Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 79: 264-272, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34656714

RESUMO

BACKGROUND: There is no consensus on the method of obtaining abdominal aortic aneurysm (AAA) maximum diameters based on computed tomographic angiography, and the reproducibility and accuracy of different methods have recently been debated due to advancements in imaging. This study compared the two most common methods based on orthogonal planes and centerline of flow to determine the discordances and accuracy amongst experiences readers. METHODS: The computed tomographic angiography max diameters of 148 AAAs were measured by three experienced observers, including a vascular surgeon, a radiologist and an imaging cardiologist. Observers used two different methods with standardized protocols: multiplanar reformations based on orthogonal planes, and a software using 3D aortic reconstructions to create centerline flow lumen providing diameters based on cross sections perpendicular to this lumen. Agreements and reliability of measurement methods were assessed by intra-class correlation coefficient and Bland - Altman analysis. Discordances between measurements of the methods and the original reported measurement, as well as outside hospitals were compared. RESULTS: The average age of the cohort was 75 years and aortic diameters ranged from 3.8 to 9.6 cm. For orthogonal readings, there were agreements within 3 mm between 86% and 92% of the time, while centerline - reading agreement was between 88% and 94%, which was not statistically significant. The intra-class correlation coefficient was high between method type and between readers. Within methods, agreement was between 0.96 and 0.97, while within - reader agreement measures was between 0.96 and 0.98. In comparison to the original and the outside hospital reports, 10% ≥ of the original and 20% ≥ of the outside hospital reported measurements were discordant between the readers. CONCLUSION: Maximal AAA measurements can have substantial variability leading to clinical significance and change in patient management and outcomes. Based on the results, orthogonal and centerline measurement methods have equally high agreements and concordance within 3 mm and low variations at a high volume center. However, when compared to the official read reports, there is high discordance rates that can significantly alter patient outcomes. A standardized method of measurement maximum diameter can reduce variations and discordances among different methods.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/normas , Angiografia por Tomografia Computadorizada/normas , Idoso , Idoso de 80 Anos ou mais , Dilatação Patológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
J Vasc Surg Cases Innov Tech ; 3(3): 175-179, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29349413

RESUMO

Hemodialysis Reliable Outflow (HeRO) grafts (Merit Medical Systems, Inc, South Jordan, Utah) provide a means for access in catheter-dependent hemodialysis patients but typically require several weeks for tissue incorporation. Modifying the HeRO graft with an ACUSEAL graft (W. L. Gore & Associates, Newark, Del) can allow immediate cannulation, thus reducing catheter dependence time and its associated complications. A retrospective review of patients at our institution from 2013 to 2016 who underwent placement of a modified HeRO dialysis system with ACUSEAL graft was performed. Complications and outcomes were analyzed, with patency rates and hours to successful cannulation being major end points. Modified HeRO grafts were successfully placed in 10 catheter-dependent patients. Postoperative complications included two thromboses and one hematoma. At 6 months of follow-up, mean time to graft cannulation was 33.7 hours, with 100% success; the primary and secondary patency rates were 70% and 90%, respectively. Our modification allows an accelerated use of the HeRO system, reducing catheter dependence time with acceptable postoperative complications and patency rates.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...