Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38728067

RESUMO

BACKGROUND: Lesion durability and transmurality are crucial for successful radiofrequency (RF) ablation. This study provides a model of real-time RF lesion visualization and insights into the role of underlying parameters, as local impedance (LI). METHODS: A force-sensing, LI-sensing catheter was used for lesion creation in an ex vivo model involving cross-sections of porcine cardiac preparations. During 60 s of RF application, one measurement per second was performed regarding lesion size and available ablation parameters. In total, 1847 measurements from n = 36 lesions were performed. Power (20-50 W) and contact force (1-5 g, 10-15 g, 20-25 g) were systematically alternated. RESULTS: Lesion formation was most prominent in the first seconds of RF application during which nonlinear lesion growth was observed (max. 1.08 mm/s for lesion depth and 2.71 mm/s for lesion diameter). Power levels determined the extent of lesion formation in the early phase. After 20 s, lesion size growth velocity approaches 0.1 mm/s at all power levels. LI changes were also highest in the first seconds (up to - 12 Ω/s) and decreased to less than - 0.1Ω/s after prolonged application. CONCLUSION: Lesion formation in irrigated RF ablation is a nonlinear process. Final lesion size resulting from an RF application is mainly influenced by high rates of lesion growth in the first seconds of ablation. LI seems to be a good surrogate for differentiating changes in lesion formation.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38819347

RESUMO

BACKGROUND: Catheter ablation for atrial fibrillation (AF) including pulmonary vein isolation and possibly further substrate ablation is the most common electrophysiological procedure. Severe complications are uncommon, but their detailed assessment in a large worldwide cohort is lacking. OBJECTIVES: The aim of this study was to determine the incidence of periprocedural severe complications and to provide a detailed characterization of the diagnostic evaluation and management of these complications in patients undergoing AF ablation. METHODS: Individual patient data were collected from 23 centers worldwide. Limited data were collected for all patients who underwent catheter ablation, and an expanded series of data points were collected for patients who experienced severe complications during periprocedural follow-up. Incidence, predictors, patient characteristics, management details, and overall outcomes of patients who experienced ablation-related complications were investigated. RESULTS: Data were collected from 23 participating centers at which 33,879 procedures were performed (median age 63 years, 30% women, 71% radiofrequency ablations). The incidence of severe complications (n = 271) was low (tamponade 6.8‰, stroke 0.97‰, cardiac arrest 0.41‰, esophageal fistula 0.21‰, and death 0.21‰). Age, female sex, a dilated left atrium, procedure duration, and the use of radiofrequency energy were independently associated with the composite endpoint of all severe complications. Among patients experiencing tamponade, 13% required cardiac surgery. Ninety-three percent of patients with complications were discharged directly home after a median length of stay of 5 days (Q1-Q3: 3-7 days). CONCLUSIONS: This large worldwide collaborative study highlighted that tamponade, stroke, cardiac arrest, esophageal fistula, and death are rare after AF ablation. Older age, female sex, procedure duration, a dilated left atrium, and the use of radiofrequency energy were associated with severe complications in this multinational cohort. One in 8 patients with tamponade required cardiac surgery.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38775921

RESUMO

BACKGROUND: Pulse field ablation (PFA) is a novel catheter ablation technology with potential safety benefits due to its tissue selectivity. It has the potential to directly damage or interact with the functionality of cardiac implantable electronic devices (CIEDs) in the form of electromagnetic interference (EMI). The aim of our study was to assess the impact of PFA on CIEDs. METHODS: PFA lesions (45 per CIED) were applied from the Farapulse system to CIEDs (< 5 cm from the lead tip and < 15 cm from the generator). All devices were checked before and after PFA application for proper sensing and pacing functionality as well as for integrity of shock circuits in ICDs using a heart simulator. Moreover, devices were then interrogated for any spontaneous reprogramming, mode switching or other EMI effects. RESULTS: In total, 44 CIEDs were tested (16 pacemaker, 21 ICDs, 7 CRT-P/D) with 1980 PFA applications. There was no change in device settings, functionality and electrical parameters, and there was no macroscopic damage to the devices. The risk of damage to the electric components or leads on a patient-based analysis is 0/44 (95% CI 0-8%) and on a PFA pulse-based analysis is 0/1980 (95% CI 0-0.2%). Clinically relevant EMI appeared with oversensing and pacing inhibition but not tachycardia detection. CONCLUSIONS: Bipolar PFA appears safe and does not result in damage to CIEDs or leads. Clinically relevant EMI does occur, but appropriate peri-procedural programming may mitigate this. In vivo studies are needed to confirm our findings.

5.
J Cardiovasc Electrophysiol ; 35(3): 406-414, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38197476

RESUMO

INTRODUCTION: Despite advanced ablation strategies and major technological improvements, treatment of persistent atrial fibrillation (AF) remains challenging and the underlying pathophysiology is not fully understood. This study analyzed the multiple procedure outcome and safety of catheter ablation of spatiotemporal dispersions (DISPERS) detected by artificial intelligence (AI)-guided software in patients with long-standing persistent AF. METHODS AND RESULTS: The Volta VX1 software was used for 50 consecutive patients undergoing catheter ablation for persistent AF. First, high-density mapping (78% biatrial) with a multipolar mapping catheter was performed. In addition to pulmonary vein isolation (PVI), ablation of DISPERS was performed aiming at homogenizing, dissecting, isolating, or connecting DISPERS areas to nonconducting anatomical structures. Follow-up contained regular visits at our outpatient clinic at 1, 3, 6, and 12 months including 7-day Holter electrocardiograms. Patients were mainly suffering from long-standing persistent AF (mean AF duration 50.30 ± 54.28 months). Following PVI, ablation of left atrial and right atrial DISPERS areas led to AF cycle length prolongation (mean of 162.0 ± 16.6 to 202.2 ± 21.6 ms after) and AF termination to atrial tachycardia (AT) or sinus rhythm (SR) in 12 patients (24%). No stroke or pericardial effusion occurred; major groin complications (pseudoaneurysm n = 1, atrioventricular fistula n = 1) were detected in two patients. After a blanking period of 6 weeks, recurrence of any atrial arrhythmia was documented in 26 patients (52%). The majority of patients presented with organized AT (n = 15) while AF was present in n = 9 patients and AT/AF was observed in n = 2 patients. Twenty-two patients underwent reablation. During a mean follow-up of 363.14 ± 187.42 days and after an average of 1.46 ± 0.68 procedures, 82% of patients remained in stable SR. CONCLUSION: DISPERS-guided ablation using machine learning software (the Volta VX1 software) in addition to PVI in long-standing persistent AF ablation resulted in high long-term success rates regarding AF and AT elimination. Most arrhythmia recurrences were reentrant AT. After a total of 1.46 ± 0.68 procedures, freedom from AF/AT was 82%. Despite prolonged procedure times complication rates were low. Randomized studies are necessary to evaluate long-term efficacy of dispersion-guided ablation using AI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Inteligência Artificial , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
6.
Clin Res Cardiol ; 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38261026

RESUMO

BACKGROUND: Data regarding uninterrupted oral anticoagulation in patients with chronic kidney disease (CKD) during catheter ablation for left atrial arrhythmias is limited. This study aimed to evaluate the safety and efficacy of periprocedural uninterrupted direct oral anticoagulants (DOAC) compared with uninterrupted phenprocoumon in patients with CKD undergoing left atrial catheter ablation. METHODS AND RESULTS: We conducted a retrospective single-center study of patients who underwent left atrial catheter ablation between 2016 and 2019 with underlying chronic kidney disease (glomerular filtration rate (GFR) between 15 and 45 ml/min). The primary objective of this study was to investigate whether direct oral anticoagulant (DOAC) therapy or warfarin presents a superior safety profile in patients with chronic kidney disease (CKD) undergoing left atrial catheter ablation. We compared periprocedural complications (arteriovenous fistula, aneurysm, significant hematoma (> 5 cm)) and/or bleeding (drop in hemoglobin of >2 g/dl, pericardial effusion, retroperitoneal bleeding, other bleeding, stroke) between patients receiving either uninterrupted DOAC or warfarin therapy. Secondary analysis included patient baseline characteristics as well as procedural data. A total of 188 patients (female n = 108 (57%), mean age 75.3 ± 8.1 years, mean GFR 36.8 ± 6 ml/min) were included in this study. Underlying arrhythmias were atrial fibrillation (n = 104, 55.3%) and atypical atrial flutter (n = 84, 44.7%). Of these, n = 132 patients (70%) were under a DOAC medication, and n = 56 (30%) were under phenprocoumon. Major groin complications including pseudoaneurysm and/or AV fistula occurred in 8.9% of patients in the phenprocoumon group vs. 11.3% of patients in the DOAC group, which was not statistically significant (p = 0.62). Incidence of cardiac tamponade (2.3% vs. 0%; p = 0.55) and stroke (0% vs. 0%) were low in both DOAC and phenprocoumon groups with similar post-procedural drops in hemoglobin levels (1.1±1 g/dl vs 1.1±0.9 g/dl; p = 0.71). CONCLUSION: The type of anticoagulation had no significant influence on bleeding or thromboembolic events as well as groin complications in this retrospective study. Despite observing an increased rate of groin complications, the uninterrupted use of DOAC or phenprocoumon during left atrial catheter ablation in patients with CKD appears to be feasible and effective.

7.
J Cardiovasc Electrophysiol ; 35(2): 317-327, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38105426

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is an established treatment strategy for atrial fibrillation (AF). To improve PVI efficacy and safety, high-power short-duration (HPSD) ablation and pulsed-field ablation (PFA) were recently introduced into clinical practice. This study aimed to determine the extent of myocardial injury and systemic inflammation following PFA, HPSD, and standard RFA using established biomarkers. METHODS: We included 179 patients with paroxysmal AF receiving first-time PVI with different ablation technologies: standard RFA (30-40 W/20-30 s, n = 52), power-controlled HPSD (70 W/5-7 s, n = 60), temperature-controlled HPSD (90 W/4 s, n = 32), and PFA (biphasic, bipolar waveform, n = 35). High-sensitivity cardiac troponin T (hs-cTnT), creatine kinase (CK), CK MB isoform (CK-MB), and white blood cell (WBC) count were determined before and after ablation. RESULTS: Baseline characteristics were well-balanced between groups (age 63.1 ± 10.3 years, 61.5% male). Postablation hs-cTnT release was significantly higher with PFA (1469.3 ± 495.0 ng/L), HPSD-70W (1322.3 ± 510.6 ng/L), and HPSD-90W (1441.2 ± 409.9 ng/L) than with standard RFA (1045.9 ± 369.7 ng/L; p < .001). CK and CK-MB release was increased with PFA by 3.4-fold and 5.8-fold, respectively, as compared to standard RFA (p < .001). PFA was associated with the lowest elevation in WBC (Δ1.5 ± 1.5 × 109 /L), as compared to standard RFA (Δ3.8 ± 2.5 × 109 /L, p < .001), HPSD-70W (Δ2.7 ± 1.7 × 109 /L, p = .037), and HPSD-90W (Δ3.6 ± 2.5 × 109 /L, p < .001). CONCLUSION: Among the four investigated ablation technologies, PFA was associated with the highest myocardial injury and the lowest inflammatory reaction.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Traumatismos Cardíacos , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Creatina Quinase Forma MB , Inflamação/diagnóstico , Veias Pulmonares/cirurgia , Troponina T , Ablação por Cateter/efeitos adversos , Resultado do Tratamento , Recidiva
9.
J Clin Med ; 12(20)2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37892670

RESUMO

BACKGROUND: The aim of this study was to assess long-term efficacy and safety of empirical slow pathway (ESP) ablation in pediatric and adult patients with a special interest in patients without dual AV nodal physiology (DAVNP). METHODS: A retrospective single-center review of patients who underwent ESP ablation between December 2014 and September 2022 was performed. Follow-up included telephone communication, letter questionnaire and outpatient presentation. Recurrence was based on typical symptoms. RESULTS: 115 patients aged 6-81 years (median age 36.3 years, 59.1% female; 26 pts < 18 years) were included. A typical history was present in all patients (100%), an ECG documentation of narrow complex tachycardia in 97 patients (84%). Patients were divided into three groups: Group 1 without DAVNP (n = 23), Group 2 with AH jump (n = 30) and Group 3 with AH jump and at least one AV nodal echo beat (n = 62). No permanent AV block was observed. During a median follow-up of 23.6 ± 22.7 months, symptom recurrence occurred in 7/115 patients (6.1%) with no significant difference between the groups (p = 0.73, log-rank test). Symptom recurrence occurred significantly more often in patients without (5/18 patients; 27%) as compared to patients with ECG documentation (2/97 patients; 2.1%; p = 0.025). No correlation between age and success rate was found (p > 0.1). CONCLUSIONS: ESP ablation is effective and safe in patients with non-inducible AVNRT. Overall, recurrence of symptoms during long-term follow-up is low, even if no DAVNP is present. Tachycardia documentation before the EP study leads to a significantly lower recurrence rate following ESP ablation.

10.
Pacing Clin Electrophysiol ; 46(10): 1170-1181, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37616376

RESUMO

BACKGROUND: The influence of power, duration and contact force (CF) on radiofrequency (RF) lesion formation is well known, whereas data on local impedance (LI) and electrode-tissue-coverage (ETC) is scarce. The objective was to investigate their effect on lesion formation in an ex vivo model. METHODS AND RESULTS: An ex vivo model was developed utilizing cross-sections of porcine heart preparations and a force-sensing, LI-measuring catheter. N = 72 lesion were created systematically varying ETC (minor/full), CF (1-5 g, 10-15 g, 20-25 g) and power (20 W, 30 W, 40 W, 50 W). In minor ETC, the distal tip of the catheter was in electric contact with the tissue, in full ETC the whole catheter tip was embedded within the tissue. Lesion size and all parameters were measured once per second (n = 3320). LI correlated strongly with lesion depth (r = -0.742 for ΔLI; r = 0.781 for %LI-drop). Lesions in full ETC were significantly wider and deeper compared to minor ETC (p < .001) and steam pops were more likely. Baseline LI, ΔLI, and %LI-drop were significantly higher in full ETC (p < .001). In lesions resulting in steam pops, baseline LI, and ΔLI were significantly higher. The influence of CF on lesion size was higher in minor ETC than in full ETC. CONCLUSIONS: ETC is a main determinant of lesion size and occurrence of steam pops. Baseline LI and LI-drop are useful surrogate parameters for real-time assessment of ETC and ΔLI correlates strongly with lesion size.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Impedância Elétrica , Ablação por Cateter/métodos , Eletrodos
11.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37067822

RESUMO

AIMS: Battery electric vehicle (BEV) sales and use are rapidly expanding. Battery electric vehicles, along with their charging stations, are a potential source of electromagnetic interference (EMI) for patients with cardiac implantable electronic devices (CIEDs). The new 'high-power' charging stations have the potential to create strong electromagnetic fields and induce EMI in CIEDs, and their safety has not been evaluated. METHODS AND RESULTS: A total of 130 CIED patients performed 561 charges of four BEVs and a test vehicle (350 kW charge capacity) using high-power charging stations under continuous 6-lead electrocardiogram monitoring. The charging cable was placed directly over the CIED, and devices were programmed to maximize the chance of EMI detection. Cardiac implantable electronic devices were re-interrogated after patients charged all BEVs and the test vehicle for evidence of EMI. There were no incidences of EMI, specifically no over-sensing, pacing inhibition, inappropriate tachycardia detection, mode switching, or spontaneous reprogramming. The risk of EMI on a patient-based analysis is 0/130 [95% confidence interval (CI) 0%-2%], and the risk of EMI on a charge-based analysis is 0/561 (95% CI 0%-0.6%). The effective magnetic field along the charging cable was 38.65 µT and at the charging station was 77.9 µT. CONCLUSIONS: The use of electric cars with high-power chargers by patients with cardiac devices appears to be safe with no evidence of clinically relevant EMI. Reasonable caution, by minimizing the time spent in close proximity with the charging cables, is still advised as the occurrence of very rare events cannot be excluded from our results.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Campos Eletromagnéticos/efeitos adversos , Fontes de Energia Elétrica , Coração
12.
Eur Heart J Case Rep ; 7(3): ytad118, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36969511

RESUMO

Background: Ventricular tachycardia (VT) originating in the right ventricular outflow tract (RVOT) is the most common form of idiopathic VT. Catheter ablation of right ventricular outflow tract tachycardia (RVOT-VT) is associated with high success rates. However, non-inducibility of VT on electrophysiological (EP) study can severely impact ablation outcome. We describe a novel catheter ablation strategy which proved feasible and safe in a case of highly symptomatic, non-inducible RVOT-VT. Case summary: A 51-year-old male with a history of non-sustained VT (NSVT) was referred to our hospital after two syncopal episodes resulting in collapse. Upon admission, a cluster of monomorphic NSVT (250-270 b.p.m.) resulted in haemodynamic instability and required transfer to the intensive care unit. On twelve-lead electrocardiogram, NSVT showed inferior axis and left bundle branch block, suggestive of RVOT-VT. Diagnostic workup including echocardiography, coronary angiography, and late enhancement computed tomography (CT) revealed no evidence of structural heart disease. On two EP studies, non-inducibility of clinical VT despite repeated ventricular pacing and isoproterenol infusion rendered precise mapping of triggered activity unfeasible. Therefore, a bailout ablation strategy was developed by performing a circumferential electrical RVOT isolation using a 3.5 mm irrigated-tip ablation catheter under the guidance of high-density electroanatomic mapping (CARTO® 3) and CT reconstruction of cardiac anatomy. No procedural complications occurred, and the patient remained arrhythmia-free during a 6-month follow-up period. Discussion: Catheter ablation is a first-line therapy for symptomatic and drug-refractory idiopathic RVOT-VT. Non-inducibility of RVOT-VT represents a relevant limitation for successful ablation which might be overcome by electrical RVOT isolation as a bailout ablation strategy.

13.
Europace ; 25(2): 408-416, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36504120

RESUMO

AIMS: This retrospective study sought to compare complication rates and efficacy of power-controlled very high-power short-duration (vHPSD) and conventional catheter ablation in a large cohort of patients with atrial fibrillation (AF). METHODS AND RESULTS: We analyzed 1115 consecutive patients with AF (38.7% paroxysmal, 61.3% persistent) who received first-time catheter ablation at our centre from 2015 to 2021. Circumferential pulmonary vein isolation ± additional substrate ablation using an irrigated-tip catheter was performed with vHPSD (70 W/5-7 s or 60 W/7-10 s) in 574 patients and with conventional power (30-35 W/15-30 s) in 541 patients. Baseline characteristics were well-balanced between groups (mean age 65.1 ± 11.2 years, 63.4% male). The 30-day incidence of cardiac tamponade [2/574 (0.35%) vs. 1/541 (0.18%), P = 0.598], pericardial effusion ≥ 10 mm [2/574 (0.35%) vs. 1/541 (0.18%), P = 0.598] and transient ischaemic attack [1/574 (0.17%) vs. 2/541 (0.37%), P = 0.529] was not significantly different between vHPSD and conventional ablation. No stroke, atrio-esophageal fistula, cardiac arrest or death occurred. Procedure (122.2 ± 46.8 min vs. 155.0 ± 50.5 min, P < 0.001), radiofrequency (22.4 ± 19.3 min vs. 52.9 ± 22.0 min, P < 0.001), and fluoroscopy (8.1 ± 7.2 vs. 9.2 ± 7.4, P = 0.016) duration were significantly shorter in the vHPSD group. At 12 months follow-up, freedom of any atrial arrhythmia was 44.1% vs. 34.2% (P = 0.010) in persistent AF and 78.1% vs. 70.2% in paroxysmal AF (P = 0.068). CONCLUSION: vHPSD ablation is as safe as conventional ablation and is associated with an improved long-term efficacy in persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Catéteres , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
14.
J Clin Med ; 11(22)2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36431243

RESUMO

Background: Femoral vascular access using the standard anatomic landmark-guided method is often limited by peripheral artery disease and obesity. We investigated the effect of ultrasound-guided vascular puncture (UGVP) on the rate of vascular complications in patients undergoing catheter ablation for atrial or ventricular arrhythmias. Methods: The data of 479 patients (59% male, mean age 68 years ± 11 years) undergoing catheter ablation for left atrial (n = 426; 89%), right atrial (n = 28; 6%) or ventricular arrhythmias (n = 28; 6%) were analyzed. All patients were on uninterrupted oral anticoagulants and heparin was administered intravenously during the procedure. Femoral access complications were compared between patients undergoing UGVP (n = 320; 67%) and patients undergoing a conventional approach (n = 159; 33%). Complication rates were also compared between patients with a BMI of >30 kg/m2 (n = 136) and patients with a BMI < 30 kg/m2 (n = 343). Results: Total vascular access complications including mild hematomas were n = 37 (7.7%). In the conventional group n = 17 (10.7%) and in the ultrasound (US) group n = 20 (6.3%) total vascular access complications occurred (OR 0.557, 95% CI 0.283−1.096). UGVP significantly reduced the risk of hematoma > 5 cm (OR 0.382, 95% CI 0.148, 0.988) or pseudoaneurysm (OR 0.160, 95% CI 0.032, 0.804). There was no significant difference between the groups regarding retroperitoneal hematomas or AV fistulas (p > 0.05). In patients with BMI > 30 kg/m2, UGVP led to a highly relevant reduction in the risk of total vascular access complications (OR 0.138, 95% CI 0.027, 0.659), hematomas > 5 cm (OR 0.051, 95% CI 0.000, 0.466) and pseudoaneurysms (OR 0.051, 95% CI 0.000, 0.466). Conclusion: UGVP significantly reduces vascular access complications. Patients with a BMI > 30 kg/m2 seem to particularly profit from a UGVP approach.

15.
Molecules ; 27(13)2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-35807311

RESUMO

Freshly harvested Boletus edulis mushrooms are subjected to rapid loss of quality due to the high moisture content and enzymatic activity. Drying time, quality characteristics, microstructural and thermal properties were studied in mushrooms ground to puree subjected to hot air drying (HAD), freeze drying (FD) and centrifugal vacuum drying (CVD). The influence of hot water blanching and UV-C pretreatments was additionally investigated. The rehydration ability of mushroom powders was improved by FD, especially without pretreatment or combined to UV-C exposure. The HAD and CVD, with no pretreatment or combined to UV-C, ensured good preservation of phenolics and antioxidant activity of dried mushrooms. The total difference in color of mushroom pigments extracted in acetone was lower in samples dried by CVD and higher in ones by FD. Blanching before HAD produced whiter product probably due to the reduced polyphenoloxidase activity. Scanning Electron Microscopy (SEM) analysis showed fewer physical changes in FD-samples. Heat-induced structural changes were noticed by Differential Scanning Calorimetry (DSC), Thermogravimetry (TG) and Derivative Thermogravimetry (DTG) analysis, in particular of biopolymers, confirmed by ATR-FTIR analysis. Based on our complex approach, the UV pretreatment of mushrooms could be a better alternative to water blanching. Centrifugal vacuum emerged as a new efficient drying method in terms of bioactive compounds, color and thermal stability, while FD led to better rehydration ability and microstructure.


Assuntos
Agaricales , Doenças Cardiovasculares , Antioxidantes/química , Basidiomycota , Dessecação/métodos , Liofilização , Vácuo , Água/química
16.
Heart Rhythm O2 ; 3(3): 288-294, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35734291

RESUMO

Background: Catheter ablation for atrial fibrillation (AF) or left atrial tachycardia is well established. To avoid body movement and pain, sedative and analgesic agents are used. Objective: The aim was to investigate safety of sedation/anti-pain protocol administered by electrophysiology (EP) staff. Methods: A total of 3211 consecutive patients (61% male) undergoing left atrial ablation for paroxysmal AF (37.1%), persistent AF (35.3%) or left atrial tachycardia (27.6%) were included. Midazolam, fentanyl, and propofol were administered by EP staff. In case of respiratory depression, endotracheal intubation (eIT) or noninvasive ventilation (NIV) was implemented. Risk factors for eIT or NIV were analyzed. Results: Mean doses of propofol, midazolam, and fentanyl were 33.7 ± 16.7 mg, 3 ± 11.1 mg, and 0.16 ± 2.2 mg, respectively. Norepinephrine was administered in 396 of 3211 patients (12.3%) because of blood pressure drop (mean arterial pressure <60 mm Hg). NIV was necessary in 47 patients (1.5%) and eIT in 1 patient (0.03%). Procedure duration, high body mass index (BMI), high CHADS2-VASC2 score, high age, low glomerular filtration rate, diabetes mellitus, and low baseline oxygen saturation were associated with NIV or eIT. The only independent predictor for NIV/eIT was high BMI (>30.1 ± 9.0 kg/m2). Therefore, patients with a BMI of ≥30 had a 40% higher risk for the need of NIV/eIT during the procedure in our study. Conclusion: Sedation/anti-pain control including midazolam, propofol, and fentanyl administered by EP staff is safe, with only 1.53% requirement of NIV/eIT. High BMI (>30 kg/m2) emerged as an independent predictor for eIT/NIV.

17.
Life (Basel) ; 12(2)2022 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-35207559

RESUMO

BACKGROUND: Bone impairment of multifactorial etiology is a common feature in inflammatory bowel disease (IBD). Body composition parameters, which might be selectively modified in these patients, are important determinants of bone strength. Our aim was to investigate the relationship between components of body composition and bone parameters in IBD patients. METHODS: This is a cross-sectional, retrospective study including 80 IBD patients (43 women, 37 men). Lumbar spine (LS), femoral neck (FN) and whole body DXA scans were performed to analyze regional bone mineral density (BMD), as well as body composition, including appendicular skeletal muscle mass index (ASMI), total and visceral fat mass (VAT). Trabecular bone score (TBS) was assessed using iNsight Software. RESULTS: Twenty (25%) IBD patients had inadequate LS-BMD z scores (<=-2DS). Lean mass (LM) was a significant determinant of LS-BMD, after adjusting for age, gender, BMI and fat mass (p < 0.01), while fat mass% remained associated with FN-BMD (p < 0.01). TBS correlated positively with BMI (r = 0.24, p < 0.05), LS-BMD (r = 0.56, p < 0.001), ASMI (r = 0.34, p < 0.001) and negatively with VAT/total fat% (r = -0.27, p < 0.05). Multivariate analysis showed that ASMI, LS-BMD (positively) and VAT/total fat% (negatively) were independently associated with TBS. CONCLUSIONS: In IBD patients, skeletal muscle mass and fat percentage and distribution are important factors associated with bone health.

18.
Pacing Clin Electrophysiol ; 45(3): 357-364, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35015906

RESUMO

BACKGROUND: In patients with persistent left superior vena cava (PLSVC) ablation procedures can be challenging. We sought to determine the feasibility and safety of left atrial ablations in patients with PLSVC, especially when PLSVC is unknown prior to the ablation procedure. METHODS AND RESULTS: In this retrospective analysis 15 adult patients (mean age 64.6 ± 14.5 years, 53.3% male) with PLSVC undergoing 27 ablation procedures for atrial fibrillation or left atrial flutter were included. In 5 (33.3%) patients PLSVC was only discovered during the procedure. Transseptal puncture (TSP) was declared "difficult" by the ablating physician in 13 of 27 (48.2%) procedures and was not successfully completed in the first attempt in two patients with known PLSVC. Once TSP was successfully completed, all relevant structures were reached both during mapping and ablation in all procedures independent of whether PLSVC was known prior to the procedure. One major complication (3.7%) occurred in 27 procedures in a patient with known PLSVC. In the patients with unknown PLSVC no complication occurred. CONCLUSION: In experienced hands, left atrial access and ablation in patients with PLSVC is feasible and safe, particularly with regard to patients in whom the PLSVC is unknown prior to the ablation procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veia Cava Superior Esquerda Persistente , Adulto , Idoso , Ablação por Cateter/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Veia Cava Superior/cirurgia
19.
Heart Rhythm ; 19(4): 648-655, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34958942

RESUMO

BACKGROUND: Catheter ablation in adult congenital heart disease (ACHD) patients is a critical treatment strategy for complex arrhythmias including atrial fibrillation (AF) and atrial tachycardia (AT). In addition to vitamin K antagonists (VKAs), direct oral anticoagulants (DOACs) are increasingly used in this patient population. OBJECTIVE: The purpose of this study was to assess the safety of catheter ablation in ACHD patients on uninterrupted oral anticoagulation with VKA or DOAC, examining thromboembolic, bleeding, and vascular access complications. METHODS: Retrospective analysis of 234 ACHD patients with simple (n = 83), moderate (n = 66), or complex (n = 85) CHD (mean age 46 years) undergoing 368 ablation procedures on uninterrupted oral anticoagulation with VKA (45.4%) or DOAC (54.6%) was undertaken. Arrhythmias were AF in 97, right AT in 181, left AT in 65, or a combination of AF and AT in 25. RESULTS: No thromboembolic complications occurred. Major complications occurred in 4 patients (1.1%; 1 VKA, 3 DOAC), including retroperitoneal hematoma in 2 and arteriovenous (AV) fistula requiring surgical treatment in 2. Minor bleeding or vascular access complications occurred in 46 cases (12.5%), including hematomas >5 cm in 26, AV fistulas (not requiring surgical intervention) in 13, and pseudoaneurysms in 7 (thrombin injection in 3/7). Overall, no significant difference was found between DOAC (14.9%) and VKA groups (12.0%; P = .411). CONCLUSION: Catheter ablation in ACHD patients on uninterrupted oral anticoagulation with VKA or DOAC is feasible and safe. No thromboembolic events occurred, and major bleeding or vascular access complications were rare. No significant differences regarding minor bleeding or vascular access complications between patients on DOAC or VKA were found.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias Congênitas , Administração Oral , Adulto , Anticoagulantes , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Thromb Haemost ; 122(4): 611-622, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34352896

RESUMO

ADAMTS13 (a disintegrin and metalloproteinase with a thrombospondin type 1 motif, member 13) is a zinc-containing metalloprotease also known as von Willebrand factor (vWF)-cleaving protease. Low ADAMTS13 plasma levels are associated with an increased risk of arterial thrombosis, including myocardial infarction and cerebrovascular disease. The expression and regulation of this metalloprotease in human endothelial cells have not been systematically investigated. In this study, we demonstrate that ADAMTS13 expression is inhibited by proinflammatory cytokines tumor necrosis factor-α and interferon-γ as well as by CD40 ligand, which was hitherto unknown. Factors protecting against atherosclerosis such as exposure to continuous unidirectional shear stress, interleukin-10, or different HMG-CoA reductase inhibitors like, e.g., simvastatin, atorvastatin, or rosuvastatin, did not influence ADAMTS13 expression. Unidirectional periodic orbital shear stress, mimicking oscillatory flow conditions found at atherosclerosis-prone arterial bifurcations, had also no effect. In contrast, a reciprocal correlation between ADAMTS13 and vWF expression in endothelial cells depending on the differentiation state was noted. ADAMTS13 abundance significantly rose on both the mRNA and intracellular protein level and also tethered to the endothelial glycocalyx with the degree of confluency while vWF protein levels were highest in proliferating cells but significantly decreased upon reaching confluence. This finding could explain the anti-inflammatory and antithrombotic phenotype of dormant endothelial cells mediated by contact inhibition.


Assuntos
Aterosclerose , Trombose , Fator de von Willebrand , Proteína ADAMTS13 , Aterosclerose/genética , Aterosclerose/metabolismo , Células Endoteliais/metabolismo , Humanos , Estresse Mecânico , Trombose/metabolismo , Fator de von Willebrand/genética , Fator de von Willebrand/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...