. The blinking of patients was recorded for 90 seconds using an eye-tracking device. Blinks were analyzed by means of image analysis to obtain a noninvasive detailed description of blinking including blink rate, number of complete and incomplete blinks, percentage of incomplete blinks, and kinematic parameters, including amplitude, closing, contact, opening, and total durations and closing and opening speeds. RESULTS: 50 patients were included in this study. The blink rate was significantly smaller at visit 3 compared with baseline ( P = .03) and visit 2 ( P = .001). Likewise, the number of complete blinks was significantly smaller, and the percentage of incomplete blinks was significantly higher at 3 months postoperatively compared with baseline ( P = .02 and P = .01, respectively), although no differences were observed at 1 month postoperatively ( P > .05). Conversely, no differences in the number of incomplete blinks or any kinematic parameter were observed between visits ( P = .12). CONCLUSIONS: Cataract surgery significantly altered the blinking pattern at 3 months postoperatively, although kinematic parameters remained unvaried. Clinicians should be aware of potential alterations in blinking after phacoemulsification cataract surgery and the implications this may have on the ocular surface of patients.


Assuntos
Catarata , Oftalmologia , Humanos , Piscadela , Pálpebras , Fenômenos Biomecânicos
15.
Ophthalmic Res ; 65(6): 685-697, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35835082

RESUMO

INTRODUCTION: This study aimed to assess anterior scleral thickness (AST) across diverse scleral meridians and to evaluate the relationship with corneal biomechanical response and several ocular parameters. METHODS: This prospective nonrandomized study comprised 50 eyes of 50 patients (mean age, 29.02 ± 9.48 years). AST was measured meridionally at three scleral locations (1, 2, and 3 mm posterior to the scleral spur) using swept-source optical coherence tomography. A multivariate model was created to associate AST with several ocular parameters. Principal component analysis (PCA) was used to reduce linearly the dimensionality of seven biomechanical input metrics to two significant components, C1 and C2. Two multivariate analyses were performed to associate C1 and C2 with AST and ocular parameters. RESULTS: AST was thickest in the inferior (581 ± 52 µm) and thinnest in the superior meridian (441 ± 42 µm) when compared to all meridians (p < 0.001) and similar in the nasal (529 ± 53 µm) and temporal (511 ± 59 µm) meridians (p > 0.05). The sclera exhibited the thinnest point 2 mm posterior to the scleral spur (p < 0.001). The AST was significantly linked with axial length, central corneal thickness, and intraocular pressure (p < 0.001). The PCA showed that C1 accounts for 53.84%, whereas C2 for the 16.51% of the total variance in the original variables. The C1 model was significantly associated with AST along all meridians (p < 0.001). The partial correlation was moderate in the nasal (r = -0.36, p < 0.001) and inferior (r = -0.26, p = 0.004) meridians, whereas weak in the temporal (r = -0.14, p = 0.05) and superior (r = -0.15, p = 0.05) meridians. CONCLUSIONS: The relationship between the new biomechanical component and the AST provides the first evidence of the association of AST with the corneal response parameters which should be considered in corneal response interpretation. Tissue thickness varied significantly among meridians supporting the asymmetrical expansion of the ocular globe. The AST was associated with several ocular parameters.


Assuntos
Córnea , Esclera , Adulto , Humanos , Adulto Jovem , Estudos Prospectivos , Fenômenos Biomecânicos
16.
BMC Ophthalmol ; 22(1): 242, 2022 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-35655163

RESUMO

BACKGROUND: To assess visual quality and stabilization of refractive changes in corneal edema patients after cataract surgery, using visual acuity (VA) and contrast sensitivity measurements. METHODS: Sixty-one eyes were analysed, twenty-three with and thirty-eight without corneal edema. Uncorrected and corrected distance VA (UDVA and CDVA) were determined with an EDTRS chart, the contrast sensitivity function (CSF) under photopic and mesopic illumination conditions with a CVS-1000e chart, clinical refraction, and corneal topography. Measurements were taken preoperatively, 1-2 days, 1 and 3-months after surgery. Clinical refraction was converted to vector notation (M, J0, J45) and SPSS v26.0 was used for data analysis. RESULTS: An improvement of VA was observed through the postoperative period; changes between visits were significant for CDVA in both groups and for UDVA in the edema sample. Significant astigmatic changes (J0,J45) between visits were not observed, but M values showed a hyperopic tendency in the edema group and a myopic shift in the control group that did not change between visits, with statistically significant differences between groups. Controls had significantly better contrast sensitivity at high spatial frequencies. Under mesopic conditions, global contrast sensitivity losses were observed in the edema group, which improved between visits in the middle frequency range. CONCLUSION: Corneal edema patients had a significant reduction of CDVA, and frequency-selective sensitivity losses that evidence a visual quality loss. Clinical refraction may improve visual quality, but in edema patients these losses are related to corneal changes, which did not change at three months after surgery.


Assuntos
Catarata , Edema da Córnea , Córnea , Edema da Córnea/etiologia , Edema , Humanos , Refração Ocular
17.
Toxics ; 9(11)2021 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-34822665

RESUMO

The detection of SARS-CoV-2 in indoor environments is a cause of increasing concern. In this study, three sampling methodologies have been used in order to collect SARS-CoV-2 and 17 other respiratory viruses in indoor air, combined with a new analytical process to analyze respiratory viruses. Different areas of an ophthalmological hospital were investigated for the presence of these airborne viruses. Moreover, indoor air quality (IAQ) parameters (carbon dioxide, CO2; carbon monoxide, CO; nitrogen dioxide, NO2; volatile organic compounds, VOCs; formaldehyde, HCHO; and particulate matter, PM) have been examined to study the relationship between IAQ and airborne viruses. All indoor air and surface samples assessed were found to be negative for SARS-CoV-2. Nevertheless, another airborne respiratory virus (HRV/ENV) was detected, illustrating that the methodology set out here is a suitable one. Regarding the results for the IAQ, chemical parameters studied in the hall and waiting room of the hospital presented acceptable values. However, in the doctor's consultation room VOCs and HCHO show some instantaneous levels higher than the recommended guide values. The methodological approach described in this paper, integrating conventional IAQ and the assessment of bioaerosols, can be used in research and control programs aimed at promoting a healthy indoor environment.

18.
J Clin Med ; 10(19)2021 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-34640506

RESUMO

We have assessed the spectral transmittance of the different layers of the human cornea in the ultraviolet (UV), visible, and near-infrared (IR) spectral ranges. Seventy-four corneal sample donors were included in the study. Firstly, the corneal transmittance was measured using a spectrophotometer. Then, all samples were fixed for histopathological analysis, which allowed us to measure the thickness of each corneal layer. Finally, the absorption coefficients of the corneal layers were computed by a linear model reproducing total transmittance. The results show that corneal transmission was almost in unity at the visible and IR ranges but not at the UV range, in which the layer with higher transmission is Descemet's membrane, whereas the stroma showed the lowest transmittance. Regarding the absorption coefficient, the most absorptive tissue was Bowman's layer, followed by the endothelium. Variations on transmittance due to changes in the stroma, Bowman's layer, or Descemet layer were simulated, and important transmission increases were found due to stroma and Bowman changes. To conclude, we have developed a method to measure the transmittance and thickness for each corneal layer. All corneal layers absorb UV light to a greater or lesser extent. The absorption coefficient is higher for Bowman's layer, while the stroma is the layer with the lowest transmittance due to its thickness. Variations in stroma thickness or changes in the corneal tissue of Bowman's layer or the endothelium layer due to some pathologies or surgeries could affect, to a greater or lesser degree, the total transmission of the cornea. Thus, obtaining accurate absorption coefficients for different layers would help us to predict and compensate these changes.

19.
Int J Ophthalmol ; 14(9): 1371-1383, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34540613

RESUMO

AIM: To evaluate the short-term clinical outcomes of Ferrara rings in keratoconus using an optimized nomogram developed after several years of research and retrospective analysis of clinical data. METHODS: This prospective longitudinal non-comparative clinical trial evaluated 88 eyes of 88 patients (age 18-62y) with keratoconus diagnosis from two Spanish centers. Ferrara ring segment (AJL Ophthalmic) implantation was performed in all cases, using the mechanical procedure in 25 eyes (28.4%) and a femtosecond laser-assisted procedure in 63 eyes (71.6%). The ring segments implanted in each case were selected using a new optimized nomogram that considered variables such as anterior corneal asphericity and astigmatism or the discrepancy among astigmatism and coma orientations. Visual, refractive, corneal topographic, aberrometric, and pachymetric changes after surgery were evaluated during a 3-month follow-up. RESULTS: The implants induced a significant refractive change as well as an improvement in uncorrected (UDVA) and corrected distance visual acuity (CDVA; P<0.001). Postoperative CDVA of 0.10 logMAR or better was achieved in 28.4% and 46.5% of eyes, respectively. Two eyes (2.3%) lost two or more lines of CDVA whereas a total of 53.5% of eyes gained lines of CDVA. A significant central anterior and posterior corneal flattening was induced (P≤0.003), with a significant reduction of anterior (P<0.001) and posterior corneal astigmatisms (P=0.048), and a change in anterior asphericity (P<0.001). Total primary coma (6 mm pupil) change was also statistically significant (preoperative 3.66±3.04 µm vs postoperative 2.33±2.26 µm, P<0.001). No significant differences were found in the effect of ring segments between cases implanted using the mechanical and femtosecond techniques (P≥0.101). CONCLUSION: The implantation of Ferrara rings based on the nomogram evaluated is safe and effective for promoting a visual rehabilitation in keratoconus, with a relevant control of primary coma aberration.

20.
J Clin Med ; 10(16)2021 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-34441869

RESUMO

This non-comparative prospective case series was conducted to characterize the clinical impact of intense pulsed light (IPL)-based treatment in dry eyes associated to Meibomian gland dysfunction (MGD), defining the predicting factors for a successful outcome with this therapy in a large case series. A total of 390 eyes (195 patients, range: 23-93 years) received four sessions of Optima IPL system (Lumenis, Yokneam, Israel). Significant changes were observed in tear film osmolarity in both eyes (p < 0.001) and in meibum quality (p < 0.001), with more eyes showing clear or yellow secretions after therapy. Mean change in the ocular surface disease index (OSDI) was -8.61, ranging from -27.00 to 11.00. This change was significantly correlated with the baseline value of OSDI (r = -0.489, p < 0.001). The change in osmolarity correlated significantly with the baseline osmolarity in both eyes (right r = -0.636, left r = -0.620, p < 0.001). A linear predicting model of the change in OSDI with therapy was obtained: change OSDI = 10.99 - 0.35 × OSDI - 1.03 × NIBUTRE-LE (mean non-invasive break up time of right and left eye) - 2.03 × Meibum quality grade (p = 0.001; R2: 0.325). In conclusion, the improvement in symptomatology achieved with an IPL-based therapy can be predicted at baseline using a linear model considering the level of MGD and the magnitude of OSDI and NIBUT (non-invasive break-up time).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...