Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 10(1): 9403, 2020 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-32523010

RESUMO

This paper presents a study of noise in room-temperature THz radiometers that use THz-to-optical upconversion followed by optical detection of thermal radiation. Despite some undesired upconverted thermal noise, no noise is intrinsically introduced by efficient electro-optic modulation via a sum-frequency-generation process in high quality factor (Q) whispering-gallery mode (WGM) resonators. However, coherent and incoherent optical detection results in fundamentally different noise characteristics. The analysis shows that the upconversion receiver is quantum limited like conventional amplifiers and mixers, only when optical homodyne or heterodyne detection is performed. However, this type of receiver shows advantages as a THz photon counter, where counting is in the optical domain. Theoretical predictions show that upconversion-based room-temperature receivers can outperform state-of-the-art cooled and room-temperature THz receivers based on low-noise amplifiers and mixers, provided that a photon conversion efficiency greater than 1% is realized. Although the detection bandwidth is naturally narrow due to the highly resonant electro-optic modulator, it is not fundamentally limited and can be broadened by engineering selective optical coupling mechanisms to the resonator.

2.
IEEE Trans Microw Theory Tech ; 67(3): 1184-1196, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31749460

RESUMO

This paper presents an investigation of methods for improving homogeneity inside various dielectric phantoms situated in a 10.5 T human-sized MRI. The transmit B1 ( B 1 + ) field is excited with a quadrature fed circular patch-probe and a 12 element capacitively-loaded microstrip array. Both simulations and measurements show improved homogeneity in a cylindrical water phantom, an inhomogeneous phantom (pineapple), and a NIST standard phantom. The simulations are performed using a full-wave finite-difference time-domain solver (Sim4Life) in order to find the B 1 + field distribution and compared to the gradient recalled echo image and efficiency result. For additional field uniformity, the wall electromagnetic boundary conditions are modified with a passive quadrifilar helix. Finally, these methods are applied in simulation to head imaging of an anatomically correct human body model (Duke, IT'IS Virtual Population) showing improved homogeneity and specific absorption rate for various excitations.

3.
Rev Sci Instrum ; 84(3): 034704, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23556834

RESUMO

In this work we introduce a system for 2-port microwave calibration at millikelvin temperatures operating at the coldest stage of a dilution refrigerator by use of an adapted thru-reflect-line algorithm. We show that this can be an effective tool for characterizing common 50 Ω microwave components with better than 0.1 dB accuracy at temperatures that are relevant to many current experiments in superconducting quantum information.

4.
Rev Sci Instrum ; 82(6): 065106, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21721729

RESUMO

This article describes the theory and design of an ultra-low noise electronic readout circuit for use with room temperature video-rate terahertz imaging arrays. First, the noise characteristics of various imaging detectors, including low resistance bolometers and high resistance diodes are discussed. Theoretical approaches to white and 1/f noise mitigation are examined, and a corresponding low-noise readout circuit is designed, built, and tested. It is shown that the circuit is capable of achieving detector limited noise performance for use in room temperature terahertz imaging systems. A thorough noise analysis of the circuit provides the necessary information for applying the readout circuit to any type of imaging detector, and more generally, any measurement of small signals from various source impedances in the presence of white and 1/f noise. W-band measurements of an 8-element, high-resistance detector array, and a 32-element, low-resistance detector array demonstrate the usefulness of the readout circuit. Finally, recommended circuit configurations for various detectors in the literature are provided, with theoretical performance metrics summarized.

5.
IEEE Trans Image Process ; 17(12): 2465-75, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19004716

RESUMO

Terahertz imaging makes it possible to acquire images of objects concealed underneath clothing by measuring the radiometric temperatures of different objects on a human subject. The goal of this work is to automatically detect and segment concealed objects in broadband 0.1-1 THz images. Due to the inherent physical properties of passive terahertz imaging and associated hardware, images have poor contrast and low signal to noise ratio. Standard segmentation algorithms are unable to segment or detect concealed objects. Our approach relies on two stages. First, we remove the noise from the image using the anisotropic diffusion algorithm. We then detect the boundaries of the concealed objects. We use a mixture of Gaussian densities to model the distribution of the temperature inside the image. We then evolve curves along the isocontours of the image to identify the concealed objects. We have compared our approach with two state-of-the-art segmentation methods. Both methods fail to identify the concealed objects, while our method accurately detected the objects. In addition, our approach was more accurate than a state-of-the-art supervised image segmentation algorithm that required that the concealed objects be already identified. Our approach is completely unsupervised and could work in real-time on dedicated hardware.


Assuntos
Algoritmos , Inteligência Artificial , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Imagem Terahertz/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Appl Opt ; 47(30): 5604-15, 2008 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-18936808

RESUMO

This paper describes a calibrated broadband emitter for the millimeter-wave through terahertz frequency regime, called the aqueous blackbody calibration source. Due to its extremely high absorption, liquid water is chosen as the emitter on the basis of reciprocity. The water is constrained to a specific shape (an optical trap geometry) in an expanded polystyrene (EPS) container and maintained at a selected, uniform temperature. Uncertainty in the selected radiometric temperature due to the undesirable reflectance present at a water interface is minimized by the trap geometry, ensuring that radiation incident on the entrance aperture encounters a pair of s and a pair of p reflections at 45 degrees. For water reflectance R(w) of 40% at 45 degrees in W-band, this implies a theoretical effective aperture emissivity of (1-R(2)(ws)R(2)(wp))>98.8%. From W-band to 450 GHz, the maximum radiometric temperature uncertainty is +/-0.40 K, independent of water temperature. Uncertainty from 450 GHz to 1 THz is increased due to EPS scattering and absorption, resulting in a maximum uncertainty of -3 K at 1 THz.

7.
Phys Rev E Stat Nonlin Soft Matter Phys ; 76(1 Pt 2): 016604, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17677582

RESUMO

Phase resonances in transmission compound structures with subwavelength slits produce sharp dips in the transmission response. For all equal slits, the wavelengths of these sharp transmission minima can be varied by changing the width or the length of all the slits. In this paper we show that the width of the dip, i.e., the frequency range of minimum transmittance, can be controlled by making at least one slit different from the rest within a compound unit cell. In particular, we investigate the effect that a change in the dielectric filling, or in the length of a single slit, produces in the transmission response. We also analyze the scan angle behavior of these structures by means of band diagrams and compare them with previous results for all-equal slit structures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...