Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Oper Dent ; 48(5): E119-E136, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37655625

RESUMO

OBJECTIVE: This study compares the physical properties and clinical performance of short fiber reinforced composites (SFRC) to those of particulate-filled resin-based composites (PFRC) for class I and II direct restorations in permanent dentition. METHODS: Systematic review and meta-analysis was conducted using PubMed, Embase (Elsevier), and Dentistry and Oral Sciences Source (EBSCO) databases. The outcomes evaluated were physical properties including flexural strength, flexural modulus, elastic modulus, microhardness, shrinkage, fracture toughness, degree of conversion, and depth of cure. Clinical performance was evaluated with a systematic review. RESULTS: The meta-analyses favored SFRC for flexural strength and fracture toughness compared to every PFRC subgroup, with a high quality of evidence. For all other properties, the meta-analyses favored SFRC to overall PFRC, with some non-significant differences with certain PFRC subgroups. The most recent clinical trial showed SFRC performed similarly to PFRC, however older studies suggest inferior surface texture and discoloration of SFRC compared to PFRC. CONCLUSION: This study can aid dental professionals in clinical decision making, supporting that SFRC offers improved physical properties, especially fracture resistance and flexural strength, compared to PFRC.


Assuntos
Materiais Dentários , Dentição , Módulo de Elasticidade , Resistência à Flexão
2.
Oper Dent ; 44(3): E133-E144, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30849014

RESUMO

OBJECTIVES: To investigate the influence of curing distance on the degree of conversion (DC) of a resin-based composite (RBC) when similar radiant exposure was achieved using six different light-curing units (LCUs) and to explore the correlation among irradiance, radiant exposure, and DC. METHODS AND MATERIALS: A managing accurate resin curing-resin calibrator system was used to collect irradiance data for both top and bottom specimen surfaces with a curing distance of 2 mm and 8 mm while targeting a consistent top surface radiant exposure. Square nanohybrid-dual-photoinitiator RBC specimens (5 × 5 × 2 mm) were cured at each distance (n=6/LCU/distance). Irradiance and DC (micro-Raman spectroscopy) were determined for the top and bottom surfaces. The effect of distance and LCU on irradiance, radiant exposure, and DC as well as their linear associations were analyzed using analysis of variance and Pearson correlation coefficients, respectively (α=0.05). RESULTS: While maintaining a similar radiant exposure, each LCU exhibited distinctive patterns in decreased irradiance and increased curing time. No significant differences in DC values (63.21%-70.28%) were observed between the 2- and 8-mm distances, except for a multiple-emission peak LCU. Significant differences in DC were detected among the LCUs. As expected, irradiance and radiant exposure were significantly lower on the bottom surfaces. However, a strong correlation between irradiance and radiant exposure did not necessarily result in a strong correlation with DC. CONCLUSIONS: The RBC exhibited DC values >63% when the top surface radiant exposure was maintained, although the same values were not reached for all lights. A moderate-strong correlation existed among irradiance, radiant exposure, and DC.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Materiais Dentários , Teste de Materiais
3.
Oper Dent ; 44(1): E32-E44, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29856698

RESUMO

OBJECTIVES:: To evaluate 1) the internal adaptation of a light-activated incremental-fill and bulk-fill resin-based composite (RBC) materials by measuring the gap between the restorative material and the tooth structure and 2) the aging effect on internal adaptation. METHODS AND MATERIALS:: Seventy teeth with class I cavity preparations were randomly distributed into five groups; four groups were restored with bulk-fill RBCs: Tetric EvoCeram Bulk Fill (TEC), SonicFill (SF), QuiXX Posterior Restorative (QX), and X-tra fil (XF); the fifth group was restored with incremental-fill Filtek Supreme Ultra Universal Restorative (FSU). One-half of the specimens of each group were thermocycled. Each tooth was sectioned, digital images were recorded, and the dimensions of any existing gaps were measured. Data were analyzed using analysis of variance (α=0.05). RESULTS:: FSU had the smallest gap measurement values compared with the bulk-fill materials except QX and TEC ( p≤0.008). FSU had the smallest sum of all gap category values compared with the bulk-fill materials, except QX ( p≤0.021). The highest gap incidence and size values were found at the composite/adhesive interface. All aged groups had greater gap values in regard to the gap measurement and the sum of all gap categories compared with non-aged groups. SIGNIFICANCE:: The incrementally placed material FSU had the highest internal adaptation to the cavity surface, while the four bulk-fill materials showed varied results. Thermocycling influenced the existing gap area magnitudes. The findings suggest that the incremental-fill technique produces better internal adaptation than the bulk-fill technique.


Assuntos
Resinas Compostas/química , Adaptação Marginal Dentária , Restauração Dentária Permanente/métodos , Materiais Dentários/química , Humanos , Técnicas In Vitro , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Metacrilatos , Dente Molar , Propriedades de Superfície
5.
Oper Dent ; 43(1): E1-E9, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29284100

RESUMO

The present study investigated the effect of three high-viscosity bulk-fill resin-based composite materials on cuspal deflection in natural teeth. Thirty-two sound maxillary premolar teeth with large slot mesio-occlusal-distal cavities were distributed into four groups (n=8). Three groups were restored with bulk-fill resin composite materials (Tetric EvoCeram Bulk Fill, Ivoclar Vivadent, Schaan, Liechtenstein; x-tra fil, VOCO, Cuxhaven, Germany; and SonicFill, Kerr, Orange, CA, USA) in a single 4-mm increment. The conventional composite group, Filtek Z100 (3M ESPE, St Paul, MN, USA), was used to restore the cavities in 2-mm increments. Cusp deflection was recorded postirradiation using a Nikon measurescope UM-2 (Nikon, Tokyo, Japan) by measuring the changes in the bucco-palatal widths of the teeth at five minutes, 24 hours, and 48 hours after completion of the restorations. Cuspal deflection was significantly higher in the conventional composite than in the Tetric EvoCeram Bulk Fill ( p=0.0031), x-tra fil ( p=0.0029), and SonicFill Bulk ( p=0.0002) groups. There were no significant differences in cuspal deflection among the three bulk-fill materials (all p<0.05). In conclusion, all the investigated bulk-fill resin composites exhibited cuspal deflection values that were smaller than those associated with a conventional incrementally placed resin composite.


Assuntos
Dente Pré-Molar/cirurgia , Resinas Compostas/uso terapêutico , Restauração Dentária Permanente/efeitos adversos , Resinas Compostas/efeitos adversos , Cárie Dentária/cirurgia , Restauração Dentária Permanente/métodos , Humanos , Polimerização , Ceras/efeitos adversos , Ceras/uso terapêutico
6.
Oper Dent ; 41(1): 1, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26779674
7.
Odontology ; 104(2): 170-5, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-25556157

RESUMO

This study aimed to compare the effect of two concentrations of triple antibiotic paste (TAP) with or without ethylenediaminetetraacetic acid (EDTA) on surface loss and surface roughness of radicular dentine. Human radicular dentine specimens were randomized into six experimental groups (n = 16 per group). The first and second groups were treated with 1,000 mg/mL or 1 mg/mL of TAP for 4 weeks. The third and fourth groups were treated with 1,000 mg/mL or 1 mg/mL of TAP for 4 weeks followed by 17 % EDTA for 5 min. The fifth group was treated with 17 % EDTA for 5 min and the sixth group received no treatment (control). Dentine surface loss and surface roughness were quantified after various treatments using optical and contact profilometry, respectively. One-way ANOVA followed by Fisher's protected least significant differences was used for statistical analyses. All treatment groups showed significantly higher surface loss compared to the untreated dentine. Dentine treated with 1,000 mg/mL had significant increase in surface loss and surface roughness compared to dentine treated with 1 mg/mL of TAP. The use of EDTA after both concentrations of TAP did not have significant additive effect on surface loss and surface roughness of dentine. The clinically used concentration of TAP (1,000 mg/mL) caused significantly higher surface loss and surface roughness of radicular dentine compared to the use of 1 mg/mL of TAP. Furthermore, the substantial amount of dentine surface loss and surface roughness detected in the current study may be attributed to TAP rather than EDTA.


Assuntos
Antibacterianos/farmacologia , Dentina/efeitos dos fármacos , Ácido Edético/farmacologia , Humanos , Pomadas , Distribuição Aleatória , Propriedades de Superfície , Raiz Dentária/efeitos dos fármacos
8.
Oper Dent ; 40(6): 563, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26606314
9.
Oper Dent ; 40(4): E158-66, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25764042

RESUMO

The purpose of this study was to evaluate the influence of direct base and indirect inlay materials on stress distribution and fracture resistance of endodontically treated premolars with weakened cusps. Forty healthy human premolars were selected; five were left intact as controls (group C+), and the others were subjected to endodontic treatment and removal of buccal and lingual cusp dentin. Five teeth were left as negative controls (group C-). The remaining 30 teeth were divided into two groups according to the direct base material (glass ionomer [GIC] or composite resin [CR]). After base placement, each group was subjected to extensive inlay preparation, and then three subgroups were created (n=5): no inlay restoration (GIC and CR), restored with an indirect composite resin inlay (GIC+IR and CR+IR), and restored with a ceramic inlay (GIC+C and CR+C). Each specimen was loaded until fracture in a universal testing machine. For finite element analysis, the results showed that the removal of tooth structure significantly affected fracture resistance. The lowest values were presented by the negative control group, followed by the restored and based groups (not statistically different from each other) and all lower than the positive control group. In finite element analysis, the stress concentration was lower in the restored tooth compared to the tooth without restoration, whereas in the restored teeth, the stress concentration was similar, regardless of the material used for the base or restoration. It can be concluded that the inlay materials combined with a base showed similar behavior and were not able to regain the strength of intact tooth structure.


Assuntos
Dente Pré-Molar , Materiais Dentários , Análise do Estresse Dentário , Fraturas dos Dentes/prevenção & controle , Dente Pré-Molar/lesões , Dente Pré-Molar/fisiologia , Preparo da Cavidade Dentária , Restauração Dentária Permanente , Análise de Elementos Finitos , Humanos , Técnicas In Vitro , Teste de Materiais , Resistência à Tração , Preparo Prostodôntico do Dente
10.
Oper Dent ; 40(1): 87-95, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-24809538

RESUMO

OBJECTIVE: We examined the influence of light intensity on surface free energy characteristics and dentin bond strength of dual-cure direct core build-up resin systems. METHODS: Two commercially available dual-cure direct core build-up resin systems, Clearfil DC Core Automix with Clearfil Bond SE One and UniFil Core EM with Self-Etching Bond, were studied. Bovine mandibular incisors were mounted in acrylic resin and the facial dentin surfaces were wet ground on 600-grit silicon carbide paper. Adhesives were applied to dentin surfaces and cured with light intensities of 0 (no irradiation), 200, 400, and 600 mW/cm(2). The surface free energy of the adhesives (five samples per group) was determined by measuring the contact angles of three test liquids placed on the cured adhesives. To determine the strength of the dentin bond, the core build-up resin pastes were condensed into the mold on the adhesive-treated dentin surfaces according to the methods described for the surface free energy measurement. The resin pastes were cured with the same light intensities as those used for the adhesives. Ten specimens per group were stored in water maintained at 37°C for 24 hours, after which they were shear tested at a crosshead speed of 1.0 mm/minute in a universal testing machine. Two-way analysis of variance (ANOVA) and a Tukey-Kramer test were performed, with the significance level set at 0.05. RESULTS: The surface free energies of the adhesive-treated dentin surfaces decreased with an increase in the light intensity of the curing unit. Two-way ANOVA revealed that the type of core build-up system and the light intensity significantly influence the bond strength, although there was no significant interaction between the two factors. The highest bond strengths were achieved when the resin pastes were cured with the strongest light intensity for all the core build-up systems. When polymerized with a light intensity of 200 mW/cm(2) or less, significantly lower bond strengths were observed. CONClUSIONS: The data suggest that the dentin bond strength of core build-up systems are still affected by the light intensity of the curing unit, which is based on the surface free energy of the adhesives. On the basis of the results and limitations of the test conditions used in this study, it appears that a light intensity of >400 mW/cm(2) may be required for achieving the optimal dentin bond strength.


Assuntos
Adesivos Dentinários/efeitos da radiação , Luz , Resinas Sintéticas/efeitos da radiação , Animais , Bovinos , Resinas Compostas/efeitos da radiação , Resinas Compostas/uso terapêutico , Lâmpadas de Polimerização Dentária , Colagem Dentária/métodos , Análise do Estresse Dentário , Dentina/ultraestrutura , Adesivos Dentinários/uso terapêutico , Microscopia Eletrônica de Varredura , Cimentos de Resina/efeitos da radiação , Cimentos de Resina/uso terapêutico , Resinas Sintéticas/uso terapêutico , Propriedades de Superfície
11.
Oper Dent ; 40(2): 201-10, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25268039

RESUMO

This study assessed marginal leakage and fracture resistance of computer-aided design/computer-aided manufacturing (CAD/CAM) fabricated ceramic crowns with intracoronal extensions into the pulp chambers of endodontically treated teeth (endocrowns) using either feldspathic porcelain (CEREC Blocks [CB], Sirona Dental Systems GmbH, Bensheim, Germany), lithium disilicate (e.max [EX], Ivoclar Vivadent, Schaan, Liechtenstein), or resin nanoceramic (Lava Ultimate [LU], 3M ESPE, St Paul, MN, USA).). Thirty extracted human permanent maxillary molars were endodontically treated. Standardized preparations were done with 2-mm intracoronal extensions of the endocrowns into the pulp chamber. Teeth were divided into three groups (n=10); each group was restored with standardized CAD/CAM fabricated endocrowns using one of the three tested materials. After cementation with resin cement, specimens were stored in distilled water at 37°C for one week, subjected to thermocycling, and immersed in a 5% methylene-blue dye solution for 24 hours. A compressive load was applied at 35 degrees to long axis of the teeth using a universal testing machine until failure. Failure load was recorded, and specimens were examined under a stereomicroscope for modes of failure and microleakage. Results were analyzed using one-way analysis of variance and Bonferroni post hoc multiple comparison tests (α=0.05). LU showed significantly (p<0.05) higher fracture resistance and more favorable fracture mode (ie, fracture of the endocrown without fracture of tooth) as well as higher dye penetration than CB and EX. In conclusion, although using resin nanoceramic blocks for fabrication of endocrowns may result in better fracture resistance and a more favorable fracture mode than other investigated ceramic blocks, more microleakage may be expected with this material.


Assuntos
Coroas , Infiltração Dentária/etiologia , Planejamento de Prótese Dentária/métodos , Falha de Restauração Dentária , Cerâmica/uso terapêutico , Desenho Assistido por Computador , Coroas/efeitos adversos , Porcelana Dentária/uso terapêutico , Planejamento de Prótese Dentária/efeitos adversos , Análise do Estresse Dentário , Humanos , Cimentos de Resina/uso terapêutico
12.
J Dent Res ; 93(11): 1070-5, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25248613

RESUMO

Although there is strong evidence for the effectiveness of sealants, one major barrier in sealant utilization is the concern of sealing over active caries lesions. This study evaluated detection and monitoring of caries lesions through a clear sealant over 44 mo. Sixty-four 7- to 10-year-old children with at least 2 permanent molars with International Caries Detection and Assessment System (ICDAS) scores 0-4 (and caries less than halfway through the dentin, radiographically) were examined with ICDAS, DIAGNOdent, and quantitative light-induced fluorescence (QLF) before sealant placement and 1, 12, 24, and 44 mo (except QLF) after. Bitewing radiographs were taken yearly. DIAGNOdent and QLF were able to distinguish between baseline ICDAS before and after sealant placement. There was no significant evidence of ICDAS progression at 12 mo, but there was small evidence of minor increases at 24 and 44 mo (14% and 14%, respectively) with only 2% ICDAS ≥ 5. Additionally, there was little evidence of radiographic progression (at 12 mo = 1%, 24 mo = 3%, and 44 mo = 9%). Sealant retention rates were excellent at 12 mo = 89%, 24 mo = 78%, and 44 mo = 70%. The small risk of sealant repair increased significantly as baseline ICDAS, DIAGNOdent, and QLF values increased. However, regardless of lesion severity, sealants were 100% effective at 12 mo and 98% effective over 44 mo in managing occlusal surfaces at ICDAS 0-4 (i.e., only 4 of 228 teeth progressed to ICDAS ≥ 5 associated with sealants in need of repair and none to halfway or more through the dentin, radiographically). This study suggests that occlusal surfaces without frank cavitation (ICDAS 0-4) that are sealed with a clear sealant can be monitored with ICDAS, QLF, or DIAGNOdent, which may aid in predicting the need for sealant repair.


Assuntos
Cárie Dentária/terapia , Esmalte Dentário/patologia , Selantes de Fossas e Fissuras/uso terapêutico , Criança , Índice CPO , Colagem Dentária , Cárie Dentária/diagnóstico , Dentina/patologia , Progressão da Doença , Feminino , Fluorescência , Seguimentos , Humanos , Lasers , Estudos Longitudinais , Masculino , Dente Molar/patologia , Radiografia Interproximal , Medição de Risco
13.
J Dent Res ; 93(12): 1270-6, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25201918

RESUMO

This article presents details of fabrication, biological activity (i.e., anti-matrix metalloproteinase [anti-MMP] inhibition), cytocompatibility, and bonding characteristics to dentin of a unique doxycycline (DOX)-encapsulated halloysite nanotube (HNT)-modified adhesive. We tested the hypothesis that the release of DOX from the DOX-encapsulated nanotube-modified adhesive can effectively inhibit MMP activity. We incorporated nanotubes, encapsulated or not with DOX, into the adhesive resin of a commercially available bonding system (Scotchbond Multi-Purpose [SBMP]). The following groups were tested: unmodified SBMP (control), SBMP with nanotubes (HNT), and DOX-encapsulated nanotube-modified adhesive (HNT+DOX). Changes in degree of conversion (DC) and microtensile bond strength were evaluated. Cytotoxicity was examined on human dental pulp stem cells (hDPSCs). To prove the successful encapsulation of DOX within the adhesives-but, more important, to support the hypothesis that the HNT+DOX adhesive would release DOX at subantimicrobial levels-we tested the antimicrobial activity of synthesized adhesives and the DOX-containing eluates against Streptococcus mutans through agar diffusion assays. Anti-MMP properties were assessed via ß-casein cleavage assays. Increasing curing times (10, 20, 40 sec) led to increased DC values. There were no statistically significant differences (p > .05) in DC within each increasing curing time between the modified adhesives compared to SBMP. No statistically significant differences in microtensile bond strength were noted. None of the adhesives eluates were cytotoxic to the human dental pulp stem cells. A significant growth inhibition of S. mutans by direct contact illustrates successful encapsulation of DOX into the experimental adhesive. More important, DOX-containing eluates promoted inhibition of MMP-1 activity when compared to the control. Collectively, our findings provide a solid background for further testing of encapsulated MMP inhibitors into the synthesis of therapeutic adhesives that may enhance the longevity of hybrid layers and the overall clinical performance of adhesively bonded resin composite restorations.


Assuntos
Antibacterianos/química , Adesivos Dentinários/química , Doxiciclina/química , Nanotubos/química , Silicatos de Alumínio/síntese química , Silicatos de Alumínio/química , Silicatos de Alumínio/toxicidade , Antibacterianos/síntese química , Antibacterianos/toxicidade , Caseínas/efeitos dos fármacos , Técnicas de Cultura de Células , Argila , Colagem Dentária , Polpa Dentária/citologia , Polpa Dentária/efeitos dos fármacos , Dentina/efeitos dos fármacos , Dentina/ultraestrutura , Adesivos Dentinários/síntese química , Adesivos Dentinários/toxicidade , Doxiciclina/síntese química , Doxiciclina/toxicidade , Humanos , Teste de Materiais , Metaloproteinase 1 da Matriz/efeitos dos fármacos , Inibidores de Metaloproteinases de Matriz/química , Nanotubos/toxicidade , Polimerização , Cimentos de Resina/síntese química , Cimentos de Resina/química , Cimentos de Resina/toxicidade , Células-Tronco/efeitos dos fármacos , Streptococcus mutans/efeitos dos fármacos , Estresse Mecânico , Resistência à Tração , Fatores de Tempo
14.
Oper Dent ; 39(2): 144-51, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23786611

RESUMO

OBJECTIVE: This study evaluated the effect of quantity of resin composite, C-factor, and geometry in Class V restorations on shrinkage stress after bulk fill insertion of resin using two-dimensional finite element analysis. METHODS: An image of a buccolingual longitudinal plane in the middle of an upper first premolar and supporting tissues was used for modeling 10 groups: cylindrical cavity, erosion, and abfraction lesions with the same C-factor (1.57), a second cylindrical cavity and abfraction lesion with the same quantity of resin (QR) as the erosion lesion, and then all repeated with a bevel on the occlusal cavosurface angle. The 10 groups were imported into Ansys 13.0 for two-dimensional finite element analysis. The mesh was built with 30,000 triangle and square elements of 0.1 mm in length for all the models. All materials were considered isotropic, homogeneous, elastic, and linear, and the resin composite shrinkage was simulated by thermal analogy. The maximum principal (MPS) and von Mises stresses (VMS) were analyzed for comparing the behavior of the groups. RESULTS: Different values of angles for the cavosurface margin in enamel and dentin were obtained for all groups and the higher the angle, the lower the stress concentration. When the groups with the same C-factor and QR were compared, the erosion shape cavity showed the highest MPS and VMS values, and abfraction shape, the lowest. A cavosurface bevel decreased the stress values on the occlusal margin. The geometry factor overcame the effects of C-factor and QR in some situations. CONCLUSION: Within the limitations of the current methodology, it is possible to conclude that the combination of all variables studied influences the stress, but the geometry is the most important factor to be considered by the operator.


Assuntos
Resinas Compostas/uso terapêutico , Cárie Dentária/patologia , Restauração Dentária Permanente/métodos , Dente Pré-Molar/patologia , Preparo da Cavidade Dentária/métodos , Falha de Restauração Dentária , Análise do Estresse Dentário , Humanos
15.
J Dent Res ; 92(11): 963-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24056225

RESUMO

Here we report the synthesis, materials characterization, antimicrobial capacity, and cytocompatibility of novel antibiotic-containing scaffolds. Metronidazole (MET) or Ciprofloxacin/(CIP) was mixed with a polydioxanone (PDS)polymer solution at 5 and 25 wt% and processed into fibers. PDS fibers served as a control. Scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), tensile testing, and high-performance liquid chromatography (HPLC) were used to assess fiber morphology, chemical structure, mechanical properties, and drug release, respectively. Antimicrobial properties were evaluated against those of Porphyromonas gingivalis/Pg and Enterococcus faecalis/Ef. Cytotoxicity was assessed in human dental pulp stem cells (hDPSCs). Statistics were performed, and significance was set at the 5% level. SEM imaging revealed a submicron fiber diameter. FTIR confirmed antibiotic incorporation. The tensile values of hydrated 25 wt% CIP scaffold were significantly lower than those of all other groups. Analysis of HPLC data confirmed gradual, sustained drug release from the scaffolds over 48 hrs. CIP-containing scaffolds significantly (p < .00001) inhibited biofilm growth of both bacteria. Conversely, MET-containing scaffolds inhibited only Pg growth. Agar diffusion confirmed the antimicrobial properties against specific bacteria for the antibiotic-containing scaffolds. Only the 25 wt% CIP-containing scaffolds were cytotoxic. Collectively, this study suggests that polymer-based antibiotic-containing electrospun scaffolds could function as a biologically safe antimicrobial drug delivery system for regenerative endodontics.


Assuntos
Materiais Biocompatíveis/química , Regeneração Tecidual Guiada/métodos , Nanofibras/química , Tratamento do Canal Radicular/métodos , Alicerces Teciduais/química , Anti-Infecciosos/química , Anti-Infecciosos/farmacologia , Anti-Infecciosos/toxicidade , Materiais Biocompatíveis/síntese química , Materiais Biocompatíveis/toxicidade , Biofilmes/efeitos dos fármacos , Cromatografia Líquida de Alta Pressão , Ciprofloxacina/química , Ciprofloxacina/farmacologia , Ciprofloxacina/toxicidade , Polpa Dentária/citologia , Polpa Dentária/efeitos dos fármacos , Difusão , Módulo de Elasticidade , Enterococcus faecalis/efeitos dos fármacos , Humanos , Teste de Materiais , Metronidazol/química , Metronidazol/farmacologia , Metronidazol/toxicidade , Microscopia Eletrônica de Varredura , Nanofibras/toxicidade , Polidioxanona/química , Polidioxanona/toxicidade , Porphyromonas gingivalis/efeitos dos fármacos , Espectroscopia de Infravermelho com Transformada de Fourier , Células-Tronco/efeitos dos fármacos , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo
16.
Int Endod J ; 46(7): 688-95, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23331240

RESUMO

AIM: To investigate the effect of medicaments used in endodontic regeneration on root fracture resistance and microhardness of radicular dentine. METHODOLOGY: The root canals of mandibular premolars (n = 180) were instrumented and randomized into three treatment groups and an untreated control group. Each treatment group received either triple antibiotic paste (TAP), double antibiotic paste (DAP) or calcium hydroxide paste [Ca(OH)2] intracanal medicament. Teeth were kept in saline for 1 week, 1 month or 3 months. After each time-point, 15 teeth were randomly selected from each group and two root cylinders were obtained from each tooth. One cylinder was subjected to a fracture resistance test, and the other cylinder was used for a microhardness test. Two-way ANOVA and Tukey's pairwise comparisons were used for statistical analysis. RESULTS: For the microhardness test, the two-way interaction between group and time was significant (P < 0.001). The intracanal application of TAP and DAP caused significant and continuous decrease in root dentine microhardness after one (P < 0.05) and 3 months (P < 0.001), respectively. The three-month intracanal application of Ca(OH)2 significantly increased the microhardness of root dentine (P < 0.05). The time factor had a significant effect on fracture resistance (P < 0.001). The three intracanal medicaments caused significant decreases in fracture resistance ranging between 19% and 30% after 3-month application compared to 1-week application. CONCLUSION: In this laboratory study, the 3-month application of triple antibiotic paste, double antibiotic paste or calcium hydroxide paste medicaments significantly reduced the root fracture resistance of extracted teeth compared to a 1-week application.


Assuntos
Apexificação/métodos , Dentina/efeitos dos fármacos , Irrigantes do Canal Radicular/uso terapêutico , Fraturas dos Dentes/fisiopatologia , Raiz Dentária/efeitos dos fármacos , Antibacterianos/administração & dosagem , Dente Pré-Molar/efeitos dos fármacos , Hidróxido de Cálcio/uso terapêutico , Ciprofloxacina/administração & dosagem , Dentina/ultraestrutura , Combinação de Medicamentos , Dureza , Humanos , Teste de Materiais , Metronidazol/administração & dosagem , Microscopia Eletrônica de Varredura , Minociclina/administração & dosagem , Preparo de Canal Radicular/métodos , Camada de Esfregaço , Fatores de Tempo , Raiz Dentária/lesões , Raiz Dentária/ultraestrutura
17.
Int Endod J ; 46(2): 112-8, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22970899

RESUMO

The aim of this review was to identify and analyse all studies related to the effect of nonsetting calcium hydroxide [Ca(OH)(2)] on root fracture and various mechanical properties of radicular dentine. A PubMed search was conducted using the keywords 'calcium hydroxide' and 'dentistry' combined with MeSH terms 'tooth fractures' or 'mechanical phenomena' or 'compressive strength'. The search was expanded by including Embase and Web of Science databases, using the keywords 'calcium hydroxide' and 'root' and 'fracture'. The search was supplemented by checking the reference lists from each selected article. Each study had to meet the following criteria to be selected for review: (i) Inclusion of at least one experimental group with root or radicular dentine either filled with or exposed to nonsetting Ca(OH)(2); (ii) inclusion of at least one appropriate control group; and (iii) a minimum of five samples per experimental group. Only articles written in English were included. Of the 16 studies selected initially, 12 in vitro studies fulfilled the selection criteria for inclusion in the final review. No clinical studies that directly supported the correlation between Ca(OH)(2) intracanal dressing and root fracture were found in the literature. However, the majority of in vitro studies showed reduction in the mechanical properties of radicular dentine after exposure to Ca(OH)(2) for 5 weeks or longer. Conversely, the data were inconclusive regarding whether Ca(OH)(2) exposure for 1 month or less had a negative effect on the mechanical properties of radicular dentine.


Assuntos
Hidróxido de Cálcio/efeitos adversos , Dentina/efeitos dos fármacos , Materiais Restauradores do Canal Radicular/efeitos adversos , Fraturas dos Dentes/etiologia , Raiz Dentária/efeitos dos fármacos , Animais , Bovinos , Força Compressiva/efeitos dos fármacos , Análise do Estresse Dentário , Módulo de Elasticidade/efeitos dos fármacos , Dureza/efeitos dos fármacos , Humanos , Ovinos
18.
Oper Dent ; 38(1): 91-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22830537

RESUMO

OBJECTIVE: This laboratory study compared the repaired microtensile bond strengths of aged silorane resin composite using different surface treatments and either silorane or methacrylate resin composite. METHODS: One hundred eight silorane resin composite blocks (Filtek LS) were fabricated and aged by thermocycling between 8°C and 48°C (5000 cycles). A control (solid resin composite) and four surface treatment groups (no treatment, acid treatment, aluminum oxide sandblasting, and diamond bur abrasion) were tested (N=12 blocks, 108 beams/group). Each treatment group was randomly divided in half and repaired with either silorane resin composite (LS adhesive) or methacrylate resin composite (Filtek Z250/Single Bond Plus). After 24 hours in 37°C distilled water, microtensile bond strength testing was performed using a non-trimming technique. Surface topography after surface treatment was analyzed using scanning electron microscopy (SEM). Failure mode was examined using optical microscopy (50×). RESULTS: Weibull-distribution survival analysis revealed that aluminum oxide sandblasting followed by silorane or methacrylate resin composite and acid treatment with methacrylate resin composite provided insignificant differences from the control (p>0.05). All other groups were significantly lower than the control. Failure was primarily adhesive in all groups. CONCLUSION: Aluminum oxide sandblasting produced microtensile bond strength not different from the cohesive strength of silorane resin composite. After aluminum oxide sandblasting, aged silorane resin composite can be repaired with either silorane resin composite with LS system adhesive or methacrylate resin composite with methacrylate dental adhesive.


Assuntos
Resinas Compostas/química , Colagem Dentária , Materiais Dentários/química , Resinas de Silorano/química , Condicionamento Ácido do Dente/métodos , Adesividade , Óxido de Alumínio/química , Bis-Fenol A-Glicidil Metacrilato/química , Corrosão Dentária/métodos , Reparação de Restauração Dentária , Análise do Estresse Dentário/instrumentação , Diamante/química , Humanos , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Ácidos Fosfóricos/química , Estresse Mecânico , Propriedades de Superfície , Temperatura , Resistência à Tração , Fatores de Tempo , Água/química
19.
Oper Dent ; 38(3): E1-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23131133

RESUMO

UNLABELLED: Aged resin composites have a limited number of carbon-carbon double bonds to adhere to a new layer of resin. Study objectives were to 1) evaluate various surface treatments on repaired shear bond strength between aged and new resin composites and 2) to assess the influence of a silane coupling agent after surface treatments. METHODS: Eighty disk-shape resin composite specimens were fabricated and thermocycled 5000 times prior to surface treatment. Specimens were randomly assigned to one of the three surface treatment groups (n=20): 1) air abrasion with 50-µm aluminum oxide, 2) tribochemical silica coating (CoJet), or 3) Er,Cr:YSGG (erbium, chromium: yttrium-scandium-gallium-garnet) laser or to a no-treatment control group (n=20). Specimens were etched with 35% phosphoric acid, rinsed, and dried. Each group was divided into two subgroups (n=10): A) no silanization and B) with silanization. The adhesive agent was applied and new resin composite was bonded to each conditioned surface. Shear bond strength was evaluated and data analyzed using two-way analysis of variance (ANOVA). RESULTS: Air abrasion with 50-µm aluminum oxide showed significantly higher repair bond strength than the Er,Cr:YSGG laser and control groups. Air abrasion with 50-µm aluminum oxide was not significantly different from tribochemical silica coating. Tribochemical silica coating had significantly higher repair bond strength than Er,Cr:YSGG laser and the control. Er,Cr:YSGG laser and the control did not have significantly different repair bond strengths. Silanization had no influence on repair bond strength for any of the surface treatment methods. CONCLUSION: Air abrasion with 50-µm aluminum oxide and tribochemical silica followed by the application of bonding agent provided the highest repair shear bond strength values, suggesting that they might be adequate methods to improve the quality of repairs of resin composites.


Assuntos
Resinas Compostas/química , Colagem Dentária , Corrosão Dentária/métodos , Lasers de Estado Sólido , Silanos/química , Condicionamento Ácido do Dente/métodos , Resinas Acrílicas/química , Óxido de Alumínio/química , Reparação de Restauração Dentária , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Ácidos Fosfóricos/química , Cimentos de Resina/química , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo
20.
Oper Dent ; 37(2): 181-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22166107

RESUMO

The current study evaluated the influence of a novel surface treatment that uses a low-fusing porcelain glaze for promoting a bond between zirconia-based ceramic and a dual-cure resin luting agent. Bond strengths were compared with those from airborne particle abrasion, hydrofluoric acid etching, and silanization-treated surfaces. Twenty-four yttrium-stabilized tetragonal zirconia (Cercon Smart Ceramics, Degudent, Hanau, Germany) discs were fabricated and received eight surface treatments: group 1: 110 µm aluminum oxide air-borne particle abrasion; group 2: 110 µm aluminum oxide airborne particle abrasion and silane; group 3: 50 µm aluminum oxide airborne particle abrasion; group 4: 50 pm aluminum oxide airborne particle abrasion and silane; group 5: glaze and hydrofluoric acid;group 6: glaze, hydrofluoric acid, and silane;group 7: glaze and 50 pm aluminum oxide airborne particle abrasion; and group 8: glaze,50 pm aluminum oxide airborne particle abrasion and silane. After treatment, Enforce resin cement (Dentsply, Caulk, Milford, DE, USA) was used to fill an iris cut from microbore Tygontubing that was put on the ceramic surface to create 30 cylinders of resin cement in each treatment group (n=30). Micro shear bond test-ing was performed at a cross head speed of 0.5mm/min. One-way analysis of variance, and multiple comparisons were made using Tukey's test (p<0.5). The bond strength was affected only by surface treatments other than silanization. The groups that utilized the low-fusing porcelain glaze with airborne particle abrasion or hydrofluoric acid showed bond strength values statistically superior to groups that utilized conventional airborne particle abrasion treatments with 50 or 110 pm aluminum oxide (p<0.001). The treatment that utilized low-fusing porcelain glaze and hydrofluoric acid showed bond strength values statistically superior to remaining groups (p<0.001). Treatment of zirconia ceramic surfaces with a glaze of low-fusing porcelain significantly increased the bond strength of a dual-cure resin luting agent to the ceramic surface.


Assuntos
Porcelana Dentária/química , Cimentos de Resina/química , Autocura de Resinas Dentárias , Ítrio/química , Zircônio/química , Condicionamento Ácido do Dente/métodos , Óxido de Alumínio/química , Compostos Benzidrílicos , Corrosão Dentária/métodos , Análise do Estresse Dentário/instrumentação , Humanos , Ácido Fluorídrico/química , Teste de Materiais , Metacrilatos/química , Resistência ao Cisalhamento , Silanos/química , Estresse Mecânico , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...