Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
J Am Coll Cardiol ; 81(7): 653-664, 2023 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36792280

RESUMO

BACKGROUND: Chronic thromboembolic pulmonary hypertension (CTEPH) is characterized by obstruction of major pulmonary arteries with organized thrombi. Clinical risk factors for pulmonary hypertension due to left heart disease including metabolic syndrome, left-sided valvular heart disease, and ischemic heart disease are common in CTEPH patients. OBJECTIVES: The authors sought to investigate prevalence and prognostic implications of elevated left ventricular filling pressures (LVFP) in CTEPH. METHODS: A total of 593 consecutive CTEPH patients undergoing a first diagnostic right and left heart catheterization were included in this study. Mean pulmonary arterial wedge pressure (mPAWP) and left ventricular end-diastolic pressure (LVEDP) were utilized for assessment of LVFP. Two cutoffs were applied to identify patients with elevated LVFP: 1) for the primary analysis mPAWP and/or LVEDP >15 mm Hg, as recommended by the current pulmonary hypertension guidelines; and 2) for the secondary analysis mPAWP and/or LVEDP >11 mm Hg, representing the upper limit of normal. Clinical and echocardiographic features, and long-term mortality were assessed. RESULTS: LVFP was >15 mm Hg in 63 (10.6%) and >11 mm Hg in 222 patients (37.4%). Univariable logistic regression analysis identified age, systemic hypertension, diabetes, atrial fibrillation, calcific aortic valve stenosis, mitral regurgitation, and left atrial volume as significant predictors of elevated LVFP. Atrial fibrillation, calcific aortic valve stenosis, mitral regurgitation, and left atrial volume remained independent determinants of LVFP in adjusted analysis. At follow-up, higher LVFPs were measured in patients who had meanwhile undergone pulmonary endarterectomy (P = 0.002). LVFP >15 mm Hg (P = 0.021) and >11 mm Hg (P = 0.006) were both associated with worse long-term survival. CONCLUSIONS: Elevated LVFP is common, appears to be due to comorbid left heart disease, and predicts prognosis in CTEPH.


Assuntos
Fibrilação Atrial , Hipertensão Pulmonar , Hipertensão , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/epidemiologia , Hipertensão Pulmonar/etiologia , Função Ventricular Esquerda , Pressão Propulsora Pulmonar , Pressão Ventricular
2.
PLoS One ; 15(7): e0235716, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32628737

RESUMO

BACKGROUND: The pulmonary artery (PA) to ascending aorta diameter ratio (PA:A) has been evaluated in numerous studies analyzing cardiac magnetic resonance (CMR) and computed tomography (CT) data. Previously, no transthoracic echocardiography (TTE) cutoffs have been published. We sought to evaluate (1) the feasibility to image the pulmonary trunk in a prospective cohort, and (2) the ability of PA:A derived by TTE to predict pulmonary hypertension (PH). METHODS: We performed a post-hoc analysis of a prospectively recruited consecutive cohort of patients referred to our tertiary center cardiology department due to suspicion for PH. Invasive hemodynamic assessment and quasi-simultaneous TTE was performed in all participants. RESULTS: A total of 84 patients were included in the analysis, median age was 70.5 years (IQR 58-75), 46 (55%) were female. The PA was significantly wider in the PH group (28mm vs. 22.5mm, p<0.001) with a resulting median PA:A of 0.84 vs. 0.66 (p<0.001). Both PA diameter (r = 0.524 and r = 0.44, both p<0.001) and PA:A (r = 0.652 and 0.697, both p<0.001) significantly correlated with mPAP and with PVR, respectively. Area under the curve for the detection of PH was 0.853 (95%CI 0.739-0.967, p<0.001). CONCLUSION: The PA can be visualized in almost all echocardiographic exams, especially when it is dilated. A view showing the pulmonary trunk should be included in every routine TTE. An increased PA:A should raise suspicion for PH and prompt further evaluation and follow-up examinations of these patients.


Assuntos
Aorta/diagnóstico por imagem , Ecocardiografia/métodos , Hipertensão Pulmonar/patologia , Artéria Pulmonar/diagnóstico por imagem , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Viabilidade , Feminino , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC
3.
Int J Cardiovasc Imaging ; 35(5): 861-868, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30666551

RESUMO

Echocardiographic assessment of diastolic dysfunction depends on surrogate parameters. In recent years, guideline committees attempted to combine these parameters to diagnostic flowcharts allowing for correct classification of left ventricular filling pressures (LVFP). The value of these diagnostic tools is limited if the applied surrogate parameters are elevated due to other reasons as is the case with maximal tricuspid regurgitation velocity. We aimed to compare the accuracy of the 2009 and the 2016 guideline recommendations in patients with pulmonary hypertension (PH). We included 101 consecutive patients who underwent right heart catheterization and transthoracic echocardiography for suspicion of PH. For the final analysis, only patients with PH were considered. The 2009 and 2016 recommendations for the assessment of diastolic function by echocardiography were applied on each patient. A total of 63 PH patients were included in the final analysis, 43% had elevated LVFP. By using the 2009 recommendations, sensitivity for correct classification of diastolic dysfunction was 67%, specificity was 82%, area under the curve (AUC) was 0.74. By using the 2016 recommendations, sensitivity for correct classification of diastolic dysfunction was 84%, specificity was 80%, AUC was 0.82. In ROC comparison, the AUC for the 2016 recommendations with 0.82 was significantly better compared to the AUC of 0.74 for the 2009 recommendations (p = 0.04). Our study demonstrates that the 2016 recommendations for echocardiographic evaluation of diastolic function are superior to the 2009 recommendations in estimating left ventricular filling pressures in patients with PH.


Assuntos
Ecocardiografia Doppler , Hipertensão Pulmonar/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Pressão Ventricular , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo de Swan-Ganz , Diástole , Ecocardiografia Doppler/normas , Feminino , Humanos , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia , Adulto Jovem
4.
Eur Respir J ; 51(5)2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29599186

RESUMO

The commonest cause of pulmonary hypertension (PH) is left heart disease (LHD). The current classification system for definitions of PH-LHD is under review. We therefore performed prospective in-depth invasive haemodynamic phenotyping in order to assess the site of increased pulmonary vascular resistance (PVR) in PH-LHD subsets.Based on pulmonary artery occlusion waveforms yielding an estimate of the effective capillary pressure, we partitioned PVR in larger arterial (Rup, upstream resistance) and small arterial plus venous components (Rds, downstream resistance). In the case of small vessel disease, Rup decreases and Rds increases. Inhaled nitric oxide (NO) testing was used to assess acute vasoreactivity.Right ventricular afterload (PVR, pulmonary arterial compliance and effective arterial elastance) was significantly higher in combined post- and pre-capillary PH (Cpc-PH, n=35) than in isolated post-capillary PH (Ipc-PH, n=20). Right ventricular afterload decreased during inhalation of NO in Cpc-PH and idiopathic pulmonary arterial hypertension (n=31), but remained unchanged in Ipc-PH. Rup was similar in Cpc-PH (66.8±10.8%) and idiopathic pulmonary arterial hypertension (65.0±12.2%; p=0.530) suggesting small vessel disease, but significantly higher in Ipc-PH (96.5±4.5%; p<0.001) suggesting upstream transmission of elevated left atrial pressure.Right ventricular afterload is driven by elevated left atrial pressure in Ipc-PH and is further increased by elevated small vessel resistance in Cpc-PH. Cpc-PH is responsive to inhaled NO. Our data support current definitions of PH-LHD subsets.


Assuntos
Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Artéria Pulmonar/fisiopatologia , Disfunção Ventricular Esquerda/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Pressão Propulsora Pulmonar , Resistência Vascular , Disfunção Ventricular Esquerda/fisiopatologia
5.
Int J Cardiovasc Imaging ; 34(5): 695-700, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29230598

RESUMO

Pulmonary hypertension (PH) is a disease with severe morbidity and mortality. Echocardiography plays an essential role in the screening of PH. The quality of the acquired continuous wave Doppler signal is the major limitation of the method and can greatly affect the accuracy of estimated pulmonary pressures. The aim of this study was to evaluate the clinical need to image from multiple ultrasound windows in patients with suspected pulmonary hypertension. We prospectively evaluated 65 patients (43% male, mean age 67.2 years) with echocardiography and right heart catheterization. 17% had invasively normal pulmonary pressures, 83% had pulmonary hypertension. Peak tricuspid regurgitation (TR) velocity was imaged in five echocardiographic views. Sufficient Doppler signal was recorded in 94% of the patients. Correlation for overall peak TR velocity with invasively measured systolic pulmonary artery pressure was r = 0.83 (p < 0.001). Considering all five imaging windows resulted in a sensitivity of 87%, and a specificity of 91% for correct diagnosis of PH with an AUC of 0.89, which was significantly better as compared to sole imaging from the right ventricular modified apical four-chamber view (AUC 0.85, p = 0.0395). Additional imaging from atypical views changed the overall peak TR velocity in 32% of the patients. A multiple-view approach changed the echocardiographic diagnosis of PH in 11% of the patients as opposed to sole imaging from an apical four-chamber view. This study comprehensively assessed the impact on clinical decision making when evaluating patients with an echocardiographic multiplane approach for suspected PH. This approach substantially increased sensitivity without a decrease in specificity.


Assuntos
Pressão Arterial , Ecocardiografia Doppler/métodos , Hipertensão Pulmonar/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Artéria Pulmonar/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Cateterismo Cardíaco , Feminino , Humanos , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Artéria Pulmonar/fisiopatologia , Curva ROC , Reprodutibilidade dos Testes , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Adulto Jovem
6.
Int J Cardiol ; 224: 440-446, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27710781

RESUMO

BACKGROUND: Although mitral regurgitation (MR) affects a relevant and increasing number of elderly, an optimal management of this high-risk population is challenging. METHODS AND RESULTS: The aim of this prospective, observational study was to compare one-year outcomes of MitraClip therapy in high surgical risk patients with moderate-to-severe or severe MR between patients aged <75 versus ≥75years. A total of 180 patients were included: 92 were <75years and 88 were ≥75years old. At one-year follow-up the primary efficacy endpoint (composite of death, surgery for mitral valve dysfunction and grade 3+ or 4+ MR) occurred in 41 patients (24.5%), with similar rates between those aged <75years (23.9%) and those ≥75years (25.2%), p=0.912. A total of 21 (12.2%) deaths were observed within 1year after the MitraClip procedure, without significant differences in cumulative mortality rates between elderly and younger patients (10.8% vs. 13.3%, respectively, p=0.574). Compared with baseline, the significant reduction in MR severity achieved after the procedure was sustained at one-year follow-up, in both elderly and younger patients and a significant improvement in NYHA functional class was observed in both groups. A total of 18 (10.0%) patients experienced a re-hospitalization for acute heart failure within one-year after the MitraClip procedure, with no significant differences between elderly and younger. At one-year follow-up both elderly and younger patients showed significant reductions in left ventricular volumes, with changes of similar extent between the two subgroups. CONCLUSIONS: MitraClip therapy can be considered a viable option also among subsets with more advanced age.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Complicações Pós-Operatórias , Risco Ajustado/métodos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Ecocardiografia/métodos , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Índice de Gravidade de Doença
7.
Int J Mol Sci ; 17(9)2016 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-27608017

RESUMO

The Ultimaster coronary stent system (Terumo Corporation, Tokyo, Japan) represents a new iteration in drug-eluting stent (DES) technology that has recently received the Conformité Européenne (CE) mark approval for clinical use. The Ultimaster is a thin-strut, cobalt chromium, biodegradable-polymer, sirolimus-eluting coronary stent. The high elasticity of the biodegradable-polymer (PDLLA-PCL) and the abluminal gradient coating technology are additional novel features of this coronary device. The Ultimaster DES has undergone extensive clinical evaluation in two studies: The CENTURY I and II trials. Results from these two landmark studies suggested an excellent efficacy and safety profile of the Ultimaster DES across several lesion and patient subsets, with similar clinical outcomes to contemporary, new-generation DES. The aim of this review is to summarize the rationale behind this novel DES technology and to provide an update of available evidence about the clinical performance of the Ultimaster DES.


Assuntos
Angioplastia com Balão/métodos , Stents Farmacológicos/efeitos adversos , Sirolimo/administração & dosagem , Angioplastia com Balão/efeitos adversos , Plásticos Biodegradáveis/efeitos adversos , Plásticos Biodegradáveis/química , Ensaios Clínicos Fase I como Assunto , Ensaios Clínicos Fase II como Assunto , Humanos
8.
Minerva Cardioangiol ; 64(6): 625-34, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27163247

RESUMO

Upper limb thromboembolism is a relatively uncommon clinical syndrome that mainly affects elderly patients with cardiovascular comorbidities. Atrial fibrillation has been recognized as the main cause. However, many other cardiac and non-cardiac disorders have been identified as possible sources of upper limb thromboemboli. From a clinical point of view, upper limb thromboembolism represents a vascular emergency so that the delay in diagnosis and treatment is highly likely to imply dramatic complications. Therefore, prompt recognition and treatment is mandatory as well as identification and correction of risk factors. Despite its clinical relevance, data in literature are lacking and sparse, most likely because upper limb thromboembolism has a relatively low prevalence in the general population. We sought to write a simple but comprehensive review of this topic, thus proving cardiologists and critical care physicians with the essential tools to recognize and treat upper limb thromboembolism, identifying and correcting also its risk factors and causes.


Assuntos
Isquemia/terapia , Tromboembolia/complicações , Extremidade Superior/irrigação sanguínea , Humanos , Incidência , Isquemia/diagnóstico , Isquemia/epidemiologia , Isquemia/etiologia , Prognóstico , Fluxo Sanguíneo Regional
9.
EuroIntervention ; 11(14): e1649-57, 2016 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-27056125

RESUMO

AIMS: Our aim was to evaluate the impact of baseline chronic kidney disease (CKD) on clinical outcomes after percutaneous edge-to-edge mitral valve repair (PMVR). METHODS AND RESULTS: Two hundred and fourteen consecutive patients dichotomised by the presence of baseline CKD (n=113) or no-CKD (n=101) had their clinical outcomes compared up to 12-month follow-up. The primary safety endpoint was the incidence of major adverse events and the primary efficacy endpoint was freedom from death, surgery for MV dysfunction, or grade ≥3+ MR. The primary safety endpoint was demonstrated in 12.4% vs. 2.0% in CKD and no-CKD patients, respectively (p=0.003). The primary efficacy endpoint at 12 months was significantly lower in CKD patients (65.8% vs. 84.2%, respectively, log-rank p=0.005). While MR reduction and NYHA functional class improvement were mostly sustained and equivalent up to 12 months in no-CKD patients, they were impaired in CKD patients. Baseline CKD was an independent predictor of the primary efficacy endpoint (adjusted HR 2.48, 95% CI: 1.29 to 4.79, p=0.006) and calcified leaflet predicted grade ≥3+ MR at 12 months (adjusted HR 6.56, 95% CI: 2.71 to 15.88, p<0.001). CONCLUSIONS: CKD patients had worse clinical outcomes compared with no-CKD patients post PMVR. CKD was an independent predictor of the primary efficacy endpoint, whereas calcified leaflet was an independent predictor of grade ≥3+ MR at 12 months.


Assuntos
Insuficiência da Valva Mitral/cirurgia , Insuficiência Renal Crônica/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia , Sistema de Registros , Insuficiência Renal Crônica/cirurgia , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
10.
J Cardiovasc Med (Hagerstown) ; 17(11): 843-9, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26258717

RESUMO

AIMS: To appraise the early effect of percutaneous mitral valve repair with the MitraClip system on myocardial function using real-time three-dimensional speckle-tracking echocardiography (3D-STE). METHODS: Consecutive patients with moderate-to-severe or severe mitral regurgitation, undergoing mitral valve repair with the MitraClip system, were prospectively evaluated during the peri-procedural workout and follow-up. Left ventricular deformation was evaluated by a two-dimensional and 3D speckle-tracking analysis. 3D-STE acquisitions were elaborated obtaining real-time 3D global longitudinal strain evaluation, and by appraising both volumetric and hemodynamic parameters (i.e. left ventricular end-diastolic volume, left ventricular end-systolic volume, left ventricular ejection fraction, cardiac output, and stroke volume). RESULTS: In all, 30 patients were included. At 1-month follow-up, 3D-STE analysis revealed no changes in left ventricular end-diastolic volume (162.6 ±â€Š73.7 ml at baseline vs. 159.8 ±â€Š64.5 ml at 1-month follow-up; P = 0.63) and a downward trend in left ventricular end-systolic volume (104.7 ±â€Š52.0 vs. 100.1 ±â€Š50.4 ml, respectively; P = 0.06). Left ventricular ejection fraction did not significantly increase (38.1 ±â€Š11.3% at baseline vs. 39.4 ±â€Š11.0% at 1-month follow-up; P = 0.20). No significant changes were reported in cardiac output (4.3 ±â€Š2.0 l/min at baseline vs. 4.0 ±â€Š1.5 l/min at follow-up; P = 0.377) and in stroke volume (59.5 ±â€Š25.5 ml at baseline vs. 59.9 ±â€Š20.7 ml at follow-up; P = 0.867). On the contrary, left ventricular deformation capability significantly improved, with the real-time 3D global longitudinal strain value changing from -9.8 ±â€Š4.1% at baseline to -11.0 ±â€Š4.4% at follow-up (P = 0.018). CONCLUSIONS: Accurately assessing myocardial function by the use of 3D-STE, this study reported irrelevant early changes in left ventricular size, but a positive effect on left ventricular deformation capability following mitral valve repair with the MitraClip system. These preliminary results need to be confirmed in larger series and extended to long-term follow-up.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Volume Sistólico , Dispositivos de Fixação Cirúrgica/estatística & dados numéricos , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Tridimensional , Feminino , Humanos , Masculino , Resultado do Tratamento
11.
Am J Respir Crit Care Med ; 192(10): 1234-46, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26181215

RESUMO

RATIONALE: Patients with pulmonary hypertension due to left heart disease (PH-LHD) and a diastolic pulmonary vascular pressure gradient ≥ 7 mm Hg, representing PH out of proportion to pulmonary arterial wedge pressure, have pulmonary vascular disease and increased mortality. Little information exists on this condition, recently labeled as "combined pre- and post-capillary PH" (Cpc-PH). OBJECTIVES: To investigate epidemiology, risk factors, right ventricular function, and outcomes in patients with chronic heart failure and Cpc-PH. METHODS: The study population was identified from a retrospective chart review of a clinical database of 3,107 stable patients who underwent first diagnostic right heart catheterization and from a prospective cohort of 800 consecutive patients at a national university-affiliated tertiary center. MEASUREMENTS AND MAIN RESULTS: The retrospective cohort had 664 patients with systolic heart failure (SHF) and 399 patients with diastolic heart failure (DHF), 12% of whom were classified as Cpc-PH. The prospective cohort had 172 patients with SHF (14% Cpc-PH) and 219 patients with DHF (12% Cpc-PH). Chronic obstructive pulmonary disease (P = 0.034) and the tricuspid annular plane systolic excursion to systolic pulmonary artery pressure ratio (P = 0.015) predicted Cpc-PH in SHF. Younger age (P = 0.004), valvular heart disease (P = 0.046), and the tricuspid annular plane systolic excursion to systolic pulmonary artery pressure ratio predicted Cpc-PH in DHF (P = 0.016). Right ventricular-pulmonary vascular coupling was worse in Cpc-PH patients (end-systolic elastance to effective arterial elastance [Ees/Ea]: SHF: 1.05 ± 0.25; P = 0.002; DHF: 1.17 ± 0.27; P = 0.027) than in those with isolated post-capillary PH (Ees/Ea: SHF: 1.52 ± 0.51; DHF: 1.45 ± 0.29). CONCLUSIONS: Cpc-PH is rare in chronic heart failure. Right ventricular-pulmonary vascular coupling is poor in Cpc-PH and could be one explanation for dismal outcomes.


Assuntos
Insuficiência Cardíaca/epidemiologia , Hipertensão Pulmonar/epidemiologia , Doença Cardiopulmonar/epidemiologia , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Direita/epidemiologia , Idoso , Análise de Variância , Áustria/epidemiologia , Comorbidade , Atestado de Óbito , Feminino , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica/fisiologia , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Estudos Prospectivos , Doença Cardiopulmonar/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Distribuição por Sexo , Análise de Sobrevida , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/fisiopatologia
13.
Catheter Cardiovasc Interv ; 85(5): 889-97, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25367550

RESUMO

OBJECTIVES: To assess the influence of patients' gender on the outcomes of percutaneous edge-to-edge mitral valve repair (PMVR) using the MitraClip system. BACKGROUND: Although gender-related differences have been extensively documented in patients who undergo surgery for moderate-to-severe (3+) and severe (4+) mitral regurgitation (MR), studies assessing whether these differences exist after PMVR are lacking. METHODS: Clinical and echocardiographic data through 12-month follow up from 171 consecutive patients whom underwent MitraClip implantation and were dichotomized by the gender (106 males and 65 females) were obtained. The primary safety endpoint was the incidence of major adverse events at 30 days and the primary efficacy endpoint was freedom from death, surgery for mitral valve dysfunction, or grade≥3+ MR at 12-month follow up. RESULTS: The primary safety endpoint was observed in four males (3.8%) and four females (6.2%) (P=0.358). Remarkable reduction in MR postprocedure was revealed in both groups, and these results were mostly sustained. Furthermore, left ventricle reverse remodeling and New York Heart Association (NYHA) functional class improvement were revealed in both groups, but females tended to demonstrate worse results over time (P=0.083). The primary efficacy endpoint obtained by Kaplan-Meier estimates was observed in 76.3 and 70.2%, respectively (log rank P=0.231). CONCLUSIONS: MitraClip implantation in patients with 3+ and 4+ MR is safe and efficacious until mid-term follow up, regardless of patients' gender. Despite improvement in NYHA functional class in both groups, female gender demonstrated a trend toward poorer results. Further validation of our findings is warranted.


Assuntos
Ecocardiografia , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Idoso , Feminino , Seguimentos , Humanos , Incidência , Itália/epidemiologia , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Desenho de Prótese , Fatores Sexuais , Fatores de Tempo
14.
JACC Cardiovasc Interv ; 8(1 Pt A): 74-82, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25499300

RESUMO

OBJECTIVES: This study sought to compare, in high-risk patients with 3+ to 4+ mitral regurgitation (MR) dichotomized by baseline echocardiographic features, acute, 30-day, and 12-month outcomes following percutaneous mitral valve repair using the MitraClip. BACKGROUND: The feasibility and mid-term outcomes after MitraClip implantation in patients with echocardiographic features different from the EVEREST (Endovascular Valve Edge-to-Edge Repair) I and II trials have been scarcely studied. METHODS: Clinical and echocardiographic outcomes through 12-month follow-up of consecutive patients who underwent MitraClip implantation were obtained from an ongoing prospective registry. Two different groups, divided according to baseline echocardiographic criteria (investigational group [EVERESTOFF] and control group [EVERESTON]), were compared. RESULTS: Seventy-eight patients were included in EVERESTOFF and 93 patients in EVERESTON groups. Important and comparable acute reductions in MR and no clip-related complications were revealed. The primary safety endpoint at 30 days was comparable between groups (2.6% vs. 6.5%, respectively, p = 0.204); in addition, MR reduction was mostly sustained, whereas equivalent improvement in New York Heart Association functional class were demonstrated. Kaplan-Meier freedom from death, surgery for mitral valve dysfunction, or grade ≥3+ MR at 12 months was demonstrated in 71.4% and 76.2%, respectively, in the EVERESTOFF and EVERESTON groups (log rank p = 0.378). Significant improvements in ejection fraction and reduction in left ventricle volumes were demonstrated in both groups over time, but the baseline between-group differences were sustained. CONCLUSIONS: MitraClip implantation in patients with expanded baseline echocardiographic features, compared with the control group, was associated with similar rates of safety and efficacy through 12-month follow-up. Further validation of our findings is warranted.


Assuntos
Procedimentos Cirúrgicos Cardíacos/instrumentação , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Estudos de Casos e Controles , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia , Função Ventricular Esquerda
16.
Eur Heart J Cardiovasc Imaging ; 15(11): 1246-55, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24939944

RESUMO

AIM: The aim of this study was to evaluate the association of baseline tricuspid regurgitation (TR) on the outcomes after percutaneous mitral valve repair (PMVR) with the MitraClip system. METHODS AND RESULTS: Data from 146 consecutive patients with functional mitral regurgitation (MR) were obtained. Two different groups, dichotomized according to the degree of pre-procedural TR (moderate/severe, n = 47 and none/mild, n = 99), had their clinical and echocardiographic outcomes through 12-month compared. At 30-day, the primary safety endpoint was significantly higher in moderate/severe TR compared with none/mild TR (10.6 vs. 2.0%, P = 0.035). Marked reduction in MR grades observed post-procedure were maintained through 12 months. Although NYHA functional class significantly improved in both groups compared with baseline, it was impaired in moderate/severe TR compared with the none/mild TR group (NYHA > II at 30 day: 33.3 vs. 9.2%, P < 0.001; at 1 year: 38.5 vs. 12.3%, respectively, P = 0.006). Left ventricle reverse remodelling and ejection fraction improvement were revealed in both groups. The primary efficacy endpoint at 12-month determined by freedom from death, surgery for mitral valve dysfunction, or grade ≥ 3+ MR was comparable between groups, but combined death and re-hospitalization for heart failure rates were higher in the moderate/severe TR group. Multivariable Cox regression analysis demonstrated that baseline moderate/severe TR and chronic kidney disease were independent predictors of this combined endpoint. CONCLUSIONS: Although PMVR with MitraClip led to improvement in MR, TR, and NYHA functional class in patients with baseline moderate/severe TR, the primary safety endpoint at 30-day was impaired, while moderate/severe TR independently predicted death and re-hospitalization for heart failure at 12-month.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Idoso , Comorbidade , Ecocardiografia , Determinação de Ponto Final , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Insuficiência da Valva Mitral/mortalidade , Readmissão do Paciente/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência da Valva Tricúspide/mortalidade
18.
Am J Cardiol ; 111(10): 1482-7, 2013 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-23433761

RESUMO

The aim of this study was to report on the 30-day and 1-year outcomes of percutaneous mitral valve repair with the MitraClip technique in patients with grade ≥3+ mitral regurgitation (MR) at high risk for conventional surgical therapy enrolled in the prospective Getting Reduction of Mitral Insufficiency by Percutaneous Clip Implantation (GRASP) registry. Acute device success was defined as residual MR ≤2+ after clip implantation. The primary safety end point was the rate of major adverse events at 30 days. The primary efficacy end point was freedom from death, surgery for mitral valve dysfunction, or grade ≥3+ MR at 30 days and 1 year. A total of 117 patients were treated. Eighty-nine patients (76%) presented with functional MR and 28 patients (24%) with organic MR. Acute device success was observed in all patients. Device implantation time significantly diminished with experience and varied significantly between cases with 1 versus ≥2 clips. No procedural mortality was recorded. Major adverse events occurred in 4 patients at 30 days (4.3%). Deterioration to MR ≥3+ was recorded in 25% of patients with degenerative MR and 7% of those with functional MR at 1 year. No surgery for mitral valve dysfunction occurred within 1 year. Freedom from death, surgery for mitral valve dysfunction, or grade ≥3+ MR was 96.4% and 75.8% at 30 days and 1 year, respectively. No significant differences were noted in the primary efficacy end point between patients with degenerative MR and those with functional MR. In conclusion, percutaneous mitral valve repair with the MitraClip technique was shown to be safe and reasonably effective in 117 patients from a real-world setting.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Ecocardiografia , Feminino , Seguimentos , Humanos , Itália/epidemiologia , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/mortalidade , Estudos Prospectivos , Desenho de Prótese , Segurança , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
19.
J Am Soc Echocardiogr ; 25(10): 1099-105, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22898243

RESUMO

BACKGROUND: Successful mitral valve surgical repair, decreasing volume overload, has been shown to provide reverse left ventricular (LV) and/or left atrial remodeling in most patients. Percutaneous mitral valve repair with the MitraClip system (Abbott, Abbott Park, IL) has been associated with favorable clinical outcomes in patients with mitral regurgitation at high risk of surgery. However, specific data on left cardiac chambers reverse remodeling after such procedures are limited. METHODS: This was a prospective observational study of consecutive patients at high risk of surgery, with moderate-to-severe or severe mitral regurgitation undergoing MitraClip system implantation. Follow-up echocardiography was performed at 6 months. The evaluated parameters were the LV end-diastolic and end-systolic volume indexes, LV sphericity index, LV ejection fraction, and left atrial volume index. Reverse LV remodeling was defined as a decrease of 10% in the LV end-diastolic volume index. RESULTS: The study population included 44 patients: 14 with degenerative and 30 with functional mitral regurgitation. At 6 months of follow-up, significant reductions in the median and interquartile range of the sphericity index (from 0.57 [interquartile range 0.54-0.62] to 0.54 [interquartile range 0.50-0.58]; P < .001), LV end-diastolic volume index (from 79.4 mL/m(2) [interquartile range 63.0-102.2] to 60.7 mL/m(2) [50.8-84.4]; P < .001), and LV end-systolic volume index (from 49.3 mL/m(2) [interquartile range 28.2-70.5] to 28.9 mL/m(2) [interquartile range 22.2-55.8]; P < .001) were observed. The LV ejection fraction improved significantly (from 38.0% [interquartile range 30.0-55.0%] to 46.0% [interquartile range 35.0-58.0%]; P < .001) from baseline to 6 months. Minor differences in the left atrial volume index were observed. Reverse remodeling, according to the specified definition, was observed in 77.3% of the patients. CONCLUSIONS: The present study reports positive LV reshape effects after mitral valve repair with the MitraClip system, showing significant improvements in LV size and function.


Assuntos
Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Dispositivo para Oclusão Septal , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/prevenção & controle , Idoso , Feminino , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Resultado do Tratamento , Ultrassonografia , Disfunção Ventricular Esquerda/etiologia , Remodelação Ventricular
20.
Am Heart J ; 163(4): 684-9, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22520535

RESUMO

BACKGROUND: Multislice computed tomography (MSCT) has generally been accepted as the most accurate modality fulfilling this purpose with good reproducibility. A major drawback of MSCT consists in the use of contrast dye, which may be unsafe in transcatheter aortic valve implantation (TAVI) patients who frequently are affected by renal failure. We sought to appraise the accuracy of intracardiac echocardiography (ICE) in measurements of structures in the aortic root in patients undergoing TAVI. METHODS: Aortic annulus and sinus of Valsalva diameters were measured using ICE, performed during standard invasive preprocedural assessment in 30 consecutive patients with severe aortic stenosis referred for TAVI. Multislice computed tomography was performed in all patients afterward, and aortic root measurements were made by an independent radiologist. RESULTS: Effective ICE measurements were obtained in all patients, easily and without any complication. Mean aortic annulus diameters were 21.9 ± 1.8 mm using ICE, 22.0 ± 1.9 mm using MSCT (3-chamber [3-C] view) and 22.8 ± 1.8 mm using the mean of long-axis and short-axis (L-ax/S-ax) view MSCT (P = .192, ICE vs 3-C MSCT; P < .001, ICE vs L-ax/S-ax MSCT, respectively). Correlation between ICE and both MSCT measurements was good (r(2) = 0.83, P < .001; r(2) = 0.80, P < .001, respectively). Mean sinus of Valsalva diameters were 32.3 ± 3.3 mm using ICE and 32.5 ± 3.1 mm using 3-C MSCT view (P = .141). Even in this case, correlation between ICE and both MSCT measurements was excellent (r(2) = 0.96, P < .001). CONCLUSIONS: In patients referred for TAVI, measurements of the aortic annulus and the sinus of Valsalva using ICE compare favorably with those made at MSCT. This approach might be a useful and reproducible strategy in patients with severe renal impairment to avoid the administration of contrast dye during MSCT.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Seio Aórtico/diagnóstico por imagem , Ultrassonografia de Intervenção , Adulto , Ecocardiografia/métodos , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...