Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Arch. cardiol. Méx ; 88(4): 277-286, oct.-dic. 2018. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1124149

RESUMO

Resumen Antecedentes: Los procedimientos coronarios invasivos conllevan la administración de contraste y la exposición a radiaciones ionizantes, comportando un incremento de la morbimortalidad. La angiografía coronaria rotacional (ACR) permite adquirir múltiples proyecciones con una inyección de contraste. Hasta la fecha, no hay metaanálisis específicos comparando la ACR y la angiografía coronaria convencional (ACC) en pacientes en los que se realizan procedimientos coronarios invasivos, tanto diagnósticos como diagnósticos y terapéuticos. El objetivo de este metaanálisis es evaluar el impacto de la ACR en la cantidad de contraste, y la radiación ionizante en procedimientos coronarios invasivos. Métodos: Se realizó una búsqueda en las bases de datos PubMed y Ovid para identificar estudios tanto diagnósticos como diagnósticos y terapéuticos que comparasen ACR y ACC. Los estudios fueron evaluados sobre la calidad y los sesgos, y fueron incluidos si contemplaban alguna de las siguientes variables de valoración: volumen de contraste, radiación ionizante medida como producto dosis-área, Kerma-aire o tiempo de fluoroscopia. Resultados: Dieciséis estudios, totalizando 2,327 pacientes, fueron incluidos en el análisis final (1,146 pacientes recibieron ACR y 1,181, ACC), objetivándose diferencias significativas en volumen de contraste (diferencia estándar de medias (intervalo de confianza al 95%) −1.887 (−2.472 a −1.302); p < 0.001), producto dosis-área (−0.726 (−1.034 a −0.418); p < 0.001), Kerma-aire (−0.842 (−1.104 a −0.581); p < 0.001) y tiempo de fluoroscopia (0.263 (−0.496 a −0.030); p = 0.027). Conclusiones: La ACR permite reducir el volumen de contraste y la radiación, evaluada como producto dosis-área, Kerma-aire y tiempo de fluoroscopia en pacientes a los que se les realizan procedimientos coronarios invasivos.


Abstract Background: Invasive coronary procedures involve the administration of iodinated contrast and the exposure to ionising radiations, increasing morbidity and mortality. The rotational coronary angiography (RCA) allows acquiring multiple projections with a unique injection of iodinated contrast. To date, there are no meta-analyses specifically comparing RCA and conventional coronary angiography (CCA) in patients undergoing invasive coronary procedures, whether diagnostic or diagnostic and therapeutic. The aim of this meta-analysis is to assess the impact of RCA on the amount of iodinated contrast and the exposure to ionising radiations during invasive coronary procedures. Methods: A search in PubMed and Ovid databases was conducted to identify studies, including diagnostic and diagnostic and therapeutic studies, comparing RCA and CCA. The manuscripts were evaluated on quality and biases, and were included if they analysed any of the following endpoints: volume of contrast and exposure to ionising radiations measured as dose-area product, and Kerma-air or fluoroscopy time. Results: Sixteen studies, with a total of 2,327 patients, were included in the final analysis (1,146 patients underwent RCA and 1,181 patients underwent CCA), with significant differences being detected in volume of contrast (standard difference in means (95% confidence interval) −1.887 (−2.472 to −1.302); P < .001), dose-area product (−0.726 (−1.034 to −0.418); P < .001), Kerma-air (−0.842 (−1.104 to −0.581); P < .001), and fluoroscopy time (0.263 (−0.496 to −0.030); P = .027). Conclusions: RCA reduces the volume of contrast and the exposure to radiation, evaluated as dose-area product, Kerma-air, and fluoroscopy time, in patients undergoing invasive coronary procedures.


Assuntos
Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia Coronária/métodos , Meios de Contraste/administração & dosagem , Radiação Ionizante , Fluoroscopia , Compostos de Iodo/administração & dosagem
2.
Nefrología (Madrid) ; 38(2): 169-178, mar.-abr. 2018. graf, tab
Artigo em Espanhol | IBECS | ID: ibc-171085

RESUMO

Introducción y objetivos: La angiografía coronaria rotacional (ACR) permite reducir la cantidad de contraste administrado y puede prevenir el desarrollo de nefropatía inducida por contraste (NIC) durante los procedimientos coronarios invasivos. El objetivo del estudio es evaluar el impacto de la ACR en la aparición de NIC (aumento de creatinina ≥0,5mg/dL o ≥25%) tras un síndrome coronario agudo. Métodos: De abril a septiembre de 2016 se seleccionaron prospectivamente pacientes con síndrome coronario agudo remitidos para coronariografía diagnóstica con posibilidad de angioplastia ad hoc, que fueron estudiados con ACR o angiografía coronaria convencional (ACC) según criterio del operador. Se compararon la NIC (variable de valoración primaria), variables analíticas, angiográficas y clínicas. Resultados: De 235 pacientes reclutados, 116 pacientes fueron estudiados con ACR y 119 pacientes con ACC. El grupo de ACR presentaba mayor edad (64,0±11,8 vs. 59,7±12,1 años; p=0,006), más mujeres (44,8 vs. 17,6%; p<0,001) y peor filtrado glomerular estimado (76±25 vs. 86±27 mL/min/1,73 m2; p=0,001), con menos angioplastias (p<0,001). Asimismo, el grupo de ACR recibió menos contraste (113±92 vs. 169±103 mL; p<0,001), diferencias que se mantuvieron en los procedimientos diagnósticos (54±24 vs. 85±56 mL; p<0,001) y diagnóstico-terapéuticos (174±64 vs. 205±98 mL; p=0,049). El grupo de ACR presentó menos NIC (4,3 vs. 22,7%; p<0,001): en el análisis de regresión se objetivó que continuaba relacionándose con menor desarrollo de NIC (riesgo relativo ajustado: 0,868; IC 95%: 0,794-0,949; p=0,002). No hubo diferencias en las variables clínicas. Conclusiones: La ACR se asoció con menor administración de contraste durante procedimientos coronarios invasivos tras un síndrome coronario agudo, lo que resultó en una menor aparición de NIC (AU)


Introduction and objectives: Rotational coronary angiography (RCA) requires less contrast to be administered and can prevent the onset of contrast-induced nephropathy (CIN) during invasive coronary procedures. The aim of the study is to evaluate the impact of RCA on CIN (increase in serum creatinine ≥0.5mg/dl or ≥25%) after an acute coronary syndrome. Methods: From April to September 2016, patients suffering acute coronary syndromes who underwent diagnostic coronary angiography, with the possibility of ad hoc coronary angioplasty, were prospectively enrolled. At the operator's discretion, patients underwent RCA or conventional coronary angiography (CCA). CIN (primary endpoint), as well as analytical, angiographic and clinical endpoints, were compared between groups. Results: Of the 235 patients enrolled, 116 patients received RCA and 119 patients received CCA. The RCA group was composed of older patients (64.0±11.8 years vs. 59.7±12.1 years; p=0.006), a higher proportion of women (44.8 vs. 17.6%; p<0.001), patients with a lower estimated glomerular filtration rate (76±25 vs. 86±27ml/min/1.73 m2; p=0.001), and patients who underwent fewer coronary angioplasties (p<0.001) compared with the CCA group. Furthermore, the RCA group, received less contrast (113±92 vs. 169±103ml; p<0.001), including in diagnostic procedures (54±24 vs. 85±56ml; p<0.001) and diagnostic-therapeutic procedures (174±64 vs. 205±98ml; p=0.049) compared with the CCA group. The RCA group presented less CIN (4.3 vs. 22.7%; p<0.001) compared to the CCA group, and this finding was maintained in the regression analysis (Adjusted relative risk: 0.868; 95% CI: 0.794-0.949; p=0.002). There were no differences in clinical endpoints between the groups. Conclusions: RCA was associated with lower administration of contrast during invasive coronary procedures in acute coronary syndrome patients, resulting in lower incidence of CIN, in comparison with CCA (AU)


Assuntos
Humanos , Masculino , Feminino , Nefropatias/complicações , Angiografia Coronária/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Angioplastia/métodos , Análise de Regressão , Estudos Prospectivos , Estudos de Coortes , 28599 , Tabagismo/complicações
3.
Arch Cardiol Mex ; 88(4): 277-286, 2018.
Artigo em Espanhol | MEDLINE | ID: mdl-28888725

RESUMO

BACKGROUND: Invasive coronary procedures involve the administration of iodinated contrast and the exposure to ionising radiations, increasing morbidity and mortality. The rotational coronary angiography (RCA) allows acquiring multiple projections with a unique injection of iodinated contrast. To date, there are no meta-analyses specifically comparing RCA and conventional coronary angiography (CCA) in patients undergoing invasive coronary procedures, whether diagnostic or diagnostic and therapeutic. The aim of this meta-analysis is to assess the impact of RCA on the amount of iodinated contrast and the exposure to ionising radiations during invasive coronary procedures. METHODS: A search in PubMed and Ovid databases was conducted to identify studies, including diagnostic and diagnostic and therapeutic studies, comparing RCA and CCA. The manuscripts were evaluated on quality and biases, and were included if they analysed any of the following endpoints: volume of contrast and exposure to ionising radiations measured as dose-area product, and Kerma-air or fluoroscopy time. RESULTS: Sixteen studies, with a total of 2,327 patients, were included in the final analysis (1,146 patients underwent RCA and 1,181 patients underwent CCA), with significant differences being detected in volume of contrast (standard difference in means [95% confidence interval] -1.887 [-2.472 to -1.302]; P<.001), dose-area product (-0.726 [-1.034 to -0.418]; P<.001), Kerma-air (-0.842 [-1.104 to -0.581]; P<.001), and fluoroscopy time (0.263 [-0.496 to -0.030]; P=.027). CONCLUSIONS: RCA reduces the volume of contrast and the exposure to radiation, evaluated as dose-area product, Kerma-air, and fluoroscopy time, in patients undergoing invasive coronary procedures.


Assuntos
Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Fluoroscopia , Humanos , Compostos de Iodo/administração & dosagem , Radiação Ionizante
4.
Nefrologia (Engl Ed) ; 38(2): 169-178, 2018.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28734584

RESUMO

INTRODUCTION AND OBJECTIVES: Rotational coronary angiography (RCA) requires less contrast to be administered and can prevent the onset of contrast-induced nephropathy (CIN) during invasive coronary procedures. The aim of the study is to evaluate the impact of RCA on CIN (increase in serum creatinine ≥0.5mg/dl or ≥25%) after an acute coronary syndrome. METHODS: From April to September 2016, patients suffering acute coronary syndromes who underwent diagnostic coronary angiography, with the possibility of ad hoc coronary angioplasty, were prospectively enrolled. At the operator's discretion, patients underwent RCA or conventional coronary angiography (CCA). CIN (primary endpoint), as well as analytical, angiographic and clinical endpoints, were compared between groups. RESULTS: Of the 235 patients enrolled, 116 patients received RCA and 119 patients received CCA. The RCA group was composed of older patients (64.0±11.8 years vs. 59.7±12.1 years; p=0.006), a higher proportion of women (44.8 vs. 17.6%; p<0.001), patients with a lower estimated glomerular filtration rate (76±25 vs. 86±27ml/min/1.73 m2; p=0.001), and patients who underwent fewer coronary angioplasties (p<0.001) compared with the CCA group. Furthermore, the RCA group, received less contrast (113±92 vs. 169±103ml; p<0.001), including in diagnostic procedures (54±24 vs. 85±56ml; p<0.001) and diagnostic-therapeutic procedures (174±64 vs. 205±98ml; p=0.049) compared with the CCA group. The RCA group presented less CIN (4.3 vs. 22.7%; p<0.001) compared to the CCA group, and this finding was maintained in the regression analysis (Adjusted relative risk: 0.868; 95% CI: 0.794-0.949; p=0.002). There were no differences in clinical endpoints between the groups. CONCLUSIONS: RCA was associated with lower administration of contrast during invasive coronary procedures in acute coronary syndrome patients, resulting in lower incidence of CIN, in comparison with CCA.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Meios de Contraste/efeitos adversos , Angiografia Coronária/métodos , Iopamidol/análogos & derivados , Nefropatias/induzido quimicamente , Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/terapia , Idoso , Fármacos Cardiovasculares/uso terapêutico , Comorbidade , Dislipidemias/epidemiologia , Feminino , Humanos , Hipertensão/epidemiologia , Incidência , Iopamidol/efeitos adversos , Nefropatias/epidemiologia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Estudos Prospectivos , Fumar/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...