Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Med Cases ; 12(3): 90-93, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34434436

RESUMO

Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease that has low survival rate without surgical correction. This report is about a rare case of acute ST elevation myocardial infarction in a 46-year-old patient with uncorrected TOF that was successfully treated with low-dose intracoronary thrombolysis.

2.
Angiology ; 70(8): 756-764, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30665308

RESUMO

OBJECTIVES: To evaluate the angiographic and intravascular ultrasound (IVUS) characteristics of coronary mismatch lesions. BACKGROUND: Better understanding about the characteristics of mismatch lesions may help to achieve more accurate lesion assessment and, thereby, to improve the outcomes of percutaneous coronary intervention (PCI). METHODS: Angiographic and IVUS data from 1369 lesions were analyzed. Mismatch lesion was defined as the difference between proximal and distal reference lumen diameters of ≥1.0 mm or ≥30% of the distal reference lumen diameter. RESULTS: The incidence of mismatch lesions was 20.1% (275/1369). Compared to nonmismatch group, mismatch group had longer lesions (21.3 [6.4] mm vs 18.4 [6.4] mm, P < .001) with smaller minimum lumen diameter (0.87 [0.29] mm vs 1.10 [0.31] mm, P < .001) and more severe diameter stenosis (78.8% [9.2%] vs 66.3% [10.3%], P < .001). On IVUS, mismatch group had larger lumen area (18.7 [5.0] vs 15.8 [5.1] mm2, P < .001) but lower plaque burden at the proximal reference segment (41.0% [9.2%] vs 45.7% [9.9%], P < .001) and smaller lumen area (4.83 [1.89] vs 7.36 [2.89] mm, P < .001) but higher plaque burden at the distal reference segment (42.9% [10.4%] vs 41.4% [10.1%], P = .023). Multivariable logistic regression analysis showed that mismatch lesions were frequently accompanied by diffuse lesions (odds ratio [OR] = 2.50; 95% confidence interval [CI]: 1.83-3.40; P < .001), bifurcation lesions (OR = 5.83; 95% CI: 4.40-7.74; P < .001), and lesions with a low TIMI flow grade (OR = 1.70; 95% CI: 1.08-2.67; P = .022) or severe diameter stenosis (OR = 3.05; 95% CI: 2.10-4.43; P < .001). CONCLUSIONS: Mismatch lesions are quite common and characterized by greater lesion complexity compared with nonmismatch lesions. Further studies may be necessary to address the impact of this lesion type on the outcome of PCI.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/patologia , Vasos Coronários/patologia , Ultrassonografia de Intervenção , Adulto , Idoso , Angiografia Coronária/métodos , Feminino , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Valor Preditivo dos Testes , Ultrassonografia de Intervenção/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...