Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
2.
Clin Oral Investig ; 28(7): 372, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38872049

RESUMO

OBJECTIVES: Bioactive surfaces were designed to increase the interaction between the surface and the cells. This may speed up the biological stability and loading protocols. MATERIALS AND METHODS: 36 patients with D3-D4 bone density were recruited and allocated into two groups. 30 bioactive (test group) and 30 traditional (control group) surfaced implants were placed. Insertion torque value (Ncm), insertion torque curve integral (cumulative torque, Ncm), torque density (Ncm/sec), implant stability quotient (ISQ) measured at three timepoints (baseline (T0), 30 (T30) and 45 (T45) days after surgery), and marginal bone loss (MBL) at 6 months of loading were assessed. RESULTS: The mean ISQ and standard deviation at T0, T30, T45 were respectively 74.57 ± 7.85, 74.78 ± 7.31, 74.97 ± 6.34 in test group, and 77.12 ± 5.83, 73.33 ± 6.13, 73.44 ± 7.89 in control group, respectively. Data analysis showed significant differences between groups in ΔISQ at T0-T30 (p = 0.005) and T30-T45 (p = 0.012). Control group showed a significant decrease in ISQ at T30 (p = 0.01) and T45 (p = 0.03) compared to baseline, while no significant change was observed in test group. Due to the stability of the ISQ value ≥ 70, 26 test group and 23 control group implants were functionally loaded after 45 days. Conversely, due to the ISQ < 70 at T45, four test group implants and one control group implant were loaded after 90 days, and 6 control group implants were loaded after 180 days. Neither insertion torque nor ISQ at baseline were correlated with bone density (in Hounsfield units). There was no significant correlation between cumulative torque and ISQ at baseline. There was a significant positive slope in the correlation between torque density and ISQ at baseline, more accentuated in D3 than D4. This correlation remained significant for the test group in D3 bone at day 30 and 45 (p < 0.01 in both time frames), but not in D4 bone, and it was not significant in CG. CONCLUSIONS: The bioactive surface showed better behavior in terms of implant stability in D3-D4 bone quality in the early stages of bone healing. Clinical relevance This study demonstrated that the transition from primary to secondary stability is improved using bioactive surface, especially in cases of poor bone environment (D3/D4 bone).


Assuntos
Densidade Óssea , Implantação Dentária Endóssea , Implantes Dentários , Propriedades de Superfície , Torque , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Implantação Dentária Endóssea/métodos , Planejamento de Prótese Dentária , Adulto , Resultado do Tratamento , Osseointegração/fisiologia
3.
J Periodontol ; 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696664

RESUMO

BACKGROUND: Growing evidence suggests the type of periodontal treatment could differentially influence the reduction of key cardiovascular risk mediators in periodontitis patients. This randomized, controlled clinical trial compared the impact of minimally invasive non-surgical therapy (MINST) with quadrant-wise subgingival instrumentation (Q-SI) on C-reactive protein (CRP) together with lipoprotein-associated phospholipase A2 (Lp-PLA2) levels, and clinical periodontal outcomes in patients with periodontitis. Moreover, it was evaluated if baseline CRP levels impacted the efficacy of non-surgical periodontal therapy protocols. METHODS: Forty-two periodontitis patients were enrolled and randomly treated by means of MINST (n = 21) or Q-SI (n = 21). The outcomes assessed were serum CRP and Lp-PLA2, and periodontal parameters (probing depth [PD], clinical attachment level [CAL], full-mouth bleeding score [FMBS]), at baseline and at follow-ups at 1, 3, and 6 months and at 1 year after treatment. RESULTS: At 1 year, MINST significantly reduced, among others, mean PD (p = 0.007), mean CAL (p = 0.007), the number of pockets >4 mm (p = 0.011) and ≥6 mm (p = 0.005), and FMBS (p = 0.048) compared to Q-SI. Generalized multivariate analysis evidenced that high baseline CRP (p = 0.039) and FMBS (p = 0.046) levels, together with MINST treatment (p = 0.007) were significant predictors of PD reduction at 1-year follow-up. Moreover, the Jonckheere-Terpstra test showed that patients with high baseline CRP levels gained more benefits from MINST treatment at 1-year follow-up than they did from Q-SI. CONCLUSION: Patients receiving MINST showed a greater reduction in CRP levels than patients with Q-SI after 1 year of follow-up. Moreover, patients with high baseline levels of CRP and Lp-PLA2 gained more benefits from the MINST approach at 1-year follow-up.

4.
Dent J (Basel) ; 12(5)2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38786529

RESUMO

Background: Coaxial implants with an inclined neck might overcome some problems related to angulation of the implant axis when using tilted implants. Therefore, the aim of the present work was to conduct a narrative review of the current literature and to present a case series comparing traditional and coaxial external hex implants in full-arch immediate loading rehabilitations of the maxilla. Methods: A total of 13 external hex tapered implants (Southern Implants) was inserted in the upper jaw of 3 patients. Each patient received two tilted implants in distal sites. In one randomly selected quadrant, the tilted implant was a standard implant, while a Co-Axis® implant with a 24° inclination of the implant shoulder was inserted on the other hemi-arch. Straight conical abutments were screwed on coaxial implants while multiunit abutments of appropriate inclination were screwed as needed on the other implants to correct their axes. Peri-implant bone level was recorded radiographically at T0 (delivery of the immediate loading prosthesis), and at 3, 6, 12, and 24 months of healing and then annually. Plaque index, probing depth, and bleeding on probing were also evaluated. Cumulative implant survival rate (CSR) was calculated, and biological or technical complications were recorded as well as the operator satisfaction towards the use of coaxial implants. Results: The preliminary data collected did not show significant differences in peri-implant tissues health and maintenance over time between the two implant types. No implants failed, and both implant types proved to be favorable for full-arch rehabilitation using tilted implants. Coaxial implants facilitated the prosthodontic procedures. However, a learning curve is required in order to optimize their insertion. Conclusions: Both implants proved to be reliable and suitable for achieving clinical success in full-arch immediate loading rehabilitations, but further research with longer follow-up and larger sample size is needed to confirm these preliminary outcomes.

5.
Medicina (Kaunas) ; 60(5)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38792929

RESUMO

Background and Objectives: The objective of this retrospective controlled study is to compare class II growing patients who underwent treatment with two different functional appliances: the Fraenkel regulator (FR-2), utilized as the control group, and the elastodontic device "Cranium Occluded Postural Multifunctional Harmonizers" (AMCOP), utilized as the test group. Materials and Methods: The study sample consisted of 52 patients with class II division I malocclusion (30 males, 22 females, mean age 8.6 ± 1.4 years) who were treated with the two different types of appliances: Group 1 (n = 27, mean age 8 [7.00, 9.00] years, 12 females, 15 males) received treatment with AMCOP, while Group 2 (n = 25, mean age 9.2 years [8.20, 10.00], 10 females, 15 males) received treatment with FR-2. The mean treatment duration for Group 1 was 28.00 [21.50, 38.00] months, while for Group 2 it was 23.70 [17.80, 27.40] months. Cephalometric analyses were performed on lateral cephalograms taken before treatment (T1) and after treatment (T2). Results: Significant intragroup differences were observed over time in Group 1 for 1^/PP. Similarly, significant intragroup differences were observed over time in Group 2 for SNB, ANB, and IMPA. Conclusions: Both treatment modalities resulted in the correction of class II malocclusion with dentoalveolar compensation, although the treatment duration with AMCOP tended to be longer on average.


Assuntos
Má Oclusão Classe II de Angle , Humanos , Masculino , Feminino , Criança , Estudos Retrospectivos , Má Oclusão Classe II de Angle/terapia , Aparelhos Ortodônticos Funcionais , Aparelhos Ortodônticos Removíveis , Cefalometria/métodos , Resultado do Tratamento
6.
Korean J Orthod ; 54(3): 160-170, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38800861

RESUMO

Objective: Owing to the availability of 3D software, scanners, and printers, clinicians are encouraged to produce in-office aligners. Recently, a new directprinting resin (Tera Harz TC-85DAC) has been introduced. Studies on its mechanical characteristics and biological effects have been published; however, evidence on its efficacy in orthodontic treatment remains scarce. This pilot study aimed to investigate the accuracy of teeth movement achieved with directprinted aligners. Methods: Seventeen patients (eight males and nine females) with a mean age of 27.67 ± 8.95 years, presenting with dental rotations < 30° and spaces/crowding < 5 mm, were recruited for this study. The teeth movement was planned starting from a T0 digital dental cast. The 3D direct-printed aligners were produced using Tera Harz TC-85DAC resin. Once the orthodontic treatment was completed, a final digital cast was obtained (T1). The planned teeth positions were then superimposed onto the T0 and T1 digital models. The differences between the programmed movements and the achieved overall torque, tip, rotation, and transverse dimensions were assessed using the paired t test or Wilcoxon's signed rank test. Results: The overall accuracies for torque, tip, and rotation were 67.6%, 64.2%, and 72.0%, respectively. The accuracy of the change in transverse diameter was 99.6%. Conclusions: Within the limits of the present pilot study (difficulties with abnormally shaped teeth and use of attachments), it can be concluded that 3D printed aligners can be successfully printed in-house and utilized for mildly crowded cases, with a comparable accuracy of tooth movement to that of other aligners.

7.
Dent J (Basel) ; 12(4)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38668023

RESUMO

BACKGROUND: Restorative materials might significantly affect load transmission in peri-implant bone. The aim of the present study is to evaluate the shock absorption capacity of two different polymeric materials to be used for implant-supported prostheses. METHODS: A masticatory robot was used to compare the shock absorption capacity of veneered and non-veneered polyetherketoneketone (PEKK), Pekkton®ivory (Cendres+Mètaux), and the glass fiber-reinforced composite (GFRC), TRINIATM (Bicon). Five identical sample crowns for each of the three groups were tested. Forces transmitted at the simulated peri-implant bone were recorded and statistically analyzed. RESULTS: The statistical analysis of forces transmitted at the simulated dental implant revealed significant differences between the materials tested and between these materials and zirconia, glass ceramic, composite resin, and acrylic resin. Only differences between PEKK and veneered PEKK and between PEKK and one of the previously tested composite resins were not statistically significant. PEKK samples demonstrated significantly greater shock absorption capacity compared to GFRC. CONCLUSIONS: PEKK revealed optimal shock absorption capacity. Further studies are needed to evaluate its efficacy in the case of long-span prostheses with reduced prosthetic volume.

8.
J Clin Med ; 13(7)2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38610826

RESUMO

Background: Fiber-reinforced composites (FRCs) have been proposed as an alternative to traditional metal alloys for the realization of frameworks in full-arch implant-supported prostheses. The aim of the present in vitro study was to evaluate the deflection under load of seven prostheses endowed with frameworks made of different materials, including different types of fiber-reinforced composites (FRCs). Methods: A master cast with four implant analogues in correspondence with the two lateral incisors and the two first molars was used to create full-arch fixed prostheses with the same shape and different materials. Prostheses were made of the following different materials (framework+veneering material): gold alloy+resin (Au+R), titanium+resin (Ti+R), FRC with multidirectional carbon fibers+resin (ICFRC+AR), FRC with unidirectional carbon fibers+composite (UCFRC+C), FRC with glass fibers+resin (GFRC+AR), FRC with glass fibers+composite (GFRC+C), and resin (R, fully acrylic prosthesis). Flexural tests were conducted using a Zwick/Roell Z 0.5 machine, and the deflection of the lower surface of the prosthesis was measured in order to obtain load/deflection graphs. Results: Greater rigidity and less deflection were recorded for UCFRC+C and GFRC+C, followed by Ti+R and Au+R. The greatest deformations were observed for resin alone, ICFRC+R, and GFRC+R. The results were slightly different in the incisal region, probably due to the greater amount of veneering material in this area. Conclusions: When used to realize full-arch frameworks, Au and Ti allow for predictable mechanical behavior with gradual deformations with increasing load. UCFRC also demonstrated good outcomes and less deflection than ICFRCs when loaded. The GFRC full-arch framework may be a valid alternative, although it showed greater deflections. Further studies are needed in order to evaluate how different prosthesis designs and material thicknesses might affect the outcomes.

9.
Int J Oral Maxillofac Implants ; 39(2): 294-301, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38657221

RESUMO

PURPOSE: To evaluate peri-implant tissue health and bone resorption in patients with implant-supported fixed partial rehabilitations. In particular, possible correlations between plaque accumulation and bone loss, as well as other periimplant health parameters, were investigated. MATERIALS AND METHODS: A total of 44 patients rehabilitated with fixed implant-supported partial rehabilitations were included. The following parameters were recorded: spontaneous bleeding (SB), suppuration, bleeding on probing (BOP), plaque index (PI), and probing depth (PD). Periapical radiographs were taken to measure crestal bone loss (BL). A nonparametric test (Spearman rank coefficient; rs) was used to identify possible correlations between the clinical parameters recorded. RESULTS: A total of 121 implants were analyzed. Global PI and BOP were 49.58% and 20.25%, respectively. There were no cases of suppuration, and only 2 implants showed spontaneous bleeding. Mean BL was 1.53 mm (SD: 0.98). No implants showed peri-implantitis. There was a weak, statistically significant correlation between PI and BL (rs = 0.27, P [2-tailed] = .99) and between PI and the other peri-implant parameters (BOP: rs = 0.14, P = .14; PD: rs = 0.04, P = .65; SB: rs = -0.08, P = .34). A very weak correlation was also found between BL and BOP (rs = 0.1, P = .2) and between BL and PD (rs = 0.02, P = .7). Correlation was found between BL and age (rs = 0.13, P = .81) and between the other peri-implant parameters and age using dichotomization (> or < 65 years; PI: rs = -0.14, P = .11; PD: rs = -0.21, P = .01; BOP: rs = -0.21, P = .01; SB: rs = 0.05, P = .53). No statistically significant correlations were found between the clinical parameters evaluated and the sex or the dental arch treated (maxilla vs mandible). In contrast, the correlation between periodontal parameters and years elapsed since surgery (follow-up) was significant. CONCLUSIONS: The present research suggests that in implant-supported fixed partial rehabilitations, dental implants with greater plaque accumulation are more likely to present augmented probing depth, peri-implant inflammation, and bone loss, although the correlation is statistically very weak. Patient age and time of follow-up also significantly affected peri-implant health parameters.


Assuntos
Perda do Osso Alveolar , Índice de Placa Dentária , Prótese Dentária Fixada por Implante , Índice Periodontal , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Perda do Osso Alveolar/etiologia , Idoso , Adulto , Prótese Parcial Fixa , Peri-Implantite/etiologia , Implantes Dentários
10.
J Periodontal Res ; 59(4): 647-656, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38666373

RESUMO

AIM: This study evaluated the efficacy of quadrantwise subgingival instrumentation (Q-SI) versus one-stage full-mouth subgingival instrumentation (FM-SI) on probing depth and periodontal pathogen reduction over a 6-month follow-up period, as well as whether baseline periodontal pathogens influenced the impact of periodontal treatment protocols on outcomes. METHODS: Patients with periodontitis were randomized to receive Q-SI (n = 43) or FM-SI (n = 45). Patients were instructed and motivated to maintain optimal oral hygiene during the treatment sessions. Clinical (probing pocket depth [PPD], clinical attachment loss [CAL], and bleeding on probing [BOP]) and periodontal pathogens were assessed at baseline and after 30, 90, and 180 days. Total bacterial load and periodontal pathogens were analysed via real-time PCR. RESULTS: At the 6-month follow-up, the median PPD decreased from 4.8 mm (interquartile range [IQR]: 4.3-5.2) to 2.6 mm (IQR: 2.3-2.9) in FM-SI patients and from 4.7 mm (IQR: 4.1-5.2) to 3.2 mm (IQR: 2.4-3.5) in Q-SI patients (p < .001). At 6 months, FM-SI was more effective at reducing the median proportions of Porphyromonas gingivalis (Pg), Aggregatibacter actinocomyctemcomitans, and Tannerella forsythia (Tf) (p < .001 for each value). Multilevel linear regression analysis demonstrated that high baseline PPD (p = .029), Pg (p = .014), and Tf (p < .001) levels and the FM-SI protocol (p < .001) were statistically significant predictors of PPD reduction at 6 months. Furthermore, PPD reduction was significantly greater in the FM-SI group when lower baseline Pg levels were detected. CONCLUSION: The FM-SI was more effective than the Q-SI in reducing the mean PPD and number of periodontal pathogens in periodontitis patients over a 6-month follow-up period. Higher baseline PPD and Pg levels had a negative impact on PPD reduction at 6 months after FM-SI.


Assuntos
Carga Bacteriana , Índice Periodontal , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Porphyromonas gingivalis/isolamento & purificação , Resultado do Tratamento , Bolsa Periodontal/microbiologia , Periodontite/microbiologia , Periodontite/terapia , Raspagem Dentária/instrumentação , Raspagem Dentária/métodos , Aggregatibacter actinomycetemcomitans/isolamento & purificação , Seguimentos , Perda da Inserção Periodontal/microbiologia , Tannerella forsythia/isolamento & purificação , Higiene Bucal , Reação em Cadeia da Polimerase em Tempo Real
11.
J Oral Implantol ; 50(1): 45-49, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579112

RESUMO

The stability of implant-abutment joint is fundamental for the long-term success of implant rehabilitation. The screw loosening, fracture, and head deformation are among the most common mechanical complications. Several surface treatments of titanium screws have been proposed to improve their resistance and stability. Diamond-like carbon (DLC) coating of the materials is widely used to increase their wear resistance and durability. The present study aimed to evaluate the effect of carbon fiber coating on the screw head on screw removal torque and screw head stripping. One hundred titanium implant screws were used, 50 without coating (Group 1) and 50 with DLC coating of the screw head (Group 2). Each screw was tightened with a torque of 25 Ncm and unscrewed 10 times. The removal torque was measured with a digital cap torque tester for each loosening. Optical 3d measurement of the screw head surface was performed by a fully automatic machine before and after multiple tightening to investigate surface modifications. The reverse torque values decreased with repeated tightening and loosening cycles in both groups without significant differences (P > .05). Optical measurements of surface dimensions revealed average changes of 0.0357 mm in Group 1 and 0.02312 mm in Group 2, which resulted to be statistically significant (P < .001). The DLC coating of the retention screw head can prevent its distortion and wear, especially after multiple tightening.


Assuntos
Implantes Dentários , Carbono , Titânio , Análise do Estresse Dentário/métodos , Torque , Parafusos Ósseos , Dente Suporte
12.
J Dent ; 145: 104979, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38556193

RESUMO

OBJECTIVES: The aim of the present in vitro study was to evaluate the effect of a novel auxiliary geometric device (AGD) on the accuracy of full-arch scans captured with 3 different intraoral scanners (IOS). METHODS: An edentulous maxillary model with four internal connection implant replicas was scanned using 3 different IOS: iTero Element 5D (ITERO) (Align Technology, Tempe, AZ, USA), Trios 4 (TRIOS) (3Shape A/S, Copenhagen, Denmark), and Carestream 3700 (CS) (Carestream Dental, Atlanta, USA). Thirty-six scans were taken with each IOS, 18 with the AGD in place, and 18 without the AGD. A digital master model was created using an industrial optical scanner (ATOS compact Scan 5M, GOM GmbH, Braunschweig, Germany). The master and IOS models were aligned using the scan bodies as a reference area. A surface comparison was performed, and deviation labels were exported for each scan body to evaluate the linear and angular deviation. Total body, platform and angular deviations were measured. RESULTS: The use of AGD resulted in a statistically significant increase of angular deviation: 0.87° (SD=0.21) in the AGD group versus 0.64° (SD=0.46) in the no AGD group (p-value=0.005). The difference between the AGD and no AGD groups was not statistically significant for total body and platform deviation values (p-value=0.051 and 0.302 respectively). Using AGD, ITERO showed a statistically significant increase in angular deviation (mean difference=-0.46 µm, p-value=0.002) and a decrease in mean platform deviation (mean difference=63.19 µm, p-value<0.001). No statistically significant differences were found for the other IOS. CONCLUSIONS: The use of AGD did not add benefit on CS and TRIOS. On ITERO, there was an improvement in platform deviation, that was outweighed by the worsening of the angular deviation. CLINICAL SIGNIFICANCE: In vitro data suggest that intraoral scans can be successfully used in full-arch cases. The use of AGD has no additional benefit on CS and TRIOS. On ITERO there was an improvement in platform deviation that was outweighed by the worsening of the angular deviation. Translational application to clinical practice deserves further investigation, taking into account patient-related and anatomical variables.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Modelos Dentários , Humanos , Maxila/diagnóstico por imagem , Desenho Assistido por Computador , Imageamento Tridimensional/métodos , Arcada Edêntula/diagnóstico por imagem , Arcada Edêntula/reabilitação , Técnicas In Vitro , Arco Dental/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Planejamento de Prótese Dentária
13.
Dent J (Basel) ; 12(3)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38534295

RESUMO

This study was conducted to compare the effects of an innovative plasma surface treatment device that does not need a gas supply for titanium disks with two different surface topographies: the prototypical machined surface (MAC) and one of the most diffused roughened ones (SL) obtained through grit blasting and acid etching. A total of 200-MAC and 200-SL titanium disks were used. Each group of disks was divided into four sub-groups of 40 samples each that were subjected to five different tests. Among these, 150-MAC and 150-SL were considered the test group, and they were treated with plasma for 15, 30, and 60 s after being removed from the sterile packaging. On the other hand, 50-MAC and 50-SL were considered the control group, and they were only removed from sterile plastic vials. The samples were analyzed to evaluate the capability of the plasma treatment in influencing protein adsorption, cell adhesion, proliferation, and microbial growth on the test group disks when compared to the untreated disks. Protein adsorption was significantly enhanced after 20 min of plasma treatment for 15 and 30 s on the MAC and SL disks. Plasma treatment for 15 and 30 s significantly increased the level of adhesion in both treated samples after 30 min. Furthermore, the MAC samples showed a significant increase in cell adhesion 4 h after plasma treatment for 15 s. The SEM analysis highlighted that, on the treated samples (especially on the MAC disks), the cells with a polygonal and flat shape prevailed, while the fusiform- and globular-shaped cells were rare. The encouraging results obtained further confirm the effectiveness of plasma treatments on cell adhesion and fibroblast activity.

14.
Int J Oral Maxillofac Implants ; 39(1): 87-98, 2024 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-38416003

RESUMO

PURPOSE: To investigate the possible antimicrobial activity of glycine air polishing by comparing peri-implant microbiota before and after treatment. MATERIALS AND METHODS: A total of 15 patients who received implant-supported full-arch fixed rehabilitations were included. After prosthesis removal (T0), Plaque Index (PI), probing depth (PD), and bleeding on probing (BOP) were recorded. In each hemiarch, the implant with the highest PD score was selected for microbiologic sample collection from the peri-implant sulcus (T0). All patients received two different hygienic protocols (randomly administered, one per each hemiarch): glycine air-polishing (G) and cleansing with cotton pellets soaked in saline (C). At 7 days (T1) and 3 months (T2) after the intervention, PI and BOP were recorded, and new microbiologic samples were taken. Traditional polymerase chain reaction (PCR) and quantitative PCR real-time were employed for microbiologic analysis to investigate how the presence of different bacterial species varied according to the hygienic treatment performed. RESULTS: Treatment G provided a significantly higher PI score reduction around implants compared to treatment C (P = .015). No statistical difference was found in the microbial population around G and C implant sites, with Tannerella forsythia being the most commonly detected bacterial species in both G and C groups. No statistical differences were found between the antimicrobial activity of treatments C and G. CONCLUSIONS: Glycine powder air polishing is a valid method for professional hygienic care of implants and was more effective in PI reduction compared to the control treatment. However, its antimicrobial efficacy cannot be confirmed by the outcomes of the present study.


Assuntos
Implantes Dentários , Polimento Dentário , Humanos , Boca , Face , Glicina/uso terapêutico
15.
Dent J (Basel) ; 11(10)2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37886911

RESUMO

Zygomatic implants are used for the rehabilitation of the upper jaw of patients with severe and moderate bone atrophy. Possible post-surgical complications include soft tissue dehiscence, sinusitis, and prosthodontic fractures, and maintaining an accurate control is crucial. Additionally, zygomatic implants have a unique peri-implant anatomy, making traditional periodontal parameters unsuitable. The present paper aims to provide guidelines for the maintenance and interception of complications in patients rehabilitated with these kinds of implants. The proposed protocol includes: 1. intra/extraoral and temporo-mandibular joint examination; 2. soft tissue and transmucosal path observation with magnifiers; 3. peri-implant health indices and digital stimulation of tissues; 4. examination of prosthodontic devices; and 5. photographic recording. These steps facilitate the comprehensive evaluation and monitoring of clinical conditions of zygomatic-supported rehabilitations, including dehiscence and occlusal wear during follow-up appointments.

16.
Clin Oral Investig ; 27(11): 6855-6863, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37814162

RESUMO

OBJECTIVES: The present study aims to assess the serum circulating cell-free (cfDNA) concentrations in patients with periodontitis and cardiovascular disease (CVD) and to evaluate the impact of periodontitis on circulating cfDNA levels and the confounding factors that might mediated the possible relationship. MATERIALS AND METHODS: Healthy controls (n=30) and patients with CVD (n=31), periodontitis (n=31), and periodontitis + CVD (n=30) were enrolled in the present study. All subjects underwent regular periodontal examination and blood sampling and cfDNA evaluation. The analysis of the plasma cfDNA concentrations was performed using a dsDNA Assay Kit. RESULTS: In comparison with healthy controls and CVD patients, periodontitis and periodontitis+CVD exhibited significantly higher expression of circulating cfDNA (p<0.05). There was a positive correlation among plasma cfDNA and clinical attachment loss (CAL) (p=0.019), high sensitivity C-reactive protein (hs-CRP) (p=0.027), and periodontal inflamed surface area (PISA) (p=0.003). Furthermore, the multivariate regression analysis evidenced that PISA (p<0.001), hs-CRP (p=0.014), and full-mouth bleeding score (FMBS) (p=0.004) were significant predictors of circulating cfDNA concentrations. CONCLUSIONS: The results of the study highlighted that the periodontitis and periodontitis + CVD group showed higher circulating cfDNA expression in comparison with healthy controls and CVD patients. Moreover, the extent of periodontitis was correlated with the increased cfDNA levels and represented a significant predictor of the increased circulating cfDNA concentrations. CLINICAL RELEVANCE: Unbalanced circulating cfDNA concentrations have been indicated to represent a possible risk of CVD and endothelial dysfunction. Periodontitis and periodontitis + CVD patients showed higher circulating cfDNA expression; moreover, the extent of periodontitis significantly predicted higher circulating cfDNA concentrations, suggesting the potential increased risk of developing CVD in periodontitis patients.


Assuntos
Doenças Cardiovasculares , Ácidos Nucleicos Livres , Periodontite , Humanos , Proteína C-Reativa/análise , Periodontite/complicações , Análise Multivariada
17.
Int J Oral Maxillofac Implants ; 38(5): 923-932, 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37847834

RESUMO

PURPOSE: To compare bone substitutes composed of glycated collagen with synthetic micro-sized (1 to 10 µm) hydroxyapatite (OB) vs non-cross-linked collagen matrix with large-particle (250 to 1,000 µm) bovine-derived hydroxyapatite (BOC). MATERIALS AND METHODS: The P1 to P4 premolars were bilaterally extracted from the mandibles of 19 Beagle dogs. After 21 days, osteotomies were created in each dog that received OB or BOC and were covered with a collagen membrane or were left untreated. The animals were randomly divided into three groups based on sacrifice time (4, 12, or 24 weeks). The right and left hemimandibles were trimmed to facilitate imaging and histology, and all tissues were placed in 10% neutral-buffered formalin. Microcomputed tomography (MicroCT 40 Scanner, Scanco) was used to analyze bone sections. Bone volume, residual material volume, and bone mineral density were determined for each treatment site (OB and BOC) based on a volume of interest that encompassed the original defect. Additionally, blinded histopathologic assessment (based on the ISO 10993-6 scoring system) and histomorphometry were performed on sections ground to < 100 µm thick and stained with Stevenel's blue. RESULTS: No clinical side effects were noted. No statistical differences were observed for OB vs BOC regarding the mineral volume percentage. Compared to OB, BOC had significantly higher mean mineralization densities at 12 weeks (P < .01), but this difference did not extend to 24 weeks. For residual grafting material, bone maturation, alveolar ridge restoration, and inflammatory response, OB showed a residual amount of bone graft and no statistical differences compared to BOC. CONCLUSION: Both OB and BOC represent valid treatment options for critically sized bone defects. Both bone fillers outperformed the sham-operated, ungrafted (empty) control, demonstrating statistically improved bone growth and ridge restoration.


Assuntos
Aumento do Rebordo Alveolar , Substitutos Ósseos , Cães , Animais , Bovinos , Durapatita/uso terapêutico , Osteogênese , Microtomografia por Raio-X , Regeneração Tecidual Guiada Periodontal/métodos , Regeneração Óssea/fisiologia , Substitutos Ósseos/uso terapêutico , Colágeno/uso terapêutico , Aumento do Rebordo Alveolar/métodos
18.
Int J Oral Maxillofac Implants ; 38(4): 801-810, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37669520

RESUMO

Purpose: To compare glycated multilayered membranes (OV) to a commercially available thin-layer membrane (OP) in a lateral ridge augmentation model in dogs. Materials and Methods: This was designed as a three-arm study, where one negative control (empty defect) was compared to two test arms: alveolar bone defects grafted with a mixture of 90% deproteinized bovine bone mineral and 10% porcine collagen, then covered with either a thick- (OV) or thin-layered (OP) membrane. Animals were randomly divided into three groups corresponding to the final sacrifice times of 4 weeks, 12 weeks, and 24 weeks. Sections underwent microCT, histology, histopathology, and histomorphometry. Results: No statistical differences were observed for OV compared to OP regarding the percentage of mineral volume and mean mineral density, amount of bone maturation, percentage of bone graft and membrane remaining in the grafted area, alveolar ridge width measurements, membrane mineralization, or ossification. Test groups presented significantly higher values compared to the empty control for all the endpoints. Conclusions: Within its limitations, this in vivo study highlighted that multilayered thick glycated membranes can serve as effective occlusive barriers for up to 6 months.


Assuntos
Aumento do Rebordo Alveolar , Substitutos Ósseos , Animais , Bovinos , Cães , Aumento do Rebordo Alveolar/métodos , Regeneração Óssea , Colágeno , Regeneração Tecidual Guiada Periodontal , Membranas Artificiais , Minerais , Osteogênese , Suínos , Distribuição Aleatória
19.
Ther Adv Chronic Dis ; 14: 20406223231191043, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37720593

RESUMO

Periodontitis is a persistent inflammation of the soft tissue around the teeth that affects 60% of the population in the globe. The self-maintenance of the inflammatory process can cause periodontal damage from the alveolar bone resorption to tooth loss in order to contrast the effects of periodontitis, the main therapy used is scaling and root planing (SRP). At the same time, studying the physiopathology of periodontitis has shown the possibility of using a local drug delivery system as an adjunctive therapy. Using local drug delivery devices in conjunction with SRP therapy for periodontitis is a potential tool since it increases drug efficacy and minimizes negative effects by managing drug release. This review emphasized how the use of local drug delivery agents and natural agents could be promising adjuvants for the treatment of periodontitis patients affected or not by cardiovascular disease, diabetes, and other system problems. Moreover, the review evidences the current issues and new ideas that can inspire potential later study for both basic research and clinical practice for a tailored approach.

20.
Int J Mol Sci ; 24(12)2023 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-37373135

RESUMO

In the last few decades, circulating cell-free DNA (cfDNA) has been shown to have an important role in cell apoptosis or necrosis, including in the development and evolution of several tumors and inflammatory diseases in humans. In this regard, periodontitis, a chronic inflammatory disease that can induce the destruction of supporting components of the teeth, could represent a chronic inflammatory stimulus linked to a various range of systemic inflammatory diseases. Recently, a possible correlation between periodontal disease and cfDNA has been shown, representing new important diagnostic-therapeutic perspectives. During the development of periodontitis, cfDNA is released in biological fluids such as blood, saliva, urine and other body fluids and represents an important index of inflammation. Due to the possibility of withdrawing some of these liquids in a non-invasive way, cfDNA could be used as a possible biomarker for periodontal disease. In addition, discovering a proportional relationship between cfDNA levels and the severity of periodontitis, expressed through the disease extent, could open the prospect of using cfDNA as a possible therapeutic target. The aim of this article is to report what researchers have discovered in recent years about circulating cfDNA in the development, evolution and therapy of periodontitis. The analyzed literature review shows that cfDNA has considerable potential as a diagnostic, therapeutic biomarker and therapeutic target in periodontal disease; however, further studies are needed for cfDNA to be used in clinical practice.


Assuntos
Ácidos Nucleicos Livres , Neoplasias , Doenças Periodontais , Periodontite , Humanos , Periodontite/diagnóstico , Periodontite/genética , Biomarcadores , Ácidos Nucleicos Livres/genética , Inflamação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...