Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanomaterials (Basel) ; 13(9)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37177012

RESUMO

The importance of nitrite ions has long been recognized due to their extensive use in environmental chemistry and public health. The growing use of nitrogen fertilizers and additives containing nitrite in processed food items has increased exposure and, as a result, generated concerns about potential harmful health consequences. This work presents the development of an electrochemical sensor based on graphene/glassy carbon electrode (EGr/GC) with applicability in trace level detection of nitrite in water samples. According to the structural characterization of the exfoliated material, it appears as a mixture of graphene oxide (GO; 21.53%), few-layers graphene (FLG; 73.25%) and multi-layers graphene (MLG; 5.22%) and exhibits remarkable enhanced sensing response towards nitrite compared to the bare electrode (three orders of magnitude higher). The EGr/GC sensor demonstrated a linear range between 3 × 10-7 and 10-3 M for square wave voltammetry (SWV) and between 3 × 10-7 and 4 × 10-4 M for amperometry (AMP), with a low limit of detection LOD (9.9 × 10-8 M). Excellent operational stability, repeatability and interference-capability were displayed by the modified electrode. Furthermore, the practical applicability of the sensor was tested in commercially available waters with excellent results.

2.
Microorganisms ; 11(3)2023 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-36985318

RESUMO

Bacterial infections are a major concern as antibiotic resistance poses a great threat, therefore leading to a race against time into finding new drugs or improving the existing resources. Nanomaterials with high surface area and bactericidal properties are the most promising ones that help combating microbial infections. In our case, graphene decorated with silver nanoparticles Gr-Ag (5 wt% Ag) exhibited inhibitory capacity against S. aureus and E. coli. The newly formed hybrid material was next incubated with high-efficiency particulate air (HEPA) filter, to obtain one with bactericidal properties. The modified filter had greater inhibitory action against the tested strains, compared to the control, and the effect was better against the Gram-negative model. Even if the bacteria remained attached to the filters, their colony forming unit capacity was affected by the Gr-Ag (5 wt% Ag) hybrid material, when they were subsequently re-cultured on fresh agar media. Therefore, the HEPA filter modified with Gr-Ag (5 wt% Ag) has high antibacterial properties that may substantially improve the existing technology.

3.
Sensors (Basel) ; 23(4)2023 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-36850755

RESUMO

Due to the recent increase in average living standards, food safety has caught public attention. It is necessary to conduct a qualitative and quantitative rapid test of prohibited food additives since the inclusion of food additives or the improper usage of synthetic dyes can negatively impact on the human health. Herein, a highly sensitive method for Sunset Yellow detection based on a glassy carbon electrode modified with few-layer graphenes was proposed. The electrochemical behavior of SY at the GR-exf/GCE modified surface was investigated by Cyclic Voltammetry, Square Wave Voltammetry, Electrochemical Impedance Spectroscopy and Amperometry. The influences of pH, scan rate, and interfering species were studied. Under optimized conditions, the developed sensor shows good linearity over a broad SY concentration range, e.g., 0.028-30 µM, with a low limit of detection (LOD = 0.0085 µM) and quantification (LOQ = 0.028 µM) (data obtained by amperometric technique). Furthermore, the modified electrode shows good selectivity, precision and sensitivity and has been successfully applied for SY quantification from commercially available pharmaceutical formulation as well as from candy bars and orange juice.


Assuntos
Grafite , Humanos , Carbono , Eletrodos , Aditivos Alimentares
4.
Int J Mol Sci ; 23(23)2022 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-36499193

RESUMO

Because of the widespread acetaminophen usage and the danger of harmful overdosing effects, developing appropriate procedures for its quantitative and qualitative assay has always been an intriguing and fascinating problem. A quick, inexpensive, and environmentally friendly approach based on direct voltage anodic graphite rod exfoliation in the presence of inorganic salt aqueous solution ((NH4)2SO4-0.3 M) has been established for the preparation of nitrogen-doped graphene (exf-NGr). The XRD analysis shows that the working material appears as a mixture of few (76.43%) and multi-layers (23.57%) of N-doped graphenes. From XPS, the C/O ratio was calculated to be 0.39, indicating a significant number of structural defects and the existence of multiple oxygen-containing groups at the surface of graphene sheets caused by heteroatom doping. Furthermore, the electrochemical performances of glassy carbon electrodes (GCEs) modified with exf-NGr for acetaminophen (AMP) detection and quantification have been assessed. The exf-NGr/GCE-modified electrode shows excellent reproducibility, stability, and anti-interfering characteristics with improved electrocatalytic activity over a wide detection range (0.1-100 µM), with a low limit for AMP detection (LOD = 3.03 nM). In addition, the developed sensor has been successfully applied in real sample analysis for the AMP quantification from different commercially available pharmaceutical formulations.


Assuntos
Grafite , Acetaminofen , Técnicas Eletroquímicas/métodos , Eletrodos , Grafite/química , Nitrogênio/química , Reprodutibilidade dos Testes
5.
Chemosphere ; 309(Pt 1): 136594, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36167211

RESUMO

Four carbon materials, spent coffee-ground biochar, carbon black, short CNTs, and nitrogen-doped few-layer graphene (N-graphene) were tested for their functionalization with a commercial carboxylesterase. Their robustness to variations in time and key physicochemical parameters (temperature and pH) was analysed. In general, carbon nanomaterials showed better performance than biochar, both in terms of binding capacity and resilience in harsh conditions, at statistically significant levels. Among the tested materials, functionalized N-graphene also showed the highest level of inhibition of carboxylesterase by pesticide exposure. Therefore, N-graphene was selected for biotechnological application of pesticide scavenging toxicity in T. thermophila, a ciliate bioindicator of water quality. While immobilization of the enzyme was not effective in the case of carbaryl, a methyl carbamate, in the case of the organophosphorus dichlorvos, a 1- or 30-min contact time with a water solution containing 5 times the LC100 - 0.5 mM - allowed 50% and 100% rescue of ciliate survival, respectively. These results suggest that functionalization with carboxylesterase may be of additional benefit compared to bare carbon in water clean-up procedures, especially for highly hydrophilic pesticides such as dichlorvos.


Assuntos
Grafite , Nanoestruturas , Praguicidas , Praguicidas/toxicidade , Carboxilesterase/metabolismo , Carbaril , Diclorvós , Carbono , Biomarcadores Ambientais , Fuligem , Café , Nitrogênio
6.
Bioelectrochemistry ; 148: 108228, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35970121

RESUMO

A new electrode based on glassy carbon modified with a sulphur-doped graphene material was successfully developed and applied for caffeic acid (CA) voltammetric detection and quantification. The structural features of sulphur-doped graphene (exfGR-S) characterized by different physicochemical and analytical techniques are presented. Cyclic voltammetry (CV) technique was employed to evaluate the electrochemical behavior of both bare glassy carbon (GCE) and modified GCE/exfGr-S electrodes towards CA oxidation. The study revealed that the modified electrode exhibits superior electrochemical performances compared to the bare electrode, with a broad CA detecting range (from 0.1 to 100.0 µM), a low detection limit 3.03 × 10-8 M), excellent anti-interference capabilities, as well as good stability and repeatability. The developed electrochemical sensor appears to be a promising candidate for real sample quality control analysis since it successfully displayed its ability to directly detect CA in commercially available coffee product without any pretreatment.


Assuntos
Grafite , Ácidos Cafeicos , Carbono/química , Café , Técnicas Eletroquímicas , Grafite/química , Enxofre
7.
Sensors (Basel) ; 22(16)2022 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-36015941

RESUMO

An electrochemical cell containing two graphite rods was filled with the appropriate electrolyte (0.2 M ammonia + 0.2 M ammonium sulphate) and connected to the exfoliation system to synthesize graphene (EGr). A bias of 7 V was applied between the anode and cathode for 3 h. After synthesis, the morphology and structure of the sample was characterized by SEM, XRD, and FTIR techniques. The material was deposited onto the surface of a glassy carbon (GC) electrode (EGr/GC) and employed for the electrochemical detection of azithromycin (AZT). The DPV signals recorded in pH 5 acetate containing 6 × 10-5 M AZT revealed significant differences between the GC and EGr/GC electrodes. For EGr/GC, the oxidation peak was higher and appeared at lower potential (+1.12 V) compared with that of bare GC (+1.35 V). The linear range for AZT obtained with the EGr/GC electrode was very wide, 10-8-10-5 M, the sensitivity was 0.68 A/M, and the detection limit was 3.03 × 10-9 M. It is important to mention that the sensitivity of EGr/GC was three times higher than that of bare GC (0.23 A/M), proving the advantages of using graphene-modified electrodes in the electrochemical detection of AZT.


Assuntos
Grafite , Azitromicina/química , Carbono/química , Técnicas Eletroquímicas/métodos , Eletrodos , Grafite/química , Limite de Detecção
8.
Sensors (Basel) ; 22(10)2022 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-35632015

RESUMO

In this study, a graphene sample (EGr) was synthesized by electrochemical exfoliation of graphite rods in electrolyte solution containing 0.1 M ammonia and 0.1 M ammonium thiocyanate. The morphology of the powder deposited onto a solid substrate was investigated by the scanning electron microscopy (SEM) technique. The SEM micrographs evidenced large and smooth areas corresponding to the basal plane of graphene as well as white lines (edges) where graphene layers fold-up. The high porosity of the material brings a major advantage, such as the increase of the active area of the modified electrode (EGr/GC) in comparison with that of bare glassy carbon (GC). The graphene modified electrode was successfully tested for L-tyrosine detection and the results were compared with those of bare GC. For EGr/GC, the oxidation peak of L-tyrosine had high intensity (1.69 × 10-5 A) and appeared at lower potential (+0.64 V) comparing with that of bare GC (+0.84 V). In addition, the graphene-modified electrode had a considerably larger sensitivity (0.0124 A/M) and lower detection limit (1.81 × 10-6 M), proving the advantages of employing graphene in electrochemical sensing.


Assuntos
Grafite , Carbono , Técnicas Eletroquímicas/métodos , Eletrodos , Tirosina
9.
Sensors (Basel) ; 21(19)2021 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-34640950

RESUMO

A sample of nitrogen and boron co-doped graphene (NB-Gr) was obtained by the hydrothermal method using urea and boric acid as doping sources. According to XRD analysis, the NB-Gr sample was formed by five-layer graphene. In addition, the XPS analysis confirmed the nitrogen and boron co-doping of the graphene sample. After synthesis, the investigation of the electro-catalytic properties of the bare (GC) and graphene-modified electrode (NB-Gr/GC) towards cymoxanil detection (CYM) was performed. Significant differences between the two electrodes were noticed. In the first case (GC) the peak current modulus was small (1.12 × 10-5 A) and appeared in the region of negative potentials (-0.9 V). In contrast, when NB-Gr was present on top of the GC electrode it promoted the transfer of electrons, leading to a large peak current increase (1.65 × 10-5 A) and a positive shift of the peak potential (-0.75 V). The NB-Gr/GC electrode was also tested for its ability to detect cymoxanil from a commercial fungicide (CURZATE MANOX) by the standard addition method, giving a recovery of 99%.


Assuntos
Grafite , Acetamidas , Boro , Nitrogênio
10.
Biosensors (Basel) ; 11(2)2021 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-33525714

RESUMO

A graphene sample (EGr) was prepared by electrochemical exfoliation of graphite rods in solution containing 0.05 M (NH4)2SO4 + 0.1 M H3BO3 + 0.05 M NaCl. The exfoliation was performed by applying a constant voltage (12 V) between the graphite rods, while the temperature was kept constant (18 °C) with a temperature-controlled cryostat. The structural investigation of the graphene sample, performed by X-ray powder diffraction (XRD), revealed that the sample consists of a mixture of few-layer (69%), multi-layer graphene (14%) and graphene oxide (17%). In addition, XPS analysis proved that the sample was triple-doped with heteroatoms such as nitrogen (1.7 at%), sulfur (2.5 at%), and boron (3 at%). The sample was deposited onto the surface of a clean, glassy carbon electrode (GC) and investigated for the non-enzymatic electrochemical detection of L-tryptophan (TRP). The electrocatalytic properties of the EGr/GC electrode led to a considerable decrease in the oxidation potential from +0.9 V (bare GC) to +0.72 V. In addition, the EGr/GC electrode has higher sensitivity (two times) and a lower detection limit (ten times) in comparison with the bare GC electrode.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Eletrodos , Grafite/química , Triptofano/análise , Oxirredução
11.
Nanomaterials (Basel) ; 10(8)2020 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-32727153

RESUMO

N-doped graphene-ZnO hybrid materials with different N-doped graphene:ZnO wt% ratios (1:10; 1:20; 1:30) were prepared by a simple and inexpensive sol-gel method. The materials denoted NGr-ZnO-1 (1:10), NGr-ZnO-2 (1:20), and NGr-ZnO-3 (1:30) were investigated with advanced techniques and their morpho-structural, photocatalytic, and electrocatalytic properties were reported. Hence, pure N-doped graphene sample contains flakes with the size ranging from hundreds of nanometers to micrometers. In the case of all NGr-ZnO hybrid materials, the flakes appear heavily decorated with ZnO nanoparticles, having a cauliflower-like morphology. The X-ray powder diffraction (XRD) investigation of N-doped graphene sample revealed that it was formed by a mixture of graphene oxide, few-and multi-layer graphene. After the ZnO nanoparticles were attached to graphene, major diffraction peaks corresponding to crystalline planes of ZnO were seen. The qualitative and quantitative compositions of the samples were further evidenced by X-ray photoelectron spectroscopy (XPS). In addition, UV photoelectron spectroscopy (UPS) spectra allowed the determination of the ionization energy and valence band maxima. The energy band alignment of the hybrid materials was established by combining UV-Vis with UPS results. A high photocatalytic activity of NGr-ZnO samples against rhodamine B solution was observed. The associated reactive oxygen species (ROS) generation was monitored by electron paramagnetic resonance (EPR)-spin trapping technique. In accordance with bands alignment and identification of radical species, the photocatalytic mechanism was elucidated.

12.
Sensors (Basel) ; 20(12)2020 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-32604924

RESUMO

Flexible screen-printed electrodes (HP) were fabricated on stone paper substrate and amperometrically modified with gold nanoparticles (HP-AuNPs). The modified electrode displayed improved electronic transport properties, reflected in a low charge-transfer resistance (1220 Ω) and high apparent heterogeneous electron transfer rate constant (1.94 × 10-3 cm/s). The voltammetric detection of dopamine (DA) was tested with HP and HP-AuNPs electrodes in standard laboratory solutions (pH 6 phosphate-buffered saline (PBS)) containing various concentrations of analyte (10-7-10-3 M). As expected, the modified electrode exhibits superior performances in terms of linear range (10-7-10-3 M) and limit of detection (3 × 10-8 M), in comparison with bare HP. The determination of DA was tested with HP-AuNPs in spiked artificial urine and in pharmaceutical drug solution (ZENTIVA) that contained dopamine hydrochloride (5 mg/mL). The results obtained indicated a very good DA determination in artificial urine without significant matrix effects. In the case of the pharmaceutical drug solution, the DA determination was affected by the interfering species present in the vial, such as sodium metabisulfite, maleic acid, sodium chloride, and propylene glycol.


Assuntos
Dopamina/análise , Eletrodos , Ouro , Nanopartículas Metálicas , Técnicas Eletroquímicas , Limite de Detecção
13.
Sensors (Basel) ; 20(7)2020 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-32218144

RESUMO

Three nitrogen-doped graphene samples were synthesized by the hydrothermal method using urea as doping/reducing agent for graphene oxide (GO), previously dispersed in water. The mixture was poured into an autoclave and placed in the oven at 160 °C for 3, 8 and 12 h. The samples were correspondingly denoted NGr-1, NGr-2 and NGr-3. The effect of the reaction time on the morphology, structure and electrochemical properties of the resulting materials was thoroughly investigated using scanning electron microscopy (SEM) Raman spectroscopy, X-ray powder diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), elemental analysis, Cyclic Voltammetry (CV) and electrochemical impedance spectroscopy (EIS). For NGr-1 and NGr-2, the nitrogen concentration obtained from elemental analysis was around 6.36 wt%. In the case of NGr-3, a slightly higher concentration of 6.85 wt% was obtained. The electrochemical studies performed with NGr modified electrodes proved that the charge-transfer resistance (Rct) and the apparent heterogeneous electron transfer rate constant (Kapp) depend not only on the nitrogen doping level but also on the type of nitrogen atoms found at the surface (pyrrolic-N, pyridinic-N or graphitic-N). In our case, the NGr-1 sample which has the lowest doping level and the highest concentration of pyrrolic-N among all nitrogen-doped samples exhibits the best electrochemical parameters: a very small Rct (38.3 Ω), a large Kapp (13.9 × 10-2 cm/s) and the best electrochemical response towards 8-hydroxy-2'-deoxyguanosine detection (8-OHdG).

14.
Environ Res ; 182: 109047, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31865167

RESUMO

The release of synthetic food dyes, like Sunset yellow, into industrial effluents can cause serious environmental and health problems. Due to its aromatic structure, it is recalcitrant towards degradation into non-toxic intermediates and its removal by efficient adsorption represents a cheap and efficient method. Herein we propose the use of thermally reduced graphene oxide (TRGO) as effective Sunset yellow dye adsorbent with an adsorption maximum capacity comparable with other sophisticated, chemically synthesized carbon-based nanomaterials. The reduced graphene oxide and the Sunset yellow adsorbed one were characterized by FT-IR, XPS and XRD spectroscopy, N2 adsorption-desorption isotherm and TGA analysis. BET surface area reduced from 274.1 m2/g (for TRGO) to 39.9 m2/g (for TRGO-SY) showing that Sunset Yellow molecules occupied the corresponding active sites while the number of sheets resulted from the XRD spectra - from 3 to 8 in TRGO to 5 in TRGO-SY indicates the ordered intercalations in the graphene structure. The adsorption isotherm experimental data were better fitted with the Langmuir model than the Freundlich model, with the maximum adsorption capacity of the SY dye monolayer of 243.3 mg/g at pH = 6.0 and 189.0 mg/g from synthetic wastewater. The kinetic study revealed a perfect fit following the Pseudo-second order model with an equilibrium achieved within 30 min. The lack of adsorption on the starting graphene oxide is indicative for π-π interactions between the adsorbate and adsorbent.


Assuntos
Compostos Azo , Descontaminação , Grafite , Adsorção , Concentração de Íons de Hidrogênio , Cinética , Espectroscopia de Infravermelho com Transformada de Fourier
15.
Sensors (Basel) ; 19(19)2019 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-31590208

RESUMO

In this work we present the preparation of graphene material by exfoliation of graphite rods via pulses of current in electrolyte, containing a mixture of boric acid (0.05 M) and sodium chloride (0.05 M). The material was morphologically and structurally characterized by SEM/TEM/HR-TEM, XRD and FTIR techniques. TEM investigation of graphene flakes deposited onto carbon-coated grids allowed the visualization of thin and transparent regions, attributed to few-layer graphene (FLG), as well as thick and dark regions attributed to multi-layer graphene (MLG). The mixed composition of the material was additionally confirmed by XRD, which further indicated that the amount of FLG within the sample was around 83%, while MLG was around 17%. The performance of a screen-printed electrode (SPE) modified with graphene (SPE-Gr) was tested for 8-hydroxy-2'-deoxyguanosine detection. The graphene-modified electrode had a higher sensitivity in comparison with that of SPE, both in standard laboratory solutions (phosphate buffered saline-PBS) and in human saliva.


Assuntos
8-Hidroxi-2'-Desoxiguanosina/isolamento & purificação , Biomarcadores/química , Técnicas Biossensoriais , Técnicas Eletroquímicas , 8-Hidroxi-2'-Desoxiguanosina/química , Carbono/química , Proteínas Filagrinas , Grafite/química , Humanos
16.
Talanta ; 196: 182-190, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30683349

RESUMO

In this paper we present for the first time a novel method for graphene-based materials synthesis, by exfoliation of graphite rods via pulses of current (pulse duration of 2.5 s; pause between two pulses of 0.8 s). The method has several advantages over the classical one (d.c. current exfoliation) such as the prevention of the electrolyte over-heating, the generation of less amount of graphitic material into the final sample, the increase of the synthesis yield, and the excellent reproducibility in sample quality when the synthesis parameters are preserved. The first material (EGr-A) was obtained in strong acidic solution made by a mixture of H2SO4 and HNO3 (3:1 ratio; 1 M each; pH 1). The second material (EGr-S) was prepared in a salt solution of 0.2 M ammonium sulphate (pH 5). Both materials were morphologically and structurally characterized by SEM, XRD and XPS. The XRD investigation proved that the EGr-A sample contains graphene oxide (GO- 39%) along with few-layer graphene (FLG- 44%) and multi-layer graphene (MLG- 17%). In contrast, the EGr-S sample consists of two-layer graphene (89%) and multi-layer graphene (11%). The performances of two glassy carbon (GC) electrodes modified with the graphene based materials (GC/EGr-A and GC/EGr-S) were investigated towards 8-Hydroxy-2'-deoxyguanosine (8-OHdG) detection and compared with those of bare GC. As expected, the graphene-modified electrodes have a high sensitivity (0.67 A M-1 cm-2 for GC/EGr-S and 0.53 A M-1 cm-2 for GC/EGr-A), a wide linear range (3 × 10-7-10-4 M) and low detection limit (LOD = 9.09 × 10-8 M). In contrast, the bare electrode has higher detection limit (LOD = 3 × 10-7 M) and considerably lower sensitivity towards 8-OHdG (0.22 A M-1 cm-2).

17.
Nanotechnology ; 29(9): 095501, 2018 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-29260725

RESUMO

Graphene nanosheets (EGr) were electrochemically prepared through one-step exfoliation of a graphite rod in a mixture of H2SO4:HNO3 (3:1) at low bias (4 V). Subsequently, gold nanoparticles were attached to the graphene surface (EGr-Au) by the reduction of the metal precursor (HAuCl4) in aqueous solution containing dispersed graphene sheets. According to the XRD investigation, the synthesized material consists of a mixture of few-layer (86%) and multi-layer (14%) graphene. The interlayer distance was found to be in the range of 0.466-0.342 nm, which is larger than the interlayer distance in graphite (0.335 nm). The average size of gold nanoparticles in the EGr-Au sample was 24 nm, in excellent agreement with the TEM results. The synthesized material was then employed to modify a glassy carbon (GC) substrate, in order to obtain a modified electrode (GC/EGr-Au). Next, the electrochemical behavior of hydroquinone (HQ) in the presence and absence of interfering species, catechol (CAT) and bisphenol A (BPA) was studied and the corresponding calibration curves were plotted. Thus, in solutions without interfering species, the GC/EGr-Au electrode has a wide linear range (3 × 10-7-10-4 M), high sensitivity (0.089 A M-1) and low detection limit (LOD = 10-7 M; S/N = 3). The presence of either catechol or bisphenol A leads to the increase of LOD to 2 × 10-7 M, and in addition changes the electrode sensitivity, up to 0.146 A M-1.

18.
Nanotechnology ; 28(11): 114001, 2017 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-28054508

RESUMO

A novel nanocomposite was developed and used for trace determination of Pb2+ cations from aqueous solutions. The nanocomposite was obtained by the association of N-doped graphene (N-Gr) with a biocompatible polymer, namely chitosan (Ch). The characterization of the new nanocomposite material (Ch-N-Gr) was performed using TEM, STEM-EDX, SEM, XRD and XPS techniques. Compared with the bare gold electrode (GE) a remarkable enhancement of the voltammetric response of the modified electrode (Ch-N-Gr/GE) was always observed. Using the Ch-N-Gr/GE, the Pb2+ voltammetric response showed a pair of well defined, quasi-reversible anodic and cathodic peaks, with the peak potentials located at about -0.59 V and -0.69 V, respectively. The calibration curves were obtained over a large linear range, from 10-7 to 10-4 M Pb2+ concentration. Under optimized conditions, the detection limit was found to be 6.64 × 10-8 M. The effect of several interfering species (such as other metallic cations or organic compounds of various concentrations) on the determination of Pb2+ concentration was also studied, and the results proved the selectivity of the proposed modified electrode. The validity and effectiveness of the method was further confirmed by trace determination of Pb2+ in real samples.

19.
Nanotechnology ; 27(48): 484001, 2016 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-27804923

RESUMO

This study brings for the first time novel knowledge about the synthesis by catalytic chemical vapor deposition with induction heating of graphene-bimetallic nanoparticle composites (Gr-AuCu and Gr-AgCu) and their morphological and structural characterization by transmission electron microscopy, Raman spectroscopy, and x-ray powder diffraction. Gold electrodes modified with the obtained materials exhibit an enhanced electro-catalytic effect towards one of the most encountered estrogenic disruptive chemicals, bisphenol A (BPA). The BPA behavior in varying pH solutions was investigated using the electrochemical quartz crystal microbalance, which allowed the accurate determination of the number of molecules involved in the oxidation process. The modified electrodes promote the oxidation of BPA at significantly lower potentials (0.66 V) compared to bare gold (0.78 V). In addition, the peak current density recorded with such electrodes greatly exceeded that obtained with bare gold (e.g. one order of magnitude larger, for a Au/Gr-AgCu electrode). The two modified electrodes have low detection limits, of 1.31 × 10-6 M and 1.91 × 10-6 M for Au/Gr-AgCu and Au/Gr-AuCu, respectively. The bare gold electrode has a higher detection limit of 5.1 × 10-6 M. The effect of interfering species (e.g. catechol and 3-nitrophenol) was also investigated. Their presence influenced not only the BPA peak potential, but also the peak current. With both modified electrodes, no peak currents were recorded below 3 × 10-5 M BPA.

20.
Colloids Surf B Biointerfaces ; 136: 791-8, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26529387

RESUMO

Graphene-oxide (GO) and its most encountered derivatives, thermally reduced graphene oxide (TRGO) and nitrogen-doped graphene (N-Gr), were synthesized and structurally characterized by spectroscopic techniques, like Raman and (13)C MAS solid state NMR. Several biological effects (cytotoxicity, oxidative stress induction, and cellular and mithocondrial membrane alterations) induced by such graphene-based materials on human dental follicle stem cells were investigated. Graphene oxide shows the lowest cytotoxic effect, followed by the nitrogen-doped graphene, while thermally reduced graphene oxide exhibits high cytotoxic effects. Graphene oxide induces oxidative stress without causing cell membrane damage. Nitrogen-doped graphene shows a slight antioxidant activity; however, at high doses (20 and 40 µg/ml) it causes membrane damage. Both graphene oxide and nitrogen-doped graphene seem to be valuable candidates for usage in dental nanocomposites.


Assuntos
Grafite/química , Nanoestruturas , Células-Tronco/efeitos dos fármacos , Dente/efeitos dos fármacos , Humanos , Lactente , Microscopia Eletrônica de Transmissão , Células-Tronco/citologia , Dente/citologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...