Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanophotonics ; 13(10): 1759-1764, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38681676

RESUMO

Heterodyne detection based on interband cascade lasers (ICL) has been demonstrated in a wide range of different applications. However, it is still often limited to bulky tabletop systems using individual components such as dual laser setups, beam shaping elements, and discrete detectors. In this work, a versatile integrated ICL platform is investigated for tackling this issue. A RF-optimized, two-section ICL approach is employed, consisting of a short section typically used for efficient modulation of the cavity field and a long gain section. Such a laser is operated in reversed mode, with the entire Fabry-Pérot waveguide utilized as a semiconductor optical amplifier (SOA) and the electrically separated short section as detector. Furthermore, a racetrack cavity is introduced as on-chip single-mode reference generator. The field of the racetrack cavity is coupled into the SOA waveguide via an 800 nm gap. By external injection of a single mode ICL operating at the appropriate wavelength, a heterodyne beating between the on-chip reference and the injected signal can be observed on the integrated detector section of the SOA-detector.

2.
Nature ; 625(7996): 685-690, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38267681

RESUMO

Optical frequency-comb sources, which emit perfectly periodic and coherent waveforms of light1, have recently rapidly progressed towards chip-scale integrated solutions. Among them, two classes are particularly significant-semiconductor Fabry-Perót lasers2-6 and passive ring Kerr microresonators7-9. Here we merge the two technologies in a ring semiconductor laser10,11 and demonstrate a paradigm for the formation of free-running solitons, called Nozaki-Bekki solitons. These dissipative waveforms emerge in a family of travelling localized dark pulses, known within the complex Ginzburg-Landau equation12-14. We show that Nozaki-Bekki solitons are structurally stable in a ring laser and form spontaneously with tuning of the laser bias, eliminating the need for an external optical pump. By combining conclusive experimental findings and a complementary elaborate theoretical model, we reveal the salient characteristics of these solitons and provide guidelines for their generation. Beyond the fundamental soliton circulating inside the ring laser, we demonstrate multisoliton states as well, verifying their localized nature and offering an insight into formation of soliton crystals15. Our results consolidate a monolithic electrically driven platform for direct soliton generation and open the door for a research field at the junction of laser multimode dynamics and Kerr parametric processes.

3.
Lab Chip ; 23(7): 1816-1824, 2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-36800171

RESUMO

Quality control of liquids is an important part of analytical chemistry. The gold standard for measuring residual water in organic solvents and pharmaceutical applications is Karl Fischer titration. It has a high sensitivity, selectivity and accuracy. The downsides are a time-consuming offline analysis, together with the need for toxic reagents producing waste, and it suffers from poor inter-laboratory reproducibility. In this work, we present a high-performance lab-on-a-chip sensor exploiting mid-IR spectroscopy for liquid sensing. It is operating at 6.1 µm wavelength and is suitable for robust and flexible real-time in situ analysis of the residual water concentration in isopropyl alcohol. This is demonstrated in two experiments. A custom-made 60 µL flow cell is employed to measure only minute amounts of analyte in an inline configuration. In a second approach, the whole sensor is immersed into the analyte to demonstrate sensitive and rapid in situ operation on the millisecond time scale. This is confirmed by the ability for time resolved single water-droplet monitoring, while they are mixed into the liquid sample. We obtain a limit of detection between 120 ppm and 150 ppm with a concentration coverage spanning three orders of magnitude from 1.2 × 10-2%vol to 25%vol for the flow cell and 1.5 × 10-2%vol to 19%vol in the in situ configuration, respectively.

4.
Nat Commun ; 13(1): 4753, 2022 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-35963870

RESUMO

Mid-infrared spectroscopy is a sensitive and selective technique for probing molecules in the gas or liquid phase. Investigating chemical reactions in bio-medical applications such as drug production is recently gaining particular interest. However, monitoring dynamic processes in liquids is commonly limited to bulky systems and thus requires time-consuming offline analytics. In this work, we show a next-generation, fully-integrated and robust chip-scale sensor for online measurements of molecule dynamics in a liquid solution. Our fingertip-sized device utilizes quantum cascade technology, combining the emitter, sensing section and detector on a single chip. This enables real-time measurements probing only microliter amounts of analyte in an in situ configuration. We demonstrate time-resolved device operation by analyzing temperature-induced conformational changes of the model protein bovine serum albumin in heavy water. Quantitative measurements reveal excellent performance characteristics in terms of sensor linearity, wide coverage of concentrations, extending from 0.075 mg ml-1 to 92 mg ml-1 and a 55-times higher absorbance than state-of-the-art bulky and offline reference systems.


Assuntos
Dispositivos Lab-On-A-Chip , Espectrofotometria Infravermelho , Temperatura
5.
ACS Appl Mater Interfaces ; 10(12): 10102-10114, 2018 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-29488376

RESUMO

After organic photovoltaic (OPV) cells achieved efficiency of more than 10%, the control of stability and degradation mechanisms of solar cells became a prominent task. The increase of device efficiency due to incorporation of a hole-transport layer (HTL) in bulk-heterojunction solar cells has been extensively reported. However, the most widely used HTL material, poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS), is frequently suspected to be the dominating source for device instability under environmental conditions. Thereby, effects like photooxidation and electrode corrosion are often reported to shorten device lifetime. However, often in environmental device studies, the source of degradation, whether being from the HTL, the active layer, or the metal cathode is rather difficult to distinguish because the external diffusion of oxygen and water affects all components. In this study, different HTLs, namely, those prepared from traditional PEDOT:PSS and also two types of molybdenum trioxide (MoO3) are exposed to different environments, such as oxygen, light, or humidity, prior to device finalization under inert conditions. This allows investigating any effects within the HTL and from reactions at its interface to the indium tin oxide electrode or the active layer. The surface and bulk chemistry of the exposed HTL has been monitored and discussed in context to the observed device physics, dynamic charge transport, and spatial performance homogeneity of the corresponding OPV device. The results show that merely humidity exposure of the HTL leads to decreased device performance for PEDOT:PSS, but also for one type of the tested MoO3. The losses are related to the amount of absorbed water in the HTL, inducing loss of active area in terms of interfacial contact. The device with PEDOT:PSS HTL after humid air exposure showed seriously decreased photocurrent by microdelamination of swelling/shrinkage of the hygroscopic layer. The colloidal MoO3 with water-based precursor solution presents slight decay of solar cell performance, also here caused by swelling/shrinking reaction, but by a combination of in-plane particle contact and resistance scaling with particle expansion. However, the device with quasi-continuous and alcohol-based MoO3 showed unharmed stable electrical performance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...