Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 91(2): 023510, 2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32113382

RESUMO

The requirements of ITER neutral beam injectors (1 MeV, 40 A negative deuterium ion current for 1 h) have never been simultaneously attained; therefore, a dedicated Neutral Beam Test Facility (NBTF) was set up at Consorzio RFX (Padova, Italy). The NBTF includes two experiments: SPIDER (Source for the Production of Ions of Deuterium Extracted from Rf plasma), the full-scale prototype of the source of ITER injectors, with a 100 keV accelerator, to investigate and optimize the properties of the ion source; and MITICA, the full-scale prototype of the entire injector, devoted to the issues related to the accelerator, including voltage holding at low gas pressure. The present paper gives an account of the status of the procurements, of the timeline, and of the voltage holding tests and experiments for MITICA. As for SPIDER, the first year of operation is described, regarding the solution of some issues connected with the radiofrequency power, the source operation, and the characterization of the first negative ion beam.

2.
Rev Sci Instrum ; 87(11): 11D433, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910628

RESUMO

The prototype radio frequency source of the ITER heating neutral beams will be first tested in SPIDER test facility to optimize H- production, cesium dynamics, and overall plasma characteristics. Several diagnostics will allow to fully characterise the beam in terms of uniformity and divergence and the source, besides supporting a safe and controlled operation. In particular, thermal measurements will be used for beam monitoring and system protection. SPIDER will be instrumented with mineral insulated cable thermocouples, both on the grids, on other components of the beam source, and on the rear side of the beam dump water cooled elements. This paper deals with the final design and the technical specification of the thermal sensor diagnostic for SPIDER. In particular the layout of the diagnostic, together with the sensors distribution in the different components, the cables routing and the conditioning and acquisition cubicles are described.

3.
Rev Sci Instrum ; 85(11): 11D832, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430245

RESUMO

A prototype system of the Langmuir probes for SPIDER (Source for the production of Ions of Deuterium Extracted from RF plasma) was manufactured and experimentally qualified. The diagnostic was operated in RF (Radio Frequency) plasmas with cesium evaporation on the BATMAN (BAvarian Test MAchine for Negative ions) test facility, which can provide plasma conditions as expected in the SPIDER source. A RF passive compensation circuit was realised to operate the Langmuir probes in RF plasmas. The sensors' holder, designed to better simulate the bias plate conditions in SPIDER, was exposed to a severe experimental campaign in BATMAN with cesium evaporation. No detrimental effect on the diagnostic due to cesium evaporation was found during the exposure to the BATMAN plasma and in particular the insulation of the electrodes was preserved. The paper presents the system prototype, the RF compensation circuit, the acquisition system (as foreseen in SPIDER), and the results obtained during the experimental campaigns.

4.
Rev Sci Instrum ; 85(2): 02A715, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593449

RESUMO

A system of electrostatic sensors has been designed for the SPIDER (Source for the production of Ions of Deuterium Extracted from RF plasma) experiment, prototype RF source of the ITER NBI (neutral beam injection). A prototype of the sensor system was manufactured and tested at the BATMAN (BAvarian Test MAchine for Negative ions) facility, where the plasma environment is similar to that of SPIDER. Different aspects concerning the mechanical manufacturing and the signal conditioning are presented, among them the RF compensation adopted to reduce the RF effects which could lead to overestimated values of the electron temperature. The first commissioning tests provided ion saturation current values in the range assumed for the design, so the deduced plasma density estimate is consistent with the expected values.

5.
Rev Sci Instrum ; 83(2): 02B103, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380260

RESUMO

The ITER heating neutral beam (HNB) injector, based on negative ions accelerated at 1 MV, will be tested and optimized in the SPIDER source and MITICA full injector prototypes, using a set of diagnostics not available on the ITER HNB. The RF source, where the H(-)∕D(-) production is enhanced by cesium evaporation, will be monitored with thermocouples, electrostatic probes, optical emission spectroscopy, cavity ring down, and laser absorption spectroscopy. The beam is analyzed by cooling water calorimetry, a short pulse instrumented calorimeter, beam emission spectroscopy, visible tomography, and neutron imaging. Design of the diagnostic systems is presented.

6.
Rev Sci Instrum ; 83(2): 02B724, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380329

RESUMO

In the development of the neutral beam injector for ITER experiment, the test facility SPIDER is going to be built. To measure the beam parameters, several diagnostics are used. One of them is the Short-Time Retractable Instrumented Kalorimeter Experiment (STRIKE) which measures beam uniformity, beamlet divergence, and stripping losses. This contribution gives an overview of the diagnostics dedicated to these measurements: thermal cameras, thermocouples, current sensors, and electrostatic sensors. The specifications of these diagnostics have been defined according to the results of electrostatic and thermal simulations. A failure modes and effects analysis has been performed during the design. Consequently the project of the STRIKE diagnostics has been optimized to reduce the possible failure risks.

7.
Rev Sci Instrum ; 83(2): 02B725, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380330

RESUMO

To study and optimise negative ion production for the ITER neutral beam injectors, a test facility is under construction in Padova with the aim of testing beam characteristics and to verify the source proper operation. The instrumented calorimeter STRIKE (short-time retractable instrumented kalorimeter experiment) is being developed to characterise the SPIDER (Source for Production of Ion of Deuterium Extracted from RF plasma) beam during short operations. The paper presents an investigation of the response of STRIKE measurement systems. It results that biasing is necessary to cope with the influence of secondary electrons on current measurements; moreover, despite the discretisation of the recorded thermal patterns introduced by the pixels of thermal cameras, a sufficient spatial resolution is expected.

8.
Phys Rev Lett ; 97(7): 075001, 2006 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-17026237

RESUMO

Stable operation with control on magnetohydrodynamic modes has been obtained in the modified reversed field experiment employing a set of 192 feedback controlled saddle coils. Improvements of plasma temperature, confinement (twofold), and pulse length (threefold) and, as a consequence of the magnetic fluctuation reduction, strong mitigation of plasma-wall interaction and mode locking are reported.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...