Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heart Vessels ; 27(2): 151-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21448677

RESUMO

We sought to explore the immediate clinical and angiographic results of the Titan(®) stent implantation in diabetic patients, as well as the major adverse cardiac events (MACE) at 6-month follow-up. We enrolled 156 consecutive diabetic patients admitted to undergo percutaneous intervention for at least one significant (50%) coronary lesion. All lesions were treated with the Titan(®) stent implantation according to the contemporary interventional techniques. Patients were prospectively followed-up for at least 6 months. The primary endpoint was MACE at 6-month follow-up [cardiac death, myocardial infarction (MI), or target lesion revascularization (TLR)]. Secondary endpoints included angiographic and clinical procedural success, in-hospital MACE, TLR at 6-month follow-up, and stent thrombosis. The mean age was 66.7 ± 9.6 years, (68.4% males). A total of 197 Titan(®) stents were implanted in 163 lesions. Direct stenting was performed in 45.2% of the cases. The mean stent diameter was 3.1 ± 0.61 mm, and the mean length was 18.0 ± 8.9 mm. Average stent deployment pressure was 13.9 ± 4.2 bars. Angiographic procedural success was achieved in 154 (98.7%) cases, and clinical procedural success was achieved in 153 (98.1%) cases. One patient developed in-hospital non-Q-wave MI following the procedure. Clinical follow-up was completed in 155 (99.4%) patients. Three patients (1.9%) died of a cardiac or unknown cause, and two (1.3%) developed MI. TLR was performed in 11 patients (7.1%). Cumulative MACE at 6-month follow-up occurred in 16 (10.3%) patients. No patient suffered stent thrombosis. Titan(®) stent implantation in diabetic patients achieves an excellent immediate clinical and angiographic outcome, with a low incidence of MACE at mid-term follow-up.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Angiopatias Diabéticas/terapia , Stents , Titânio , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Angiopatias Diabéticas/diagnóstico por imagem , Angiopatias Diabéticas/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/prevenção & controle , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Espanha/epidemiologia , Trombose/mortalidade , Fatores de Tempo , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 76(2): 281-7, 2010 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-20665878

RESUMO

OBJECTIVES: We sought to explore the immediate results of Titan2 stent implantation in small coronary arteries, as well as the incidence of major adverse cardiac events (MACE) at six months follow-up. BACKGROUND: The safety of Titan2 stent has been confirmed in several studies in real-life unselected populations. METHODS: We enrolled 311 consecutive patients admitted for percutaneous intervention for at least one significant (50%) de novo lesion in a native small coronary artery (2.0-2.75 mm). All lesions were treated with Titan2 stent implantation. Patients were prospectively followed up for at least six months. The primary endpoint was MACE at six months follow-up [death, myocardial infarction (MI), or target vessel revascularization (TVR)]. Secondary endpoints included angiographic and clinical procedural success, in-hospital MACE, target lesion revascularization (TLR) during follow-up, and stent thrombosis. RESULTS: The mean age was 67.3 +/- 10.9 years (65.9% males). A total of 356 Titan2 stents were implanted in 353 lesions. Angiographic and clinical procedural success was achieved in 344 (97.5%) patients. No case of in-hospital MACE or acute stent thrombosis was reported. Clinical follow-up was completed for an average of 8 +/- 2 months. Two patients (0.7%) died, and 6 (2.1%) developed MI. TLR was performed in 12 (4.2%) and TVR in 16 (5.5%) patients, all were clinically driven. Cumulative MACE occurred in 20 (6.9%) patients. One patient suffered subacute stent thrombosis, but no late stent thrombosis. CONCLUSIONS: Titan2 stent implantation in small coronary arteries achieves excellent immediate outcome, with a low incidence of MACE at mid-term follow-up.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Materiais Revestidos Biocompatíveis , Estenose Coronária/terapia , Stents , Titânio , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...