Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Biol ; 21(1): 126, 2023 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-37280616

RESUMO

BACKGROUND: The development of nanoscale secondary ion mass spectrometry (NanoSIMS) has revolutionized the study of biological tissues by enabling, e.g., the visualization and quantification of metabolic processes at subcellular length scales. However, the associated sample preparation methods all result in some degree of tissue morphology distortion and loss of soluble compounds. To overcome these limitations an entirely cryogenic sample preparation and imaging workflow is required. RESULTS: Here, we report the development of a CryoNanoSIMS instrument that can perform isotope imaging of both positive and negative secondary ions from flat block-face surfaces of vitrified biological tissues with a mass- and image resolution comparable to that of a conventional NanoSIMS. This capability is illustrated with nitrogen isotope as well as trace element mapping of freshwater hydrozoan Green Hydra tissue following uptake of 15N-enriched ammonium. CONCLUSION: With a cryo-workflow that includes vitrification by high pressure freezing, cryo-planing of the sample surface, and cryo-SEM imaging, the CryoNanoSIMS enables correlative ultrastructure and isotopic or elemental imaging of biological tissues in their most pristine post-mortem state. This opens new horizons in the study of fundamental processes at the tissue- and (sub)cellular level. TEASER: CryoNanoSIMS: subcellular mapping of chemical and isotopic compositions of biological tissues in their most pristine post-mortem state.


Assuntos
Microscopia Crioeletrônica , Microscopia Eletrônica de Varredura
2.
Chimia (Aarau) ; 76(1-2): 26-33, 2022 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38069746

RESUMO

Secondary Ion Mass Spectrometry (SIMS) extracts chemical, elemental, or isotopic information about a localized area of a solid target by performing mass spectrometry on secondary ions sputtered from its surface by the impact of a beam of charged particles. This primary beam sputters ionized atoms and small molecules (as well as many neutral particles) from the upper few nanometers of the sample surface. The physical basis of SIMS has been applied to a large range of applications utilizing instruments optimized with different types of mass analyzer, either dynamic SIMS with a double focusing mass spectrometer or static SIMS with a Time of Flight (TOF) analyzer. Here, we present a short review of the principles and major applications of three different SIMS instruments located in Switzerland.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...