Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(10)2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37430761

RESUMO

Ambulatory instrumented insoles are widely used in real-time monitoring of the plantar pressure in order to calculate balance indicators such as Center of Pressure (CoP) or Pressure Maps. Such insoles include many pressure sensors; the required number and surface area of the sensors used are usually determined experimentally. Additionally, they follow the common plantar pressure zones, and the quality of measurement is usually strongly related to the number of sensors. In this paper, we experimentally investigate the robustness of an anatomical foot model, combined with a specific learning algorithm, to measure the static displacement of the center of pressure (CoP) and the center of total pressure (CoPT), as a function of the number, size, and position of sensors. Application of our algorithm to the pressure maps of nine healthy subjects shows that only three sensors per foot, with an area of about 1.5 × 1.5 cm2, are needed to give a good approximation of the CoP during quiet standing when placed on the main pressure areas.


Assuntos
, Extremidade Inferior , Humanos , Algoritmos , Voluntários Saudáveis , Modelos Anatômicos
2.
Sensors (Basel) ; 23(6)2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36991622

RESUMO

Diffuse reflectance spectroscopy (DRS) has proven to be a powerful, reliable, and non-invasive optical method for characterizing a specimen. Nevertheless, these methods are based on a rudimentary interpretation of the spectral response and can be irrelevant to understanding 3D structures. In this work, we proposed adding optical modalities into a customized handheld probe head in order to increase the number of parameters in DRS acquired from the light/matter interaction. It consists of (1) placing the sample in a reflectance manual rotation stage to collect spectral backscattered angularly resolved light and (2) illuminating it with two sequential linear polarization orientations. We demonstrate that this innovative approach leads to a compact instrument, capable of performing fast polarization-resolved spectroscopic analysis. Due to the significant amount of data available with this technique in a short time, we observe sensitive quantitative discrimination between two types of biological tissue provided by a raw rabbit leg. We believe that this technique can pave the way for rapid meat quality check or biomedical diagnosis of pathological tissues in situ at an early stage.

3.
Opt Express ; 25(24): 30799-30806, 2017 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-29221106

RESUMO

We demonstrate the fabrication of a Vernier effect SU8/PMATRIFE polymer optical biosensor with high homogeneous sensitivity using a standard photolithography process. The sensor is based on one micro-resonator embedded on each arm of a Mach-Zehnder interferometer. Measurements are based on the refractive index variation of the optical waveguide superstrate with different concentrations of glucose solutions. The sensitivity of the sensor has been measured as 17558 nm/RIU and the limit of detection has been estimated to 1.1.10-6 RIU.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...