1.
J Cardiovasc Echogr ; 31(1): 1-5, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34221878

RESUMO

The prevalence of pericardial effusion and its clinical significance is not well understood in COVID-19 patients. We report two cases of COVID-19-related pericardial effusion complicated by intrapericardial clot formation. The final outcome was favorable, but intrapericardial clot remained mostly unchanged at 6-month follow-up. The treatment approach and the long-term consequences are still unclear. We propose a review of this particular cardiovascular complication in COVID-19 patients.

2.
Ann Intensive Care ; 8(1): 64, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29766322

RESUMO

BACKGROUND: Until now, the prognostic value of microcirculatory alterations in critically ill patients has been mainly evaluated in highly selected subgroups. Aim of this study is to monitor the microcirculation daily in mixed group of Intensive Care Unit (ICU)-patients and to establish the association between (the evolution of) microcirculatory alterations and outcome. METHODS: This is a prospective longitudinal observational single-centre study in adult patients admitted to a 12-bed ICU in an Italian teaching hospital. Sublingual microcirculation was evaluated daily, from admission to discharge/death, using Sidestream Dark Field imaging. Videos were analysed offline to assess flow and density variables. Laboratory and clinical data were recorded simultaneously. A priori, a Microvascular Flow Index (MFI) < 2.6 was defined as abnormal. A binary logistic regression analysis was performed to evaluate the association between microcirculatory variables and outcomes; a Kaplan-Meier survival curve was built. Outcomes were ICU and 90-day mortality. RESULTS: A total of 97 patients were included. An abnormal MFI was present on day 1 in 20.6%, and in 55.7% of cases during ICU admission. Patients with a baseline MFI < 2.6 had higher ICU, in-hospital and 90-day mortality (45 vs. 15.6%, p = 0.012; 55 vs. 28.6%, p = 0.035; 55 vs. 26%, p = 0.017, respectively). An independent association between baseline MFI < 2.6 and outcome was confirmed in a binary logistic analysis (odds ratio 4.594 [1.340-15.754], p = 0.015). A heart rate (HR) ≥ 90 bpm was an adjunctive predictor of mortality. However, a model with stepwise inclusion of mean arterial pressure < 65 mmHg, HR ≥ 90 bpm, lactate > 2 mmol/L and MFI < 2.6 did not detect significant differences in ICU mortality. In case an abnormal MFI was present on day 1, ICU mortality was significantly higher in comparison with patients with an abnormal MFI after day 1 (38 vs. 6%, p = 0.001), indicating a time-dependent significant difference in prognostic value. CONCLUSIONS: In a general ICU population, an abnormal microcirculation at baseline is an independent predictor for mortality. In this setting, additional routine daily microcirculatory monitoring did not reveal extra prognostic information. Further research is needed to integrate microcirculatory monitoring in a set of commonly available hemodynamic variables. Trial registration NCT 02649088, www.clinicaltrials.gov . Date of registration: 23 December 2015, retrospectively registered.

3.
J Clin Monit Comput ; 31(4): 669-676, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27586243

RESUMO

Analysis of the microcirculation is currently performed offline, is time consuming and operator dependent. The aim of this study was to assess the ability and efficiency of the automatic analysis software CytoCamTools 1.7.12 (CC) to measure microvascular parameters in comparison with Automated Vascular Analysis (AVA) software 3.2. 22 patients admitted to the cardiothoracic intensive care unit following cardiac surgery were prospectively enrolled. Sublingual microcirculatory videos were analysed using AVA and CC software. The total vessel density (TVD) for small vessels, perfused vessel density (PVD) and proportion of perfused vessels (PPV) were calculated. Blood flow was assessed using the microvascular flow index (MFI) for AVA software and the averaged perfused speed indicator (APSI) for the CC software. The duration of the analysis was also recorded. Eighty-four videos from 22 patients were analysed. The bias between TVD-CC and TVD-AVA was 2.20 mm/mm2 (95 % CI 1.37-3.03) with limits of agreement (LOA) of -4.39 (95 % CI -5.66 to -3.16) and 8.79 (95 % CI 7.50-10.01) mm/mm2. The percentage error (PE) for TVD was ±32.2 %. TVD was positively correlated between CC and AVA (r = 0.74, p < 0.001). The bias between PVD-CC and PVD-AVA was 6.54 mm/mm2 (95 % CI 5.60-7.48) with LOA of -4.25 (95 % CI -8.48 to -0.02) and 17.34 (95 % CI 13.11-21.57) mm/mm2. The PE for PVD was ±61.2 %. PVD was positively correlated between CC and AVA (r = 0.66, p < 0.001). The median PPV-AVA was significantly higher than the median PPV-CC [97.39 % (95.25, 100 %) vs. 81.65 % (61.97, 88.99), p < 0.0001]. MFI categories cannot estimate or predict APSI values (p = 0.45). The time required for the analysis was shorter with CC than with AVA system [2'42″ (2'12″, 3'31″) vs. 16'12″ (13'38″, 17'57″), p < 0.001]. TVD is comparable between the two softwares, although faster with CC software. The values for PVD and PPV are not interchangeable given the different approach to assess microcirculatory flow.


Assuntos
Processamento de Imagem Assistida por Computador , Microcirculação , Reconhecimento Automatizado de Padrão , Software , Automação , Velocidade do Fluxo Sanguíneo , Vasos Sanguíneos/diagnóstico por imagem , Cuidados Críticos , Humanos , Unidades de Terapia Intensiva , Microscopia de Vídeo , Variações Dependentes do Observador , Perfusão , Estudos Prospectivos , Reprodutibilidade dos Testes
4.
J Clin Monit Comput ; 31(5): 981-988, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27539312

RESUMO

We aimed to assess the impact of image quality on microcirculatory evaluation with sidestream dark-field (SDF) videomicroscopy in critically ill patients and explore factors associated with low video quality. This was a retrospective analysis of a single-centre prospective observational study. Videos of the sublingual microcirculation were recorded using SDF videomicroscopy in 100 adult patients within 12 h from admittance to the intensive care unit and every 24 h until discharge/death. Parameters of vessel density and perfusion were calculated offline for small vessels. For all videos, a quality score (-12 = unacceptable, 1 = suboptimal, 2 = optimal) was assigned for brightness, focus, content, stability, pressure and duration. Videos with a total score ≤8 were deemed as unacceptable. A total of 2455 videos (853 triplets) was analysed. Quality was acceptable in 56 % of videos. Lower quality was associated with worse microvascular density and perfusion. Unreliable triplets (≥1 unacceptable or missing video, 65 % of total) showed lower vessel density, worse perfusion and higher flow heterogeneity as compared to reliable triplets (p < 0.001). Quality was higher among triplets collected by an extensively-experienced investigator or in patients receiving sedation or mechanical ventilation. Perfused vessel density was higher in patients with Glasgow Coma Scale (GCS) ≤8 (18.9 ± 4.5 vs. 17.0 ± 3.9 mm/mm2 in those with GCS >8, p < 0.001) or requiring mechanical ventilation (18.0 ± 4.5 vs. 17.2 ± 3.8 mm/mm2 in not mechanically ventilated patients, p = 0.059). We concluded that SDF video quality depends on both the operator's experience and patient's cooperation. Low-quality videos may produce spurious data, leading to an overestimation of microvascular alterations.


Assuntos
Microcirculação , Microscopia de Vídeo/métodos , Soalho Bucal/irrigação sanguínea , Língua/irrigação sanguínea , Adulto , Idoso , Cuidados Críticos , Estado Terminal , Escala de Coma de Glasgow , Humanos , Unidades de Terapia Intensiva , Pessoa de Meia-Idade , Estudos Prospectivos , Respiração Artificial , Estudos Retrospectivos , Gravação em Vídeo , Adulto Jovem
5.
PLoS One ; 10(5): e0122655, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25932999

RESUMO

BACKGROUND: Free hemoglobin (fHb) may induce vasoconstriction by scavenging nitric oxide. It may increase in older blood units due to storage lesions. This study evaluated whether old red blood cell transfusion increases plasma fHb in sepsis and how the microvascular response may be affected. METHODS: This is a secondary analysis of a randomized study. Twenty adult septic patients received either fresh or old (<10 or >15 days storage, respectively) RBC transfusions. fHb was measured in RBC units and in the plasma before and 1 hour after transfusion. Simultaneously, the sublingual microcirculation was assessed with sidestream-dark field imaging. The perfused boundary region was calculated as an index of glycocalyx damage. Tissue oxygen saturation (StO2) and Hb index (THI) were measured with near-infrared spectroscopy and a vascular occlusion test was performed. RESULTS: Similar fHb levels were found in the supernatant of fresh and old RBC units. Despite this, plasma fHb increased in the old RBC group after transfusion (from 0.125 [0.098-0.219] mg/mL to 0.238 [0.163-0.369] mg/mL, p = 0.006). The sublingual microcirculation was unaltered in both groups, while THI increased. The change in plasma fHb was inversely correlated with the changes in total vessel density (r = -0.57 [95% confidence interval -0.82, -0.16], p = 0.008), De Backer score (r = -0.63 [95% confidence interval -0.84, -0.25], p = 0.003) and THI (r = -0.72 [95% confidence interval -0.88, -0.39], p = 0.0003). CONCLUSIONS: Old RBC transfusion was associated with an increase in plasma fHb in septic patients. Increasing plasma fHb levels were associated with decreased microvascular density. TRIAL REGISTRATION: ClinicalTrials.gov NCT01584999.


Assuntos
Transfusão de Sangue , Hemoglobinas/metabolismo , Microcirculação , Sepse/sangue , Sepse/terapia , Idoso , Feminino , Hemodinâmica , Humanos , Masculino , Microvasos/metabolismo , Pessoa de Meia-Idade , Troca Gasosa Pulmonar , Sepse/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...