Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Urol Open Sci ; 33: 28-41, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34604814

RESUMO

CONTEXT: Benign prostatic hyperplasia (BPH) associated with lower urinary tract symptoms (LUTS) is diagnosed in up to 80% of men during their lifetime. Several novel ultra-minimally invasive surgical treatments (uMISTs) for BPH/benign prostatic obstruction (BPO) have become available over the past 5 yr. OBJECTIVE: To evaluate the perioperative and functional outcomes of recently introduced uMISTs for BPH/BPO, including Urolift, Rezum, temporary implantable nitinol device, prostatic artery embolization (PAE), and intraprostatic injection. EVIDENCE ACQUISITION: A systematic literature search was conducted in December 2020 using Medline (via PubMed), Embase (via Ovid), Scopus, and Web of Science (registered on PROSPERO as CRD42021225014). The search strategy used PICO criteria and article selection was conducted in accordance with the PRISMA guidelines. The risk of bias and the quality of the articles included were assessed. A dedicated data extraction form was used to collect the data of interest. Pooled and cumulative analyses were performed to compare perioperative and functional outcomes between study groups. A random-effects model using the DerSimonian and Laird method was used to evaluate heterogeneity. Stata version 15.0 software was used for all statistical analyses. EVIDENCE SYNTHESIS: The initial electronic search identified 3978 papers, of which 48 ultimately met the inclusion criteria and were included in the analysis. Pooled analysis revealed a uMIST benefit in terms of International Prostate Symptom Score (IPSS; -9.81 points, 95% confidence interval [CI] -11.37 to -8.25 at 1 mo; -13.13 points, 95% CI -14.98 to -11.64 at 12 mo), maximum flow rate (from +3.66 ml/s, 95% CI 2.8-4.5 to +4.14 ml/s, 95% CI 0.72-7.56 at 12 mo), and postvoid residual volume (-10.10 ml, 95% CI -27.90 to 7.71 at 12 mo). No negative impact was observed on scores for the International Index of Erectile Function-5, Male Sexual Health Questionnaire-Ejaculatory Dysfunction bother and function scales (overall postintervention change in pooled median score of 1.88, 95% CI 1.34-2.42 at the start of follow-up; and 1.04, 95% CI 0.28-1.8 after 1 yr), or the IPSS-Quality of Life questionnaire. CONCLUSIONS: Novel uMISTs can yield fast and effective relief of LUTS without affecting patient quality of life. Only Rezum, UroLift, and PAE had a minimal impact on patients' sexual function with respect to baseline, especially regarding preservation of ejaculation. PATIENT SUMMARY: We reviewed outcomes for recently introduced ultra-minimally invasive surgical treatments for patients with lower urinary tract symptoms caused by benign prostate enlargement or obstruction. The evidence suggests that these novel techniques are beneficial in terms of controlling symptoms while preserving sexual function. TAKE HOME MESSAGE: Novel ultra-minimally invasive treatments can yield fast and effective relief of lower urinary tract symptoms without affecting a patient's quality of life.

2.
Eur J Orthop Surg Traumatol ; 31(7): 1471-1476, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33625574

RESUMO

BACKGROUND: Proper acetabular cup positioning is crucial for achieving implant longevity and stability in total hip arthroplasty (THA). One of the elements that may affect the accuracy and precision of the positioning of the cup is the type of surgical approach used. This study compares the accuracy and the precision of conventional free-hand acetabular cup positioning relative to different "safe zones" in two groups of patients operated with THA using two different surgical approach. METHODS: Retrospective radiological comparative matched-pair controlled study of two groups of patients operated with primary THA: the first group was operated in supine decubitus with a mini-invasive direct anterior approach (DA group), the second group was operated in lateral decubitus with a conventional posterolateral approach (PL group). Cup inclination and anteversion were assessed using the digital planning software TraumaCad. Cup position in the two groups were compared in terms of accuracy and precision. RESULTS: Forty four patients were enrolled for each group. The DA group showed a less inclined and less anteverted cup compared to the PL group (respectively 38.5 ± 5.2 vs. 49.6 ± 5.6 and 16.2 ± 3.6 vs. 22.9 ± 6.4; p < 0.01). The DA group showed a significantly higher percentage of cups within the "safe zone" in 4 out of 6 reference zones and a significantly lower variance in anteversion (12.96 vs. 40.96, p < .01). There was no difference in the variance for inclination. CONCLUSIONS: Our study found greater accuracy and precision in the positioning of the cup when surgery was performed through a direct anterior approach compared to the posterolateral approach due to the supine position of the patient which allows greater stability of the pelvis during surgery and makes it easier to target the desired angular references for cup positioning.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Fluoroscopia , Humanos , Estudos Retrospectivos
3.
Eur J Orthop Surg Traumatol ; 30(8): 1471-1472, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32797350

RESUMO

The original version of this article unfortunately contained a mistake. Figures 3 and 4 captions were interchanged.

4.
Eur J Orthop Surg Traumatol ; 30(8): 1463-1470, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32613469

RESUMO

INTRODUCTION: Accurate reconstruction of biomechanical parameters following total hip arthroplasty (THA) is crucial for good joint function. We investigated how reconstruction parameters achieved by minimally invasive anterior (MIS) THA may influence function and patient-related outcomes. METHODS: A consecutive series of 95 patients treated by MIS THA for primary osteoarthritis were retrospectively reviewed. Primary outcome measures were Harris Hip Score (HHS), hip disability and osteoarthritis outcome score (HOOS) and EQ-5D. Femoral offset (FO), abductor lever arm (ALA), centre of rotation (CoR), leg length discrepancy (LLD), cup version and stem alignment were measured pre- and post-operatively. Obtained reconstruction parameters compared to the contralateral hip were used as independent variables in a multivariate regression with each primary outcome measure as dependent variable. RESULTS: Mean age at surgery was 69 years. HHS rated 94.7% of patients as good/excellent and mean EQ-5D was 0.82. Post-operative HOOS subscales showed no statistical difference compared to the Italian benchmark population. Stem alignment averaged 0.2° valgus, mean cup inclination was 37.8° and mean anteversion was 12.8°. When compared to the contralateral side, CoR was post-operatively elevated by 2.6 mm and medialized by 2.4 mm averagely. An average FO reduction of -0.5 mm was observed while FO ratio increased by 1.9% averagely. ALA decreased by -3.3 mm while LLD was 2.3 mm averagely. Multivariate regression analysis revealed a significant contribution of ALA to HHS only. CONCLUSIONS: Biomechanical parameters achieved by MIS THA are satisfactory with negligible impact on functional results and no impact on patient-related outcomes certifying the high quality achieved in THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteoartrite do Quadril , Artroplastia de Quadril/efeitos adversos , Articulação do Quadril/cirurgia , Humanos , Desigualdade de Membros Inferiores , Osteoartrite do Quadril/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
5.
J Orthop Traumatol ; 19(1): 21, 2018 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-30535952

RESUMO

BACKGROUND: Large-diameter head metal-on-metal (MoM) bearings in total hip arthroplasty (THA) are associated with increased whole blood levels of chromium (Cr) and cobalt (Co), adverse reactions to metal debris (ARMD) and poor survival rates. The prevalence of high metals concentrations, ARMD and the risk of revision surgery may vary significantly among different prostheses and long-term studies are few. This single-center study reports the long-term results of the 38-mm MoM bearing system. MATERIALS AND METHODS: Between 2003 and 2009, 80 patients received primary cementless THA using the large head metal-on-metal articulating surface M2A-38 cup (Biomet, Inc., Warsaw, IN, USA) at a single institution. Forty-five patients (53 hips) were retrospectively reviewed for a mean follow-up of 127 months. RESULTS: Two cups were revised. The cumulative implant survival rate was 98% at 10 years and 74% at 13 years. In the whole sample, the median Co and Cr concentrations were 4.8 µg/L (IQR 1.2-4.9 µg/L) and 2.5 µg/L (IQR 0.6-3.0 µg/L), respectively. The incidence of Co or Cr levels > 7 µg/L was 15.5% and the incidence of ARMD was 3.8%. Co and Cr levels showed no correlation with cup inclination, Harris Hip Score, or total Hip Disability and Osteoarthritis Outcome score. CONCLUSIONS: Our results confirm that the problems of release of metal ions with the possible increase of metal circulating levels and of adverse reactions may also occur in the long term with this brand of MoM large head, and that a structured follow-up program is mandatory. LEVELS OF EVIDENCE: Level 4.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Próteses Articulares Metal-Metal , Osteoartrite do Quadril/cirurgia , Amplitude de Movimento Articular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/fisiopatologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...