Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Stud Health Technol Inform ; 216: 842-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26262170

RESUMO

The rapid migration of health care from the institution to the home presents a plethora of consumer health technology options.. The fit of these technologies to the users' actual task performance and environment remains to be explored. In the vizHOME study, we set out to conduct in-depth analyses of health information management tasks conducted by individuals residing in 20 homes in the Midwestern United States who self-reported with diabetes. This paper will explore early results from five of the 13 assessments we have performed to-date. Early observations are described and implications for informatics are posited.


Assuntos
Serviços de Assistência Domiciliar , Informática Médica , Autocuidado , Adulto , Idoso , Automonitorização da Glicemia , Diabetes Mellitus/terapia , Características da Família , Feminino , Humanos , Entrevistas como Assunto , Masculino , Conduta do Tratamento Medicamentoso , Pessoa de Meia-Idade , Wisconsin , Adulto Jovem
2.
Hum Factors ; 48(3): 574-86, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17063970

RESUMO

OBJECTIVE: Two experiments were conducted to examine the effects of vision and masking friction on contact perception and compliance differentiation thresholds in a simulated tissue-probing task. BACKGROUND: In minimally invasive surgery, the surgeon receives limited haptic feedback because of the current design of the instrumentation and relies on visual feedback to judge the amount of force applied to the tissues. It is suggested that friction forces inherent in the instruments contribute to errors in surgeons' haptic perception. This paper investigated the psychophysics of contact detection and cross-modal sensory processing in the context of minimally invasive surgery. METHOD: A within-subjects repeated measures design was used, with friction, vision, tissue softness, and order of presentation as independent factors, and applied force, detection time, error, and confidence as dependent measures. Eight participants took part in each experiment, with data recorded by a custom force-sensing system. RESULTS: In both detection and differentiation tasks, higher thresholds, longer detection times, and more errors were observed when vision was not available. The effect was more pronounced when haptic feedback was masked by friction forces in the surgical device (p < .05). CONCLUSION: Visual and haptic feedback were equally important for tissue compliance differentiation. APPLICATION: A frictionless endoscopic instrument can be designed to restore critical haptic information to surgeons without having to create haptic feedback artificially.


Assuntos
Tecido Conjuntivo , Tato , Interface Usuário-Computador , Percepção Visual , Adulto , Feminino , Cirurgia Geral/métodos , Humanos , Masculino , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA