Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Int J Mol Sci ; 24(5)2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36901745

RESUMO

Osteoarthritis (OA) is a degenerative bone disease that involves the microenvironment and macroenvironment of joints. Progressive joint tissue degradation and loss of extracellular matrix elements, together with different grades of inflammation, are important hallmarks of OA disease. Therefore, the identification of specific biomarkers to distinguish the stages of disease becomes a primary necessity in clinical practice. To this aim, we investigated the role of miR203a-3p in OA progression starting from the evidence obtained by osteoblasts isolated from joint tissues of OA patients classified according to different Kellgren and Lawrence (KL) grading (KL ≤ 3 and KL > 3) and hMSCs treated with IL-1ß. Through qRT-PCR analysis, it was found that osteoblasts (OBs) derived from the KL ≤ 3 group expressed high levels of miR203a-3p and low levels of ILs compared with those of OBs derived from the KL > 3 group. The stimulation with IL-1ß improved the expression of miR203a-3p and the methylation of the IL-6 promoter gene, favoring an increase in relative protein expression. The gain and loss of function studies showed that the transfection with miR203a-3p inhibitor alone or in co-treatments with IL-1ß was able to induce the expression of CX-43 and SP-1 and to modulate the expression of TAZ, in OBs derived from OA patients with KL ≤ 3 compared with KL > 3. These events, confirmed also by qRT-PCR analysis, Western blot, and ELISA assay performed on hMSCs stimulated with IL-1ß, supported our hypothesis about the role of miR203a-3p in OA progression. The results suggested that during the early stage, miR203a-3p displayed a protective role reducing the inflammatory effects on CX-43, SP-1, and TAZ. During the OA progression the downregulation of miR203a-3p and consequently the upregulation of CX-43/SP-1 and TAZ expression improved the inflammatory response and the reorganization of the cytoskeleton. This role led to the subsequent stage of the disease, where the aberrant inflammatory and fibrotic responses determined the destruction of the joint.


Assuntos
MicroRNAs , Osteoartrite , Humanos , Condrócitos/metabolismo , Inflamação/metabolismo , Interleucina-1beta/metabolismo , MicroRNAs/genética , Osteoartrite/metabolismo , Regulação para Cima
2.
Int J Mol Sci ; 25(1)2023 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-38203453

RESUMO

There is increasing interest in using magnesium (Mg) alloy orthopedic devices because of their mechanical properties and bioresorption potential. Concerns related to their rapid degradation have been issued by developing biodegradable micro- and nanostructured coatings to enhance corrosion resistance and limit the release of hydrogen during degradation. This systematic review based on four databases (PubMed®, Embase, Web of Science™ and ScienceDirect®) aims to present state-of-the-art strategies, approaches and materials used to address the critical factors currently impeding the utilization of Mg alloy devices. Forty studies were selected according to PRISMA guidelines and specific PECO criteria. Risk of bias assessment was conducted using OHAT and SYRCLE tools for in vitro and in vivo studies, respectively. Despite limitations associated with identified bias, the review provides a comprehensive analysis of preclinical in vitro and in vivo studies focused on manufacturing and application of Mg alloys in orthopedics. This attests to the continuous evolution of research related to Mg alloy modifications (e.g., AZ91, LAE442 and WE43) and micro- and nanocoatings (e.g., MAO and MgF2), which are developed to improve the degradation rate required for long-term mechanical resistance to loading and excellent osseointegration with bone tissue, thereby promoting functional bone regeneration. Further research is required to deeply verify the safety and efficacy of Mg alloys.


Assuntos
Procedimentos Ortopédicos , Ortopedia , Magnésio/farmacologia , Osteogênese , Ligas/farmacologia
3.
J Clin Med ; 11(21)2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36362601

RESUMO

One of the greatest challenges of hip revision surgery is the need to restore extensive bone loss by creating a stable reconstruction with long-term durability. The present observational, investigator-initiated prospective study was carried out to evaluate the clinical and radiological results of the use of a commercial biomimetic collagen-hydroxyapatite composite biomaterial (RegenOss) applied in hip revision surgery. Thirty-three patients who underwent hip revision were included in this study, and 29 received up to 2 years of follow-up. The acetabulum was reconstructed using an uncemented hemispherical shell both with or without an iliac fixation stem. Functional recovery was assessed according to the Harris Hip Score (HHS) at the pre-hospitalisation check-up, and at 6-, 12-, and 24-month follow-ups. Radiological evaluation consisting of X-ray analyses (6, 12, and 24 month follow-ups) and CT scan exams (within 10 weeks post-surgery and at 12-month follow-up) were performed to evaluate the reduction in bone defect and new bone regeneration. All the patients reported a complete recovery and a considerable improvement in functional outcome assessed by the HHS, which was significantly higher at all the follow-ups than at pre-hospitalisation. Moreover, radiological assessments revealed good scaffold integration. Overall, collected data suggest that RegenOss is a valid and safe alternative to restoring acetabular bone loss in revision hip arthroplasty.

4.
Geriatr Orthop Surg Rehabil ; 13: 21514593221080341, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35360669

RESUMO

Introduction: Periprosthetic femoral fracture around hip arthroplasty are growing in the world, nevertheless management and treatment options for fractures "around the stem" are still debated due to lack of high-level studies. Materials and method: A 85-item survey were fill out by 40 Italian Orthopedic Surgeon member of SIOT (Società Italiana di Ortopedia e Traumatologia) and AIR (Associazione Italiana Riprotesizzazione) to assess their current opinion in the management of type B periprosthetic femoral fractures. Responses were summarized using proportions, and further stratified by practice type, case volume, surgeon age, and fellowship training. Results: Vancouver/UCS fracture classification showed a good interobserver agreement (k value = .76). ORIF were the treatment of choice for UCS type B1 fractures (100%), revision stem for B2 (85%) and B3 (100%). Locked plates were preferred to cable plate and cerclage without a plate for B1 fractures (50% vs 40% vs 10%); revision with modular stem was preferred to monoblock stem for B2 fractures (50% vs 35%) and B3 (75% vs 15%). Responders tended to postpone at 1-month weight-bearing in patients with B1 fractures. Regarding postoperative pharmacological treatment there was absolute lack of consensus. Discussion: The primary finding of our survey confirmed the preference of ORIF for B1 fractures and stem revision for B2 and B3 fractures. However, there is no definitive operative technique for all UCS B fractures. Surgeons tended to favor locked plating over cable plating, although only slightly. This general lack of consensus coincides with the inconclusive evidence that currently exists in the literature, which demonstrates both favorable and unfavorable outcomes for both techniques. Conclusions: The absence of complete homogeneity among participants showed the need for prospective randomized studies to set up stronger guidelines for classification, management, surgical treatment, rehabilitation, and pharmacological support of periprosthetic femoral fractures.

5.
Acta Biomed ; 92(S1): e2021043, 2021 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-33944848

RESUMO

BACKGROUND: The giant haemorrhagic bursitis of the hip joint is a rare clinical condition that requires evidence-based guidelines for adequate diagnosis and management. Usually, this pathology requires conservative treatment; however, when abnormal size or clinical symptoms of compression of the surrounding noble structures are reported, an accurate differential diagnosis is required, in order to exclude other malignant conditions that can be included into differential diagnosis, and a surgical approach should be considered. The purpose of this work is to provide an appropriate description of the diagnostic and therapeutic path, providing an accurate analysis of the possible differential diagnoses. METHODS: We report 2 cases of symptomatic haemorrhagic bursitis of the hip joint, confirmed by histological investigation. In both cases, the patients complained a peripheral nerve deficit of a single limb: one patient presented paresthesia of lateral femoral cutaneous nerve while the second peripheral edema due to compression of the proximal venous and lymphatic circulation. RESULTS: Both cases were successfully managed by complete surgical excision of the mass, with no  recurrence. There were no major complications, but in first case the nerve deficit was permanent. CONCLUSIONS: Giant hemorrhagic trochanteric bursitis is a rare condition, but it should be included in the differential diagnosis of soft tissue masses arising from the hip joint. Due to the rarity of this entity, a cautious exclusion process of all plausible differential diagnosis must be undertaken, in order to not miss the possibility of soft-tissue tumors, primarily malignant high-grade sarcomas.


Assuntos
Bursite , Sarcoma , Bursite/diagnóstico , Hemorragia/diagnóstico , Hemorragia/etiologia , Articulação do Quadril/diagnóstico por imagem , Humanos , Recidiva Local de Neoplasia , Sarcoma/diagnóstico
6.
Int J Mol Sci ; 22(5)2021 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-33671114

RESUMO

Osteoarthritis (OA) is a degenerative bone disease that involved micro and macro-environment of joints. To date, there are no radical curative treatments for OA and novel therapies are mandatory. Recent evidence suggests the role of miRNAs in OA progression. In our previous studies, we demonstrated the role of miR-31-5p and miR-33a families in different bone regeneration signaling. Here, we investigated the role of miR-31-5p and miR-33a-5p in OA progression. A different expression of miR-31-5p and miR-33a-5p into osteoblasts and chondrocytes isolated from joint tissues of OA patients classified in based on different Kellgren and Lawrence (KL) grading was highlighted; and through a bioinformatic approach the common miRNAs target Specificity proteins (Sp1) were identified. Sp1 regulates the expression of gap junction protein Connexin43 (Cx43), which in OA drives the modification of i) osteoblasts and chondrocytes genes expression, ii) joint inflammation cytokines releases and iii) cell functions. Concerning this, thanks to gain and loss of function studies, the possible role of Sp1 as a modulator of CX43 expression through miR-31-5p and miR-33a-5p action was also evaluated. Finally, we hypothesize that both miRNAs cooperate to modulate the expression of SP1 in osteoblasts and chondrocytes and interfering, consequently, with CX43 expression, and they might be further investigated as new possible biomarkers for OA.


Assuntos
Conexina 43/metabolismo , Regulação da Expressão Gênica , MicroRNAs/genética , Osteoartrite/patologia , Osteoblastos/patologia , Fator de Transcrição Sp1/metabolismo , Adulto , Idoso , Células Cultivadas , Conexina 43/genética , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/genética , Osteoartrite/metabolismo , Osteoblastos/metabolismo , Prognóstico , Transdução de Sinais , Fator de Transcrição Sp1/genética
7.
Orthop Traumatol Surg Res ; 107(1): 102643, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32684432

RESUMO

BACKGROUND: Hip revision surgery for fractured ceramic components may represent the worst-case wear scenario due to the high risks of recurrent dislocations, instability, and third body wear. The ideal bearing choice for the new prosthetic articulation is still subject of debate, while alumina matrix composite (AMC) articulations offer theoretical superior performances; the present work was designed to test the wear behaviour of ceramic on ceramic articulations (liner and head) in a worst-case scenario by adding ceramic third-body particles to the test lubricant with combined walking and subluxation cycles in a hip joint simulator. Therefore, we performed an in vitro study aiming to assess how does AMC articulation perform with 1) third-body particles added to the test environment and 2) under subluxation stresses. HYPOTHESIS: We hypothesised that AMC articulations offer superior performances in such worst conditions. MATERIALS AND METHODS: A hip simulator test was designed to analyse how AMC articulation performs with third-body particles added to the test environment and under subluxation stresses. Two different load patterns including level walking and subluxation of the ceramic liner were applied. The test fluid lubricant was contaminated by adding coarse ceramic particles during the first 2 million cycles and fine ceramic particles from 2 to 4 million cycles. Group 1 consisted of an alumina matrix composite articulation (liner and head); group 2 consisted of an alumina liner and an alumina matrix composite head. A control group consisting of an alumina ceramic liner articulated against an alumina matrix composite head was provided and only axially loaded. The liners of groups 1 and 2 were tested at an in vivo angle of 45° in the medial lateral plane (inclinationangle), which corresponds to an angle L=30° relative to the ISO standard fixated position used for in vitro testing. All mass measurements were performed using a high precision balance (Sartorius BP211D). During each examination, images on dedicated location of the bearing surfaces were taken using a digital microscope. RESULTS: Mean cumulative wear of 0.09mg per million cycles between 2 and 4 million cycles was detected in group 2, and this value was significantly lower (p=0.016) in comparison with the average value in group 1 (0.21mg per million cycle). This result can be explained in light of a possible transformation phase of zirconia in AMC liners, probably due to excessive stress during subluxation cycles. However, wear levels observed are close to the gravimetric measurement detection limit of the Sartorious Balance (about 0.1-0.2mg); therefore, wear can be considered negligible in all groups. CONCLUSION: Our results confirm that AMC couplings perform very well even in the worst-case wear scenario. Since AMC articulations revealed 25% lower cumulative wear respect to AMC on cross linked polyethylene in same simulator setup, AMC articulations should be considered the bearing of choice in revision surgery in light of the high risk of recurrent dislocations, instability, and third body wear. LEVEL OF EVIDENCE: III, prospective case-control study, in vitro.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Óxido de Alumínio , Estudos de Casos e Controles , Cerâmica , Humanos , Teste de Materiais , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese
8.
Int Orthop ; 42(5): 983-994, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29523955

RESUMO

INTRODUCTION: This study tried to ascertain (1) the accuracy of synovial fluid white blood cell count and polymorphonucleate percentage in the diagnosis of periprosthetic hip and knee infections, (2) which test yielded superior test performance, and (3) the influence on diagnostic accuracy of study characteristics such as patient number, study design, study level, anatomic site, and threshold value. METHODS: A systematic search was conducted including papers assessing more effective cutoffs for synovial fluid tests, having comparative design, evaluating an exclusive cohort of hip or knee prostheses, including a clear definition of infected cases, and reporting sufficient data for the calculation of true-positive, false-positive, false-negative, and true-negative. RESULTS: A total of 375 articles were collected and, given the inclusion criteria, ten manuscripts were included. These studies assessed 1155 hip prostheses (276 infected cases) and 1235 knee prostheses (401 infected cases). The specificity of synovial fluid white blood cell count was significantly increased by using the threshold value ≥ 3000 cell/µL (p = 0.006); the sensitivity of polymorphonucleate percentage was significantly higher in detecting knee infections (p = 0.034). DISCUSSION: Both tests had a high specificity and sensitivity in detecting periprosthetic joint infections, and no clear superiority of one over the other existed. Furthermore, cutoff and anatomic site significantly influenced synovial fluid white blood cell count and polymorphonucleate percentage, respectively. CONCLUSION: Synovial fluid analysis is adequate in differentiating patients with periprosthetic hip and knee infections. Our data confirms international guidelines suggesting the use of 3000 cell/µL as cutoff threshold for synovial fluid white blood cell count. Since an anatomic site effect has been demonstrated, the goal of future studies will be to identify different cutoffs for hip and knee prostheses.


Assuntos
Artrite Infecciosa/diagnóstico , Prótese de Quadril/efeitos adversos , Prótese do Joelho/efeitos adversos , Contagem de Leucócitos/métodos , Infecções Relacionadas à Prótese/diagnóstico , Biomarcadores/análise , Articulação do Quadril/patologia , Articulação do Quadril/cirurgia , Humanos , Articulação do Joelho/patologia , Articulação do Joelho/cirurgia , Masculino , Sensibilidade e Especificidade
9.
Clin Orthop Relat Res ; 476(1): 137-145, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29389758

RESUMO

BACKGROUND: Prosthetic joint infection (PJI) is among the most-severe complications of a total joint arthroplasty. Identification of the causal organism is of paramount importance for successful treatment, and sonication of implants may aid in this identification. Dithiothreitol (DTT) treatment has been proposed as an alternative to sonication to improve diagnosis, reduce costs, and improve reliability of the procedure, but its efficacy remains poorly characterized. QUESTIONS/PURPOSES: (1) Are DTT and sonication more sensitive and/or more specific than standard cultures of tissue samples for the diagnosis of PJI? (2) Which test (DTT or sonication) is more sensitive when the clinician does not suspect infection before surgery? (3) Which test (DTT or sonication) is more sensitive when the clinician suspects infection before surgery? METHODS: Two hundred thirty-two patients undergoing revision of a knee or hip arthroplasty were prospectively evaluated in this randomized study. Cultures were performed on five tissue samples from each patient and on fluid obtained by prosthesis treatment in patients randomly assigned to sonication (117 patients) or DTT (115 patients). The reference standard against which cultures (on tissue samples and on fluids from sonication or DTT) were compared was the Musculoskeletal Infection Society definition of PJI. RESULTS: Cultures on sonication and DTT fluids provided higher sensitivity (89% and 91%, respectively) than those on standard cultures of tissue samples (79%; p < 0.001). Among patients in whom infection was not suspected before surgery, the sensitivity of DTT was greater than that for sonication and cultures on tissue samples (100% versus 70% and 50%; p < 0.001). Among patients in whom infection was suspected before surgery, the sensitivity of DTT and sonication were not greater than that for standard cultures (89% and 94% versus 86%). CONCLUSIONS: In this randomized study, we found no difference in sensitivity between DTT and sonication for the detection of PJI, and both of those tests were more sensitive than standard tissue cultures. Thus, cultures of sonication or DTT fluid should be considered important additional tools to standard cultures for definition of PJI and should be considered together with other criteria, especially in settings where infection is not suspected before revision surgery.Level of Evidence Level I, diagnostic study.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Bactérias/isolamento & purificação , Técnicas Bacteriológicas , Ditiotreitol/administração & dosagem , Prótese de Quadril/efeitos adversos , Prótese do Joelho/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Sonicação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Artroplastia do Joelho/instrumentação , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Reprodutibilidade dos Testes , Adulto Jovem
10.
Acta Orthop ; 89(2): 211-216, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29451057

RESUMO

Background and purpose - The best treatment option for severe slipped capital femoral epiphysis (SCFE) is still controversial. We compared clinical and radiographic outcomes of modified Dunn procedure (D) and in situ fixation (S) in severe SCFE. Patients and methods - We retrospectively compared D and S, used for severe stable SCFE (posterior sloping angle (PSA) > 50°) in 29 patients (15 D; 14 S). Propensity analysis and inverse probability of treatment weights (IPTW) to adjust for baseline differences were performed. Patients were followed for 2-7 years. Results - Avascular necrosis (AVN) occurred in 3 patients out of 15, after D, causing conversion to total hip replacement (THR) in 2 cases. In S, 1 hip developed chondrolysis, requiring THR 3 years after surgery. 3 symptomatic femoroacetabular impingements (FAI) occurred after S, requiring corrective osteotomy in 1 hip, and osteochondroplasty in another case. The risk of early re-operation was similar between the groups. The slippage was corrected more accurately and reliably by D. The Nonarthritic Hip Score was similar between groups, after adjusting for preoperative and postoperative variables. Interpretation - Although D was superior to S in restoring the proximal femoral anatomy, without increasing the risk of early re-operation, some concern remains regarding the potential risk of AVN in group D.


Assuntos
Parafusos Ósseos , Procedimentos Ortopédicos/métodos , Complicações Pós-Operatórias/epidemiologia , Escorregamento das Epífises Proximais do Fêmur/cirurgia , Adolescente , Criança , Feminino , Humanos , Masculino , Procedimentos Ortopédicos/efeitos adversos , Procedimentos Ortopédicos/instrumentação , Complicações Pós-Operatórias/diagnóstico por imagem , Radiografia , Estudos Retrospectivos , Escorregamento das Epífises Proximais do Fêmur/diagnóstico por imagem , Resultado do Tratamento
11.
Biomed Res Int ; 2017: 8361071, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29270435

RESUMO

Sciatic nerve palsies are rare but potentially devastating complications, accounting for more than 90% of neurologic injuries following total hip replacement. A systematic literature screening was carried out searching papers evaluating an exclusive population of postarthroplasty sciatic nerve palsies to ascertain (1) the influence of limb lengthening itself on sciatic nerve palsy, (2) the most important risk factors, (3) the long-term prognosis, and (4) the outcomes of different treatments. Fourteen manuscripts were finally included. The wide prevalence of retrospective case series decreased the global methodological quality of the retrieved papers. A hazardous lengthening threshold cannot be surely identified. Developmental dysplasia of the hip and previous hip surgeries are the most frequently recognized risk factors. Rate of full nerve function restoration approximates two-thirds of the cases, independently of the extent of initial neural damage. Poor evidences are available about the best treatment strategy. Well-structured multicentric prospective comparative studies are needed to substantiate or contrast the finding of this review. Anyway, since the onset of palsies is probably due to a combination of individual factors, risk of nerve damage and potential for nerve recovery should be evaluated on an individual basis.


Assuntos
Artroplastia de Quadril/efeitos adversos , Alongamento Ósseo/efeitos adversos , Neuropatia Ciática/fisiopatologia , Extremidades/fisiopatologia , Extremidades/cirurgia , Feminino , Quadril/fisiopatologia , Quadril/cirurgia , Humanos , Masculino , Fatores de Risco , Neuropatia Ciática/etiologia
12.
New Microbiol ; 40(2): 130-134, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28255603

RESUMO

The aim of this prospective study was to evaluate the performance of the Polymerase Chain Reaction (PCR) tool Xpert MRSA/SA SSTI test (Cepheid, Sunnyvale, CA, USA) on periprosthetic samples from a cohort of patients with suspected prosthetic joint infection (PJI). Seventy adult patients were included in this prospective study. On the basis of the preoperative evaluation, 39 patients were clinically considered to have a PJI, whereas 31 were presumed to suffer from an aseptic mobilization of the implant. Xpert MRSA/SA SSTI identified 4 out of 4 MRSA, 7 out of 7 MSSA, and 14 out of 16 methicillin resistant CoNS. Among the 31 patients not having a PJI, the rapid PCR did not find any bacteria among those identifiable, thus demonstrating an excellent performance in terms of specificity. Statistical analysis of the analytical performance showed a high correlation (p<0.001) between the result of Xpert MRSA/SA SSTI and culture. Xpert MRSA/SA SSTI assay is a novel, yet well known, rapid and accurate method for the identification of different species of staphylococci. The test can be used with peri-operative samples thus dramatically improving the diagnostic sensitivity. In addition, thanks to the very short turnaround time the use of Xpert assay can modify the clinical management of patients suffering from PJI during the ongoing operative procedure.


Assuntos
Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Staphylococcus/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Coagulase/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade , Adulto Jovem
13.
J Arthroplasty ; 32(1): 207-213, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27449716

RESUMO

BACKGROUND: Inadequate acetabular bone stock is a major issue in total hip arthroplasty, and several treatment options are available. Stemmed cups have been used in this scenario with variable results. A novel modular polyaxial uncemented iliac screw cup (HERM-BS-Sansone cup-Citieffe s.r.l., Calderara di Reno, Bologna, Italy) has been recently introduced to overcome the drawbacks of stemmed cups. In this retrospective study, we report the results of this cup in patients with large acetabular bone defects at 2- to 7-year follow-up. METHODS: We evaluated a consecutive series of 121 hips (118 revisions and 3 complex primary arthroplasties) treated with this novel cup at a mean follow-up of 46 months. Kaplan-Meier survival analysis was performed with implant revision for any reason as a primary end point. Further survival analysis was performed excluding septic failures. Clinical outcome was assessed with the Harris Hip Score. RESULTS: There had been 7 reoperations: 1 for aseptic loosening, 5 for deep infection, and 1 for recurrent dislocation. In 5 cases, the cup was removed; estimated survival rate at 5-year follow-up with implant removal for any reason was 95.6% (95% confidence interval = 91-99), and 98.3% (95% CI = 96-100) excluding those failed for infection. Mean Harris Hip Score at latest follow-up was 77 points (range, 44-95; standard deviation = 11.9). CONCLUSION: The present findings show the short-term efficacy of the iliac screw cup with respect to implant survival. A longer follow-up and a larger number of patients are necessary to confirm the encouraging preliminary results.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Prótese de Quadril/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/estatística & dados numéricos , Parafusos Ósseos , Feminino , Seguimentos , Humanos , Luxações Articulares/cirurgia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Publicações , Radiografia , Reoperação , Estudos Retrospectivos , Análise de Sobrevida
14.
JBJS Case Connect ; 6(2): e50, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-29252682

RESUMO

CASES: Joint instability after slipped capital femoral epiphysis (SCFE) reorientation through the physis has been attributed to a combination of capsulotomy and chondrolabral rim damage. We report on 3 hips with severe SCFE with closed physes, in which anatomic correction with femoral neck osteotomy led to joint instability. All 3 had acetabular roof flattening; 1 showed slight additional acetabular retroversion but also increased femoral anteversion. CONCLUSION: We speculate that the slight roof flattening in all 3 cases and/or the high femoral anteversion in 1 case had contributed to joint instability. Femoral derotation osteotomy was performed in 1 and periacetabular osteotomy was performed in 2 for joint restabilization.

15.
Orthopedics ; 34(8): e328-33, 2011 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-21815571

RESUMO

We retrospectively evaluated the postoperative results of total hip arthroplasty (THA) in patients presenting with Crowe group IV dislocated hips. Overall, results were compared with regard to the type of osteotomy performed (Z or oblique) to define the correct indications for surgical technique and choice of prosthetic implant. Thirty-three subtrochanteric shortening and derotational osteotomies in primary THA were performed in 26 patients secondary to congenital hip dislocation. A Z osteotomy was performed in 14 cases and an oblique osteotomy in 19. The surgical approach was direct lateral, and surgery was aimed at restoring the anatomic hip center. Femoral and acetabular fixation was uncemented. The most used stem was the S-ROM (DePuy, Leeds, United Kingdom), and the couplings used were ceramic-ceramic (7 cases), ceramic-polyethylene (3 cases), metal-polyethylene (15 cases), and metal-metal (3 cases). Mean follow-up was 88±45 months. According to the Merle D'Aubigné score, the overall clinical results were good in 23 cases, satisfactory in 6, and fair in 4. Union of the osteotomy occurred in 97% of cases, and the mean time required for osteotomy union was 6±2 months without significant differences between Z and oblique osteotomies. At last follow-up, there was loosening of 1 cup and 1 stem, and revision was necessary. Twelve percent of patients experienced postoperative dislocation and 9% developed neuropraxia of the femoral nerve. The clinical and radiological results were similar in both groups, with a high rate of pain relief, an improvement in limb-length discrepancy, and reduced limping, leading to a smaller or no insole. Currently, the more complex Z osteotomy has been abandoned, because a modular stem prosthesis with metaphyseal sleeve allows the oblique osteotomy to be used with an easier and shorter surgical procedure.


Assuntos
Artroplastia de Quadril/métodos , Fêmur/cirurgia , Luxação Congênita de Quadril/cirurgia , Osteotomia/métodos , Anormalidades Múltiplas , Adulto , Idoso , Cimentação , Feminino , Luxação Congênita de Quadril/complicações , Luxação Congênita de Quadril/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Articulação do Quadril/cirurgia , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Desenho de Prótese , Radiografia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
16.
Open Orthop J ; 4: 193-200, 2010 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-20721319

RESUMO

BACKGROUND: two-stage revision is considered the best treatment approach for the eradication of chronic joint infection. We report the outcome of 41 consecutive patients with infected hip prostheses, treated between 2000 and 2005, with two-stage revision using an antibiotic-loaded cement spacer. METHODS: Patients underwent a treatment protocol which included clinical and radiographic evaluation, laboratory investigations, hip aspiration, 99mTc-MDP and 99mTc-leukocyte-labeled scintigraphy and intraoperative assessment. All patients were diagnosed with a late chronic infection and classified as B-host according to the Cierny-Mader classification system. 9 patients out of 41 (22%) required a second interim treatment period, with exchange of the spacer. The proportion of methicillin-resistant Staphylococcus was similar between the one-spacer group and two-spacer group (28% vs 33%), whereas the proportion of patients with three or more risk factors was significantly higher in the two-spacer group than in the one-spacer group (28% vs 55%, respectively). RESULTS: Forty patients had final reimplantation, one patient had a resection arthroplasty. At an average follow-up of 5.3 years no recurrence of infection occurred. The average post-operative Harris hip score improved from 41 to 80. CONCLUSIONS: In the treatment of two-stage revision arthroplasty the adherence to the protocol proved to be effective for infection eradication and final reimplantation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...