Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38076031

RESUMO

This study characterizes the effects of three commonly detected pharmaceuticals-diclofenac, erythromycin, and gemfibrozil-on aerobic granular sludge. Approximately 150 µg/L of each pharmaceutical was fed in the influent to a sequencing batch reactor for 80 days, and the performance of the test reactor was compared with that of a control reactor. Wastewater treatment efficacy in the test reactor dropped by approximately 30-40%, and ammonia oxidation was particularly inhibited. The relative abundance of active Rhodocyclaceae, Nitrosomonadaceae, and Nitrospiraceae families declined throughout exposure, likely explaining reductions in wastewater treatment performance. Pharmaceuticals were temporarily removed in the first 12 days of the test via both sorption and degradation; both removal processes declined sharply thereafter. This study demonstrates that aerobic granular sludge may successfully remove pharmaceuticals in the short term, but long-term tests are necessary to confirm if pharmaceutical removal is sustainable.

2.
Water Air Soil Pollut ; 233(12)2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36504545

RESUMO

Environmental contamination from pharmaceuticals has received increased attention from researchers in the past 20 years. As such, numerous lab-scale studies have sought to characterize the effects of these contaminants on various targets, as well as determine improved removal methods. Many studies have used lab-scale bioreactors to investigate pharmaceutical effects on wastewater bacteria, as wastewater treatment plants often act as reservoirs for pharmaceuticals. However, few-if any-of these studies report the specific lab materials used during testing, such as tubing or pipette tip type. In this study, the pharmaceuticals erythromycin, diclofenac, and gemfibrozil were exposed to different micropipette tips, syringe filters, and tubing types, and losses over time were evaluated. Losses to tubing and syringe filters were particularly significant and neared 100%, depending on the pharmaceutical compound and length of exposure time. Results discussed herein indicate that pharmaceutical sorption to various lab supplies results in decreases to both dosed and quantified pharmaceutical concentrations. Studies that fail to consider this source of loss may therefore draw inaccurate conclusions about pharmaceutical effects or removal efficiencies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...