1.
Lab Chip ; 10(24): 3380-6, 2010 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-21060907

RESUMO

We describe a perfusion-based microfluidic device for three-dimensional (3D) dynamic primary human hepatocyte cell culture. The microfluidic device was used to promote and maintain 3D tissue-like cellular morphology and cell-specific functionality of primary human hepatocytes by restoring membrane polarity and hepatocyte transport function in vitro without the addition of biological or synthetic matrices or coagulants. A unique feature of our dynamic cell culture device is the creation of a microenvironment, without the addition of biological or synthetic matrices or coagulants, that promotes the 3D organization of hepatocytes into cord-like structures that exhibit functional membrane polarity as evidenced by the expression of gap junctions and the formation of an extended, functionally active, bile canalicular network.


Assuntos
Técnicas de Cultura de Células/instrumentação , Técnicas de Cultura de Células/métodos , Hepatócitos/citologia , Imageamento Tridimensional/métodos , Técnicas Analíticas Microfluídicas , Trifosfato de Adenosina/química , Canalículos Biliares/citologia , Células Cultivadas , Coagulantes/química , Desenho de Equipamento , Junções Comunicantes , Humanos , Microscopia de Fluorescência/métodos , Modelos Biológicos , Proteína 2 Associada à Farmacorresistência Múltipla , Proteínas Associadas à Resistência a Múltiplos Medicamentos/metabolismo , Perfusão
2.
Langmuir ; 25(1): 36-9, 2009 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-19049394

RESUMO

Many biological materials and cell substrates are very soft (Young's modulus <500 Pa) and it is difficult to characterize their mechanical properties. Here we report local elasticity of the surface layers of Matrigel films used for cell culture. We used a new measurement technology, mechanical imaging interferometry, to obtain point mechanical measurements over micron-sized areas. The median values of 650 +/- 400 Pa (# measurements, n = 50), determined by the Hertz contact model, agree well with bulk measurements; however, on the microscale, the films were heterogeneous and contained regions distinctly stiffer than average (1-2 kPa). The first measurement of yield strengths of 170 +/- 100 Pa (n = 43) indicates that Matrigel films deform plastically at stress levels of similar scale to cell tractional forces.


Assuntos
Colágeno , Laminina , Proteoglicanas , Técnicas de Cultura de Células , Combinação de Medicamentos