Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Obstet Gynecol ; 182(5): 1086-8, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10819835

RESUMO

Cervical incompetence has been acknowledged as a significant entity predisposing patients to second-trimester miscarriage. Various surgical techniques and approaches have been used in an attempt to prolong pregnancy and improve perinatal outcome. These include transvaginal and transabdominal cervical cerclage. Some patients require the placement of a transabdominal cervicoisthmic cerclage. Should the cerclage fail or the patient have preterm premature rupture of membranes, removal of the cerclage may be necessary. As a result the application of laparoscopy for the management of cervicoisthmic cerclage removal has been advocated in an effort to limit surgical complications. We report a case of laparoscopic removal of a transabdominally placed cervical cerclage in a 32-year-old woman at 16 weeks' gestation with preterm premature rupture of membranes and inevitable miscarriage. Laparoscopy appeared to be a safe and effective means of managing the removal of this transabdominally placed cervicoisthmic cerclage.


Assuntos
Laparoscopia , Incompetência do Colo do Útero/cirurgia , Abdome , Adulto , Feminino , Ruptura Prematura de Membranas Fetais , Idade Gestacional , Humanos , Laparotomia , Gravidez , Equipamentos Cirúrgicos
2.
Obstet Gynecol ; 94(5 Pt 2): 825-7, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10546744

RESUMO

BACKGROUND: Placenta accreta has been estimated to complicate approximately one in 2500 deliveries, resulting in significant morbidity and mortality. Conservative treatment of placenta accreta has been done in certain clinical situations when preservation of the uterus and further childbearing are desired. The Argon beam coagulator is an electrosurgical device used for hemostasis during various operations. We report its use in a case complicated by placenta accreta. CASE: A 33-year-old woman, gravida 2 para 1, with placenta accreta was treated with the Argon beam coagulator, and hemostasis was achieved in the lower uterine segment. CONCLUSION: In selected cases, the Argon beam coagulator can assist conservative treatment of placenta accreta.


Assuntos
Eletrocirurgia , Placenta Acreta/cirurgia , Adulto , Argônio , Feminino , Humanos , Gravidez
6.
Pediatr Ann ; 4(7): 11-21, 1975 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24847820
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...