Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(11)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38894123

RESUMO

The self-sensing technology of microactuators utilizes a smart material to concurrently actuate and sense in a closed-loop control system. This work aimed to develop a position feedback-control system of nickel electrothermal microactuators using a resistivity self-sensing technique. The system utilizes the change in heating/sensing elements' resistance, due to the Joule heat, as the control parameter. Using this technique, the heating/sensing elements would concurrently sense and actuate in a closed loop control making the structures of microactuators simple. From a series of experiments, the proposed self-sensing feedback control system was successfully demonstrated. The tip's displacement error was smaller than 3 µm out of the displacement span of 60 µm. In addition, the system was less sensitive to the abrupt temperature change in surroundings as it was able to displace the microactuator's tip back to the desired position within 5 s, which was much faster than a feed-forward control system.

2.
Obstet Gynecol Sci ; 65(4): 376-381, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35707972

RESUMO

This study aimed to compare the efficacies of conventional and non-conventional (modified hydrostatic microfluidic pumpless device, MHPD) systems on ovarian tissue culture and in vitro follicle growth using a mouse model. A total of 56 ovarian cortical tissues retrieved from seven wild-type mice were divided into three groups: 1) fresh control, 2) conventional culture system (control), and 3) non-conventional system with MHPD. Ovarian tissues were cultured for 96 hours and evaluated for follicle morphology, developmental stage, intact follicle density, and relative gene expression levels (proliferating cell nuclear antigen, insulin like growth factor 1, BAX, and Bcl-2). Our major data demonstrated that the mean percentage of primary follicle development was increased by the MHPD (P<0.05). In addition, this device could maintain and support follicle development better than the conventional culture systems. However, the overall outcomes were not significantly improved by our first-design prototype. Consequently, nextgeneration platforms should be developed as alternative medical tools for fertility preservation research.

3.
Front Vet Sci ; 9: 1048131, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36686171

RESUMO

The rectangular filtering microfluidic chip was invented using microfluidics device fabrication technology and can separate living microfilariae from blood samples without a syringe pump. The diagnostic results are highly effective. The device is based on the principle of separating millions of blood cells from microfilariae using a rectangular filter structure. It disperses fluid evenly into the flow-passage channel, and its rectangular filter structure is the key to success in reducing the pressure and separating blood cells from microfilariae effectively. The flow rate and blood cell concentration were optimized in our study. The chip is intended to be a point-of-care device that can reduce the use of superfluous instrumentation in the field. The technology is designed to be rapid, accurate, and easy-to-use for all users, especially those in remote areas.

4.
Clin Exp Reprod Med ; 48(2): 111-123, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34024082

RESUMO

OBJECTIVE: Using domestic cats as a biomedical research model for fertility preservation, the present study aimed to characterize the influences of ovarian tissue encapsulation in biodegradable hydrogel matrix (fibrinogen/thrombin) on resilience to cryopreservation, and static versus non-static culture systems following ovarian tissue encapsulation and cryopreservation on follicle quality. METHODS: In experiment I, ovarian tissues (n=21 animals; 567 ovarian fragments) were assigned to controls or hydrogel encapsulation with 5 or 10 mg/mL fibrinogen (5 or 10 FG). Following cryopreservation (slow freezing or vitrification), follicle viability, morphology, density, and key protein phosphorylation were assessed. In experiment II (based on the findings from experiment I), ovarian tissues (n=10 animals; 270 ovarian fragments) were encapsulated with 10 FG, cryopreserved, and in vitro cultured under static or non-static systems for 7 days followed by similar follicle quality assessments. RESULTS: In experiment I, the combination of 10 FG encapsulation/slow freezing led to greater post-thawed follicle quality than in the control group, as shown by follicle viability (66.9%±2.2% vs. 61.5%±3.1%), normal follicle morphology (62.2%±2.1% vs. 55.2%±3.5%), and the relative band intensity of vascular endothelial growth factor protein phosphorylation (0.58±0.06 vs. 0.42±0.09). Experiment II demonstrated that hydrogel encapsulation promoted follicle survival and maintenance of follicle development regardless of the culture system when compared to fresh controls. CONCLUSION: These results provide a better understanding of the role of hydrogel encapsulation and culture systems in ovarian tissue cryopreservation and follicle quality outcomes using an animal model, paving the way for optimized approaches to human fertility preservation.

5.
Micromachines (Basel) ; 10(12)2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31805714

RESUMO

Cellular heterogeneity is a major hindrance, leading to the misunderstanding of dynamic cell biology. However, single cell analysis (SCA) has been used as a practical means to overcome this drawback. Many contemporary methodologies are available for single cell analysis; among these, microfluidics is the most attractive and effective technology, due to its advantages of low-volume specimen consumption, label-free evaluation, and real-time monitoring, among others. In this paper, a conceptual application for microfluidic single cell analysis for veterinary research is presented. A microfluidic device is fabricated with an elastomer substrate, polydimethylsiloxane (PDMS), under standard soft lithography. The performance of the microdevice is high-throughput, sensitive, and user-friendly. A total of 53.1% of the triangular microwells were able to trap single canine cutaneous mast cell tumor (MCT) cells. Of these, 38.82% were single cell entrapments, while 14.34% were multiple cell entrapments. The ratio of single-to-multiple cell trapping was high, at 2.7:1. In addition, 80.5% of the trapped cells were viable, indicating that the system was non-lethal. OCT4A-immunofluorescence combined with the proposed system can assess OCT4A expression in trapped single cells more precisely than OCT4A-immunohistochemistry. Therefore, the results suggest that microfluidic single cell analysis could potentially reduce the impact of cellular heterogeneity.

6.
Micromachines (Basel) ; 10(11)2019 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-31726665

RESUMO

Inertial separation techniques in a microfluidic system have been widely employed in the field of medical diagnosis for a long time. Despite no requirement of external forces, it requires strong hydrodynamic forces that could potentially cause cell damage or loss during the separation process. This might lead to the wrong interpretation of laboratory results since the change of structures and functional characteristics of cells due to the hydrodynamic forces that occur are not taken into account. Therefore, it is important to investigate the cell viability and damage along with the separation efficacy of the device in the design process. In this study, two inertial separation techniques-spiral microchannel and contraction-expansion array (CEA)-were examined to evaluate cell viability, morphology and intracellular structures using a trypan blue assay (TB), Scanning Electron Microscopy (SEM) and Wright-Giemsa stain. We discovered that cell loss was not significantly found in a feeding system, i.e., syringe, needle and tube, but mostly occurred in the inertial separation devices while the change of cell morphology and intracellular structures were found in the feeding system and inertial separation devices. Furthermore, percentage of cell loss was not significant in both devices (7-10%). However, the change of cell morphology was considerably increased (30%) in spiral microchannel (shear stress dominated) rather than in CEA (12%). In contrast, the disruption of intracellular structures was increased (14%) in CEA (extensional and shear stress dominated equally) rather than spiral microchannel (2%). In these experiments, leukocytes of canine were used as samples because their sizes are varied in a range between 7-12 µm, and they are commonly used as a biomarker in many clinical and medical applications.

7.
J Biomater Appl ; 33(7): 997-1010, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30757966

RESUMO

Long-term clinical success of a titanium implant not only depends upon osseointegration between implant and bone surface but also on the response of host immune cells. Following implantation of biomaterials, an inflammatory response, including T lymphocyte response, is ostensibly initiated by implant-cell interaction. However, little is known about the responses of T lymphocytes to titanium dioxide nanotubes. The present study aimed to explore the effect of titanium dioxide nanotubes on T lymphocytes in vitro and its biological consequences. The results of the present study showed that titanium dioxide nanotubes with diameter of 30-105 nm were non-cytotoxic to T lymphocytes, and the 105 nm titanium dioxide nanotube surface specifically possessed an ability to activate T lymphocytes, thus increasing DNA synthesis and cell proliferation. In addition, the 105 nm titanium dioxide nanotubes significantly activated the expression of FGF-2 gene and protein in T lymphocytes although smaller nanotubes (i.e. those with diameters of approximately 30 and 70 nm) had little effect on this. The present study investigated the mechanism by which 105 nm nanotubes stimulated FGF-2 expression in T lymphocytes by blocking key MAPK pathways. The inhibitors of JNK1/2/3 and ERK1/2 significantly inhibited 105 nm titanium dioxide nanotubes-induced FGF-2 expression. Corresponding to the increased expression of FGF-2, only the supernatant from T lymphocytes cultured on 105 nm nanotubes stimulated human mesenchymal stem cell proliferation. FGF-2 blocking antibody partially reversed the increased proliferation of human mesenchymal stem cells, supporting the role of T lymphocyte-derived FGF-2 in enhanced human mesenchymal stem cell proliferation. This suggests a significant role of T lymphocyte-titanium dioxide nanotube interaction in the proliferation of human mesenchymal stem cells, which is pivotal to the formation of new bone following implant placement.


Assuntos
Materiais Biocompatíveis/farmacologia , Fator 2 de Crescimento de Fibroblastos/genética , Células-Tronco Mesenquimais/efeitos dos fármacos , Linfócitos T/efeitos dos fármacos , Titânio/farmacologia , Materiais Biocompatíveis/química , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Humanos , Sistema de Sinalização das MAP Quinases/efeitos dos fármacos , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Nanotubos/química , Nanotubos/ultraestrutura , Linfócitos T/citologia , Linfócitos T/metabolismo , Titânio/química , Regulação para Cima/efeitos dos fármacos
8.
Micromachines (Basel) ; 9(1)2017 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-30393286

RESUMO

Our laboratory has the fundamental responsibility to study cancer stem cells (CSC) in various models of human and animal neoplasms. However, the major impediments that spike our accomplishment are the lack of universal biomarkers and cellular heterogeneity. To cope with these restrictions, we have tried to apply the concept of single cell analysis, which has hitherto been recommended throughout the world as an imperative solution pack for resolving such dilemmas. Accordingly, our first step was to utilize a predesigned spiral microchannel fabricated by our laboratory to perform size-based single cell separation using mast cell tumor (MCT) cells as a model. However, the impact of hydrodynamic shear stresses (HSS) on mechanical cell injury and viability in a spiral microchannel has not been fully investigated so far. Intuitively, our computational fluid dynamics (CFD) simulation has strongly revealed the formations of fluid shear stress (FSS) and extensional fluid stress (EFS) in the sorting system. The panel of biomedical assays has also disclosed cell degeneration and necrosis in the model. Therefore, we have herein reported the combinatorically detrimental effect of FSS and EFS on the viability of MCT cells after sorting in our spiral microchannel, with discussion on the possibly pathogenic mechanisms of HSS-induced cell injury in the study model.

9.
Malar J ; 15(1): 358, 2016 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-27405995

RESUMO

The large number of deaths caused by malaria each year has increased interest in the development of effective malaria diagnoses. At the early-stage of infection, patients show non-specific symptoms or are asymptomatic, which makes it difficult for clinical diagnosis, especially in non-endemic areas. Alternative diagnostic methods that are timely and effective are required to identify infections, particularly in field settings. This article reviews conventional malaria diagnostic methods together with recently developed techniques for both malaria detection and infected erythrocyte separation. Although many alternative techniques have recently been proposed and studied, dielectrophoretic and magnetophoretic approaches are among the promising new techniques due to their high specificity for malaria parasite-infected red blood cells. The two approaches are discussed in detail, including their principles, types, applications and limitations. In addition, other recently developed techniques, such as cell deformability and morphology, are also overviewed in this article.


Assuntos
Testes Diagnósticos de Rotina/métodos , Eritrócitos/parasitologia , Malária/diagnóstico , Plasmodium/isolamento & purificação , Humanos
10.
J Mech Behav Biomed Mater ; 50: 77-81, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26116955

RESUMO

Nowadays, microneedles are attracting a lot of attention because microneedles can deliver drugs, vaccines and hormones into the body without pain unlike conventional hypodermic needles. Furthermore, microneedles are safe for self-injection and disposal. This work aims to develop novel microneedles made of a solution of polystyrene (PS) in toluene. The mechanical properties of the fabricated PS microneedles were characterized in failure strength test and skin penetration test. According to the experimental results, a PS microneedle could withstand a large force up to 1.0 N without fracturing. Owing to the superior mechanical strength, the PS microneedles could penetrate the skin without any deterioration making them a promising alternative for commercial applications.


Assuntos
Microtecnologia/instrumentação , Agulhas , Poliestirenos/química , Falha de Equipamento , Soluções , Tolueno/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...