Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Catheter Cardiovasc Interv ; 84(5): 720-6, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-24174291

RESUMO

OBJECTIVES: To compare strut coverage patterns between everolimus-eluting stent (EES) and first-generation drug-eluting stents (DES) at more than 12 months after successful implantation, using optical coherence tomography (OCT). BACKGROUND: No sufficient OCT data has been reported comparing late strut coverage patterns between EES and first-generation DES. The favorable late results after EES implantation could be related to lower rates of uncovered and malapposed struts. METHODS: A total of 66 DES (21 EES, 23 SES, and 22 PES) that were implanted at least 1 year in advance in 40 patients and met good late angiographic results were evaluated by OCT. The percentage of uncovered and malapposed struts, calculated as the ratio of uncovered or malapposed struts to total struts in all cross-sectional images per stent, was compared among the three groups. RESULTS: A total of 35,061 struts were analyzed: 11,967 from EES, 11,855 from SES, and 11m239 from PES. The average tissue coverage thickness of the struts per stent was greater in EES than in SES and PES (109 ± 40 µm vs. 72 ± 27 µm and 83 ± 26 µm, respectively; P = 0.001). The percentage of uncovered struts (1.9 ± 4.1% in EES vs. 11.6 ± 12.7% in SES, P = 0.01 and vs. 7.1 ± 5.2% in PES, P < 0.001) and malapposed struts (0.1 ± 0.3% in EES vs. 1.8 ± 3.5% in SES, P = 0.01 and vs. 3.5 ± 5.1% in PES, P = 0.02) was much lower in EES than in first-generation DES, with no significant differences between SES and PES. CONCLUSIONS: Late strut coverage patterns are not similar between EES and first-generation DES. EES showed a lower percentage of uncovered and malapposed struts.


Assuntos
Angioplastia Coronária com Balão/métodos , Estenose Coronária/terapia , Stents Farmacológicos , Falha de Prótese , Sirolimo/análogos & derivados , Tomografia de Coerência Óptica/métodos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Estudos de Coortes , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estudos Transversais , Análise de Falha de Equipamento , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem , Desenho de Prótese , Sensibilidade e Especificidade , Sirolimo/administração & dosagem , Fatores de Tempo
2.
Catheter Cardiovasc Interv ; 80(6): 964-71, 2012 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-22855437

RESUMO

BACKGROUND AND OBJECTIVES: The purpose of this study was to evaluate the usefulness of transesophageal echocardiography during the implantation of the CoreValve percutaneous aortic prosthesis and the influence of the learning curve in its indications. METHODS: From April 2008 to January 2010, 53 patients were treated for symptomatic severe aortic stenosis with a CoreValve percutaneous aortic prosthesis. Transesophageal echocardiography was performed during the procedure for two reasons: if a discrepancy between the measures of the aortic annulus arose before the implantation and to provide visualization if a complication occurred during the procedure. Patients were divided in to two groups based on the learning curve (group I:the first 25 patients, group II: all of the subsequent patients). RESULTS: Thirty-six transesophageal echocardiographies were performed on 28 patients (53%).In 15 cases the indication was to assist us in determining the proper sized prosthesis, and in the other 21 cases it was performed due to a complication during the procedure. The numbers of intraprocedure transesophageal echocardiographies were similar in both learning-curve groups, (64% in group I vs. 71% in group II, P = 0.56) but the proportion of the studies indicated by serious complications was significantly lower in the second period of the learning curve (67% in group I vs. 17% in group II, P < 0.05). CONCLUSIONS: In our experience, transesophageal echocardiography was very useful in more than one-half of the patients during the implantation of the CoreValve percutaneous aortic prosthesis. After overcoming the learning curve, its indication due to serious procedure-related complications decreased significantly.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/instrumentação , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Curva de Aprendizado , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Distribuição de Qui-Quadrado , Competência Clínica , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Índice de Gravidade de Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...