Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nanosci Nanotechnol ; 10(10): 6855-8, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21137811

RESUMO

Tris(2,2'-bipyridyl)ruthenium (II) (Ru(bpy)2+) electrogerated chemiluminescence (ECL) sensor was fabricated by immobilization of Ru(bpy)2+ complex on conducting polymer@SiO2/Nafion composite film on surface of glassy carbon electrode. The conducting polymer@SiO2 nanocomposites were prepared by coating polyaniline (PANI), polypyrrole (PPy), and polythiophene (PTh) on the surface of the SiO2 sphere. The conducting polymer@SiO2 nanocomposite was characterized by scanning electron microscopy (SEM), Transmission electron microscopy (TEM), and atomic force microscopy (AFM). The sensitivity and reproducibility of the prepared ECL sensor to tripropylamine (TPA) was evaluated. As a result, the PPy@SiO2 composite electrode exhibited high sensitivity and good reproducibility compared to that obtained with PANI@SiO2 and PTh@SiO2 composite electrodes because of the strong interaction between PPy@SiO2 and Ru(bpy)2+ complex.


Assuntos
Polímeros de Fluorcarboneto/química , Medições Luminescentes/métodos , Nanocompostos/química , Dióxido de Silício/química , 2,2'-Dipiridil/análogos & derivados , 2,2'-Dipiridil/química , Técnicas Eletroquímicas , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Nanocompostos/ultraestrutura , Nanotecnologia , Compostos Organometálicos/química , Polímeros/química , Propilaminas/análise , Pirróis/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Sensors (Basel) ; 9(3): 1662-77, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22573979

RESUMO

A COOH-F-MWCNT-Nafion-Ru(bpy)(3) (2+)-Au-ADH electrogenerated chemiluminescence (ECL) electrode using COOH-functionalized MWCNT (COOH-F-MWCNT) and Au nanoparticles synthesized by the radiation method was fabricated for ethanol sensing. A higher sensing efficiency for ethanol for the ECL biosensor prepared by PAAc-g-MWCNT was measured compared to that of the ECL biosensor prepared by PMAc-g-MWCNT, and purified MWCNT. Experimental parameters affecting ethanol detection were also examined in terms of pH and the content of PAAc-g-MWCNT in Nafion. Little interference of other compounds was observed for the assay of ethanol. Results suggest this ECL biosensor could be applied for ethanol detection in real samples.

3.
Sensors (Basel) ; 8(7): 4110-4118, 2008 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-27879925

RESUMO

A modified electrode for hydrogen peroxide (H2O2) sensing was prepared via thiophene (Th) with epoxy group. Thiophene (EpoxyTh) with epoxy group was synthesized by reaction of 3-bromothiophene and glycidyl methacrylate (GMA) in acetonitrile according to Heck Reaction. The electrocopolymerization of Th and EpoxyTh was performed on the surface of indium tin oxide (ITO) electrode by cycling the potential between -1.0 and +2.5 V in mixture of thiophene (Th) and EpoxyTh. Poly(Th-co- EpoxyTh) grown onto the ITO electrode was successfully confirmed by SEM, AFM, and water contact angle analysis, respectively. Finally, the HRP was immobilized on the surface of poly(Th-co-EpoxyTh) electrode by covalent binding. The amperometric response of the HRP-immobilized poly(Th-co-EpoxyTh) electrode for H2O2 was examined by cyclic voltammetry (CV). The HRP-immobilized poly(Th-co-EpoxyTh) electrode showed linearity from 0.1 to 30 mM H2O2, good reproducibility, and long life time.