Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Oncol ; 1: 18, 2006 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-16790059

RESUMO

BACKGROUND: To investigate the potential of parotic gland sparing of intensity modulated radiotherapy (3D-c-IMRT) performed with metallic compensators for head and neck cancer in a clinical series by analysis of dose distributions and clinical measures. MATERIALS AND METHODS: 39 patients with squamous cell cancer of the head and neck irradiated using 3D-c-IMRT were evaluable for dose distribution within PTVs and at one parotid gland and 38 patients for toxicity analysis. 10 patients were treated primarily, 29 postoperatively, 19 received concomitant cis-platin based chemotherapy, 20 3D-c-IMRT alone. Initially the dose distribution was calculated with Helax and photon fluence was modulated using metallic compensators made of tin-granulate (n = 22). Later the dose distribution was calculated with KonRad and fluence was modified by MCP 96 alloy compensators (n = 17). Gross tumor/tumor bed (PTV 1) was irradiated up to 60-70 Gy, [5 fractions/week, single fraction dose: 2.0-2.2 (simultaneously integrated boost)], adjuvantly irradiated bilateral cervical lymph nodes (PTV 2) with 48-54 Gy [single dose: 1.5-1.8]). Toxicity was scored according the RTOG scale and patient-reported xerostomia questionnaire (XQ). RESULTS: Mean of the median doses at the parotid glands to be spared was 25.9 (16.3-46.8) Gy, for tin granulate 26 Gy, for MCP alloy 24.2 Gy. Tin-granulate compensators resulted in a median parotid dose above 26 Gy in 10/22, MCP 96 alloy in 0/17 patients. Following acute toxicities were seen (degree 0-2/3): xerostomia: 87%/13%, dysphagia: 84%/16%, mucositis: 89%/11%, dermatitis: 100%/0%. No grade 4 reaction was encountered. During therapy the XQ forms showed (degree 0-2/3): 88%/12%. 6 months postRT chronic xerostomia degree 0-2/3 was observed in 85%/15% of patients, none with degree 4 xerostomia. CONCLUSION: 3D-c-IMRT using metallic compensators along with inverse calculation algorithm achieves sufficient parotid gland sparing in virtually all advanced head and neck cancers. Since the concept of lower single (and total) doses in the adjuvantly treated volumes reduces acute morbidity 3D-c-IMRT nicely meets demands of concurrent chemotherapy protocols.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Imageamento Tridimensional/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos , Adulto , Idoso , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glândula Parótida/patologia , Glândula Parótida/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Resultado do Tratamento , Xerostomia/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...