1.
Analyst ; 138(6): 1660-4, 2013 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-23392529

RESUMO

This communication describes a simple and cost-effective method for fabricating glass microchannels by wet chemical etching using masks made by xurography in vinyl adhesive films. Analytical performance of microfluidic devices fabricated using the new approach was evaluated by microchip electrophoresis coupled to capacitively coupled contactless conductivity detection (C(4)D) and laser-induced fluorescence (LIF) detection.


Assuntos
Eletroforese em Microchip/instrumentação , Vidro/química , Microtecnologia/métodos , Adesivos/química , Desenho de Equipamento
2.
Lab Chip ; 9(1): 115-21, 2009 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-19209343

RESUMO

The fabrication process of novel multichannel microfluidic devices with integrated electrodes for amperometric detection is described. Soft-lithography, lift-off and O(2) plasma surface activation sealing techniques were employed for rapid prototyping of cost effective PDMS/glass microchips. The capabilities of the proposed microdevices were demonstrated by the electrooxidation of hydroquinone and N-acetyl-p-aminophenol (APAP) on a Au working electrode at +800 mV and +700 mV, respectively, against a Au pseudo reference electrode, and of thiocyanate on a Cu working electrode at +700 mV against a Ag/AgCl (KCl saturated) reference electrode. Linear response over the range up to 1.0 mmol L(-1) for APAP and up to 4.0 mmol L(-1) for hydroquinone and thiocyanate were verified through calibration curves with correlation coefficients greater than 0.97 (minimum of five data points). The sensitivities for hydroquinone, thiocyanate, and APAP were 28, 19, and 78 microA mol(-1) L, respectively. Under the experimental conditions used, the estimated limits of detection were 0.21, 0.95, and 0.12 mmol L(-1) for hydroquinone, thiocyanate and APAP, respectively. The geometries of the devices were designed to allow fast calibration procedures and reliable results for in-field applications. Exerting a strong influence over the device performance, the sealing process was greatly enhanced by depositing auxiliary TiSiO(2) thin-films. The general performance of the system was verified by amperometric assays of N-acetyl-p-aminophenol standard solutions, and the influences exerted by the present fabrication methods regarding reproducibility and reliability are addressed. The proposed device was successfully applied in the determination of the concentration of APAP in two commercial formulations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...