Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 622
Filtrar
1.
J Am Heart Assoc ; : e034500, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39011955

RESUMO

BACKGROUND: Shock-reduction implantable cardioverter-defibrillator programming (SRP) was associated with fewer therapies and improved survival in randomized controlled trials, but real-world studies investigating SRP and associated outcomes are limited. METHODS AND RESULTS: The BIOTRONIK CERTITUDE registry was linked with the Medicare database. We included all patients with an implantable cardioverter-defibrillator implanted between August 22, 2012 and September 30, 2021 in the United States. SRP was defined as programming to either a therapy rate cutoff ≥188 beats per minute or number of intervals to detection ≥30/40 for treatment. Among 6781 patients (mean 74±9 years; 27% women), 3393 (50%) had SRP. Older age, secondary prevention indication, and device implantation in the southern or western United States were associated with lower use of SRP. The cumulative incidence rate of implantable cardioverter-defibrillator shocks was lower in the SRP group (5.1% shocks/patient year) compared with the non-SRP group (7.2% shocks/patient year) (adjusted hazard ratio [HR], 0.83 [95% CI, 0.73-0.96]; P=0.005). Over a median follow-up of 2.9 years, 739 deaths occurred in the SRP group and 822 deaths occurred in the non-SRP group (adjusted HR, 0.97 [95% CI, 0.88-1.07]; P=0.569). SRP was associated with a lower all-cause mortality among patients without ischemic heart disease compared with patients with ischemic heart disease (adjusted HR, 0.64 [95% CI, 0.48-0.87] versus adjusted HR, 1.02 [95% CI, 0.92-1.14]; Pinteraction=0.004). CONCLUSIONS: Adoption of SRP is low in real-world clinical practice. Age, clinical variables, and geographic factors are associated with use of SRP. In this study, SRP-associated decrease in mortality was limited to patients without ischemic heart disease.

2.
Circ Cardiovasc Interv ; 17(6): e013466, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38889251

RESUMO

BACKGROUND: Procedure volumes are associated with outcomes for many cardiovascular procedures, leading to guidelines on minimum volume thresholds for certain procedures; however, the volume-outcome relationship with left atrial appendage occlusion is poorly understood. As such, we sought to determine the relationship between hospital and physician volume and WATCHMAN left atrial appendage occlusion procedural success overall and with the new generation WATCHMAN FLX device. METHODS: We performed an analysis of WATCHMAN procedures (January 2019 to October 2021) from the National Cardiovascular Data Registry LAAO Registry. Three-level hierarchical generalized linear models were used to assess the adjusted relationship between procedure volume and procedural success (device released with peridevice leak <5 mm, no in-hospital major adverse events). RESULTS: Among 87 480 patients (76.2±8.0 years; 58.8% men; mean CHA2DS2-VASc score, 4.8±1.5) from 693 hospitals, the procedural success rate was 94.2%. With hospital volume Q4 (greatest volume) as the reference, the likelihood of procedural success was significantly less among Q1 (odds ratio [OR], 0.66 [CI, 0.57-0.77]) and Q2 (OR, 0.78 [CI, 0.69-0.90]) but not Q3 (OR, 0.95 [CI, 0.84-1.07]). With physician volume Q4 (greatest volume) as the reference, the likelihood of procedural success was significantly less among Q1 (OR, 0.72 [CI, 0.63-0.82]), Q2 (OR, 0.79 [CI, 0.71-0.89]), and Q3 (OR, 0.88 [CI, 0.79-0.97]). Among WATCHMAN FLX procedures, there was attenuation of the volume-outcome relationships, with statistically significant but modest absolute differences of only ≈1% across volume quartiles. CONCLUSIONS: In this contemporary national analysis, greater hospital and physician WATCHMAN volumes were associated with increased procedure success. The WATCHMAN FLX transition was associated with increased procedural success and less heterogeneity in outcomes across volume quartiles. These findings indicate the importance of understanding the volume-outcome relationship for individual left atrial appendage occlusion devices.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Hospitais com Alto Volume de Atendimentos , Hospitais com Baixo Volume de Atendimentos , Sistema de Registros , Humanos , Apêndice Atrial/fisiopatologia , Feminino , Masculino , Idoso , Resultado do Tratamento , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/cirurgia , Idoso de 80 Anos ou mais , Estados Unidos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Fatores de Risco , Medição de Risco , Fatores de Tempo , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Função do Átrio Esquerdo
3.
Heart Rhythm ; 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38878939

RESUMO

BACKGROUND: Advances in leadless pacemaker technology have enabled accelerometer-based atrioventricular (AV) synchronous pacing by sensing atrial mechanical contraction. OBJECTIVE: The purpose of this study was to report the performance of the Micra AV leadless pacemaker from the worldwide Micra AV post-approval registry (PAR) through 12 months. METHODS: The Micra AV PAR is a prospective, single-arm, observational registry designed to assess the safety and effectiveness of Micra AV in a real-world setting. For the present interim analysis, major complications and system revisions through 12 months were summarized and compared to a historical cohort of 2667 patients implanted with a transvenous dual-chamber pacing system. RESULTS: The device was successfully implanted in 796 of 801 patients (99.4%) at 97 centers in 19 countries. Micra AV patients were older (74.1 years vs 71.1 years; P < .0001) with a higher incidence of renal disease (22.3% vs 9.8%; P < .0001) compared with transvenous dual-chamber patients. Through 12 months, the major complication rate was 3.7% in Micra AV patients compared with 8.8% in transvenous dual-chamber patients (hazard ratio 0.42; 95% confidence interval 0.28-0.61; P < .001). The system revision rate was 1.5% in Micra AV patients compared with 5.5% for transvenous dual-chamber patients (hazard ratio 0.25; 95% confidence interval 0.13-0.47; P < .001); this reduction was largely driven by the absence of lead dislodgments requiring revision. The median AV synchrony index was 79.4% (interquartile range 65.2%-86.4%) in patients paced >90%. CONCLUSION: The Micra AV leadless pacemaker was implanted with a high rate of success in patients with multiple comorbidities, with a significantly lower rate of complications and system revisions through 12 months compared to a historical cohort of patients with transvenous dual-chamber pacemakers.

4.
Heart Rhythm ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38848862

RESUMO

BACKGROUND: In patients with a history of stroke or those at high risk for developing stroke, a continuous rhythm monitoring strategy using an implantable loop recorder (ILR) is often performed to screen for atrial fibrillation (AF). OBJECTIVES: The purpose of this study was to perform a systematic review (MEDLINE and EMBASE) including randomized controlled trials comparing ILR-based continuous rhythm monitoring vs usual care in patients with a history of stroke or patients at high risk for developing stroke. METHODS: A meta-analysis was performed, and aggregate risk ratio (RR) and risk difference (RD) with 95% confidence interval (CI) were calculated. RESULTS: Four randomized controlled trials with 7237 patients (ILR 2114, non-ILR 5123) were included. ILR vs non-ILR was associated with increased detection of incident AF (RR 3.88; 95% CI 2.23-6.75; P <.00001; number needed to treat [NNT] = 7.7; I2 = 61%), increased appropriate initiation of anticoagulation (RR 2.29; 95% CI 2.07-2.55; P <.00001; NNT = 6.7; I2 = 0), and a 25% lower risk of developing stroke (RR 0.75; 95% CI 0.59-0.95]; P = .02; NNT = 100; I2 = 0%). In patients with history of stroke there was no difference in the risk of developing incident stroke (RR 0.83; 95% CI 0.61-1.14]; P = .25; I2 = 0%). CONCLUSION: Our meta-analysis showed that screening for AF with ILR is associated with increased detection of AF and increased initiation of appropriate anticoagulation therapy in patients with a history of stroke or those with risk factors for stroke. The benefit of stroke risk reduction with ILR remains unclear, and future studies focused on the inclusion of patients without a history of stroke are needed to elucidate this uncertainty.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38842977

RESUMO

BACKGROUND: New-onset atrial fibrillation (NOAF) occurs in 5% to 15% of patients who undergo transfemoral transcatheter aortic valve replacement (TAVR). Cardiac imaging has been underutilized to predict NOAF following TAVR. OBJECTIVES: The objective of this analysis was to compare and assess standard, manual echocardiographic and cardiac computed tomography (cCT) measurements as well as machine learning-derived cCT measurements of left atrial volume index and epicardial adipose tissue as risk factors for NOAF following TAVR. METHODS: The study included 1,385 patients undergoing elective, transfemoral TAVR for severe, symptomatic aortic stenosis. Each patient had standard and machine learning-derived measurements of left atrial volume and epicardial adipose tissue from cardiac computed tomography. The outcome of interest was NOAF within 30 days following TAVR. We used a 2-step statistical model including random forest for variable importance ranking, followed by multivariable logistic regression for predictors of highest importance. Model discrimination was assessed by using the C-statistic to compare the performance of the models with and without imaging. RESULTS: Forty-seven (5.0%) of 935 patients without pre-existing atrial fibrillation (AF) experienced NOAF. Patients with pre-existing AF had the largest left atrial volume index at 76.3 ± 28.6 cm3/m2 followed by NOAF at 68.1 ± 26.6 cm3/m2 and then no AF at 57.0 ± 21.7 cm3/m2 (P < 0.001). Multivariable regression identified the following risk factors in association with NOAF: left atrial volume index ≥76 cm2 (OR: 2.538 [95% CI: 1.165-5.531]; P = 0.0191), body mass index <22 kg/m2 (OR: 4.064 [95% CI: 1.500-11.008]; P = 0.0058), EATv (OR: 1.007 [95% CI: 1.000-1.014]; P = 0.043), aortic annulus area ≥659 mm2 (OR: 6.621 [95% CI: 1.849-23.708]; P = 0.004), and sinotubular junction diameter ≥35 mm (OR: 3.891 [95% CI: 1.040-14.552]; P = 0.0435). The C-statistic of the model was 0.737, compared with 0.646 in a model that excluded imaging variables. CONCLUSIONS: Underlying cardiac structural differences derived from cardiac imaging may be useful in predicting NOAF following transfemoral TAVR, independent of other clinical risk factors.

7.
J Am Heart Assoc ; 13(9): e030679, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38700039

RESUMO

BACKGROUND: Obstructive sleep apnea (OSA) contributes to the generation, recurrence, and perpetuation of atrial fibrillation, and it is associated with worse outcomes. Little is known about the economic impact of OSA therapy in atrial fibrillation. This retrospective cohort study assessed the impact of positive airway pressure (PAP) therapy adherence on health care resource use and costs in patients with OSA and atrial fibrillation. METHODS AND RESULTS: Insurance claims data for ≥1 year before sleep testing and 2 years after device setup were linked with objective PAP therapy use data. PAP adherence was defined from an extension of the US Medicare 90-day definition. Inverse probability of treatment weighting was used to create covariate-balanced PAP adherence groups to mitigate confounding. Of 5867 patients (32% women; mean age, 62.7 years), 41% were adherent, 38% were intermediate, and 21% were nonadherent. Mean±SD number of all-cause emergency department visits (0.61±1.21 versus 0.77±1.55 [P=0.023] versus 0.95±1.90 [P<0.001]), all-cause hospitalizations (0.19±0.69 versus 0.24±0.72 [P=0.002] versus 0.34±1.16 [P<0.001]), and cardiac-related hospitalizations (0.06±0.26 versus 0.09±0.41 [P=0.023] versus 0.10±0.44 [P=0.004]) were significantly lower in adherent versus intermediate and nonadherent patients, as were all-cause inpatient costs ($2200±$8054 versus $3274±$12 065 [P=0.002] versus $4483±$16 499 [P<0.001]). All-cause emergency department costs were significantly lower in adherent and intermediate versus nonadherent patients ($499±$1229 and $563±$1292 versus $691±$1652 [P<0.001 and P=0.002], respectively). CONCLUSIONS: These data suggest clinical and economic benefits of PAP therapy in patients with concomitant OSA and atrial fibrillation. This supports the value of diagnosing and managing OSA and highlights the need for strategies to enhance PAP adherence in this population.


Assuntos
Fibrilação Atrial , Pressão Positiva Contínua nas Vias Aéreas , Apneia Obstrutiva do Sono , Humanos , Feminino , Fibrilação Atrial/terapia , Fibrilação Atrial/economia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/diagnóstico , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/economia , Apneia Obstrutiva do Sono/epidemiologia , Pressão Positiva Contínua nas Vias Aéreas/economia , Estados Unidos/epidemiologia , Recursos em Saúde/estatística & dados numéricos , Recursos em Saúde/economia , Custos de Cuidados de Saúde/estatística & dados numéricos , Hospitalização/economia , Hospitalização/estatística & dados numéricos , Cooperação do Paciente/estatística & dados numéricos , Resultado do Tratamento
9.
J Am Heart Assoc ; 13(11): e028951, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38780169

RESUMO

BACKGROUND: Days alive out of hospital (DAOH) is an objective and patient-centered net benefit end point. There are no assessments of DAOH in clinical trials of interventions for atrial fibrillation (AF), and it is not known whether this end point is of clinical utility in these populations. METHODS AND RESULTS: ROCKET AF (Rivaroxaban Once Daily Oral Direct Factor Xa Inhibition Compared With Vitamin K Antagonism for Prevention of Stroke and Embolism Trial in Atrial Fibrillation) was an international double-blind, double-dummy randomized clinical trial that compared rivaroxaban with warfarin in patients with atrial fibrillation at increased risk for stroke. We assessed DAOH using investigator-reported event data for up to 12 months after randomization in ROCKET AF. We assessed DAOH overall, by treatment group, and by subgroup, including age, sex, and comorbidities, using Poisson regression. The mean±SD number of days dead was 7.3±41.2, days hospitalized was 1.2±7.2, and mean DAOH was 350.7±56.2, with notable left skew. Patients with comorbidities had fewer DAOH overall. There were no differences in DAOH by treatment arm, with mean DAOH of 350.6±56.5 for those randomized to rivaroxaban and 350.7±55.8 for those randomized to warfarin (P=0.86). A sensitivity analysis found no difference in DAOH not disabled with rivaroxaban versus warfarin (DAOH not disabled, 349.2±59.5 days and 349.1 days±59.3 days, respectively, P=0.88). CONCLUSIONS: DAOH did not identify a treatment difference between patients randomized to rivaroxaban versus warfarin. This may be driven in part by the low overall event rates in atrial fibrillation anticoagulation trials, which leads to substantial left skew in measures of DAOH.


Assuntos
Anticoagulantes , Fibrilação Atrial , Inibidores do Fator Xa , Rivaroxabana , Acidente Vascular Cerebral , Varfarina , Humanos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Rivaroxabana/uso terapêutico , Rivaroxabana/administração & dosagem , Feminino , Masculino , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , Idoso , Varfarina/uso terapêutico , Inibidores do Fator Xa/uso terapêutico , Inibidores do Fator Xa/administração & dosagem , Anticoagulantes/uso terapêutico , Anticoagulantes/administração & dosagem , Método Duplo-Cego , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Morfolinas/uso terapêutico , Tiofenos/uso terapêutico , Idoso de 80 Anos ou mais
10.
Circ Arrhythm Electrophysiol ; 17(5): e012697, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38629286

RESUMO

BACKGROUND: Clinically detected atrial fibrillation (AF) is associated with a significant increase in mortality and other adverse cardiovascular events. Since the advent of effective methods for AF rhythm control, investigators have attempted to determine how much these adverse prognostic AF effects could be mitigated by the restoration of sinus rhythm (SR) and whether the method used mattered. METHODS: The CABANA trial (Catheter Ablation versus Antiarrhythmic Drug Therapy for Atrial Fibrillation) randomized 2204 AF patients to ablation versus drug therapy, of which 1240 patients were monitored in follow-up using the CABANA ECG rhythm monitoring system. To assess the prognostic benefits of SR, we performed a prespecified analysis using Cox survival modeling with heart rhythm as a time-dependent variable and randomized treatment group as a stratification factor. RESULTS: In the 1240 patient study cohort, 883 (71.2%) had documented AF at some point during their postblanking follow-up. Among the 883 patients, 671 (76.0%) experienced AF within the first year of postblanking follow-up, and 212 (24.0%) experienced their first AF after ≥1 year of postblanking follow-up. The primary CABANA end point (death, disabling stroke, serious bleeding, or cardiac arrest) occurred in 95 (10.8%) of the 883 patients with documented AF and in 29 (8.1%) of the 357 patients with no AF recorded during follow-up. In multivariable time-dependent analysis, the presence of SR (compared with non-SR) was associated with a significantly reduced risk of the primary end point (adjusted hazard ratio, 0.57 [95% CI, 0.38-0.85]; P=0.006; independent of treatment strategy [ablation versus drugs]). Corresponding results for all-cause mortality were adjusted hazard ratio of 0.59 [95% CI, 0.35-1.01]; P=0.053). CONCLUSIONS: In patients in the CABANA trial with detailed long-term rhythm follow-up, increased time in SR was associated with a clinically consequential decrease in mortality and other adverse prognostic events. The predictive value of SR was independent of the therapeutic approach responsible for reducing the burden of detectable AF. REGISTRATION: URL: https://clinicaltrials.gov; Unique Identifier: NCT00911508.


Assuntos
Antiarrítmicos , Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/terapia , Masculino , Feminino , Antiarrítmicos/uso terapêutico , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Prognóstico , Medição de Risco , Eletrocardiografia Ambulatorial , Potenciais de Ação
11.
Heart Rhythm ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38597857

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society.

12.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Catéteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
13.
JACC Clin Electrophysiol ; 10(5): 930-940, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38661602

RESUMO

BACKGROUND: Postoperative atrial fibrillation (POAF) is associated with increased morbidity and mortality. Epicardial injection of botulinum toxin may suppress POAF. OBJECTIVES: This study sought to assess the safety and efficacy of AGN-151607 for the prevention of POAF after cardiac surgery. METHODS: This phase 2, randomized, placebo-controlled trial assessed the safety and efficacy of AGN-151607, 125 U and 250 U vs placebo (1:1:1), for the prevention of POAF after cardiac surgery. Randomization was stratified by age (<65, ≥65 years) and type of surgery (nonvalvular/valve surgery). The primary endpoint was the occurrence of continuous AF ≥30 seconds. RESULTS: Among 312 modified intention-to-treat participants (placebo, n = 102; 125 U, n = 104; and 250 U, n = 106), the mean age was 66.9 ± 6.8 years; 17% were female; and 64% had coronary artery bypass graft (CABG) only, 12% had CABG + valve, and 24% had valve surgery. The primary endpoint occurred in 46.1% of the placebo group, 36.5% of the 125-U group (relative risk [RR] vs placebo: 0.80; 95% CI: 0.58-1.10; P = 0.16), and 47.2% of the 250-U group (RR vs placebo: 1.04; 95% CI: 0.79-1.37; P = 0.78). The primary endpoint was reduced in the 125-U group in those ≥65 years of age (RR: 0.64; 95% CI: 0.43-0.94; P = 0.02) with a greater reduction in CABG-only participants ≥65 years of age (RR: 0.49; 95% CI: 0.27-0.87; P = 0.01). Rehospitalization and rates of adverse events were similar across the 3 groups. CONCLUSIONS: There were no significant differences in the rate of POAF with either dose compared with placebo; however, there was a lower rate of POAF in participants ≥65 years undergoing CABG only and receiving 125 U of AGN-151607. These hypothesis-generating findings require investigation in a larger, adequately powered randomized clinical trial. (Botulinum Toxin Type A [AGN-151607] for the Prevention of Post-operative Atrial Fibrillation in Adult Participants Undergoing Open-chest Cardiac Surgery [NOVA]; NCT03779841); A Phase 2, Multi-Center, Randomized, Double-Blind, Placebo-Controlled, Dose Ranging Study to Evaluate the Efficacy and Safety of Botulinum Toxin Type A [AGN 151607] Injections into the Epicardial Fat Pads to Prevent Post-Operative Atrial Fibrillation in Patients Undergoing Open-Chest Cardiac Surgery; 2017-004399-68).


Assuntos
Fibrilação Atrial , Toxinas Botulínicas Tipo A , Complicações Pós-Operatórias , Humanos , Fibrilação Atrial/prevenção & controle , Feminino , Masculino , Idoso , Toxinas Botulínicas Tipo A/uso terapêutico , Toxinas Botulínicas Tipo A/administração & dosagem , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Método Duplo-Cego , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Resultado do Tratamento , Ponte de Artéria Coronária/efeitos adversos
14.
Artigo em Inglês | MEDLINE | ID: mdl-38609733

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

16.
Heart Rhythm O2 ; 5(2): 122-130, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38545323

RESUMO

Background: Cerebral microembolization and atrophy complicate atrial fibrillation (AF). Objectives: We aimed to compare changes in neuroimaging findings between AF patients treated with catheter ablation and those treated with medical therapy. Methods: In this pilot study, we evaluated differences in the change in regional white matter hyperintensity burden (WMHb) and cognitive function from baseline to 6 weeks and 1 year in patients treated with AF ablation (n = 12) and patients treated with medical management alone (n = 11). Change in cortical thickness over time in Alzheimer's disease (AD) risk, aging-associated, and shared AD risk/aging regions was also compared between groups. Results: The mean age was 69.7 ± 5.0 years, 78% of patients were male, 39% had persistent AF, and all received oral anticoagulation. There were no significant differences between groups in the change in cognitive function. At 6 weeks, there were no significant differences in periventricular WMHb changes between groups (0.00 vs 0.04, P = .12), but changes in attention/concentration were inversely correlated with periventricular (P = .01) and total (P = .03) WMHb. Medical management patients demonstrated significantly greater cortical thinning in AD risk regions from baseline to 1 year (P = .003). Conclusions: AF patients who underwent ablation demonstrated less cortical thinning in regions associated with AD risk than patients treated with medical therapy. Larger, prospective studies are needed to better understand the relationship between AF therapies and the development of cognitive decline.

17.
J Cardiovasc Electrophysiol ; 35(5): 950-964, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38477184

RESUMO

INTRODUCTION: Peak frequency (PF) mapping is a novel method that may identify critical portions of myocardial substrate supporting reentry. The aim of this study was to describe and evaluate PF mapping combined with omnipolar voltage mapping in the identification of critical isthmuses of left atrial (LA) atypical flutters. METHODS AND RESULTS: LA omnipolar voltage and PF maps were generated in flutter using the Advisor HD-Grid catheter (Abbott) and EnSite Precision Mapping System (Abbott) in 12 patients. Normal voltage was defined as ≥0.5 mV, low-voltage as 0.1-0.5 mV, and scar as <0.1 mV. PF distributions were compared with ANOVA and post hoc Tukey analyses. The 1 cm radius from arrhythmia termination was compared to global myocardium with unpaired t-testing. The mean age was 65.8 ± 9.7 years and 50% of patients were female. Overall, 34 312 points were analyzed. Atypical flutters most frequently involved the mitral isthmus (58%) or anterior wall (25%). Mean PF varied significantly by myocardial voltage: normal (335.5 ± 115.0 Hz), low (274.6 ± 144.0 Hz), and scar (71.6 ± 140.5 Hz) (p < .0001 for all pairwise comparisons). All termination sites resided in low-voltage regions containing intermediate or high PF. Overall, mean voltage in the 1 cm radius from termination was significantly lower than the remaining myocardium (0.58 vs. 0.95 mV, p < .0001) and PF was significantly higher (326.4 vs. 245.1 Hz, p < .0001). CONCLUSION: Low-voltage, high-PF areas may be critical targets during catheter ablation of atypical atrial flutter.


Assuntos
Potenciais de Ação , Flutter Atrial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Valor Preditivo dos Testes , Humanos , Flutter Atrial/fisiopatologia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Frequência Cardíaca
18.
Artigo em Inglês | MEDLINE | ID: mdl-38499825

RESUMO

BACKGROUND: Cardioneuroablation has been emerging as a potential treatment alternative in appropriately selected patients with cardioinhibitory vasovagal syncope (VVS) and functional AV block (AVB). However the majority of available evidence has been derived from retrospective cohort studies performed by experienced operators. METHODS: The Cardioneuroablation for the Management of Patients with Recurrent Vasovagal Syncope and Symptomatic Bradyarrhythmias (CNA-FWRD) Registry is a multicenter prospective registry with cross-over design evaluating acute and long-term outcomes of VVS and AVB patients treated by conservative therapy and CNA. RESULTS: The study is a prospective observational registry with cross-over design for analysis of outcomes between a control group (i.e., behavioral and medical therapy only) and intervention group (Cardioneuroablation). Primary and secondary outcomes will only be assessed after enrollment in the registry. The follow-up period will be 3 years after enrollment. CONCLUSIONS: There remains a lack of prospective multicentered data for long-term outcomes comparing conservative therapy to radiofrequency CNA procedures particularly for key outcomes including recurrence of syncope, AV block, durable impact of disruption of the autonomic nervous system, and long-term complications after CNA. The CNA-FWRD registry has the potential to help fill this information gap.

19.
Eur Heart J ; 45(14): 1241-1251, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38426911

RESUMO

BACKGROUND AND AIMS: Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. METHODS: All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine-Gray competing risk models. RESULTS: 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6-64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%-5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36-.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%-6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). CONCLUSIONS: Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.


Assuntos
Arritmias Cardíacas , Marca-Passo Artificial , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Resultado do Tratamento , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Sistema de Registros , Estimulação Cardíaca Artificial/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...