Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Curr Diabetes Rev ; 12(4): 460-467, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26245310

RESUMO

BACKGROUND: to assess costs and safety of insulin pen devices and safety needles as compared to vial/syringes in hospitalized patients requiring insulin therapy in a General Hospital in Northern Italy. MATERIALS AND METHODS: in a prospective 9-month study, consecutive patients admitted to three Hospital Units received insulin therapy through either a traditional disposable syringe method, or pen/safety needles with dual-ended protection, or disposable safety syringes. We compared the median direct (insulin and devices) and indirect (insulin supply at discharge, insulin wastage) costs of a 10-day in-hospital insulin treatment in the 3 study groups, additionally accounting for the costs related to the observed needlestick injury rate. Patients' safety during in-hospital stay (hypo- and hyperglycemia episodes) and satisfaction were also assessed. RESULTS: N=360 patients (55% men, mean age 75.6 years, 57% with DM since ≥10 years) were recruited in the study. Insulin pens had higher median direct cost than both traditional syringes (43 vs. 18 ε/patient, p<.0001) and safety syringes (21.5 ε/patient, p<.0001). However, when also indirect and injuries costs were taken into account, the estimated savings for using pens over traditional syringes were as high as 32 ε/patient (45.8 vs. 77.6 ε/patient, p-value <.0001). No differences in patients' safety were observed. 74% and 12% of patients using pens and syringes would like to continue the method at home, respectively (p<0.0001). DISCUSSION: A selective use of individual pre-filled pens/safety needles for patients who are likely to continue insulin therapy at home may strongly reduce hospital diabetes treatment related costs.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Insulina/administração & dosagem , Insulina/efeitos adversos , Agulhas/efeitos adversos , Seringas/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Feminino , Hospitalização , Humanos , Hiperglicemia/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Injeções Subcutâneas , Itália , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente
2.
Artigo em Inglês | MEDLINE | ID: mdl-28702233

RESUMO

BACKGROUND: A paucity of data exists to examine nurses' satisfaction with the use of insulin pens with safety needles in hospitalized patients with diabetes. We investigated major determinants of nurses' preference of the method of insulin administration in the context of a General Hospital in Northern Italy. METHODS: Consecutive patients admitted to three hospital units of different care intensity requiring insulin received insulin therapy through either the vial/syringe method (October to December 2012) or pen/safety needles with dual-ended protection method (January to March 2013). Before the implementation of insulin pens, floor nurses received a specific training program for proper insulin pen injection technique including individual testing of the devices (pen/safety needles). At the end of the study, nurses completed the Nursing Satisfaction Survey Questionnaire. Cronbach's alpha was used to determine the internal consistency and reliability of the questionnaire. Major determinants of satisfaction were investigated through an exploratory factor analysis. The association between each retained factor and time spent to teach patients how to self-inject insulin with pen devices was also investigated. RESULTS: Fifty-three out of 60 nurses (mean age ± SD 36.2 ± 8.5 years, 85 % women, 57 % with 10+ years of working experience) returned the questionnaire. Internal consistency of the questionnaire was satisfactory (Cronbach's alpha > 0.9). Three months after their introduction, about 92 % of nurses considered pen devices an "improvement" over the vial/syringe method. Two factors explained 85 % of nurses' satisfaction, one related to convenience and ease of use, and the other to satisfaction/time spent for dose preparation and administration. The latter factor was inversely correlated with time spent on patients' training tasks. CONCLUSIONS: Nurses' satisfaction with pen devices was higher than previously reported, possibly reinforced by safety needles with dual-ended protection. Perceived workload was a major determinant of nurse satisfaction using pen devices with safety needles. To facilitate the introduction of insulin pens in the hospital setting, it should be specifically addressed during training programs in the switch-over period.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...