Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Ultrasound Med ; 42(10): 2247-2255, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37159490

RESUMO

OBJECTIVES: The primary aim was to estimate the influence of various depths on ultrasound attenuation coefficient (AC) of multiple vendors in the liver. The secondary aim was to evaluate the impact of region of interest (ROI) size on AC measurements in a subset of participants. METHODS: This Institutional Review Board (IRB)-approved Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study was carried out in two centers using AC-Canon and AC-Philips algorithms and extracting AC-Siemens values from ultrasound-derived fat fraction algorithm. Measurements were performed positioning ROI upper edge (3 cm size) at 2, 3, 4, 5 cm from the liver capsule with AC-Canon and AC-Philips and at 1.5, 2, 3 cm with Siemens algorithm. In a subset of participants, measurements were obtained with 1 and 3 cm ROI size. Univariate and multivariate linear regression models and Lin's concordance correlation coefficient (CCC) were used for statistical analysis as appropriate. RESULTS: Three different cohorts were studied. Sixty-three participants (34 females; mean age: 51 ± 14 years) were studied with AC-Canon, 60 (46 females; mean age: 57 ± 11 years) with AC-Philips, and 50 (25 females; 61 ± 13 years) with AC-Siemens. There was a decrease in AC values per 1 cm increase in depth in all. In multivariable analysis, the coefficient was -0.049 (-0.060; -0.038 P < .001) with AC-Canon, -0.058 (-0.066; -0.049 P < .001) with AC-Philips and -0.081 (-0.112; -0.050 P < .001) with AC-Siemens. AC values with 1 cm ROI were significantly higher than those obtained with 3 cm ROI at all depths (P < .001) but the agreement between AC values obtained with different ROI size was excellent (CCC 0.82 [0.77-0.88]). CONCLUSIONS: There is depth dependence in AC measurement that affects results. A standardized protocol with fixed ROI's depth and size is needed.


Assuntos
Algoritmos , Fígado , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Reprodutibilidade dos Testes , Fígado/diagnóstico por imagem , Ultrassonografia/métodos
2.
Int J Infect Dis ; 104: 83-84, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33359063

RESUMO

OBJECTIVES: Residents in nursing homes represent a frail, elderly population, and severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection can spread easily in this setting. Despite a frequent severe evolution of coronavirus disease 2019 (COVID-19), these patients often present an atypical course with mild initial symptoms. The aim of this study was to assess the occurrence of fever in elderly patients with COVID-19 residing in nursing homes. METHODS: Two hundred and thirty-one elderly patients from three nursing homes in Pavia and surrounding area were enrolled in April-May 2020. SARS-CoV-2 infection was diagnosed using real-time reverse transcription polymerase chain reaction with nasopharyngeal swab and/or serological assay (LIAISON® SARS-CoV-2 S1/S2 IgG). Patients with a positive result on RT-PCR or serology were classed as positive. RESULTS: In total, 170 patients (74%) were SARS-CoV-2-positive on RT-PCR and/or serology, and 61 patients (26%) had negative results on both tests. Fever (body temperature >37.5 °C) was observed in four patients (1.7%): three in the SARS-CoV-2-positive group (1.8%) and one in the SARS-CoV-2-negative group (1.6%). CONCLUSIONS: The prevalence of fever was extremely low in this population of nursing home residents with COVID-19. This finding must be taken into consideration when screening patients without fever in nursing homes.


Assuntos
COVID-19/diagnóstico , Febre/diagnóstico , Casas de Saúde , SARS-CoV-2 , Idoso , Idoso de 80 Anos ou mais , COVID-19/epidemiologia , Feminino , Humanos , Masculino , Reação em Cadeia da Polimerase em Tempo Real
3.
Liver Int ; 36(12): 1860-1866, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27439331

RESUMO

BACKGROUND & AIMS: Ultrasound is the imaging modality most widely utilized in the general population for diagnostic purposes. Controlled attenuation parameter is a novel noninvasive method for assessing steatosis. Our aim was to investigate whether the clinical value of controlled attenuation parameter in patients referred for abdominal ultrasound examinations is affected by liver fibrosis. METHODS: Consecutive patients referred for abdominal ultrasound examinations were enrolled. Controlled attenuation parameter and liver stiffness were assessed with the FibroScan (Echosens, France). Liver fibrosis was staged according to published cutoffs of liver stiffness measurements. Pearson's or Spearman's rank correlation coefficient was used to test the association between two study variables. Optimal cutoff of controlled attenuation parameter for diagnosing liver steatosis (S≥2) was 256 dB/m. The diagnostic performance and accuracy of dichotomized controlled attenuation parameter, ultrasound and body mass index were analysed using the imperfect gold standard methodology. RESULTS: A total of 726 subjects (464 males and 262 females) were studied. Five hundred and eight-nine (81.1%) patients were affected by chronic viral hepatitis. Correlation of controlled attenuation parameter with ultrasound score was 0.48 and 0.57 in patients with and without chronic viral hepatitis respectively. In patients with chronic viral hepatitis, ultrasound, dichotomized controlled attenuation parameter and body mass index showed performance of 58.2%, 82.3% and 46.7%, respectively, whereas in patients without chronic viral hepatitis, the performance was 86.4%, 68.6% and 48.6% respectively. CONCLUSIONS: In patients with chronic viral hepatitis and advanced liver fibrosis, controlled attenuation parameter performs better than ultrasound for assessing liver steatosis, whereas in patients without viral hepatitis and with nonsignificant liver disease ultrasound shows the best performance.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Fígado/diagnóstico por imagem , Adulto , Idoso , Área Sob a Curva , Índice de Massa Corporal , Estudos Transversais , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Curva ROC , Índice de Gravidade de Doença
4.
World J Gastroenterol ; 19(1): 49-56, 2013 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-23326162

RESUMO

AIM: To compare results of liver stiffness measurements by transient elastography (TE) obtained in our patients population with that used in a recently published meta-analysis. METHODS: This was a single center cross-sectional study. Consecutive patients with chronic viral hepatitis scheduled for liver biopsy at the outpatient ward of our Infectious Diseases Department were enrolled. TE was carried out by using FibroScan™ (Echosens, Paris, France). Liver biopsy was performed on the same day as TE, as day case procedure. Fibrosis was staged according to the Metavir scoring system. The diagnostic performance of TE was assessed by using receiver operating characteristic (ROC) curves and the area under the ROC curve analysis. RESULTS: Two hundred and fifty-two patients met the inclusion criteria. Six (2%) patients were excluded due to unreliable TE measurements. Thus, 246 (171 men and 75 women) patients were analyzed. One hundred and ninety-five (79.3%) patients had chronic hepatitis C, 41 (16.7%) had chronic hepatitis B, and 10 (4.0%) were coinfected with human immunodeficiency virus. ROC curve analysis identified optimal cut-off value of TE as high as 6.9 kPa for F ≥ 2; 7.9 kPa for F ≥ 3; 9.6 kPa for F = 4 in all patients (n = 246), and as high as 6.9 kPa for F ≥ 2; 7.3 kPa for F ≥ 3; 9.3 kPa for F = 4 in patients with hepatitis C (n = 195). Cut-off values of TE obtained by maximizing only the specificity were as high as 6.9 kPa for F ≥ 2; 9.6 kPa for F ≥ 3; 12.2 kPa for F = 4 in all patients (n = 246), and as high as 7.0 kPa for F ≥ 2; 9.3 kPa for F ≥ 3; 12.3 kPa for F = 4 in patients with hepatitis C (n = 195). CONCLUSION: The cut-off values of TE obtained in this single center study are comparable to that obtained in a recently published meta-analysis that included up to 40 studies.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatite B Crônica/fisiopatologia , Hepatite C Crônica/fisiopatologia , Fígado/patologia , Adulto , Biópsia , Estudos Transversais , Técnicas de Imagem por Elasticidade/normas , Feminino , Hepatite B Crônica/complicações , Hepatite C Crônica/complicações , Humanos , Cirrose Hepática/complicações , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Análise de Regressão
5.
Eur J Radiol ; 81(11): 3102-6, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22749107

RESUMO

OBJECTIVE: To evaluate the reproducibility of real-time shear wave elastography in assessing liver elasticity in healthy volunteers. METHODS: Forty-two volunteers were studied in day 1. Shear wave elastography studies were performed by using the ultrasound system Aixplorer™ (SuperSonic Imagine S.A., Aix-en-Provence, France) with a convex broadband probe. Measurements were carried by two operators, an expert (operator 1) and a novice (operator 2). Examinations were performed on the right lobe of the liver. Each operator performed 10 consecutive measurements in each volunteer. In a subset of volunteers (n=18) measurements were performed twice on two different days (day 1 and day 2). Intraobserver and interobserver agreement were assessed by intraclass correlation coefficient. RESULTS: Intraobserver agreement between measurements performed in the same subject in the same day (day 1 or day 2) showed intraclass correlation coefficient values of 0.95 (95% confidence interval, 0.93-0.98) and 0.93 (95% confidence interval, 0.90-0.96) for operator 1 and operator 2, respectively. Intraobserver agreement between measurements performed in the same subject in different days showed intraclass correlation coefficient values of 0.84 (95% confidence interval, 0.69-0.98) and 0.65 (95% confidence interval, 0.39-0.91) for operator 1 and operator 2, respectively. Interobserver agreement was 0.88 (95% confidence interval, 0.82-0.94). CONCLUSIONS: The results of this study show that shear wave elastography is a reliable and reproducible noninvasive method for the assessment of liver elasticity. Expert operator had higher reproducibility of measurements over time than novice operator.


Assuntos
Algoritmos , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Fígado/fisiologia , Adulto , Sistemas Computacionais , Módulo de Elasticidade/fisiologia , Feminino , Humanos , Aumento da Imagem/métodos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
6.
AJR Am J Roentgenol ; 199(1): 19-25, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22733889

RESUMO

OBJECTIVE: The purpose of this article is to evaluate the diagnostic performance of transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index in assessing fibrosis in patients with chronic hepatitis C by using histologic Metavir scores as reference standard. SUBJECTS AND METHODS: Consecutive patients with chronic hepatitis C scheduled for liver biopsy were enrolled. Liver biopsy was performed on the same day as transient elastography and real-time strain elastography. Transient elastography and real-time strain elastography were performed in the same patient encounter by a single investigator using a medical device based on elastometry and an ultrasound machine, respectively. Diagnostic performance was assessed by using receiver operating characteristic curves and area under the receiver operating characteristic curve (AUC) analysis. RESULTS: One hundred thirty patients (91 men and 39 women) were analyzed. The cutoff values for transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index were 6.9 kPa, 1.82, and 0.37, respectively, for fibrosis score of 2 or higher; 7.3 kPa, 1.86, and 0.70, respectively, for fibrosis score of 3 or higher; and 9.3 kPa, 2.33, and 0.70, respectively, for fibrosis score of 4. AUC values of transient elastography, real-time strain elastography, aspartate-to-platelet ratio index were 0.88, 0.74, and 0.86, respectively, for fibrosis score of 2 or higher; 0.95, 0.80, and 0.89, respectively, for fibrosis score of 3 or higher; and 0.97, 0.80, and 0.84, respectively, for fibrosis score of 4. A combination of the three methods, when two of three were in agreement, showed AUC curves of 0.93, 0.95, and 0.95 for fibrosis scores of 2 or higher, 3 or higher, and 4, respectively. CONCLUSION: Transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index values were correlated with histologic stages of fibrosis. Transient elastography offered excellent diagnostic performance in assessing severe fibrosis and cirrhosis. Real-time elastography does not yet have the potential to substitute for transient elastography in the assessment of liver fibrosis.


Assuntos
Ácido Aspártico/sangue , Técnicas de Imagem por Elasticidade , Hepatite C Crônica/complicações , Cirrose Hepática/sangue , Cirrose Hepática/diagnóstico por imagem , Fígado/diagnóstico por imagem , Fígado/patologia , Adulto , Área Sob a Curva , Biópsia , Plaquetas/metabolismo , Progressão da Doença , Feminino , Seguimentos , Humanos , Cirrose Hepática/etiologia , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...