Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Comput Methods Biomech Biomed Engin ; 26(11): 1330-1340, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36106656

RESUMO

Ligament properties in the literature are variable, yet scarce, but needed to calibrate computational models for spine clinical research applications. A comparison of ligament stiffness properties and their effect on the kinematic behavior of a thoracic functional spinal unit (FSU) is examined in this paper. Six unique ligament property sets were utilized within a volumetric T7-T8 finite element (FE) model developed using computer-aided design (CAD) spinal geometry. A 7.5 Nm moment was applied along three anatomical planes both with and without costovertebral (CV) joints present. Range of Motion (RoM) was assessed for each property set and compared to published experimental data. Intact and serial ligament removal procedures were implemented in accordance with experimental protocol. The variance in both kinematic behavior and comparability with experimental data among property sets emphasizes the role nonlinear characterization plays in determining proper kinematic behavior in spinal FE models. Additionally, a decrease in RoM variation among property sets was exhibited when the model setup incorporated the CV joint. With proper assessment of the source and size of each ligament, the material properties considered here could be expanded and justified for implementation into thoracic spine clinical studies.


Assuntos
Ligamentos Articulares , Coluna Vertebral , Fenômenos Biomecânicos , Articulações , Amplitude de Movimento Articular , Análise de Elementos Finitos , Vértebras Lombares
2.
Biosensors (Basel) ; 6(2): 27, 2016 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-27322338

RESUMO

The functional longevity of a neural probe is dependent upon its ability to minimize injury risk during the insertion and recording period in vivo, which could be related to motion-related strain between the probe and surrounding tissue. A series of finite element analyses was conducted to study the extent of the strain induced within the brain in an area around a neural probe. This study focuses on the transient behavior of neural probe and brain tissue interface with a viscoelastic model. Different stages of the interface from initial insertion of neural probe to full bonding of the probe by astro-glial sheath formation are simulated utilizing analytical tools to investigate the effects of relative motion between the neural probe and the brain while friction coefficients and kinematic frequencies are varied. The analyses can provide an in-depth look at the quantitative benefits behind using soft materials for neural probes.


Assuntos
Encéfalo , Eletrodos Implantados , Microeletrodos , Movimento (Física) , Fenômenos Biomecânicos , Módulo de Elasticidade , Análise de Elementos Finitos , Modelos Teóricos , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...