Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
1.
J Clin Med ; 13(12)2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38930099

RESUMO

Background and Objectives: Management of acetabular fractures is aimed at anatomically reducing and fixing all displaced or unstable fractures, as the accuracy of fracture reduction has been demonstrated to strongly correlate with clinical outcomes. However, there is a noticeable gap in the literature concerning the perioperative and postoperative care of patients with acetabular fractures, which ultimately can be potential risk factors for adverse outcomes and permanent disabilities. This study aimed to systematically review the available literature regarding rehabilitation practices, including weight-bearing protocols, across time points in surgically treated acetabular fracture patients and correlate these practices with functional outcomes. Methods: We systematically reviewed the Medline and PubMed databases and the Cochrane Central Register of Controlled Trials in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The inclusion criteria were studies with adult patients (19+ years), publications from the last 10 years, articles focusing on rehabilitation or mentioning any aspect related to rehabilitation (such as weight-bearing or muscle training), and describing the surgical management of acute, isolated acetabulum fractures. Specific information was collected, including the fracture classification, time to surgery, surgical approach, surgical time, blood loss, fixation strategy, quality of reduction, postoperative rehabilitation protocol, complication rate, type(s) of complication, and outcome measurement(s). The choice(s) of surgical approach, surgical time, blood loss, and fixation strategy were stratified based on the fracture classification. The complication rate and type(s) of complication were calculated for all studies. Fractures were classified based on the Letournel classification. Results: A total of 494 articles were identified from the initial search, of which 22 (1025 patients) were included in the final review. The most common rehabilitation protocol favored isometric quadriceps and abductor strengthening exercises starting on the first postoperative day, with passive hip movement at 1-3 days postoperatively and active hip movement ranging from the first postoperative day to 4 weeks postoperatively. Partial weight-bearing with a walker or a pair of crutches was permitted from 1 to 12 weeks after surgery, and full weight-bearing was allowed depending on the patient's general condition and fracture healing state (generally at the end of 3 months). In only three studies did the patients start bearing weight in the early postoperative period (≤1 week). Meta-regression analysis was not performed due to the discrepancy between studies that reported a weight-bearing protocol ≤1 week and >1 week postoperatively. Conclusions: Our study suggests that an accelerated postoperative rehabilitation protocol, including early permissive weight-bearing, does not appear to increase the risk of loss of reduction or the rate of complications after surgical treatment of acetabular fractures. However, a proper meta-analysis was not possible, and the heterogeneity of the included studies did not allow us to conclude anything about the potential biomechanical and clinical benefits nor the negative effects related to this rehabilitation regimen in terms of functional results. There is an inconsistent use of PROMs for objectively calculating the effect size of the accelerated protocol compared with restricted weight-bearing regimes. We pose the need for higher-level evidence to proof our hypothesis.

2.
Acta Ortop Bras ; 32(1): e272375, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38532865

RESUMO

Objective: To report on the experience and impressions of the Brazilian orthopedic trauma surgeons attending the Leadership Development Program (LDP) hosted by the Sociedade Brasileira do Trauma Ortopédico (SBTO) in Sao Paulo, Brazil on November 4, 2022. Methods: Forty-eight orthopedic trauma surgeons from five different regions throughout Brazil were provided a link to complete The Big Five Test, a validated online personality assessment. The questionnaire was available in Portuguese and was intended to provide a background on individual personality traits and their influence on interpersonal interactions. The LDP integrated content from literature reviews specific to Latin America, established leadership programs from leading business schools, and various subject matter experts. Prior to the start of the LDP, participants received a pre-course survey evaluating demographic information, a needs assessment, and the prioritization of leadership topics utilizing a 5-point Likert-scale. Attendees participated in the one-day, interactive LDP focusing on the fundamental principles of leadership development, communication, personal development, emotional intelligence and negotiation. Following the LDP, a post-course evaluation was administered to determine the participants' overall experience, and suggestions for LDP improvement. Results: Forty-one of the forty-eight course participants completed the pre-course evaluation, whereas forty-six of the forty-eight participants completed the post-course evaluations. Overwhelmingly, the lack of opportunity was most prevalently reported as the main obstacle to attending a leadership course, as cited by 56% of respondents. Conclusion: Expanding the accessibility, diversity, and customizability of leadership programs can facilitate the development of personal tools needed to move healthcare forward. Critical topics include emotional intelligence and other differentiating leadership qualities that distinguish true transformational and servant leaders. Advancing leadership skills can stimulate networking, expose learners to experiential learning styles, inspire others to create positive change, and engender creative solutions for systematic improvements and health outcomes. Level of Evidence III; Individual Case-Control Studies.


Objetivo: Relatar a experiência e as impressões de cirurgiões de trauma ortopédico brasileiros participantes do Programa de Desenvolvimento de Liderança (PDL), organizado pela Sociedade Brasileira do Trauma Ortopédico (SBTO), em São Paulo, Brasil, em 4 de novembro de 2022. Métodos: Quarenta e oito cirurgiões de trauma ortopédico de cinco regiões diferentes do Brasil receberam um link para preencher o The Big Five Test, uma avaliação de personalidade on-line validada. O questionário estava disponível em português e pretendia fornecer informações básicas sobre traços de personalidade individuais e sua influência nas interações interpessoais. O PDL integrou conteúdo de análises de literatura específicas da América Latina, e programas de liderança estabelecidos pelas principais escolas de negócios e por vários especialistas no assunto. Antes do início do PDL, os participantes receberam uma pesquisa pré-curso solicitando informações demográficas, uma avaliação de necessidades e a priorização de tópicos de liderança utilizando uma escala Likert de 5 pontos. Os participantes participaram do PDL interativo de um dia com foco nos princípios fundamentais de desenvolvimento de liderança, comunicação, desenvolvimento pessoal, inteligência emocional e negociação. Após o PDL, foi realizada uma avaliação pós-curso para determinar a experiência geral dos participantes e sugestões para melhoria do PDL. Resultados: Quarenta e um dos quarenta e oito participantes do curso concluíram a avaliação pré-curso, enquanto quarenta e seis dos quarenta e oito participantes concluíram a avaliação pós-curso. A falta de oportunidade foi relatada com maior prevalência como o principal obstáculo para frequentar um curso de liderança, conforme citado por 56% dos entrevistados. Conclusão: Expandir a acessibilidade, a diversidade e a personalização dos programas de liderança podem facilitar o desenvolvimento de ferramentas pessoais necessárias para fazer avançar os cuidados de saúde. Os tópicos críticos incluem inteligência emocional e outras qualidades de liderança diferenciadas, que distinguem verdadeiros líderes transformacionais e servidores O avanço das competências de liderança pode estimular o networking, expor os alunos a estilos de aprendizagem experiencial, inspirar outros a criar mudanças positivas e gerar soluções criativas para melhorias sistemáticas dos resultados na saúde. Nível de Evidência III; Estudos de caso-controle individuais.

4.
Injury ; 55(2): 111219, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38029682

RESUMO

OBJECTIVE: Compare the biomechanical effectiveness of four different bone-implant constructs in preventing fracture displacement under axial loading. METHODS: Twenty artificial femora had a standardized coronally oriented fracture of the lateral femoral condyle, representing a Hoffa fracture classified as a Letenneur type I. Four different fixation constructs were applied to the synthetic bones for biomechanical testing. The constructs consisted of a posterolateral (PL) buttressing locking plate in conjunction with two cannulated lag screws inserted from posterior to anterior (PA) - Group 1; Two cannulated screws inserted from anterior to posterior (AP) without plating- Group 2; A posterolateral (PL) buttressing locking plate in isolation - Group 3; and a combination of two lag screws from anterior to posterior (AP) in addition to a horizontal one-third tubular locking plate - Group 4. An axial load was applied to the fracture site with a constant displacement speed of 20 mm/min, and the test was interrupted when a secondary displacement was detected determining a fixation failure. We recorded the maximum applied force and the maximum fracture displacement values. RESULTS: Group 1 demonstrated the highest overall bone-implant axial stiffness with the lowest secondary displacement under loading. Groups 3 and 4 showed equivalent mechanical behavior. Group 2 presented the lowest mechanical stiffness to axial loading. The combination of the one-third tubular locking plate with anterior-to-posterior lag screws (Group 4) resulted in 302 % increase in fixation stiffness when compared to anterior-to-posterior lag screws only (Group 2). CONCLUSIONS: This study confirms the mechanical superiority of having a plate applied parallel to the main fracture plane in the setting of coronally oriented femoral condyle fractures. The addition of a horizontal plate, perpendicular to the main fracture plane, significantly increased the resistance to shearing forces at the fracture site when compared to constructs adopting just cannulated screws. LEVEL OF EVIDENCE: Biomechanical study.


Assuntos
Fraturas do Fêmur , Fratura de Hoffa , Humanos , Fenômenos Biomecânicos , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/complicações , Epífises , Placas Ósseas
5.
Injury ; 55(2): 111175, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37926664

RESUMO

OBJECTIVE: The aim of this study is to investigate stiffness and the maximum load to failure values of single- and double-screw fixation of oblique medial malleolus fractures using partially threaded cancellous screws. Our hypothesis is that single-screw fixation of medial malleolus fractures after SER injuries provides similar stiffness when compared with double-screw fixation. DESIGN: Biomechanical study. METHODS: Twelve composite polyurethane synthetic right distal tibiae were used in the experiment. Oblique fractures of the medial malleolus were created with a band saw using a custom-made osteotomy guide to standardize the cuts in all models. Bone models were randomly separated into two groups and fixed with one (n = 6) or two (n = 6) 4.0 mm partially threaded cancellous screws placed perpendicular to the fracture line. These were tested by applying an offset axial tension at 10 mm/minute up to maximum load displacement, defined as subsidence of the medial malleolus fragment. Maximum load to failure was determined for the groups at the point where the curve ceased to be linear and suffered an inflection. Force versus displacement curves were obtained and recorded. The student's t-test for independent samples was used to compare stiffness (N / mm) and maximum load (N) between experimental groups, with a p value of < 0.05. RESULTS: There were no significant differences in stiffness (p = 0.290) and maximum load (p = 0.191) among the two fixation constructs. Mean stiffness was 62.26 (±SD 21.11) N/mm for double-screw fixation group and 48.24 (±SD 22.40) N/mm for single-screw fixation group. Mean maximum load was 387.83 (±SD 115.78) N for double-screw fixation group and 306.64 (±SD 81.97) N for single-screw fixation group. CONCLUSION: Fixation with one 4.0 mm partially threaded cancellous screw was not shown to be biomechanically inferior to fixation with two 4.0 mm partially threaded cancellous screws in an oblique fracture of the medial malleolus, supporting previous clinical studies that have shown that one screw is sufficient for fractures of the medial malleolus.


Assuntos
Fraturas do Tornozelo , Humanos , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Supinação , Fixação Interna de Fraturas , Parafusos Ósseos , Tíbia/cirurgia , Fenômenos Biomecânicos
6.
Acta ortop. bras ; 32(1): e272375, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1550003

RESUMO

ABSTRACT Objective: To report on the experience and impressions of the Brazilian orthopedic trauma surgeons attending the Leadership Development Program (LDP) hosted by the Sociedade Brasileira do Trauma Ortopédico (SBTO) in Sao Paulo, Brazil on November 4, 2022. Methods: Forty-eight orthopedic trauma surgeons from five different regions throughout Brazil were provided a link to complete The Big Five Test, a validated online personality assessment. The questionnaire was available in Portuguese and was intended to provide a background on individual personality traits and their influence on interpersonal interactions. The LDP integrated content from literature reviews specific to Latin America, established leadership programs from leading business schools, and various subject matter experts. Prior to the start of the LDP, participants received a pre-course survey evaluating demographic information, a needs assessment, and the prioritization of leadership topics utilizing a 5-point Likert-scale. Attendees participated in the one-day, interactive LDP focusing on the fundamental principles of leadership development, communication, personal development, emotional intelligence and negotiation. Following the LDP, a post-course evaluation was administered to determine the participants' overall experience, and suggestions for LDP improvement. Results: Forty-one of the forty-eight course participants completed the pre-course evaluation, whereas forty-six of the forty-eight participants completed the post-course evaluations. Overwhelmingly, the lack of opportunity was most prevalently reported as the main obstacle to attending a leadership course, as cited by 56% of respondents. Conclusion: Expanding the accessibility, diversity, and customizability of leadership programs can facilitate the development of personal tools needed to move healthcare forward. Critical topics include emotional intelligence and other differentiating leadership qualities that distinguish true transformational and servant leaders. Advancing leadership skills can stimulate networking, expose learners to experiential learning styles, inspire others to create positive change, and engender creative solutions for systematic improvements and health outcomes. Level of Evidence III; Individual Case-Control Studies.


RESUMO Objetivo: Relatar a experiência e as impressões de cirurgiões de trauma ortopédico brasileiros participantes do Programa de Desenvolvimento de Liderança (PDL), organizado pela Sociedade Brasileira do Trauma Ortopédico (SBTO), em São Paulo, Brasil, em 4 de novembro de 2022. Métodos: Quarenta e oito cirurgiões de trauma ortopédico de cinco regiões diferentes do Brasil receberam um link para preencher o The Big Five Test, uma avaliação de personalidade on-line validada. O questionário estava disponível em português e pretendia fornecer informações básicas sobre traços de personalidade individuais e sua influência nas interações interpessoais. O PDL integrou conteúdo de análises de literatura específicas da América Latina, e programas de liderança estabelecidos pelas principais escolas de negócios e por vários especialistas no assunto. Antes do início do PDL, os participantes receberam uma pesquisa pré-curso solicitando informações demográficas, uma avaliação de necessidades e a priorização de tópicos de liderança utilizando uma escala Likert de 5 pontos. Os participantes participaram do PDL interativo de um dia com foco nos princípios fundamentais de desenvolvimento de liderança, comunicação, desenvolvimento pessoal, inteligência emocional e negociação. Após o PDL, foi realizada uma avaliação pós-curso para determinar a experiência geral dos participantes e sugestões para melhoria do PDL. Resultados: Quarenta e um dos quarenta e oito participantes do curso concluíram a avaliação pré-curso, enquanto quarenta e seis dos quarenta e oito participantes concluíram a avaliação pós-curso. A falta de oportunidade foi relatada com maior prevalência como o principal obstáculo para frequentar um curso de liderança, conforme citado por 56% dos entrevistados. Conclusão: Expandir a acessibilidade, a diversidade e a personalização dos programas de liderança podem facilitar o desenvolvimento de ferramentas pessoais necessárias para fazer avançar os cuidados de saúde. Os tópicos críticos incluem inteligência emocional e outras qualidades de liderança diferenciadas, que distinguem verdadeiros líderes transformacionais e servidores O avanço das competências de liderança pode estimular o networking, expor os alunos a estilos de aprendizagem experiencial, inspirar outros a criar mudanças positivas e gerar soluções criativas para melhorias sistemáticas dos resultados na saúde. Nível de Evidência III; Estudos de caso-controle individuais.

7.
Medicine (Baltimore) ; 102(48): e36161, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38050206

RESUMO

BACKGROUND: Accomplish a thorough review on the existing biomechanical and clinical studies about coronal plane fractures of the distal femur. METHODS: We performed an electronic search of PubMed/MEDLINE database from April to June, 2023. The terms for the database search included "Hoffa fractures," OR "Busch-Hoffa fractures" OR "coronal plane fractures of the distal femur." RESULTS: The search identified 277 potentially eligible studies. After application of inclusion and exclusion criteria, 113 articles were analyzed in terms of the most important topics related to coronal plane fractures of the distal femur. CONCLUSION: Lateral coronal plane fractures of the distal femur are more frequent than medial, present a more vertical fracture line, and usually concentrate on the weight bearing zone of the condyle. The Letenneur system is the most used classification method for this fracture pattern. Posterior-to-anterior fixation using isolated lag screws (for osteochondral fragments-Letenneur type 2) or associated with a posterior buttressing plate (when the fracture pattern is amenable for plate fixation-Letenneur types 1 and 3) is biomechanically more efficient than anterior-to-posterior fixation. Anterior-to-posterior fixation using lag screws complemented or not by a plate remains a widely used treatment option due to the surgeons' familiarity with the anterior approaches and lower risk of iatrogenic neurovascular injuries. There is no consensus in the literature regarding diameter and number of screws for fixation of coronal plane fractures of the distal femur.


Assuntos
Fraturas do Fêmur , Fratura de Hoffa , Humanos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Fêmur/cirurgia , Placas Ósseas
8.
Diagnostics (Basel) ; 13(23)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38066761

RESUMO

Introduction: We investigated the biomechanical behaviour of different fixations of the tibial posterior malleolus (TPM), simulating distinct situations of involvement of the tibiotalar articular surface (TTAS) through a finite element model (FEM). Material and methods: A 3D computer-aided design model of the left ankle was obtained. The materials used were divided according to their characteristics into ductile and non-ductile, and all materials were assumed to be linear elastic, isotropic, and homogenous. Three different fracture lines of the TPM were defined, with sagittal angles of 10°, 25°, and 45°. For biomechanical comparison, different constructions using a trans-syndesmotic screw (TSS) only (Group T), a one-third tubular plate only with (Group PT) and without (Group PS) a TSS, and a locked compression plate with (Group LCPT) and without (Group LCPS) a TSS were tested. FEM was used to simulate the boundary conditions of vertical loading. Load application regions were selected in the direction of the 700 N Z-axis, 90% on the tibia and 10% on the fibula. Data on the displacement and stress in the FEM were collected, including the total principal maximum (MaxT) and total principal minimum (MinT) for non-ductile materials, total displacement (desT), localized displacement at the fragment (desL), localized displacement at syndesmosis (desS), and Von Mises equivalent stress for ductile materials. The data were analysed using ANOVA and multiple comparison LSD tests were used. Results: For TPM fractures with sagittal angles 10° and 25°, desL in the PT and LCP groups was significantly lower, as well as Von Mises stress in Group LCPT in 10°, and PT and LCPT groups in 25°. For TPM fractures with a sagittal angle of 45°, desL in the LCP group and Von Mises stress in Group LCPS and LCPT were significantly lower. We found that any TPM fracture may indicate instability of the distal tibiofibular syndesmosis, even when the fragment is small. Conclusion: Our study showed that in fragments involving 10% of the TTAS, the use of a TSS is sufficient, but when the involvement is greater than 25% of the TTAS, either a non-locked or locked plate must be used to buttress the TPM. In posterior fragments affecting 45% or more of the TTAS, the use of a locking plate is recommended.

10.
Injury ; 54 Suppl 6: 110774, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38143123

RESUMO

OBJECTIVE: The aim of this study was to evaluate the Latin American orthopaedic trauma surgeons preference regarding knee positioning and entry portals for IM nailing and identify the reasons of these preferences. METHODS: Using the AO Trauma database, 22.285 surveys were distributed by email to Latin American orthopaedic surgeons. Demographic data and practice patterns, especially regarding knee positioning and approach for tibial nailing, were then evaluated and statistically treated. RESULTS: amongst one thousand five hundred fourteen responses, 990 orthopaedic surgeons (4.4% of response rate) fully responded to the survey. Transpatellar tendon approach (613 / 61.9%,) with the knee in flexion (518 / 52.3%) on a radiolucent table remains the standard practice for intramedullary tibial nailing. Even for proximal and distal tibial nailing, the transpatellar tendon approach (455 / 46%) with the knee in flexion (562 / 56.8%) hold on the most used method. Only 55 (9.36%) orthopaedic surgeons reported that they have migrated to the supra-patellar tibial nailing in the recent years. The main reasons for a low rate of migration were lack of knowledge about the technique and unavailability of specific gigs and cartilage protectors for a safe suprapatellar nailing. CONCLUSION: Even with the potential benefits of the semi-extended knee positioning for tibial nailing, the Latin American orthopaedic community remains using the transpatellar tendon approach with the knee in flexion as the standard technique. Lack of surgical training for suprapatellar and parapatellar approaches with the knee in semi-extension, added by the unavailability of suprapatellar jigs and soft outer protection sleeves contribute to counter the trend towards the semi-extended techniques.


Assuntos
Fixação Intramedular de Fraturas , Cirurgiões Ortopédicos , Fraturas da Tíbia , Humanos , América Latina , Fixação Intramedular de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Tíbia/cirurgia , Pinos Ortopédicos
11.
Injury ; 54 Suppl 6: 110783, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38143127

RESUMO

Vertically unstable pelvic injuries associated with sacroiliac disruption are challenging. Although percutaneous iliosacral fixation using two screws at S1 vertebral body has been shown beneficial, the use of two transiliac screws at S1 has been proposed to increase the fixation strength of the construct. In the herein study, the finite element method (FEM) was performed to analyse the biomechanical behaviour of five different constructions using iliosacral screws only, transiliac screws only, and combining an iliosacral and a transiliac screw. A vertically unstable AO 61C1.2 type pelvic injury was produced for the evaluation of the posterior pelvic displacement and implant stress, and the anterior implant stress using FEM. The symphysis pubis was fixed with a 3.5-mm reconstruction plate in all cases. The model was axially loaded with 800N applied in the centre of S1 body, perpendicular to the ground (Y-axis), simulating the bipodal stance moment. There was a statistically significant reduction in both posterior displacement and implant stresses in the groups fixed with at least one transiliac screw compared to the groups fixed with iliosacral screws. In our FEM study, the construct using two transiliac screws in S1 is biomechanically superior for stabilizing the sacroiliac joint in vertically unstable pelvic ring injuries compared to the other configurations. Lateral displacement, posterior displacement, and von Mises stress were reduced with this construct. A good option can be the use of one iliosacral screw and one transiliac screw in S1.


Assuntos
Fraturas Ósseas , Instabilidade Articular , Ossos Pélvicos , Humanos , Articulação Sacroilíaca/cirurgia , Articulação Sacroilíaca/lesões , Fixação Interna de Fraturas/métodos , Análise de Elementos Finitos , Parafusos Ósseos , Fraturas Ósseas/cirurgia , Fenômenos Biomecânicos , Ossos Pélvicos/cirurgia , Ossos Pélvicos/lesões , Sacro/cirurgia , Sacro/lesões
12.
Injury ; 54 Suppl 6: 110811, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38143130

RESUMO

INTRODUCTION: Ankle fractures are one of the most frequent injuries managed by any trauma surgeon. Literature has shown that adequate reduction is of utmost importance to achieve satisfactory functional outcomes. However, malreduction rates remain high worldwide. The objective of the present study is to evaluate the quality of ankle fracture reduction in two major trauma centers in a large Brazilian city and to analyze the factors associated with malreduction METHODS: Epidemiologic data of 382 patients (189 men; 193 women) aged between 7 and 87 years who underwent osteosynthesis of the ankle in two trauma centers in a large Brazilian city. Electronic clinical records, preoperative and immediate postoperative radiographs in anteroposterior (AP), lateral and mortise views were evaluated. Pettrone's criteria were used to evaluate the quality of ankle fractures reduction. All radiographs were independently evaluated by two foot and ankle senior surgeons RESULTS: Overall, malreduction rate was 22.2%. Forty-seven (55.2%) fractures classified as malreduced had medial malleolar displacement The results showed three factors that significantly affected the quality of reduction (p<0.05), patients over 60 years, open fractures and fracture-dislocations. Patients aged over 60 years were twice more likely to have poor reduction of ankle fractures than younger ones. The risk of poor fracture reduction among those individuals with open fractures is 2.15 times greater than among patients with closed injuries. Fracture-dislocation imposed a 2.7 higher risk for malreduction DISCUSSION: We found a malreduction rate below most series previously published. Further results agree with the literature. Elderly people aged over 60 years, fracture dislocations and open fractures are associated with worse results, influencing the quality of the reduction, clinical outcomes, and the development of post-traumatic arthrosis CONCLUSION: Ankle fractures malreduction are associated with higher age, open fractures, and fracture-dislocations.


Assuntos
Fraturas do Tornozelo , Fratura-Luxação , Fraturas Expostas , Idoso , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Criança , Adolescente , Adulto Jovem , Adulto , Idoso de 80 Anos ou mais , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Fraturas Expostas/cirurgia , Tornozelo , Brasil/epidemiologia , Tomografia Computadorizada por Raios X , Fixação Interna de Fraturas/métodos , Hospitais , Resultado do Tratamento , Estudos Retrospectivos
13.
Injury ; 54 Suppl 6: 110810, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38143133

RESUMO

Femoral neck fractures (FNFs) affect the young adult population and are intimately related to high-energy trauma. Despite innovations in osteosynthesis materials, the rate of complications remains at 10%-59% in Pauwels type III (PIII) fractures. The authors thus propose a fixation model with a novel self-compression screw, comparing it to a sliding hip screw plate associated with a derotation screw in the fixation of a PIII fracture with posterior inferior comminution. The finite element method (FEM) was used in this comparison along with a virtual femur model with structural characteristics similar to those of a healthy young human bone. We formed 4 groups: Group 1 (GC), intact bone; Group 2 (SHS+S), sliding hip screw plate with derotation screw; Group 3 (XS), X-pin + SS (self-compression model with superior positioning screw); Group 4 (XI), X-pin + IS (self-compression model with inferior positioning screw). A 700 N monotonic load was applied to the apex of the femur head towards the ground so that stress was mainly focused on the fracture site and osteosynthesis. Analyses included total displacement and maximum principal stress and were performed for all groups. Fracture displacement, rotation, and von Mises were assessed only in groups that underwent osteosynthesis. Total displacement values in groups with self-compression screws (XS and XI) were closer to those for healthy femurs, with a 38.5% reduction when comparing the XS group with the SHS+S group. Fracture displacement and rotation values presented reductions of over 60% when comparing the XS and XI groups with the SHS+S group. Equivalent Von Mises stress values were similar between XS and XI and presented a reduction of approximately 5.25% when compared with the SHS+S group. Our FEM analyses demonstrated that the self-compression screw model has potential biomechanical advantages over the SHS+S model.


Assuntos
Fraturas do Colo Femoral , Humanos , Fraturas do Colo Femoral/cirurgia , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fêmur/cirurgia , Cabeça do Fêmur/cirurgia , Fenômenos Biomecânicos , Análise de Elementos Finitos
14.
Injury ; 54 Suppl 6: 110579, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38143145

RESUMO

Antegrade fixation of posterior column fractures of the acetabulum is challenging due to the narrow corridor and risk of screw misplacement. Although both antegrade and retrograde lag screws have been previously described for posterior column fracture fixation, the literature lacks a standardized technique for correct and safe screw placement, especially in an antegrade fashion. This technical note aims to optimize intraoperative images during posterior screw insertion using the antegrade technique, according to predetermined landmarks to save surgical time, decrease radiation exposition, and prevent surgical complications.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Fraturas da Coluna Vertebral , Humanos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Parafusos Ósseos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Acetábulo/lesões
15.
Injury ; 54 Suppl 6: 110733, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38143149

RESUMO

Determining the true availability of resources and understanding the level of training of surgeons involved in the treatment of patients with pelvic fractures and haemorrhagic shock is critical. In the herein study, the availability of technical, technological, and human resources for the care of this injury in Latin America region was analysed, and the preferences of orthopaedic trauma surgeons when performing interventions for the diagnosis and treatment of patients with pelvic trauma and associated haemorrhagic shock was described. A cross sectional web-based survey containing questions on knowledge, attitudes, and practices with respect to imaging resources, emergency pelvic stabilization methods, and interventions used for bleeding control was sent to 948 Latin America orthopaedic trauma surgeons treating pelvic fractures in the emergency department. Differences between regional clusters, level of training, type of hospital, and pelvic surgery volume were assessed. 368 responses were obtained, with 37.5% of respondents reporting formal training in pelvic surgery and 36.0% having available protocol for managing these patients. The most frequently used interventions were the supra-acetabular pelvic external fixator and pelvic packing. Limited hospital and imaging resources are available for the care of patients with pelvic trauma and associated haemorrhagic shock throughout Latin America. In addition, the training of orthopaedic trauma surgeons dealing with this type of injury and the volume of pelvic surgeries per year is heterogeneous. It should be urgently considered to develop management protocols adapted to Latin America according to the availability of resources, as well as to promote training in this severe life-threatening traumatic condition.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Choque Hemorrágico , Humanos , Estudos Transversais , Choque Hemorrágico/terapia , Choque Hemorrágico/complicações , América Latina , Fraturas Ósseas/complicações , Fraturas Ósseas/cirurgia , Ossos Pélvicos/lesões
16.
Injury ; 54 Suppl 6: 110708, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38143148

RESUMO

BACKGROUND: Dysesthesia, electrical and burning sensations, in addition to allodynia are frequent symptoms of neuropathic pain. Despite the high frequency, scientific data on the development of neuropathic pain after surgery for fracture fixation are scarce. The goal of the present study was to determine the prevalence, risk factors, and evaluate potential associations among neuropathic pain, pain intensity, sociodemographic, and clinical variables after wrist, hip, and ankle fracture fixation. METHODS: A cross-sectional retrospective study involving a cohort of 166 patients who underwent surgery for distal radius, proximal femur, malleolar fracture fixation was performed. Neuropathic pain was assessed one year after fracture fixation using the Doleur Neuropathique Questionnaire (DN4). RESULTS: The incidence of neuropathic pain in our sample was 49 (29.5%). Predictors for the development of neuropathic pain included patients with a high body mass index (BMI), female gender, diabetes mellitus, long-term use of analgesics (especially using pain-modulating medication), patients who presented some fracture-related complication during the course of the treatment, who had limitations for daily activity, and who were away from work due to chronic pain. CONCLUSION: In our study, neuropathic pain after wrist, hip, and ankle fracture fixation was prevalent and associated with higher BMI values and amount of medication, in addition to higher proportions of female sex, absence from work, DM, limitation for daily activities, postoperative complications, and use of pain modulating medications.


Assuntos
Fraturas do Tornozelo , Dor Crônica , Neuralgia , Humanos , Feminino , Fraturas do Tornozelo/epidemiologia , Fraturas do Tornozelo/cirurgia , Fraturas do Tornozelo/complicações , Estudos Retrospectivos , Punho , Prevalência , Estudos Transversais , Fixação Interna de Fraturas/efeitos adversos , Fatores de Risco , Dor Crônica/epidemiologia , Neuralgia/epidemiologia , Neuralgia/etiologia
17.
Injury ; 54 Suppl 6: 110898, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38143112

RESUMO

Postoperative bone infection is a severe complication in the treatment of fractures. The management of this pathology is challenging, but recent advances have been made to achieve standardization that can help diagnosis and decision-making. However, we are unaware of studies validating these models in Latin America. Therefore, this study aims to collect data from patients with fracture-related infections treated in different institutions in Latin America to create a registry that will assist in future clinical decision-making regarding the diagnostic process and the surgical and medical treatment of these patients.


Assuntos
Fraturas Ósseas , Infecções , Humanos , Fraturas Ósseas/complicações , Fraturas Ósseas/microbiologia , Fraturas Ósseas/cirurgia , América Latina/epidemiologia , Sistema de Registros , Infecções/etiologia , Infecções/terapia
18.
Rev Bras Ortop (Sao Paulo) ; 58(3): 507-513, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37396077

RESUMO

Objective To evaluate the biomechanical capacity of two forms of fixation for Pipkin type-II fractures, describing the vertical fracture deviation, the maximum and minimum principal stresses, and the Von Mises equivalent stress in the syntheses used. Materials and Methods Two internal fasteners were developed to treat Pipkin type-II fractures through finite elements: a 3.5-mm cortical screw and a Herbert screw. Under the same conditions, the vertical fracture deviation, the maximum and minimum principal stresses, and the Von Mises equivalent stress in the syntheses used were evaluated. Results The vertical displacements evaluated were of 1.5 mm and 0.5 mm. The maximum principal stress values obtained in the upper region of the femoral neck were of 9.7 KPa and 1.3 Kpa, and the minimum principal stress values obtained in the lower region of the femoral neck were of -8.7 KPa and -9.3 KPa. Finally, the peak values for Von Mises stress were of 7.2 GPa and 2.0 GPa for the fixation models with the use of the 3.5-mm cortical screw and the Herbert screw respectively. Conclusion The fixation system with the Herbert screw generated the best results in terms of reduction of vertical displacement, distribution of the maximum principal stress, and the peak Von Mises equivalent stress, demonstrating mechanical superiority compared to that of the 3.5-mm cortical screw in the treatment of Pipkin type-II fractures.

19.
Eur J Trauma Emerg Surg ; 49(5): 2057-2069, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37160440

RESUMO

PURPOSE: To systematically review the currently available existing evidence related to the presentation and management of simultaneous floating hip and knee injuries to identify injury characteristics, treatment strategies, and complications. METHODS: Data sources: Relevant articles were identified by searching Medline, PubMed, and Google Scholar databases with no language restrictions. Manual searches of other relevant databases (SciELO and grey literature databases) and reference lists of primary articles found from initial searches were also conducted. STUDY SELECTION: All types of study designs published from January 1st, 2000 to October 1st, 2022 involving skeletally mature patients with simultaneous floating hip and knee injuries were included. DATA EXTRACTION: Basic information and specific injury-related information were collected. RESULTS: Eight case reports were included. No study adequately reported the case with sufficient detail to allow other investigators to make inferences, nor was the result properly calculated, nor was the follow-up considered adequate for adequate functional assessment to occur in 80% of the studies. CONCLUSION: The exact treatment strategy and the follow-up time are not uniform across the included studies; therefore, they are not sufficient to adequately recommend surgical approach, timing of fixation, and fixation method. Our findings warrant the need for better documentation and reporting information about the mode of treatment of simultaneous floating hip and knee injuries.


Assuntos
Traumatismos do Joelho , Articulação do Joelho , Humanos , Articulação do Joelho/cirurgia , Traumatismos do Joelho/cirurgia , Fixação de Fratura/métodos , Extremidades
20.
Rev. bras. ortop ; 58(3): 507-513, May-June 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1449817

RESUMO

Abstract Objective To evaluate the biomechanical capacity of two forms of fixation for Pipkin type-II fractures, describing the vertical fracture deviation, the maximum and minimum principal stresses, and the Von Mises equivalent stress in the syntheses used. Materials and Methods Two internal fasteners were developed to treat Pipkin type-II fractures through finite elements: a 3.5-mm cortical screw and a Herbert screw. Under the same conditions, the vertical fracture deviation, the maximum and minimum principal stresses, and the Von Mises equivalent stress in the syntheses used were evaluated. Results The vertical displacements evaluated were of 1.5mm and 0.5mm. The maximum principal stress values obtained in the upper region of the femoral neck were of 9.7 KPa and 1.3 Kpa, and the minimum principal stress values obtained in the lower region of the femoral neck were of-8.7 KPa and -9.3 KPa. Finally, the peak values for Von Mises stress were of 7.2 GPa and 2.0 GPa for the fixation models with the use of the 3.5-mm cortical screw and the Herbert screw respectively. Conclusion The fixation system with the Herbert screw generated the best results in terms of reduction of vertical displacement, distribution of the maximum principal stress, and the peak Von Mises equivalent stress, demonstrating mechanical superiority compared to that of the 3.5-mm cortical screw in the treatment of Pipkin type-II fractures.


Resumo Objetivo Avaliar a capacidade biomecánica de duas formas de fixação de fraturas tipo II de Pipkin descrevendo o desvio da fratura no sentido vertical, as tensões máxima e mínima principais, e a tensão equivalente de Von Mises nas sínteses utilizadas. Materiais e Métodos Dois fixadores internos foram desenvolvidos para tratar a fratura tipo II de Pipkin por meio de elementos finitos: parafuso cortical de 3,5 mm e parafuso de Herbert. Sob as mesmas condições, foram avaliados o desvio da fratura no sentido vertical, as tensões máxima e mínima principais, e a tensão equivalente de Von Mises nas sínteses utilizadas. Resultados Os deslocamentos verticais avaliados foram de 1,5 mm e 0,5 mm. Os valores de tensão máxima obtidos na região superior do colo femoral foram de 9,7 KPa e 1,3 KPa, e os valores de tensão mínima obtidos na região inferior do colo femoral foram de -8,7KPa e -9,3 KPa. Por fim, os valores de pico da tensão equivalente de Von Misesforam de 7,2 GPa e2,0 GPa paraosmodelos de fixação com o uso do parafuso cortical de 3,5 mm e do parafuso de Herbert, respectivamente. Conclusão Osistema de fixação com parafuso de Herbert gerou os melhores resultados em termos de redução do deslocamento vertical, distribuição da tensão máxima e do pico da tensão equivalente de Von Mises, o que demonstra sua superioridade mecânica comparada à do parafuso cortical de 3,5 mm no tratamento da fratura tipo II de Pipkin.


Assuntos
Humanos , Parafusos Ósseos , Cabeça do Fêmur/cirurgia , Fraturas do Quadril/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...