Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am Heart J ; 142(3): 476-81, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11526361

RESUMO

BACKGROUND: Port access has been described for mitral and bypass surgery. The purpose of this study was to review the clinical and echocardiographic outcomes of aortic valve replacement by use of port access. METHODS: Between 1996 and 1999, 153 port-access aortic valve replacements were performed at our institution. The mean age was 63 years (range 16-91 years); 58% were male. The New York Heart Association mean class was III; 18% were in class IV. Thirteen percent had diabetes, 42% hypertension, 7% prior transient ischemic episode or stroke, 7% lung disease, 3% renal failure, and 13% previous surgery. Echocardiograms were obtained after valve replacement in 125 patients (96 intraoperative transesophageal and 97 transthoracic echoes). RESULTS: Median length of stay was 8 days. There were no intraoperative deaths; 10 patients (6.5%) died in the postoperative period. Stroke occurred in 4 (2.6%), sepsis in 5 (3.3%), renal failure in 5 (3.3%), pneumonia in 3 (2%), and wound infection in 1 (0.7%). Tissue prosthesis was present in 83 and a mechanical prosthesis in 42. No or trace regurgitation was seen on 94 of 96 (98%) postbypass intraoperative echocardiograms and mild on 2. On follow-up echocardiograms, moderate regurgitation was seen in 4 of 97 (4.1%), mild-to-moderate in 2 (2.1%), mild in 18 (18.6%), and no or trace in 71 (73.2%). Of those who had aortic regurgitation on intraoperative or follow-up echocardiograms, it was paravalvular in 8. CONCLUSIONS: Minimally invasive aortic valve replacement with a port-access approach is feasible, even in high-risk patients. Small incisions, a low infection rate, and a short length of stay are attainable. However, the complications associated with traditional aortic valve replacement still occur. Echocardiography is valuable both for intraoperative monitoring and follow-up of this new procedure.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Ecocardiografia , Implante de Prótese de Valva Cardíaca/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Cateterismo , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Pneumonia/etiologia , Complicações Pós-Operatórias , Insuficiência Renal/etiologia , Sepse/etiologia , Esterno/cirurgia , Acidente Vascular Cerebral/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...