Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
HNO ; 50(8): 739-42, 2002 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-12243029

RESUMO

BACKGROUND AND OBJECTIVE: An efficient training program in ear surgery needs suitable models to learn the specific preparation techniques. However, conventionally fixed or fresh frozen ears of human corpses do not meet all demands. Therefore we investigated the feasibility of ears fixed according to Thiel for surgical training in the temporal bone lab. METHODS: Various surgical techniques on external and middle ears were evaluated on ears from cadavers fixed according to Thiel. Structure and consistency of the tissues were compared to vital conditions by means of a standardized questionnaire. RESULTS: Structure and consistency of the tissues of the auditory canal, the tympanic cavity and the mastoid were comparable to vital conditions. Merely the cartilage of the auricle was considerable softened. This enabled a surgical preparation under conditions close to the intravital situation. CONCLUSIONS: Under the aspects of quality assurance and efficiency of continuous medical education in middle ear surgery, the Thiel fixation technique provides an excellent prerequisite.


Assuntos
Orelha Média/cirurgia , Educação Médica Continuada , Educação de Pós-Graduação em Medicina , Otolaringologia/educação , Fixação de Tecidos , Cadáver , Currículo/normas , Orelha Média/patologia , Humanos , Garantia da Qualidade dos Cuidados de Saúde
3.
Knee Surg Sports Traumatol Arthrosc ; 10(2): 126-9, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11914772

RESUMO

The success of arthroscopic capsular release of the glenohumeral joint depends on complete incision of the inferior capsule. This study determined the distance between capsule and the axillary nerve in different joint positions. In 14 human shoulder specimens the anterior joint capsule and axillary nerve were dissected, and the anterior joint capsule was incised between the 1 and 5 o'clock positions. The shortest distance between the insertion of the inferior capsule and the axillary nerve was measured at the glenoid and humeral insertions in abduction, adduction, internal, and external rotation. The axillary nerve is surrounded from soft connective tissue and is closer to the humeral than to the glenoidal attachment of the joint capsule. During abduction and external rotation the nerve stays in its position while the glenohumeral capsule tightens, which increases the distance between the two structures. This results in the following distances: to the glenoidal/humeral capsule insertion: in adduction and neutral rotation, 21.2+/-4.2/14.2+/-2.6 mm; in abduction and neutral rotation, 24.0+/-4.9/15.0+/-5.0 mm; in abduction and internal rotation, 21.1+/-6.6/14.6+/-3.7 mm; and in abduction and external rotation, 24.9+/-3.8/16.4+/-4.4 mm. Thus, when performing arthroscopic capsular release the incision of the glenohumeral joint capsule should be undertaken at the glenoidal insertion in the abducted and externally rotated shoulder.


Assuntos
Artroscopia , Axila/inervação , Axila/patologia , Bursite/patologia , Bursite/cirurgia , Cápsula Articular/patologia , Cápsula Articular/cirurgia , Postura , Articulação do Ombro/patologia , Articulação do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Cápsula Articular/inervação , Masculino , Pessoa de Meia-Idade , Medição de Risco , Articulação do Ombro/inervação
4.
Clin Anat ; 14(4): 282-4, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11424204

RESUMO

During a routine dissection course at the University of Muenster (Germany) an unusual course of the lingual nerve was found with entrapment of the nerve between a widely ossified pterygospinous ligament and the medial pterygoid muscle. Furthermore, the nerve's mobility was restricted by a more distal anastomosis with the inferior alveolar nerve. Although incomplete or complete ossification of the pterygospinous ligament is not uncommon, the combination with a medial course of the lingual nerve has not been described before. Besides practical importance for surgeons and anesthetists, the entrapment of the lingual nerve may lead to lingual numbness and pain associated with speech impairment.


Assuntos
Ligamentos/patologia , Nervo Lingual/patologia , Síndromes de Compressão Nervosa/patologia , Ossificação Heterotópica/patologia , Idoso , Idoso de 80 Anos ou mais , Dissecação , Humanos , Masculino , Síndromes de Compressão Nervosa/etiologia , Ossificação Heterotópica/complicações , Músculos Pterigoides/patologia
5.
J Shoulder Elbow Surg ; 10(3): 265-8, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11408910

RESUMO

A modified surgical approach to the posterior aspect of the glenohumeral joint and/or the dorsal glenoid is described. This access does not alter any muscle insertion or neuromuscular planes. After the skin incision is made, the inferior border of the spinal part of the deltoid is identified and the deltoid muscle is mobilized and retracted, thus offering an excellent approach to the interval between the infraspinatus and teres minor muscles. This interval is split parallel to the muscle fibers. This surgical approach was first established in 10 cadaverous shoulders and then performed in 12 patients with posterior shoulder pathology. In the cadaver study, the closest distance to the axillary nerve with this approach was 22 mm. In all 12 cases, the surgical procedure could be performed without any problems.


Assuntos
Procedimentos Ortopédicos/métodos , Articulação do Ombro/cirurgia , Braço/cirurgia , Cadáver , Humanos , Músculo Esquelético/cirurgia , Articulação do Ombro/patologia
7.
Mund Kiefer Gesichtschir ; 5(2): 141-3, 2001 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-11372181

RESUMO

METHODS: This study investigates whether human cadavers embalmed according to Thiel can be used for research and education in oral-maxillo-facial surgery. Different surgical approaches were tested on such cadavers. The usability of the specimen was judged jointly by anatomists and surgeons. Color, structure, and consistency of the different tissues were comparable to vital conditions. Thiel's embalming technique applied to human cadavers provides an optimal basis for research and for basic and postgraduate medical education.


Assuntos
Educação de Pós-Graduação em Odontologia , Educação de Pós-Graduação em Medicina , Embalsamamento , Cirurgia Bucal/educação , Currículo , Humanos
8.
Radiologe ; 41(2): 181-6, 2001 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-11253104

RESUMO

The aim of this study was to analyse pathomorphological findings after treatment with laser induced tumor thermotherapy (LITT) on liver tissue and to correlate the results with magnetic resonance imaging. LITT was performed ex vivo and in vivo using a Neodym-YAG-Laser. Lesions were monitored by MR-thermometry ex vivo and by contrast-enhanced MRI in vivo. After LITT the lesions were examined macroscopically, histologically, and electronmicroscopically. LITT-induced tissue damage was qualitatively evaluated, classified, and quantified by means of digital image analysis. Four different zones of tissue damage were identified within the lesions. Adjacent to the applicator the tissue was completely ablated while more peripheral lesions exhibited only sublethal cell damages seen by EM. In vivo the pattern of tissue injury followed the lobular architecture of the liver tissue. Ultrastructural examination revealed only in areas of minor tissue injury intact sinusoidal patterns. MRI overestimated the diameter of the core zone of complete tissue ablation both ex vivo and to a lesser extent in vivo.


Assuntos
Hipertermia Induzida/métodos , Neoplasias Hepáticas/terapia , Animais , Humanos , Fígado/patologia , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Microscopia Eletrônica , Coelhos , Suínos
10.
Biomed Tech (Berl) ; 45(9): 228-37, 2000 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-11030092

RESUMO

We evaluated the accuracy of the needle tip representation by different imaging techniques for the guidance of facet infiltrations. For visualisation of the lumbar facet joints we used a high-field magnetic resonance tomograph (MRT) with a 2.0 Tesla field and 3.5 mm slice thickness, an open low-field magnetic resonance tomography (MRT) with an 0.064 Tesla field and 9 mm slice thickness, and IMATRON electron beam computed tomograph (EBCT) with a slice thickness of 6 mm, and a mobile C-arm fluoroscope. The study was performed on 4 human cadaveric lumber spine preparations, each of which had 8 facet joints. Under imaging control, special injection needles were placed as close as possible to the facet joint space. Following placement of he needle, all specimens were scanned with the electron beam tomograph using a slice thickness of 1.5 mm. The thin-slice study served as the gold standard. The distance between the tip of the needle and the facet joint was measured in all the images. Comparison of the different modalities with the gold standard revealed the following results: 1) median values of the absolute differences were 1.25 mm for high-field MRI, 1.35 mm for 6 mm EBCT, 2.05 mm for low-field MRI, and 2.30 mm for X-ray fluoroscopy. 2) While there was no statistically significant difference in the accuracy of tip localization between high-field MRI and 6" EBCT (p = 0.293), both systems were more precise than low-field MRI (p = 0.04) and X-ray fluoroscopy (p = 0.009). When choosing the best imaging technique, such additional factors as radiation, costs and time, must also be considered. Provided necessary radiological precautions are taken, and assuming careful pre-interventional planning, CT. EBCT and X-ray fluoroscopy are currently more effective than the expensive, time-consuming and costly magnetic resonance tomography.


Assuntos
Vértebras Lombares/efeitos dos fármacos , Imageamento por Ressonância Magnética/instrumentação , Radiologia Intervencionista/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Desenho de Equipamento , Humanos , Instilação de Medicamentos , Vértebras Lombares/patologia , Sensibilidade e Especificidade
11.
Orthopade ; 29(7): 605-13, 2000 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-10986705

RESUMO

The purpose of the present study was to increase the free range of motion in conventional trust-plate prosthesis design and to optimize the trust-plate contact as well as the osteointegration area below the trust-plate. For the first part of the study, the two-dimensional geometry of the osteotomy plane was demonstrated in 25 CT-reconstructed femora after performing a virtual cut at a CCD angle of 135 degrees. In the second part, we constructed a prototype of an anatomic adapted trust-plate prosthesis (A-TPP) with an optimized trust-plate and corpus geometry based on the three-dimensional data of three human cadaveric femurs (age 67-75 years). In the final step, we documented the range of motion with computer-aided movement-mapping and compared the conventional TPP with the A-TPP. The results showed a wide variance in osteotomy geometry in the 12 femurs. With the A-TPP, we were able to obtain a much better fit in the trust plate surface. The movement-mapping showed a much higher range of motion in the A-TPP implant. With the A-TPP, the implant surface area for osteointegration could also be significantly increased.


Assuntos
Artroplastia de Quadril , Simulação por Computador , Prótese de Quadril , Osteotomia , Amplitude de Movimento Articular , Adolescente , Adulto , Idoso , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Ajuste de Prótese , Software , Tomografia Computadorizada por Raios X
12.
J Pathol ; 190(5): 635-8, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10727991

RESUMO

Reflection contrast microscopy (RCM), which utilizes the optical phenomena caused by oblique epi-illumination in combination with a specific optical apparatus, provides an approach for exploring biological phenomena in greater detail. The lack of stray reflection makes it superior to other microscopes. It bridges light and electron microscopic capabilities by allowing the analysis of ultrathin sections beyond the usual light microscopic magnification. By using consecutive image analysis, quantitation can be achieved. The wide range of applications of RCM can be combined with most microscopical techniques, so extending the spectrum of information that can be gathered. Twenty-five years after the development of RCM, there is still scope for its application in modern cell biology.


Assuntos
Microscopia de Interferência/métodos , Animais , Humanos , Microscopia de Interferência/instrumentação , Ratos , Nervo Isquiático/ultraestrutura
13.
Comput Methods Programs Biomed ; 61(3): 157-62, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10710178

RESUMO

The independence of teachers and students is one of the main advantages of teleteaching. Specialties considered unsuitable for combined lessons are manageable using the internet. This study outlines simultaneous communication with students and lecturers over long distances between the anatomical dissection laboratory, the operating theatre, and the lecture hall. In several three-directional on-line lectures, different equipment was used. Students could also participate using personal computers from other locations. During the presentations, the participants have the opportunity to discuss problems with any lecturer. It was possible to demonstrate sufficient transmission capability for real-time application with the use of the new internet technology. No important qualitative differences can be reported between: hardware and software based solutions; or commercial and free offers. Although it is often difficult to reconcile the timetable of surgeries and lectures, multimedia on-line teaching via the internet provides new potential for interdisciplinary medical education.


Assuntos
Instrução por Computador , Internet , Ensino/métodos , Humanos , Internet/instrumentação
14.
Ann Anat ; 181(5): 499-508, 1999 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-10560017

RESUMO

For the purposes of a functioning information and knowledge based medicine the conditions for the medical education are crucial. Although multimedia based courses and tutorials via the Internet seem to serve best for a more effective teaching and new didactics, respective anatomical offers in Germany are scarce and thus practice and experience are limited. Only simple digital equivalents of conventional contents and methods can be found, whereas the potencies of the new media are not realized in didactic concepts. Substantial advantages of web based tutorial systems are an intensive use of the feedback possibilities, the opportunity for continuous updating of the contents, the favourable distribution, and faster utilization of improved techniques. This paper introduces the adaptation of different techniques and the development of concepts and notions of modern Internet based teaching by the way of three different events in anatomical education for medical students and doctors. HistoNet 2000 was developed as an interface of lectures, seminars and practical courses in microscopy. The online transmission of a microscopical course as an interactive practical teleteaching was performed by the way of asymmetric data transfer via the ADSL-technology. Multicasting was used as well and has also been applied for the third project. In this multimedial online teaching different specialties were joined together for interdisciplinary courses via the Internet. These new technologies lead to enhanced efficiency in teaching and enlarge the educational offer. Specific Internet adapted teaching and learning projects have to be developed.


Assuntos
Anatomia/educação , Educação a Distância , Educação Médica , Internet , Educação Médica Continuada , Alemanha , Humanos , Microscopia , Médicos , Estudantes de Medicina
15.
Arch Fam Med ; 8(6): 553-8, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10575398

RESUMO

OBJECTIVES: To review the traumatic injuries that have been associated with acupuncture and to discuss how these adverse effects may be reduced by increased awareness of normal anatomy and anatomical variations. METHODS: Literature search accompanied by postmortem anatomical studies. RESULTS: Traumatic lesions after acupuncture have been described in thoracic and abdominal viscera, in the peripheral and central nervous systems, and in blood vessels. Deaths have been recorded from pneumothorax and cardiac tamponade. The anatomical structure of the body at several acupuncture points is such that needles can reach vulnerable structures. CONCLUSION: While the frequency of adverse effects of acupuncture is unknown and they may be rare, knowledge of normal anatomy and anatomical variations is essential for safe practice and should be reviewed by regulatory bodies and those responsible for training courses.


Assuntos
Terapia por Acupuntura/efeitos adversos , Vasos Sanguíneos/lesões , Tamponamento Cardíaco/etiologia , Humanos , Traumatismos dos Nervos Periféricos , Pneumotórax/etiologia
16.
Biomed Tech (Berl) ; 44(9): 243-6, 1999 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-10520532

RESUMO

The purpose of the present study was to evaluate, in vitro, a newly designed spinaloscope with a diameter of 1.8 mm, with integrated portals for instruments and irrigation. The 0 degree optical system has a resolution of 6,000 pixels. The instrument portals can be used for surgical lasers, biopsy forceps or burrs. We carried out our evaluations on fresh (unfixed) human lumbar spine specimens. The position of the endoscope was documented by CT scans. The endoscope was introduced into the spinal canal via the hiatus sacralis using a blunt trocar. The various structures and tissues were clearly identifiable and included the dura, the lig. flavum, the lig. long. posterior, spinal nerves, small pieces of disc material and various fibrous bands. The usefulness of the biopsy forceps was also shown.


Assuntos
Endoscópios , Endoscopia , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Doenças da Coluna Vertebral/cirurgia , Biópsia/instrumentação , Desenho de Equipamento , Humanos , Vértebras Lombares/cirurgia , Instrumentos Cirúrgicos
17.
Biomed Tech (Berl) ; 44(7-8): 190-3, 1999.
Artigo em Alemão | MEDLINE | ID: mdl-10472725

RESUMO

The present study was conducted with the aim of establishing whether minimally invasive percutaneous techniques used to stabilize osteoporotic vertebrae are technically feasible. Two different methods were investigated in human thoracolumbar cadaveric vertebrae. In the first technique, special titanium implants were placed via a postero-lateral approach. With the second method, the vertebrae were filled with different types of cement of different viscosities. After each procedure, the vertebrae were examined with conventional X-ray and CT scans. The first technique proved quite unsuccessful--the insertion of the titanium implants proving difficult despite the use of special instruments. The results achieved with the second method were much better. The use of low-viscosity bone cement produced the best results. Despite a single lateral point of entry, the vertebrae were almost completely filled right into the contralateral side. Lumbar vertebrae required an average volume of cement of 7 ml (range: 6.5-10 ml) and thoracic vertebrae 5.5 ml (range: 4-7 ml). Specially developed cement application devices made possible problem-free, controlled introduction of the cement.


Assuntos
Cimentos Ósseos , Endoscópios , Osteoporose Pós-Menopausa/cirurgia , Próteses e Implantes , Doenças da Coluna Vertebral/cirurgia , Titânio , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Osteoporose Pós-Menopausa/diagnóstico por imagem , Radiografia , Doenças da Coluna Vertebral/diagnóstico por imagem , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgia , Viscosidade
18.
Biomed Tech (Berl) ; 44(3): 64-70, 1999 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-10321053

RESUMO

The purpose of the present study was to document the osteotomy plane for the thrust plate prosthesis, and to evaluate the question whether the geometry of the thrust plate itself correlates with the range of motion after implantation and whether the osteointegration area can be optimised. For the first part of the study, the two-dimensional geometry of the osteotomy was demonstrated in 12 computer-reconstructed femurs after performing a virtual cut at a CCD angle of 135 degrees. In the second part we constructed a prototype of an I-TPP with an optimised thrust plate and corpus geometry. In a final step, we documented the range of motion with computer-aided movement mapping. The results showed a wide variance in osteotomy geometry in the 12 femurs. With the I-TAP we were able to obtain a much better surface adaptation of the thrust plate. Movement mapping showed a much lower range of motion in the I-TPP implant.


Assuntos
Placas Ósseas/normas , Desenho de Prótese/métodos , Placas Ósseas/tendências , Desenho de Prótese/instrumentação
19.
Zentralbl Gynakol ; 120(9): 471-3, 1998.
Artigo em Alemão | MEDLINE | ID: mdl-9796096

RESUMO

The local independence of students and teachers is accepted to be one of the main advantages of teleteaching. New techniques allow to use the Internet protocol similar to video conferences, thus giving premises to link specialties which have to operate in different environments. Synchronous communication can be established with students even over long-distances. In a pilot study a three-directional lecture between an operating theatre, the dissection laboratory of the institute of anatomy, and a lecture hall was given. During the lesson students discussed problems with any lecturer. We were able to demonstrate a sufficient transmission capability for this real-time application provided by the available internet technology. On the other hand, great technical and personnel effort for this computer aided MOT is necessary. However, although it is often difficult to reconcile the timetable of surgeries and lectures MOT provides new potentialities in interdisciplinary medical education.


Assuntos
Instrução por Computador , Educação Médica , Multimídia , Sistemas On-Line , Currículo , Alemanha , Humanos , Projetos Piloto
20.
Chirurg ; 69(12): 1324-8, 1998 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-10023555

RESUMO

Different conceptions to revise the licensing regulations for physicians (Approbationsordnung für Arzte) aim to interlock preclinical and clinical subjects. Therefore a more practice-oriented anatomy has to be taught in basic and postgraduate medical education. At the Westfalian Wilhelms University of Münster we established an interdisciplinary anatomical education, executed by clinical lecturers in cooperation with the educational staff of the Department of Anatomy. The intergral element is the comprehensive constitution of clinical anatomy: clinical practitioners of different specialties together with anatomists give lessons in applied anatomy accompanying the dissection course. Clinically experienced lecturers of anatomy guide senior medical students in practical courses, refreshing their anatomical knowledge using particular prosections. These courses correlate with the topics of the distinct clinical tutorials. Conjointly clinical practitioners and anatomists plan, and perform meetings in postgraduate medical education.


Assuntos
Anatomia/educação , Cirurgia Geral/educação , Currículo/tendências , Educação de Pós-Graduação em Medicina/tendências , Previsões , Alemanha , Humanos , Licenciamento em Medicina/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...