1.
J Virol Methods ; : 114988, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38908550

RESUMO

We evaluated the use of the Product Enhanced Reverse Transcriptase (PERT) assay as a means of detecting virus in retroviral vectors products pseudotyped with Gibbon Ape Leukemia Virus (GALV) and Vesicular Stomatitis Virus G (VSVG) envelopes. PERT provides greater standardization than the S+/L- assay which has been used extensively in virus detection. A challenge is that PERT will also detect residual retroviral vectors as vector particles contain reverse transcriptase. Vector products were cultured for 3 weeks on HEK293 cells to amplify any potential virus. In addition, vector supernatant and end-of-production cells were spiked with GALV to evaluate for inhibition by the test article. Results of PERT and the S+/L- assay were compared. PERT and S+/L- assays were both effective in detecting virus. Vector supernatants were negative at the end of 3 weeks of culture by PERT for both GAVL and VSVG pseudotyped vector. In contrast, end-of-production cells were positive by PERT due to persistent vector producing cells. A one-week culture of cell-free media obtained at the 3 weeks timepoint allowed distinction of virus-free test articles from those with virus. The PERT assay is suitable for detecting replication competent retrovirus in vector products pseudotyped with GALV and VSVG envelopes.