Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Phys Lett ; 117(14): 143504, 2020 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-33060860

RESUMO

Piezoelectric acoustic transducers consisting of a circular aluminum nitride and silicon nitride unimorph diaphragm and an encapsulated air-filled back cavity are reported. Analytical and finite element analysis models are used to design the transducer to achieve low minimum detectable pressure (MDP) within chosen size restrictions. A series of transducers with varying radii are fabricated using microelectromechanical systems (MEMS) techniques. Experimental results are reported for a transducer with a 175 µm radius on a 400 × 500 × 500 µm3 die exhibiting structural resonances at 552 kHz in air and 133 kHz in water. The low-frequency (10 Hz-50 kHz) sensitivity is 1.87 µV/Pa (-114.5 dB re 1 V/Pa) in both air and water. The sensor has an MDP of 43.7 mPa/ Hz (67 dB SPL) at 100 Hz and 10.9 mPa/ Hz (55 dB SPL) at 1 kHz. This work contributes a set of design rules for MEMS piezoelectric diaphragm transducers that focuses on decreasing the MDP of the sensor through size, material properties, and residual stress considerations.

2.
Cochlear Implants Int ; 18(5): 240-249, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28629258

RESUMO

OBJECTIVES: Because of limited spectral resolution, Mandarin-speaking cochlear implant (CI) users have difficulty perceiving fundamental frequency (F0) cues that are important to lexical tone recognition. To improve Mandarin tone recognition in CI users, we implemented and evaluated a novel real-time algorithm (C-tone) to enhance the amplitude contour, which is strongly correlated with the F0 contour. METHODS: The C-tone algorithm was implemented in clinical processors and evaluated in eight users of the Nurotron NSP-60 CI system. Subjects were given 2 weeks of experience with C-tone. Recognition of Chinese tones, monosyllables, and disyllables in quiet was measured with and without the C-tone algorithm. Subjective quality ratings were also obtained for C-tone. RESULTS: After 2 weeks of experience with C-tone, there were small but significant improvements in recognition of lexical tones, monosyllables, and disyllables (P < 0.05 in all cases). Among lexical tones, the largest improvements were observed for Tone 3 (falling-rising) and the smallest for Tone 4 (falling). Improvements with C-tone were greater for disyllables than for monosyllables. Subjective quality ratings showed no strong preference for or against C-tone, except for perception of own voice, where C-tone was preferred. DISCUSSION: The real-time C-tone algorithm provided small but significant improvements for speech performance in quiet with no change in sound quality. Pre-processing algorithms to reduce noise and better real-time F0 extraction would improve the benefits of C-tone in complex listening environments. CONCLUSIONS: Chinese CI users' speech recognition in quiet can be significantly improved by modifying the amplitude contour to better resemble the F0 contour.


Assuntos
Algoritmos , Implantes Cocleares , Surdez/psicologia , Discriminação da Altura Tonal , Percepção da Fala , Adulto , Povo Asiático/psicologia , China , Implante Coclear/instrumentação , Surdez/cirurgia , Feminino , Humanos , Idioma , Masculino , Pessoa de Meia-Idade
3.
Acta Otolaryngol ; 136(1): 68-77, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26382170

RESUMO

CONCLUSION: This study described objective and subjective evaluations of the Nurotron® Venus™ Cochlear Implant System and indicated that this system produced a satisfactory performance. OBJECTIVE: To observe the performance of the Nurotron® Venus™ cochlear implant (CI) system via electrophysiological and psychophysical evaluations. METHODS: A 26-electrode CI system was specially designed. The performance of MRI in animal and cadaveric head experiments, EABR in cats experiment, the correlation between ESRT and C level, and psychophysics evaluations in clinical trials were observed. RESULTS: In the animal and cadaveric head experiments, magnet dislocation could not be prevented in the 1.5 T MRI without removal of the internal magnet. The EABR was clearly elicited in cat experiment. In the clinical trial, the ESRT was strongly correlated with C level (p < 0.001). The human clinical trial involving 57 post-lingually deafened native Mandarin-speaking patients was performed. Residual hearing protection in the implanted ear at each audiometric frequency was observed in 27.5-46.3% patients post-operatively. A pitch ranking test revealed that place pitches were generally ordered from apical to basal electrodes. The recognitions of the perceptions of 301 disyllabic words, environment sounds, disyllabic words, and numerals were significantly better than the pre-operative performance and reached plateaus.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva/terapia , Adolescente , Adulto , Animais , Audiometria de Tons Puros , Cadáver , Gatos , Criança , Perda Auditiva/diagnóstico , Perda Auditiva/etiologia , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Adulto Jovem
4.
Hear Res ; 322: 188-99, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25281795

RESUMO

Although the cochlear implant has been widely acknowledged as the most successful neural prosthesis, only a fraction of hearing-impaired people who can potentially benefit from a cochlear implant have actually received one due to its limited awareness, accessibility, and affordability. To help overcome these limitations, a 26-electrode cochlear implant has been developed to receive China's Food and Drug Administration (CFDA) approval in 2011 and Conformité Européenne (CE) Marking in 2012. The present article describes design philosophy, system specification, and technical verification of the Nurotron device, which includes advanced digital signal processing and 4 current sources with multiple amplitude resolutions that not only are compatible with perceptual capability but also allow interleaved or simultaneous stimulation. The article also presents 3-year longitudinal evaluation data from 60 human subjects who have received the Nurotron device. The objective measures show that electrode impedance decreased within the first month of device use, but was stable until a slight increase at the end of two years. The subjective loudness measures show that electric stimulation threshold was stable while the maximal comfort level increased over the 3 years. Mandarin sentence recognition increased from the pre-surgical 0%-correct score to a plateau of about 80% correct with 6-month use of the device. Both indirect and direct comparisons indicate indistinguishable performance differences between the Nurotron system and other commercially available devices. The present 26-electrode cochlear implant has already helped to lower the price of cochlear implantation in China and will likely contribute to increased cochlear implant access and success in the rest of the world. This article is part of a Special Issue entitled .


Assuntos
Percepção Auditiva , Implante Coclear/instrumentação , Implantes Cocleares , Pessoas com Deficiência Auditiva/reabilitação , Estimulação Acústica , Acústica , Adolescente , Adulto , Audiometria da Fala , Vias Auditivas/fisiopatologia , Limiar Auditivo , Criança , China , Estimulação Elétrica , Feminino , Humanos , Percepção Sonora , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Pessoas com Deficiência Auditiva/psicologia , Desenho de Prótese , Recuperação de Função Fisiológica , Processamento de Sinais Assistido por Computador , Espectrografia do Som , Percepção da Fala , Adulto Jovem
5.
Ann Otol Rhinol Laryngol ; 121(5): 328-36, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22724279

RESUMO

OBJECTIVES: The main goal of this study was to investigate the effects of acoustic characteristics, including timbre and fundamental frequency (F0), on the musical pitch discrimination of cochlear implant users. METHODS: Eight postlingually deafened cochlear implant users were recruited, along with 8 control subjects with normal hearing. Pitch discrimination tests were carried out using test stimuli from 4 musical instruments plus synthetic complex stimuli. Three reference tones with different F0s were used. RESULTS: The mean difference limens were 1.8 to 10.7 semitones in the just-noticeable difference task and 2.1 to 13.6 semitones in the pitch-direction discrimination task for different timbre and F0 combinations. Three-way analysis of variance showed that the acoustic characteristics of the musical stimuli, such as timbre and F0, significantly influenced pitch discrimination performance. CONCLUSIONS: Acoustic characteristics determine the complexity of the electrical stimulation pattern, which directly affects performance in pitch discrimination. A place pattern with a clear and regular low-order harmonic structure is most important for good pitch discrimination. A clear F0-related temporal pattern is also useful when the F0 is low. Pitch perception performance will worsen when there is interference in the high-frequency channels.


Assuntos
Implantes Cocleares , Música , Pessoas com Deficiência Auditiva/reabilitação , Discriminação da Altura Tonal , Adulto , Estudos de Casos e Controles , Limiar Diferencial , Feminino , Testes Auditivos/métodos , Testes Auditivos/normas , Humanos , Masculino , Reprodutibilidade dos Testes , Acústica da Fala , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...