Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 747
Filtrar
2.
JACC Adv ; 3(3): 100853, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38938841

RESUMO

Background: Low stroke volume index <35 ml/m2 despite preserved ejection fraction (paradoxical low flow [PLF]) is associated with adverse outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). However, whether the risk associated with PLF is similar in both sexes is unknown. Objectives: The purpose of this study was to analyze the risk associated with PLF in severe aortic stenosis for men and women randomized to TAVR or SAVR. Methods: Patients with ejection fraction ≥50% from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were stratified by sex and treatment arm. The impact of PLF on the 2-year occurrence of the composite of death or heart failure hospitalization (primary endpoint) and of all-cause mortality alone (secondary endpoint) was analyzed. Analysis of variance was used to assess baseline differences between groups. Multivariate Cox regression analysis was used to identify predictors of the endpoint. Results: Out of 2,242 patients, PLF was present in 390 men and 239 women (30% vs 26%, P = 0.06). PLF was associated with a higher rate of NYHA functional class III to IV dyspnea (60% vs 54%, P < 0.001) and a higher prevalence of atrial fibrillation (39% vs 24%, P < 0.001). PLF was a significant predictor of the primary endpoint among women undergoing SAVR in multivariate analysis (adjusted HR: 2.25 [95% CI: 1.14-4.43], P = 0.02) but was not associated with a worse outcome in any of the other groups (all P > 0.05). Conclusions: In women with PLF, TAVR may improve outcomes compared to SAVR. PLF appears to have less impact on outcomes in men.

3.
JACC Adv ; 3(2): 100761, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38939373

RESUMO

Background: A blood multimarker approach may be useful to enhance risk stratification in patients undergoing TAVI. Objectives: The objective of this study was to determine the prognostic value of multiple blood biomarkers in transcatheter aortic valve implantation (TAVI) patients. Methods: In this prospective study, several blood biomarkers of cardiovascular function, inflammation, and renal function were measured in 362 patients who underwent TAVI. The cohort was divided into 3 groups according to the number of elevated blood biomarkers (ie, ≥ median value for the whole cohort) for each patient before the procedure. Survival analyses were conducted to evaluate the association between blood biomarkers and risk of adverse event following TAVI. Results: During a median follow-up of 2.5 (IQR: 1.9-3.2) years, 34 (9.4%) patients were rehospitalized for heart failure, 99 (27%) patients died, and 113 (31.2%) met the composite endpoint of all-cause mortality or heart failure rehospitalization. Compared to patients with 0 to 3 elevated biomarkers (referent group), those with 4 to 7 and 8 to 9 elevated biomarkers had a higher risk of all-cause mortality (HR: 1.54 [95% CI: 0.84-2.80], P = 0.16, and HR: 2.81 [95% CI: 1.53-5.15], P < 0.001, respectively) and of the composite endpoint (HR: 1.65 [95% CI: 0.95-2.84], P = 0.07, and HR: 2.67 [95% CI: 1.52-4.70] P < 0.001, respectively). Moreover, adding the number of elevated blood biomarkers into the clinical multivariable model provided significant incremental predictive value for all-cause mortality (Net Reclassification Index = 0.71, P < 0.001). Conclusions: An increasing number of elevated blood biomarkers is associated with higher risks of adverse clinical outcomes following TAVI. The blood multimarker approach may be helpful to enhance risk stratification in TAVI patients.

4.
JACC Adv ; 3(5): 100959, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38939639

RESUMO

Background: The prognostic value of cardiac damage staging classification based on the extent of extravalvular damage has been proposed in moderate/severe aortic stenosis (AS). Objectives: The purpose of this study was to assess the association of cardiac damage staging with mortality across the spectrum of patients with AS following aortic surgical or transcatheter aortic valve replacement (AVR). Methods: We conducted a pooled meta-analysis of Kaplan-Meier-derived reconstructed time-to-event data from studies published through February 2023. Results: In total, 16 studies (n = 14,499) met our eligibility criteria and included 12,282 patients with symptomatic severe AS and 2,217 patients with asymptomatic severe/moderate AS. For patients with symptomatic severe AS, all-cause mortality was 24.0%, 27.7%, 38.0%, 56.3%, and 57.3% at 5 years in patients with cardiac damage stage 0, 1, 2, 3, and 4, respectively (stage 0 as reference; HR in stage 1: 1.30 [95% CI: 1.03-1.64]; P = 0.029; stage 2: 1.74 [95% CI: 1.41-2.16]; P < 0.001; stage 3: 2.92 [95% CI: 2.35-3.64]; P < 0.001, and stage 4: 3.51 [95% CI: 2.79-4.41]; P < 0.001). For patients with asymptomatic moderate/severe AS, all-cause mortality was 19.3%, 36.9%, 51.7%, and 67.8% at 8 years in patients with cardiac damage stage 0, 1, 2, and 3 to 4, respectively (HR in stage 1: 1.70 [95% CI: 1.21-2.38]; P = 0.002; stage 2: 2.20 [95% CI: 1.60-3.02]; P < 0.001; and stage 3 to 4: 3.90 [95% CI: 2.79-5.47]; P < 0.001). Conclusions: In patients undergoing AVR across the symptomatic and severity spectrum of AS, cardiac damage staging at baseline has important prognostic implications. This pooled meta-analysis in patients undergoing AVR suggests that staging of baseline cardiac damage could be considered for timing and selection of therapy in patients with moderate or severe AS to determine the need for earlier AVR or adjunctive pharmacotherapy to prevent irreversible cardiac damage and improve the long-term prognosis.

5.
J Am Heart Assoc ; 13(12): e035128, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38879450

RESUMO

Cardiac troponin is extensively used as a biomarker in modern medicine due to its diagnostic capability for myocardial injury, as well as its predictive and prognostic value for cardiac diseases. However, heterophile antibodies, antitroponin antibodies, and macrotroponin complexes can be observed both in seemingly healthy individuals and patients with cardiac diseases, potentially leading to false positive or disproportionate elevation of cTn (cardiac troponin) assay results and introducing discrepancies in clinical interpretations with impact on medical management. In this review article, we describe the possible mechanisms of cTn release and the sources of variations in the assessment of circulating cTn levels. We also explore the pathophysiological mechanisms underlying antitroponin antibody development and discuss the influence exerted by macrotroponin complexes on the results of immunoassays. Additionally, we explore approaches to detect these complexes by presenting various clinical scenarios encountered in routine clinical practice. Finally, unsolved questions about the development, prevalence, and clinical significance of cardiac autoantibodies are discussed.


Assuntos
Autoanticorpos , Biomarcadores , Humanos , Biomarcadores/sangue , Autoanticorpos/sangue , Cardiopatias/diagnóstico , Cardiopatias/sangue , Cardiopatias/imunologia , Valor Preditivo dos Testes , Troponina I/sangue , Troponina I/imunologia , Prognóstico
6.
J Am Heart Assoc ; : e034723, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38904242

RESUMO

BACKGROUND: Cardiac amyloidosis (CA) is frequently found in older patients with aortic stenosis (AS). However, the prevalence of AS among patients with CA is unknown. The objective was to study the prevalence and prognostic impact of AS among patients with CA. METHODS AND RESULTS: We conducted a retrospective analysis of a prospective registry comprising 976 patients with native aortic valves who were confirmed with wild type transthyretin amyloid (ATTRwt), hereditary variant transthyretin amyloid (ATTRv), or immunoglobulin light-chain (AL) CA. CA patients' echocardiograms were re-analyzed focusing on the aortic valve. Multivariable Cox regression analysis was performed to assess the mortality risk associated with moderate or greater AS in ATTRwt CA. The crude prevalence of AS among patients with CA was 26% in ATTRwt, 8% in ATTRv, and 5% in AL. Compared with population-based controls, all types of CA had higher age- and sex-standardized rate ratios (SRRs) of having any degree of AS (AL: SRR, 2.62; 95% Confidence Interval (CI) [1.09-3.64]; ATTRv: SRR, 3.41; 95%CI [1.64-4.60]; ATTRwt: SRR, 10.8; 95%CI [5.25-14.53]). Compared with hospital controls, only ATTRwt had a higher SRR of having any degree of AS (AL: SRR, 0.97, 95%CI [0.56-1.14]; ATTRv: SRR, 1.27; 95%CI [0.85-1.44]; ATTRwt: SRR, 4.01; 95%CI [2.71-4.54]). Among patients with ATTRwt, moderate or greater AS was not associated with increased all-cause death after multivariable adjustment (hazard ratio, 0.71; 95%CI [0.42-1.19]; P=0.19). CONCLUSIONS: Among patients with CA, ATTRwt but not ATTRv or AL is associated with a higher prevalence of patients with AS compared with hospital controls without CA, even after adjusting for age and sex. In our population, having moderate or greater AS was not associated with a worse outcome in patients with ATTRwt.

7.
Cardiol Clin ; 42(3): 373-387, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38910022

RESUMO

Self-expanding valves (SEV) and balloon-expandable valves (BEV) for transcatheter aortic valve implantation (TAVI) have their own features. There is a growing interest in long-term outcomes with the adoption of lifetime management in younger patients. To evaluate late outcomes in TAVI with SEV versus BEV, we performed a study-level meta-analysis of reconstructed time-to-event data published by May 31, 2023. We found no statistically significant difference in all-cause death after TAVI with SEV versus BEV. Randomized controlled trials are warranted to validate our results.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Tempo
8.
Ann Cardiothorac Surg ; 13(3): 211-223, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38841078

RESUMO

Prosthesis-patient mismatch (PPM) occurs when the effective orifice area (EOA) of a normally functioning prosthetic valve is too small in relation to the patient's body size. The effect of PPM on outcomes and valve durability have gained credibility, making this an important possibly preventable risk factor. Transcatheter aortic valve replacement (TAVR) generally has a lower incidence of PPM than surgical aortic valve replacement (SAVR). Current surgical literature and randomized trials show an association between severe PPM and mortality in patients with SAVR but there is less evidence for an association with TAVR. Differences in the incidence of PPM may be related to the methods and cutoffs for measuring mismatch. This review will discuss the current state of field and propose standardization of measurement methods which may more accurately risk stratify patients.

9.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38866455

RESUMO

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco , Idoso , Fatores de Tempo , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Medição de Risco , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Estados Unidos/epidemiologia
10.
Curr Opin Cardiol ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38899782

RESUMO

PURPOSE OF REVIEW: Subclinical leaflet thrombosis (SLT) is often an incidental finding characterized by a thin layer of thrombus involving one, two or three leaflets, with typical appearance on multi-detector computed tomography (MDCT) of hypo-attenuating defect at the aortic side of the leaflet, also called hypo-attenuating leaflet thickening (HALT). SLT may occur following both transcatheter aortic replacement (TAVR) or biological surgical aortic valve replacement (SAVR). The aim of this review is to present an overview of the current state of knowledge on the incidence, diagnosis, clinical impact, and management of SLT following TAVR or SAVR. RECENT FINDINGS: SLT occurs in 10-20% of patients following TAVR and is somewhat more frequent than following SAVR (5-15%). SLT may regress spontaneously without treatment in about 50% of the cases but may also progress to clinically significant valve thrombosis in some cases. Oral anticoagulation with vitamin K antagonist is reasonable if SLT is detected by echocardiography and/or MDCT during follow-up and is generally efficient to reverse SLT. SLT is associated with mild increase in the risk of stroke but has no impact on survival. SLT has been linked with accelerated structural valve deterioration and may thus impact valve durability and long-term outcomes. SUMMARY: SLT is often an incidental finding on echocardiography or MDCT that occurs in 10-20% of patients following TAVR or 5-15% following biological SAVR and is associated with a mild increase in the risk of thrombo-embolic event with no significant impact on mortality but may be associated with reduced valve durability.

11.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747561

RESUMO

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38693866

RESUMO

AIMS: Evaluation of left and right ventricular longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and right ventricular longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30-days and 1-year after aortic valve replacement (AVR). METHODS AND RESULTS: LV longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER-2A surgical AVR (SAVR) arm (n=985) and from the PARTNER-2 SAPIEN-3 registry (n=719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline were associated with increased risk of the composite of death, hospitalization, and stroke at 5-years (Adjusted-HRs for LV LS<15%: 1.24 95%CI 1.05-1.45, p=0.001; TAPSE<14mm: 1.44 95%CI 1.21-1.73, p<0.001; RV/PA coupling<0.55mm/mmHg: 1.32 95% CI 1.07-1.63, p=0.011). Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5-years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95%CI 1.08-1.68, p=0.009) but not with TAVR (HR: 1.12, 95%CI 0.88-1.42). Lower RV-PA coupling at 30-days showed the strongest association with cardiac mortality. CONCLUSION: SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30-days were associated with inferior clinical outcomes at 5-years. In patients with LVEF<50%, TAVR was associated with superior 5-year outcomes.

13.
J Am Heart Assoc ; 13(9): e033872, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38700000

RESUMO

BACKGROUND: The mortality risk attributable to moderate aortic stenosis (AS) remains incompletely characterized and has historically been underestimated. We aim to evaluate the association between moderate AS and all-cause death, comparing it with no/mild AS (in a general referral population and in patients with heart failure with reduced ejection fraction). METHODS AND RESULTS: A systematic review and pooled meta-analysis of Kaplan-Meier-derived reconstructed time-to-event data of studies published by June 2023 was conducted to evaluate survival outcomes among patients with moderate AS in comparison with individuals with no/mild AS. Ten studies were included, encompassing a total of 409 680 patients (11 527 with moderate AS and 398 153 with no/mild AS). In the overall population, the 15-year overall survival rate was 23.3% (95% CI, 19.1%-28.3%) in patients with moderate AS and 58.9% (95% CI, 58.1%-59.7%) in patients with no/mild aortic stenosis (hazard ratio [HR], 2.55 [95% CI, 2.46-2.64]; P<0.001). In patients with heart failure with reduced ejection fraction, the 10-year overall survival rate was 15.5% (95% CI, 10.0%-24.0%) in patients with moderate AS and 37.3% (95% CI, 36.2%-38.5%) in patients with no/mild AS (HR, 1.83 [95% CI, 1.69-2.0]; P<0.001). In both populations (overall and heart failure with reduced ejection fraction), these differences correspond to significant lifetime loss associated with moderate AS during follow-up (4.4 years, P<0.001; and 1.9 years, P<0.001, respectively). A consistent pattern of elevated mortality rate associated with moderate AS in sensitivity analyses of matched studies was observed. CONCLUSIONS: Moderate AS was associated with higher risk of death and lifetime loss compared with patients with no/mild AS.


Assuntos
Estenose da Valva Aórtica , Humanos , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Medição de Risco/métodos , Fatores de Risco , Volume Sistólico/fisiologia , Causas de Morte , Fatores de Tempo , Feminino , Idoso , Masculino
17.
Artigo em Inglês | MEDLINE | ID: mdl-38688452

RESUMO

OBJECTIVES: Randomized controlled trials comparing transcatheter aortic valve implantation with surgical aortic valve replacement demonstrate conflicting evidence, particularly in low-risk patients. We aim to reevaluate the evidence using trial sequential analysis, balancing type I and II errors, and compare with conventional meta-analysis. METHODS: Databases were searched for randomized controlled trials, which were divided into higher-risk and lower-risk randomized controlled trials according to a pragmatic risk classification. Primary outcomes were death and a composite end point of death or disabling stroke assessed at 1 year and maximum follow-up. Conventional meta-analysis and trial sequential analysis were performed, and the required information size was calculated considering a type I error of 5% and a power of 90%. RESULTS: Eight randomized controlled trials (n = 5274 higher-risk and 3661 lower-risk patients) were included. Higher-risk trials showed no significant reduction in death at 1 year with transcatheter aortic valve implantation (relative risk, 0.93, 95% CI, 0.81-1.08, P = .345). Lower-risk trials suggested lower death risk on conventional meta-analysis (relative risk, 0.67, 95% CI, 0.47-0.96, P = .031), but trial sequential analysis indicated potential spurious evidence (P = .116), necessitating more data for conclusive benefit (required information size = 5944 [59.8%]). For death or disabling stroke at 1 year, higher-risk trials lacked evidence (relative risk, 0.90, 95% CI, 0.79-1.02, P = .108). In lower-risk trials, transcatheter aortic valve implantation indicated lower risk in conventional meta-analysis (relative risk, 0.68, 95% CI, 0.50-0.93, P = .014), but trial sequential analysis suggested potential spurious evidence (P = .053), necessitating more data for conclusive benefit (required information size = 5122 [69.4%]). Follow-up results provided inconclusive evidence for both primary outcomes across risk categories. CONCLUSIONS: Conventional meta-analysis methods may have prematurely declared an early reduction of negative outcomes after transcatheter aortic valve implantation when compared with surgical aortic valve replacement.

19.
Can J Cardiol ; 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38518892

RESUMO

BACKGROUND: Angiotensin receptor blockers (ARBs) may slow down the progression of aortic stenosis (AS) through their antifibrotic effect. Women present more valvular fibrosis than men, so ARBs may have more effect in females. Our aim was to assess the impact of ARBs on the remodelling of the aortic valve in men and women. METHODS: We included patients who had an aortic valve replacement with or without coronary bypass grafting from 2006 to 2013. Patients with missing echocardiographic or histologic data were excluded. Warren-Yong and fibrosis scores of the explanted valves were performed. Patients were divided into 4 phenotypes according to their Warren-Yong and fibrosis scores: mild calcification/fibrosis, severe calcification/fibrosis group, predominant fibrosis group, predominant calcification group. RESULTS: Among the 1321 included patients, the vast majority (89%) has severe AS. Patients in the predominant fibrosis group, compared with the predominant calcium group, were more often female (39% vs 31%; P = 0.008) with bicuspid valves (44% vs 34%; P = 0.002), and less often used ARBs (25% vs 30%; P = 0.046). Female sex was independently associated with being in the predominant fibrosis group (odds ratio 1.45, 95% confidence interval 1.08-1.95; P = 0.01), with a significant interaction between female sex and ARBs. Women taking ARBs compared with women not taking ARBs had significantly lower fibrosis scores (P < 0.001). This difference was not seen in men. CONCLUSIONS: In this large series of patients with moderate-severe AS, among the women there was a negative association between intake of ARBs and valvular fibrosis. Thus, the possible effects of ARBs may be sex specific, with a larger therapeutic role in women.

20.
Nat Commun ; 15(1): 2407, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38494474

RESUMO

There is currently no medical therapy to prevent calcific aortic valve stenosis (CAVS). Multi-omics approaches could lead to the identification of novel molecular targets. Here, we perform a genome-wide association study (GWAS) meta-analysis including 14,819 cases among 941,863 participants of European ancestry. We report 32 genomic loci, among which 20 are novel. RNA sequencing of 500 human aortic valves highlights an enrichment in expression regulation at these loci and prioritizes candidate causal genes. Homozygous genotype for a risk variant near TWIST1, a gene involved in endothelial-mesenchymal transition, has a profound impact on aortic valve transcriptomics. We identify five genes outside of GWAS loci by combining a transcriptome-wide association study, colocalization, and Mendelian randomization analyses. Using cross-phenotype and phenome-wide approaches, we highlight the role of circulating lipoproteins, blood pressure and inflammation in the disease process. Our findings pave the way for the development of novel therapies for CAVS.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valva Aórtica/patologia , Calcinose , Humanos , Valva Aórtica/metabolismo , Estudo de Associação Genômica Ampla , Estenose da Valva Aórtica/genética , Genômica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...