Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
3.
Arq Bras Endocrinol Metabol ; 50(3): 445-9, 2006 Jun.
Artigo em Português | MEDLINE | ID: mdl-16936984

RESUMO

The laboratory methods usually employed for the measurement of serum TSH present sensitivity and specificity levels, both analytical and clinical, are highly satisfactory. Additionally, the methodologies are quite robust, so that false-positive and false-negative results are rare and unexpected. In this paper we describe two individuals quoted as euthyroid clinically, with no reference to autoimmune diseases, and no reference to the use of exogenous TSH, that presented with normal to extremely high serum TSH levels, depending on the method employed for analysis. In the three tested methods, serial dilution showed that the real TSH levels were between 250 and 300 mUI/L. In both cases the increment in TSH levels were due to the presence of TSH-binding proteins, forming high molecular weight complexes ("macro TSH"), well characterized by gel filtration chromatography on Superdex S-200 column. In one of the patients the binding protein was characterized as being IgG by protein-G binding study. In the other case, protein-G binding as well as anti-IgM binding failed to characterize the protein. These two cases call attention to the importance of the clinical-laboratory correlation and suggest the need that the presence of "macro TSH" must be investigated in patients with unexpectedly high TSH values.


Assuntos
Autoanticorpos/sangue , Doença de Graves/sangue , Tireotropina/sangue , Soluções Tampão , Criança , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Doença de Graves/diagnóstico , Humanos , Concentração de Íons de Hidrogênio , Pessoa de Meia-Idade , Peso Molecular , Sensibilidade e Especificidade , Tireotropina/química
4.
Arq. bras. endocrinol. metab ; 50(3): 445-449, jun. 2006. graf
Artigo em Português | LILACS | ID: lil-433737

RESUMO

As metodologias empregadas para a medida de TSH sérico apresentam níveis de especificidade e sensibilidade, tanto diagnósticas como analíticas, bastante elevadas. Adicionalmente, são metodologias bastante robustas, de maneira que resultados falso-positivos ou falso-negativos são raros e inesperados. Descrevemos neste trabalho dois casos de indivíduos descritos como eutiróideos, sem antecedentes de doenças autoimunes e sem referência ao uso de TSH exógeno, que apresentavam níveis de TSH de normais a muito elevados, dependendo da metodologia empregada. Em três métodos testados para a medida de TSH a diluição seriada das amostras mostrou que os níveis reais situavam-se entre 250 e 300 mUI/L. Nos dois casos, o aumento de TSH foi ocasionado pela presença de proteínas ligadoras de TSH no soro, formando formas de alto peso molecular ("macro TSH"), demonstradas por cromatografia de gel filtração em coluna de Superdex S-200. Em uma das pacientes a proteína ligadora foi caracterizada como IgG através de cromatografia em proteína G sepharose, na outra, a ligação em proteína G e em coluna de sepharose acoplada a monoclonal anti-IgM não conseguiu caracterizar a proteína ligadora sérica. Estes casos salientam a importância da correlação clínico-laboratorial e sugerem a necessidade de se pesquisar a presença de macro TSH em pacientes com níveis de TSH anormalmente elevados.


Assuntos
Criança , Feminino , Humanos , Pessoa de Meia-Idade , Autoanticorpos/sangue , Doença de Graves/sangue , Tireotropina/sangue , Soluções Tampão , Reações Falso-Negativas , Reações Falso-Positivas , Doença de Graves/diagnóstico , Concentração de Íons de Hidrogênio , Peso Molecular , Sensibilidade e Especificidade , Tireotropina/química
5.
Forensic Sci Int ; 160(2-3): 157-67, 2006 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-16243467

RESUMO

We report here a review of the seventh mitochondrial DNA (mtDNA) exercise undertaken by the Spanish and Portuguese working group (GEP) of the International Society for Forensic Genetics (ISFG) corresponding to the period 2003-2004. Five reference bloodstains from five donors (M1-M5), a mixed stain of saliva and semen (M6), and a hair sample (M7) were submitted to each participating laboratory for nuclear DNA (nDNA; autosomal STR and Y-STR) and mtDNA analysis. Laboratories were asked to investigate the contributors of samples M6 and M7 among the reference donors (M1-M5). A total of 34 laboratories reported total or partial mtDNA sequence data from both, the reference bloodstains (M1-M5) and the hair sample (M7) concluding a match between mtDNA profiles of M5 and M7. Autosomal STR and Y-STR profiling was the preferred strategy to investigate the contributors of the semen/saliva mixture (M6). Nuclear DNA profiles were consistent with a mixture of saliva from the donor (female) of M4 and semen from donor M5, being the semen (XY) profile the dominant component of the mixture. Strikingly, and in contradiction to the nuclear DNA analysis, mtDNA sequencing results yield a more simple result: only the saliva contribution (M4) was detected, either after preferential lysis or after complete DNA digestion. Some labs provided with several explanations for this finding and carried out additional experiments to explain this apparent contradictory result. The results pointed to the existence of different relative amounts of nuclear and mtDNAs in saliva and semen. We conclude that this circumstance could strongly influence the interpretation of the mtDNA evidence in unbalanced mixtures and in consequence lead to false exclusions. During the GEP-ISFG annual conference a validation study was planned to progress in the interpretation of mtDNA from different mixtures.


Assuntos
Técnicas de Laboratório Clínico/normas , DNA Mitocondrial/genética , Saliva/química , Sêmen/química , Impressões Digitais de DNA/normas , DNA Mitocondrial/sangue , Feminino , Cabelo/química , Humanos , Masculino , Controle de Qualidade , Análise de Sequência de DNA , Sociedades Médicas
6.
J. bras. patol ; 35(3): 133-5, jul.-set. 1999. tab
Artigo em Português | LILACS | ID: lil-247177

RESUMO

Os auto-anticorpos descritos na doença de Graves säo imunoglobulinas pertencentes à classe IgG que dirigem-se especificamente a certos antígenos tiroidianos, destacando-se entre eles: tireoglobulina (antitireoglobulina), peroxidade tiroidiana (antimicrossomia/antiperoxidade) e receptor do hormônio tireotrófico (TRab). Com o objetivo de avaliar a prevalência dos auto-anticorpos na doença de Graves descompensada, estudamos 46 pacientes virgens de tratamento. Concordante com os dados da literatura, o anticorpo anti-receptor de TSH mostrou-se o melhor marcador da doença de Graves, com 92,4 por cento de positividade


Assuntos
Humanos , Masculino , Feminino , Anticorpos/análise , Doença de Graves/imunologia , Receptores da Tireotropina/imunologia , Antitireóideos/uso terapêutico , Doenças Autoimunes/imunologia , Doença de Graves/sangue , Valor Preditivo dos Testes , Tri-Iodotironina/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...