Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Abdom Radiol (NY) ; 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38831073

RESUMO

As the use of cross-sectional abdominal and pelvic imaging has increased exponentially in the past several decades, incidental musculoskeletal findings have become commonplace. These are often unrelated to the indication for the examination and are frequently referred to as the "radiologist's blind spot" on these studies. The differential diagnosis for abnormalities of the paraspinal and pelvic musculature is, in many cases, quite different from the anterior abdominal wall muscles. Furthermore, due to their relatively deep location, pathology involving the former muscle groups is more likely to be clinically occult, often presenting only incidentally when the patient undergoes cross-sectional imaging. Effective treatment of diseases of these muscles is dependent on adherence to a diverse set of diagnostic and treatment algorithms. The purpose of this review article is to familiarize the radiologist with the unique pathology of these often-overlooked muscles of the abdomen and pelvis.

2.
Radiol Med ; 123(12): 918-925, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30084109

RESUMO

PURPOSE: To assess quantitative and qualitative effects of kVp on oral contrast density. MATERIALS AND METHODS: Three readers retrospectively reviewed 100 CT scans performed at a range of high- and low-energy settings, independently determining their preferred window and level settings for evaluation of the oral-contrast-opacified bowel. Contrast density was also assessed quantitatively in the stomach, jejunum, and ileum. Subsequently, a range of oral contrast dilutions were imaged at varying kVp's in a commercially available CIRS tissue equivalent phantom model. RESULTS: In the retrospective patient study, mean oral contrast density increased significantly in the ileum compared to the jejunum (455.2 and 308.8 HU, respectively, p < 0.01). Similar findings were seen in patients regardless of patients' weight. Mean oral contrast density was higher on lower-energy scans, requiring more window/level adjustment. An oral contrast iodine concentration of 5.82-7.77 mg I/mL most closely approximated a target oral contrast density of 200 HU. CONCLUSIONS: Oral contrast density is strongly influenced by kVp, supporting use of more dilute oral contrast when using lower-kVp techniques.


Assuntos
Meios de Contraste/administração & dosagem , Meios de Contraste/farmacocinética , Trato Gastrointestinal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Administração Oral , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos
3.
J Comput Assist Tomogr ; 42(5): 727-729, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29787499

RESUMO

We present a case of appendicitis within a De Garengeot hernia. The patient presented to the emergency department with 4 days of worsening abdominal pain. Computed tomography examination revealed an inflamed appendix within a femoral hernia. The patient underwent appendectomy and repair of the femoral defect. Pathological examination was consistent with acute appendicitis. De Garengeot hernia is a rare phenomenon, with less than 5% of femoral hernias containing the appendix and 0.08% to 0.13% containing an incarcerated acute appendicitis.


Assuntos
Apendicite/complicações , Apendicite/diagnóstico por imagem , Hérnia Femoral/complicações , Hérnia Femoral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Idoso , Apendicite/cirurgia , Diagnóstico Diferencial , Feminino , Hérnia Femoral/cirurgia , Humanos
5.
Clin Imaging ; 49: 44-47, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29127876

RESUMO

OBJECTIVE: To identify performance of imaging features in differentiating hepatic cysts from biliary cystadenomas of the liver. METHODS: 25 pathologically confirmed hepatic cystic lesions (hepatic cysts or biliary cystadenomas) were evaluated retrospectively and predetermined imaging features assessed for performance in differentiation. RESULTS: Any septation which arose from a cyst wall without external indentation had a very high association with biliary cystadenoma, while the presence of a thick septation had only a moderate association. CONCLUSIONS: The relationship between septations and the wall of the cystic lesion performed better than previously reported features including thick septations.


Assuntos
Neoplasias do Sistema Biliar/diagnóstico , Sistema Biliar/patologia , Cistadenoma/diagnóstico , Cistos/diagnóstico , Hepatopatias/diagnóstico , Fígado/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Biliares , Neoplasias do Sistema Biliar/patologia , Cistadenoma/patologia , Cistos/patologia , Diagnóstico Diferencial , Feminino , Humanos , Hepatopatias/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
Eur J Radiol ; 85(4): 695-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26971410

RESUMO

OBJECTIVES: To evaluate optimal window settings for display of virtual monoenergetic reconstructions in third-generation dual-source, dual-energy computed tomography (DECT) of the liver. METHODS: Twenty-nine subjects were prospectively evaluated with DECT in arterial (AP) and portal venous (PVP) phases. Three reconstructed datasets were calculated: standard linearly-blended (LB120), 70-keV standard virtual monoenergetic (M70), and 50-keV advanced image-based virtual monoenergetic (M50+). Two readers assessed optimal window settings (width and level, W/L), establishing a mean for each reconstruction which was used for a blinded assessment of liver lesions. RESULTS: The optimal W/L for M50+ were significantly higher for both AP (W=429.3 ± 44.6 HU, L=129.4 ± 9.7 HU) and PVP (W=376.1 ± 14.2HU, L=146.6 ± 7.0 HU) than for LB120 (AP, W=215.9 ± 16.9 HU, L=82.3 ± 9.4 HU) (PVP, W=173.4 ± 8.9 HU, L=69.3 ± 6.0 HU) and M70 (AP, W=247.1 ± 22.2 HU, L=72.9 ± 6.8 HU) (PVP, W=232.0 ± 27.9 HU, L=91.6 ± 14.4 HU). Use of the optimal window setting for M50+ vs. LB120 resulted in higher sensitivity (AP, 100% vs. 86%; PVP, 96% vs. 63%). CONCLUSIONS: Application of dedicated window settings results in improved liver lesion detection rates in advanced image-based virtual monoenergetic DECT when customized for arterial and portal venous phases.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
J Comput Assist Tomogr ; 39(5): 716-20, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26196343

RESUMO

PURPOSE: To compare image quality on contrast-enhanced dual-energy computed tomography (DECT) during the pancreatic parenchymal phase of pancreatic masses between linearly-blended simulated 120 kVp images (routine) and advanced image-based virtual monoenergetic reconstructions at 55 keV. METHODS: This was a retrospective evaluation of 24 nonconsecutive adults found to have a focal pancreatic mass on a multiphasic abdominal dual-source DECT (12 adenocarcinoma, 5 neuroendocrine, 7 cystic tumors). For pancreatic-parenchymal phase images, subjects had routine and 55 keV images reconstructed at the time of clinical evaluation. Quantitative evaluation by contrast-to-noise ratio and qualitative evaluations of image quality by (1) direct comparison of image pairs (preference) and (2) blinded assessment of image quality measures based on Likert scores were performed. RESULTS: Mean patient weight was 205.8 ± 26.6 lbs. Mean pancreatic lesion contrast-to-noise ratio was significantly higher at 55 keV (6.8 ± 4.1) compared to the routine image series (5.8 ± 3.8; P = 0.0002). All 3 readers preferred the 55-keV images over routine blended images in 70.1% to 95.8% of cases. No significant differences were observed for subjective sharpness of the mass, visualization of internal mass structures, or image noise. CONCLUSIONS: Use of a single advanced image-based virtual monoenergetic reconstruction at 55 keV in pancreatic DECT showed improved objective image quality and reader preference compared to routine images. As this image reconstruction can be incorporated into the scan protocol, this technique should be considered for routine clinical use.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Aumento da Imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído
8.
Clin Imaging ; 39(4): 642-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25794849

RESUMO

OBJECTIVE: To compare the radiographic density of renal cysts on contrast-enhanced computed tomography (CT) scans performed at tube voltages of 100 versus 120 kVp. METHODS: Thirty-six renal cysts from contrast-enhanced CT performed on 21 subjects at both 120 kVp and 100 kVp were compared by Kolmogorov-Smirnov statistical testing. RESULTS: The radiographic density (mean+/-standard deviation in Hounsfield units) of cysts was greater on 100-kVp than on 120-kVp CT scans for both 5-mm and 2-mm reconstructed slice thicknesses: 16.6+/-5.6 versus 10.9+/-4.9 and 14.1+/-5.6 versus 8.5+/-3.9, respectively. CONCLUSIONS: Decrease in tube voltage significantly increases measured radiographic density of renal cysts on CT. Further studies are indicated to assess the clinical impact of lower-tube-voltage CT.


Assuntos
Doenças Renais Císticas/diagnóstico por imagem , Meios de Contraste , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
9.
BMJ Case Rep ; 20132013 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-23843415

RESUMO

A 44-year-old woman presented with a large pelvic mass. Pathology revealed a granulosa cell tumour of the left ovary. The patient was followed after surgery with inhibin B levels and interval imaging. Six years later, she began to experience severe back pain. A vertebral biopsy was positive for metastatic granulosa cell tumour. She underwent radiation to the spine. Inhibin B levels began to rise and, several months later, a CT scan showed a large heterogeneous mass essentially replacing the left kidney. She underwent an open left radical nephrectomy. Pathology revealed a 12 cm cystic nephroma with a 5 cm nodule of metastatic granulosa cell tumour. Immunohistochemistry demonstrated that the mass was inhibin and oestrogen receptor positive. This is a novel presentation of these coexisting pathologies. This unique case sheds light on the possibility of induction of cystic nephroma by the altered hormonal environment created by a granulosa cell tumour metastasis.


Assuntos
Tumor de Células da Granulosa/secundário , Neoplasias Renais/secundário , Neoplasias Ovarianas/patologia , Adulto , Feminino , Tumor de Células da Granulosa/complicações , Humanos , Doenças Renais Císticas/etiologia , Neoplasias Renais/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...