Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Int Conf Rehabil Robot ; 2023: 1-6, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37941171

RESUMO

Powered lower limb exoskeletons have been used in recent decades to support and improve conventional gait rehabilitation programs. In this context, visual feedback is considered a valuable tool to facilitate patient learning and engagement. Treadmill-based lower limb robotic exoskeletons are commonly incorporated with traditional screens or virtual reality (VR) devices. However, these modalities are incompatible with over-ground robotic exoskeletons, in which users should pay attention to multiple elements of the open environment and more complex tasks. Recent advances in augmented reality (AR) technology have unlocked a new way of displaying 3D graphics in untethered wearable devices like Microsoft's Hololens 2 without occluding the rest of the user's field of view. These advances can be crucial in certain situations and position AR as an excellent candidate to improve visual feedback when using robotic exoskeletons. In this work, we present the development of an AR-based audio-visual feedback system that tracks the trunk rotation from an Inertial Measurement Unit (IMU) to aid in walking tasks assisted by a lower limb robotic exoskeleton. A preliminary study was done integrating the H3 robotic exoskeleton with Hololens 2. We observed that displaying posture information is feasible and could help mitigate the unnatural posture often imposed by a robotic exoskeleton.


Assuntos
Realidade Aumentada , Exoesqueleto Energizado , Humanos , Estudos de Viabilidade , Retroalimentação , Caminhada , Marcha
2.
J Neuroeng Rehabil ; 20(1): 68, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-37259115

RESUMO

Exoskeletons are becoming the reference technology for assistance and augmentation of human motor functions in a wide range of application domains. Unfortunately, the exponential growth of this sector has not been accompanied by a rigorous risk assessment (RA) process, which is necessary to identify the major aspects concerning the safety and impact of this new technology on humans. This situation may seriously hamper the market uptake of new products. This paper presents the results of a survey that was circulated to understand how hazards are considered by exoskeleton users, from research and industry perspectives. Our analysis aimed to identify the perceived occurrence and the impact of a sample of generic hazards, as well as to collect suggestions and general opinions from the respondents that can serve as a reference for more targeted RA. Our results identified a list of relevant hazards for exoskeletons. Among them, misalignments and unintended device motion were perceived as key aspects for exoskeletons' safety. This survey aims to represent a first attempt in recording overall feedback from the community and contribute to future RAs and the identification of better mitigation strategies in the field.


Assuntos
Exoesqueleto Energizado , Traumatismos da Medula Espinal , Humanos , Inquéritos e Questionários
3.
Bioinspir Biomim ; 18(3)2023 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-37068491

RESUMO

Evaluating human-exoskeleton interaction typically requires experiments with human subjects, which raises safety issues and entails time-consuming testing procedures. This paper presents a mechatronic replica of a human leg, which was designed to quantify physical interaction dynamics between exoskeletons and human limbs without the need for human testing. In the first part of this work, we present the mechanical, electronic, sensory system and software solutions integrated in our leg replica prototype. In the second part, we used the leg replica to test its interaction with two types of commercially available wearable devices, i.e. an active full leg exoskeleton and a passive knee orthosis. We ran basic test examples to demonstrate the functioning and benchmarking potential of the leg replica to assess the effects of joint misalignments on force transmission. The integrated force sensors embedded in the leg replica detected higher interaction forces in the misaligned scenario in comparison to the aligned one, in both active and passive modalities. The small standard deviation of force measurements across cycles demonstrates the potential of the leg replica as a standard test method for reproducible studies of human-exoskeleton physical interaction.


Assuntos
Exoesqueleto Energizado , Humanos , Perna (Membro) , Benchmarking , Software , Fenômenos Biomecânicos
4.
Sensors (Basel) ; 23(2)2023 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-36679587

RESUMO

Nowadays, robotic technology for gait training is becoming a common tool in rehabilitation hospitals. However, its effectiveness is still controversial. Traditional control strategies do not adequately integrate human intention and interaction and little is known regarding the impact of exoskeleton control strategies on muscle coordination, physical effort, and user acceptance. In this article, we benchmarked three types of exoskeleton control strategies in a sample of seven healthy volunteers: trajectory assistance (TC), compliant assistance (AC), and compliant assistance with EMG-Onset stepping control (OC), which allows the user to decide when to take a step during the walking cycle. This exploratory study was conducted within the EUROBENCH project facility. Experimental procedures and data analysis were conducted following EUROBENCH's protocols. Specifically, exoskeleton kinematics, muscle activation, heart and breathing rates, skin conductance, as well as user-perceived effort were analyzed. Our results show that the OC controller showed robust performance in detecting stepping intention even using a corrupt EMG acquisition channel. The AC and OC controllers resulted in similar kinematic alterations compared to the TC controller. Muscle synergies remained similar to the synergies found in the literature, although some changes in muscle contribution were found, as well as an overall increase in agonist-antagonist co-contraction. The OC condition led to the decreased mean duration of activation of synergies. These differences were not reflected in the overall physiological impact of walking or subjective perception. We conclude that, although the AC and OC walking conditions allowed the users to modulate their walking pattern, the application of these two controllers did not translate into significant changes in the overall physiological cost of walking nor the perceived experience of use. Nonetheless, results suggest that both AC and OC controllers are potentially interesting approaches that can be explored as gait rehabilitation tools. Furthermore, the INTENTION project is, to our knowledge, the first study to benchmark the effects on human-exoskeleton interaction of three different exoskeleton controllers, including a new EMG-based controller designed by us and never tested in previous studies, which has made it possible to provide valuable third-party feedback on the use of the EUROBENCH facility and testbed, enriching the apprenticeship of the project consortium and contributing to the scientific community.


Assuntos
Exoesqueleto Energizado , Humanos , Benchmarking , Músculo Esquelético/fisiologia , Eletromiografia/métodos , Caminhada/fisiologia , Marcha/fisiologia , Fenômenos Biomecânicos/fisiologia
5.
Bioinspir Biomim ; 17(6)2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-36113448

RESUMO

Legged robotic technologies have moved out of the lab to operate in real environments, characterized by a wide variety of unpredictable irregularities and disturbances, all this in close proximity with humans. Demonstrating the ability of current robots to move robustly and reliably in these conditions is becoming essential to prove their safe operation. Here, we report an in-depth literature review aimed at verifying the existence of common or agreed protocols and metrics to test the performance of legged system in realistic environments. We primarily focused on three types of robotic technologies, i.e., hexapods, quadrupeds and bipeds. We also included a comprehensive overview on human locomotion studies, being it often considered the gold standard for performance, and one of the most important sources of bioinspiration for legged machines. We discovered that very few papers have rigorously studied robotic locomotion under irregular terrain conditions. On the contrary, numerous studies have addressed this problem on human gait, being nonetheless of highly heterogeneous nature in terms of experimental design. This lack of agreed methodology makes it challenging for the community to properly assess, compare and predict the performance of existing legged systems in real environments. On the one hand, this work provides a library of methods, metrics and experimental protocols, with a critical analysis on the limitations of the current approaches and future promising directions. On the other hand, it demonstrates the existence of an important lack of benchmarks in the literature, and the possibility of bridging different disciplines, e.g., the human and robotic, towards the definition of standardized procedures that will boost not only the scientific development of better bioinspired solutions, but also their market uptake.


Assuntos
Robótica , Marcha , Humanos , Locomoção , Robótica/métodos
6.
Sensors (Basel) ; 22(11)2022 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-35684614

RESUMO

Exoskeletons and exosuits have witnessed unprecedented growth in recent years, especially in the medical and industrial sectors. In order to be successfully integrated into the current society, these devices must comply with several commercialization rules and safety standards. Due to their intrinsic coupling with human limbs, one of the main challenges is to test and prove the quality of physical interaction with humans. However, the study of physical human-exoskeleton interactions (pHEI) has been poorly addressed in the literature. Understanding and identifying the technological ways to assess pHEI is necessary for the future acceptance and large-scale use of these devices. The harmonization of these evaluation processes represents a key factor in building a still missing accepted framework to inform human-device contact safety. In this review, we identify, analyze, and discuss the metrics, testing procedures, and measurement devices used to assess pHEI in the last ten years. Furthermore, we discuss the role of pHEI in safety contact evaluation. We found a very heterogeneous panorama in terms of sensors and testing methods, which are still far from considering realistic conditions and use-cases. We identified the main gaps and drawbacks of current approaches, pointing towards a number of promising research directions. This review aspires to help the wearable robotics community find agreements on interaction quality and safety assessment testing procedures.


Assuntos
Exoesqueleto Energizado , Robótica , Desenho de Equipamento , Humanos , Robótica/métodos
7.
IEEE Trans Neural Syst Rehabil Eng ; 28(7): 1573-1583, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32634096

RESUMO

Benchmarks have long been used to verify and compare the readiness level of different technologies in many application domains. In the field of wearable robots, the lack of a recognized benchmarking methodology is one important impediment that may hamper the efficient translation of research prototypes into actual products. At the same time, an exponentially growing number of research studies are addressing the problem of quantifying the performance of robotic exoskeletons, resulting in a rich and highly heterogeneous picture of methods, variables and protocols. This review aims to organize this information, and identify the most promising performance indicators that can be converted into practical benchmarks. We focus our analysis on lower limb functions, including a wide spectrum of motor skills and performance indicators. We found that, in general, the evaluation of lower limb exoskeletons is still largely focused on straight walking, with poor coverage of most of the basic motor skills that make up the activities of daily life. Our analysis also reveals a clear bias towards generic kinematics and kinetic indicators, in spite of the metrics of human-robot interaction. Based on these results, we identify and discuss a number of promising research directions that may help the community to attain a comprehensive benchmarking methodology for robot-assisted locomotion more efficiently.


Assuntos
Exoesqueleto Energizado , Fenômenos Biomecânicos , Humanos , Locomoção , Extremidade Inferior , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...