1.
Clin Res Hepatol Gastroenterol ; 48(7): 102387, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38810879

RESUMO

INTRODUCTION: Endoscopy is still the gold, standard for assessing disease activity in Crohn's disease (CD). Its invasiveness, poor acceptability, and cost limit its use in the era of tight control and treat-to-target management. Fecal calprotectin (FC) and intestinal ultrasound (IUS) are non-invasive alternatives to colonoscopy to assess disease activity. We aimed to evaluate the performance of IUS and FC to assess mucosal healing in CD. METHODS: All consecutive CD patients who underwent colonoscopy for mucosal healing assessment and IUS and/or FC within four weeks between September 2019 and April 2022 were included in a prospective cohort. The bowel-wall thickness (BWT) and color Doppler signal (CDS) were assessed for each segment. Endoscopic remission was defined by a CDEIS score < 3. RESULTS: In total, 153 patients were included, of whom 122 showed endoscopic mucosal healing. Eighty-two (53.6 %) were female, the median was age 36 years (IQR, 28-46), and the median disease duration was 10 years (IQR, 4-19). The sensitivity (Se), specificity (Sp), positive predictive value (PPV), and negative predictive value (NPV) of a BWT < 3 mm to predict endoscopic mucosal healing were 56 %, 88 %, 95 %, and 36 %, respectively (patients misclassified as mucosal healing, 2.5 %). The best FC threshold (< 92.9 µg/g) provided similar results: 77 %, 89 %, 96 %, and 67 %, respectively (patients misclassified, 2.2 %). The association of an FC < 250 µg/g with a BWT < 3 mm and the absence of CDS increased the Sp and PPV: Se 58 %, Sp 95 %, PPV 97 %, VPN 43 %; patients misclassified, 1.3 %. CONCLUSION: Noninvasive evaluation of mucosal healing by IUS or calprotectin efficiently identifies patients with CD who have achieved endoscopic mucosal healing.

2.
Acta Radiol ; 63(9): 1283-1292, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34365803

RESUMO

BACKGROUND: Patients with urolithiasis undergo radiation overexposure from computed tomography (CT) scans. Improvement of image reconstruction is necessary for radiation dose reduction. PURPOSE: To evaluate a deep learning-based reconstruction algorithm for CT (DLIR) in the detection of urolithiasis at low-dose non-enhanced abdominopelvic CT. MATERIAL AND METHODS: A total of 75 patients who underwent low-dose abdominopelvic CT for urolithiasis were retrospectively included. Each examination included three reconstructions: DLIR; filtered back projection (FBP); and hybrid iterative reconstruction (IR; ASiR-V 70%). Image quality was subjectively and objectively assessed using attenuation and noise measurements in order to calculate the signal-to-noise ratio (SNR), absolute contrast, and contrast-to-noise ratio (CNR). Attenuation of the largest stones were also compared. Detectability of urinary stones was assessed by two observers. RESULTS: Image noise was significantly reduced with DLIR: 7.2 versus 17 and 22 for ASiR-V 70% and FBP, respectively. Similarly, SNR and CNR were also higher compared to the standard reconstructions. When the structures had close attenuation values, contrast was lower with DLIR compared to ASiR-V. Attenuation of stones was also lowered in the DLIR series. Subjective image quality was significantly higher with DLIR. The detectability of all stones and stones >3 mm was excellent with DLIR for the two observers (intraclass correlation [ICC] = 0.93 vs. 0.96 and 0.95 vs. 0.99). For smaller stones (<3 mm), results were different (ICC = 0.77 vs. 0.86). CONCLUSION: For low-dose abdominopelvic CT, DLIR reconstruction exhibited image quality superior to ASiR-V and FBP as well as an excellent detection of urinary stones.


Assuntos
Aprendizado Profundo , Cálculos Urinários , Urolitíase , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Urolitíase/diagnóstico por imagem
5.
AJR Am J Roentgenol ; 215(4): 807-817, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32755352

RESUMO

OBJECTIVE. The objective of our study was to assess the accuracy and reproducibility of right ventricular volumes and function measurements in patients with repaired tetralogy of Fallot using two k-adaptive-t autocalibrating reconstruction for cartesian sampling (kat-ARC) accelerated sequences: a morphologic 3D cine sequence and a functional free-breathing 4D flow sequence. SUBJECTS AND METHODS. Seventeen patients who underwent cardiac MRI with gadolinium injection as part of follow-up of repaired tetralogy of Fallot from March 2017 to July 2018 were prospectively included in the initial study population; the final study cohort was composed of 15 of the 17 patients. Ventricle volume measurements were performed on a 3D cine kat-ARC sequence, a 4D flow kat-ARC sequence, and a 2D cine balanced steady-state free precession (bSSFP) sequence. The 2D cine bSSFP sequence was the reference standard in cardiac assessment. Intertechnique and interobserver analyses were performed. Bland-Altman analysis and correlation tests were used to compare quantitative measurements. RESULTS. Ventricular end-diastolic volume (EDV) and end-systolic volume (ESV) values were well correlated in the right ventricle (r = 0.94-0.98) for both 3D and 4D sequences. Ejection fraction (EF) also showed good correlation for both 3D and 4D sequences (r = 0.79 and r = 0.92). Bland-Altman analysis showed good agreement between right and left ventricular volumes, with narrower limits of agreement in the left ventricle, and an intraclass correlation coefficient (ICC) of greater than 0.80. For the 4D flow sequence, ventricular volumes were overestimated, which led to underestimation of the EF (bias for EDV = -10.2 mL, bias for ESV = -22.7 mL, bias for EF = 6.4%). Interobserver agreement was excellent for the ventricular volumes (ICC, 0.93-0.99) and fair to excellent for the EFs (ICC, 0.59-0.83). CONCLUSION. Compared with the reference standard 2D bSSFP sequence, the 3D cine kat-ARC accelerated sequence showed good accuracy and reproducibility for right ventricular measurements in patients with repaired tetralogy of Fallot. The short duration of the 4D flow kat-ARC sequence appears promising for performing volumetric measurements.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Volume Sistólico/fisiologia , Tetralogia de Fallot/diagnóstico por imagem , Função Ventricular Direita/fisiologia , Adolescente , Adulto , Idoso , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/cirurgia , Adulto Jovem
6.
AJR Am J Roentgenol ; 213(1): 115-122, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30995100

RESUMO

OBJECTIVE. The purpose of this study was to evaluate whether dual-energy CT follow-up of kidney transplant recipients performed with only two contrast-enhanced phases and reconstructed material maps has the same diagnostic efficiency as triphasic conventional CT in detection and characterization of atypical renal cysts and renal masses. MATERIALS AND METHODS. In a retrospective study, 175 renal transplant patients underwent dual-energy CT as part of their follow-up (monoenergetic unenhanced, late contrast-enhanced, and tubular contrast-enhanced dual-energy phases). An unenhanced virtual series and material separation maps were reconstructed. ROIs were marked on theses lesions, the bladder, and the psoas muscle. Material suppressed iodine was used to record attenuation measurements on the unenhanced and virtual unenhanced series in the tubular and late phases, and material concentration measurements were obtained on the iodine density images. The delivered doses for each series were registered. RESULTS. One hundred one renal lesions (spontaneous attenuation > 20 HU, size > 10 mm) were detected. An iodine concentration threshold greater than 1500 µg/mL was associated with excellent diagnostic performance (sensitivity, 100%; specificity, 92.55%; positive predictive value, 50%; negative predictive value, 100%) for detection of suspect lesions (enhancement > 20 HU). The two lesions with an iodine concentration greater than 5000 µg/mL corresponded to the only two histologically proven cancers. CONCLUSION. Iodine concentration maps obtained with dual-energy CT perform as well as enhanced images obtained at conventional CT in the detection and characterization of tissue and atypical cystic renal lesions in kidney transplant recipients. Use of this method could reduce radiation dose, especially by avoiding the unenhanced series.

SELEÇÃO DE REFERÊNCIAS