Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Nutr Clin Pract ; 28(2): 226-31, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23232749

RESUMO

BACKGROUND: Pediatric home parenteral nutrition (PN) patients present a unique challenge with risks of catheter-associated bloodstream infections (CABSIs), sometimes requiring subsequent catheter removal. Recurrent infections can lead to line removal and potential loss of venous access in the future. OBJECTIVE: Demonstrate that weekly ethanol lock therapy decreases CABSIs in long-term home PN patients and decreases line removals due to infections. METHODS: Beginning August 2007, patients receiving PN with a history of multiple previous CABSIs were started on ethanol lock therapy. Seventy percent ethanol solution was instilled into the central venous catheter (CVC) for 2 hours weekly. Episodes of CABSIs and catheter removal due to infection were documented in patients prior to and after ethanol lock therapy. RESULTS: Fourteen patients were followed for an average of 690 days after ethanol lock therapy was initiated. These patients were found to average 9.8 CABSIs per 1000 catheter days prior to starting ethanol lock therapy and only 2.7 CABSIs per 1000 catheter days after ethanol lock therapy (P < .001). Prior to ethanol lock therapy, the group averaged 4.3 catheter removals per 1000 catheter days but only 1.0 catheter removal per 1000 catheter days after ethanol lock therapy. CONCLUSION: Our group of patients showed a 73% reduction in CABSIs and a 77% reduction in catheter removal due to infection after ethanol lock therapy. In our patient population, weekly ethanol lock therapy for 2 hours is an effective technique to reduce CABSIs and catheter removal in long-term home PN patients.


Assuntos
Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Etanol , Nutrição Parenteral/métodos , Adolescente , Adulto , Infecções Relacionadas a Cateter/epidemiologia , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Lactente , Masculino , Nutrição Parenteral/efeitos adversos , Prevalência , Adulto Jovem
2.
Pediatr Infect Dis J ; 32(3): 289-91, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23076381

RESUMO

Ethanol lock therapy has been implemented to prevent infections of central venous catheters as well as to treat infections. Fungal catheter-associated blood stream infections are historically more difficult to treat and have required removal of central venous catheters. We report the largest case series to date, successfully treating 5 of 7 fungal catheter-associated blood stream infections with ethanol lock therapy and systemic echinocandin administration.


Assuntos
Antifúngicos/uso terapêutico , Infecções Relacionadas a Cateter/tratamento farmacológico , Catéteres/microbiologia , Desinfetantes/administração & dosagem , Equinocandinas/uso terapêutico , Etanol/administração & dosagem , Fungemia/tratamento farmacológico , Infecções Relacionadas a Cateter/prevenção & controle , Criança , Pré-Escolar , Desinfecção/métodos , Fungemia/prevenção & controle , Fungos/efeitos dos fármacos , Fungos/isolamento & purificação , Humanos , Lactente , Resultado do Tratamento , Adulto Jovem
3.
Nutrients ; 4(11): 1566-74, 2012 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-23201834

RESUMO

Aluminum (Al) is a contaminant in all parenteral nutrition (PN) solution component products. Manufacturers currently label these products with the maximum Al content at the time of expiry. We recently published data to establish the actual measured concentration of Al in PN solution products prior to being compounded in the clinical setting [1]. The investigation assessed quantitative Al content of all available products used in the formulation of PN solutions. The objective of this study was to assess the Al exposure in neonatal patients using the least contaminated PN solutions and determine if it is possible to meet the FDA “safe limit” of less than 5 μg/kg/day of Al. The measured concentrations from our previous study were analyzed and the least contaminated products were identified. These concentrations were entered into our PN software and the least possible Al exposure was determined. A significant decrease (41%–44%) in the Al exposure in neonatal patients can be achieved using the least contaminated products, but the FDA “safe limit” of less than 5 μg/kg/day of Al was not met. However, minimizing the Al exposure may decrease the likelihood of developing Al toxicity from PN.


Assuntos
Alumínio/análise , Contaminação de Medicamentos , Recém-Nascido Prematuro , Recém-Nascido Pequeno para a Idade Gestacional , Soluções de Nutrição Parenteral/química , Alumínio/toxicidade , Peso Corporal , Humanos , Recém-Nascido , Concentração Máxima Permitida , Fatores de Risco
4.
J Pediatr Pharmacol Ther ; 16(2): 92-7, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22477831

RESUMO

OBJECTIVE: Aluminum is a contaminant in all parenteral nutrition solutions. Manufacturers currently label these products with the maximum aluminum content at the time of expiry, but there are no published data to establish the actual measured concentration of aluminum in parenteral nutrition solution products prior to being compounded in the clinical setting. This investigation assessed quantitative aluminum content of products commonly used in the formulation of parenteral nutrition solutions. The objective of this study is to determine the best products to be used when compounding parenteral nutrition solutions (i.e., those with the least amount of aluminum contamination). METHODS: All products available in the United States from all manufacturers used in the production of parenteral nutrition solutions were identified and collected. Three lots were collected for each identified product. Samples were quantitatively analyzed by Mayo Laboratories. These measured concentrations were then compared to the manufacturers' labeled concentration. RESULTS: Large lot-to-lot and manufacturer-to-manufacturer differences were noted for all products. Measured aluminum concentrations were less than manufacturer-labeled values for all products. CONCLUSIONS: The actual aluminum concentrations of all the parenteral nutrition solutions were significantly less than the aluminum content based on manufacturers' labels. These findings indicate that 1) the manufacturers should label their products with actual aluminum content at the time of product release rather than at the time of expiry, 2) that there are manufacturers whose products provide significantly less aluminum contamination than others, and 3) pharmacists can select products with the lowest amounts of aluminum contamination and reduce the aluminum exposure in their patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...