Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Food Chem ; 241: 122-126, 2018 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-28958508

RESUMO

This paper describes the development of a simple, low cost chronoamperometric assay, for the measurement of fructose, using a graphite-nanoparticle modified screen-printed electrode (SPCE-G-COOH). Cyclic voltammetry showed that the response of the SPCE-G-COOH enhanced the sensitivity and precision, towards the enzymatically generated ferrocyanide species, over a plain SPCE; therefore the former was employed in subsequent studies. Calibration studies were carried out using chronoamperometry with a 40µl mixture containing fructose, mediator and FDH, deposited onto the SPCE-G-COOH. The response was linear from 0.1mM to 1.0mM. A commercial fruit juice sample was analysed using the developed assay and the fructose concentration was calculated to be 477mM with a precision of 3.03% (n=5). Following fortification (477mM fructose) the mean recovery was found to be 97.12% with a coefficient of variation of 6.42% (n=5); consequently, the method holds promise for the analysis of commercial fruit juices.


Assuntos
Frutose/análise , Carbono , Eletrodos , Grafite , Nanopartículas
2.
Sensors (Basel) ; 14(11): 20519-32, 2014 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-25360580

RESUMO

This report describes the design and development of an integrated electrochemical cell culture monitoring system, based on enzyme-biosensors and chemical sensors, for monitoring indicators of mammalian cell metabolic status. MEMS technology was used to fabricate a microwell-format silicon platform including a thermometer, onto which chemical sensors (pH, O2) and screen-printed biosensors (glucose, lactate), were grafted/deposited. Microwells were formed over the fabricated sensors to give 5-well sensor strips which were interfaced with a multipotentiostat via a bespoke connector box interface. The operation of each sensor/biosensor type was examined individually, and examples of operating devices in five microwells in parallel, in either potentiometric (pH sensing) or amperometric (glucose biosensing) mode are shown. The performance characteristics of the sensors/biosensors indicate that the system could readily be applied to cell culture/toxicity studies.


Assuntos
Técnicas Biossensoriais/instrumentação , Glucose/análise , Neoplasias Experimentais/química , Neoplasias Experimentais/metabolismo , Oximetria/instrumentação , Termografia/instrumentação , Análise Serial de Tecidos/instrumentação , Linhagem Celular Tumoral , Desenho Assistido por Computador , Condutometria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Concentração de Íons de Hidrogênio , Ácido Láctico/metabolismo , Sistemas Microeletromecânicos/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Integração de Sistemas , Temperatura
3.
Anal Biochem ; 347(1): 17-23, 2005 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-16266677

RESUMO

This paper describes the optimisation of a screen-printing water-based carbon ink containing cobalt phthalocyanine (CoPC) and glucose oxidase (GOD) for the fabrication of a glucose biosensor. To optimise the performance of the biosensor, the loadings of the electrocatalyst (CoPC) and enzyme (GOD) were varied. It was found that the maximum linear range was achieved with a CoPC loading of 20% (m/m, relative to the mass of carbon) and a GOD loading of 628 U per gram of carbon. In our studies we chose to employ chronoamperometry, as this technique is commonly used for commercial devices. The optimum operating applied potential was found to be +0.5 V, following an incubation period of 60 s. The optimum supporting electrolyte was found to be 0.05 M phosphate buffer at pH 8.0, which resulted in a linear range of 0.2-5 mM, the former represents the detection limit. The sensitivity was 1.12 microA mM(-1). The effect of temperature was also investigated, and it was found that 40 degrees C gave optimal performance. The resulting amperometric biosensors were evaluated by measuring the glucose concentrations for 10 different human plasma samples containing endogenous glucose and also added glucose. The same samples were analysed by a standard spectrophotometric method, and the results obtained by the two different methods were compared. A good correlation coefficient (R(2) = 0.95) and slope (0.98) were calculated from the experimental data, indicating that the new devices hold promise for biomedical studies.


Assuntos
Técnicas Biossensoriais , Glicemia/análise , Carbono/química , Glucose Oxidase/química , Tinta , Catálise , Humanos , Concentração de Íons de Hidrogênio , Indóis/química , Compostos Organometálicos/química , Potenciometria/métodos , Soro/química , Temperatura , Água/química
4.
Biosens Bioelectron ; 21(5): 712-8, 2005 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-16242609

RESUMO

Screen-printed amperometric glucose biosensors have been fabricated using a water-based carbon ink. The enzyme glucose oxidase (GOD) and the electro-catalyst cobalt phthalocyanine were mixed with the carbon ink prior to the screen-printing process; therefore, biosensors are prepared in a one-step fabrication procedure. Optimisation of the biosensor performance was achieved by studying the effects of pH, buffer strength, and applied potential on the analytical response. Calibration studies were performed under optimum conditions, using amperometry in stirred solution, with an operating potential of +500 mV versus SCE. The sensitivity was found to be 1170 nA mM(-1), with a linear range of 0.025-2 mM; the former represents the detection limit. The disposable amperometric biosensor was evaluated by carrying out replicate determinations on a sample of bovine serum. This was achieved by the method of multiple standard additions and included a correction for background currents arising from oxidizable serum components. The mean serum concentration was calculated to be 8.63 mM and compared well with the supplier's value of 8.3 mM; the coefficient of variation was calculated to be 3.3% (n=6).


Assuntos
Técnicas Biossensoriais/instrumentação , Automonitorização da Glicemia/instrumentação , Glicemia/análise , Carbono/química , Eletroquímica/instrumentação , Glucose Oxidase/química , Tinta , Água/química , Técnicas Biossensoriais/métodos , Automonitorização da Glicemia/métodos , Equipamentos Descartáveis , Eletroquímica/métodos , Enzimas Imobilizadas/química , Desenho de Equipamento , Análise de Falha de Equipamento , Impressão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...