Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Anesthesiol ; 7: 2, 2007 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-17352800

RESUMO

BACKGROUND: We report a case of severe upper airway obstruction due to a retropharyngeal hematoma that presented nearly one day after a precipitating traumatic injury. Retropharyngeal hematomas are rare, but may cause life-threatening airway compromise. CASE PRESENTATION: A 50 year-old man developed severe dyspnea with oropharyngeal airway compression due to retropharyngeal hematoma 20 hours after presenting to the emergency department. The patient also had a fractured first cervical vertebra and was diagnosed with a left brachial plexopathy. The patient underwent emergent awake fiberoptic endotracheal intubation to provide a definitive airway. CONCLUSION: Retropharyngeal hematoma with life-threatening airway compromise can develop hours or days after a precipitating injury. Clinicians should be alert to the potential for this delayed airway collapse, and should also be prepared to rapidly secure the airway in this patient population likely to have concomitant cervical spinal or head injuries.

2.
Invest Radiol ; 41(2): 68-75, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16428975

RESUMO

RATIONALE AND OBJECTIVES: The objective of this study was to evaluate a 2-dimensional spoiled gradient echo (GRE) imaging approach using a very short in-phase TE for routine T1-weighted imaging of the brain at 3 T. MATERIALS AND METHODS: Patient examinations were compared from a 3 T magnetic resonance (MR) unit located immediately adjacent to a similarly equipped 1.5 T unit. Pre- and postcontrast T1-weighted images were evaluated and compared at 1.5 versus 3 T with a 2-dimensional (2-D) spin echo sequence used at 1.5 T and a 2-D GRE sequence at 3 T. The 2 MR systems used are from the same vendor, use similar 8-channel coils, and use identical gradients. The T1-weighted GRE sequence, used at 3 T, relies on a short TE (2.4 ms) to limit flow-related and susceptibility artifacts. Region-of-interest analysis was performed on 16 different sagittal patient examinations at both field strengths (32 total) and similarly on 10 different pre- and postcontrast axial examinations (40 total). Four blinded neuroradiologists also evaluated these studies. RESULTS: Using an off-midline sagittal slice depicting the caudate nucleus (signal-to-noise ratio [SNR] 163 +/- 28 vs. 70 +/- 7, 3 T vs. 1.5 T) and corona radiata (SNR 214 +/- 35 vs. 82 +/- 10), 3 T markedly outperformed 1.5 T in both SNR and contrast-to-noise ratio (CNR) (51 +/- 14 vs. 12 +/- 5). On axial imaging, despite a reduction in slice thickness (5 to 3 mm) and scan time (5 to 1 minute), there was no significant difference pre- or postcontrast in SNR and CNR comparing 3 and 1.5 T. On blinded film review, 3 T performed slightly better on sagittal scans than 1.5 T in regard to motion artifacts (reduced), gray-white matter differentiation, and overall image quality. On axial scans, 3 T performed markedly better in all 3 categories both pre- and postcontrast. In regard to overall image quality, 3 T was preferred 9:2 precontrast and 4:1 postcontrast. CONCLUSIONS: High-quality, thin-section (3-mm) T1-weighted imaging can be readily performed at 3 T using a short TE 2-D GRE technique. This approach offers superior SNR and CNR with reduced motion artifacts and scan time as compared with imaging at 1.5 T and is advocated for routine brain imaging at 3 T. It is robust (used in over 1500 patients to date) and does not experience significant specific absorption ratio limitations, poor tissue contrast, or accentuated motion artifacts like encountered with spin echo T1-weighted imaging at 3 T.


Assuntos
Encefalopatias/diagnóstico , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Artefatos , Encéfalo/patologia , Feminino , Humanos , Aumento da Imagem , Imageamento por Ressonância Magnética/instrumentação , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...