1.
Eur Radiol ; 30(2): 934-942, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31471752

RESUMO

OBJECTIVES: To evaluate the accuracy and clinical integrability of a comprehensive simulation tool to plan and predict radiofrequency ablation (RFA) zones in liver tumors. METHODS: Forty-five patients with 51 malignant hepatic lesions of different origins were included in a prospective multicenter trial. Prior to CT-guided RFA, all patients underwent multiphase CT which included acquisitions for the assessment of liver perfusion. These data were used to generate a 3D model of the liver. The intra-procedural position of the RFA probe was determined by CT and semi-automatically registered to the 3D model. Size and shape of the simulated ablation zones were compared with those of the thermal ablation zones segmented in contrast-enhanced CT images 1 month after RFA; procedure time was compared with a historical control group. RESULTS: Simulated and segmented ablation zone volumes showed a significant correlation (ρ = 0.59, p < 0.0001) and no significant bias (Wilcoxon's Z = 0.68, p = 0.25). Representative measures of ablation zone comparison were as follows: average surface deviation (absolute average error, AAE) with 3.4 ± 1.7 mm, Dice similarity coefficient 0.62 ± 0.14, sensitivity 0.70 ± 0.21, and positive predictive value 0.66 ± 0. There was a moderate positive correlation between AAE and duration of the ablation (∆t; r = 0.37, p = 0.008). After adjustments for inter-individual differences in ∆t, liver perfusion, and prior transarterial chemoembolization procedures, ∆t was an independent predictor of AAE (ß = 0.03 mm/min, p = 0.01). Compared with a historical control group, the simulation added 3.5 ± 1.9 min to the procedure. CONCLUSION: The validated simulation tool showed acceptable speed and accuracy in predicting the size and shape of hepatic RFA ablation zones. Further randomized controlled trials are needed to evaluate to what extent this tool might improve patient outcomes. KEY POINTS: • More reliable, patient-specific intra-procedural estimation of the induced RFA ablation zones in the liver may lead to better planning of the safety margins around tumors. • Dedicated real-time simulation software to predict RFA-induced ablation zones in patients with liver malignancies has shown acceptable agreement with the follow-up results in a first prospective multicenter trial suggesting a randomized controlled clinical trial to evaluate potential outcome benefit for patients.


Assuntos
Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/métodos , Neoplasias Hepáticas/cirurgia , Adolescente , Adulto , Idoso , Carcinoma Hepatocelular/patologia , Quimioembolização Terapêutica/métodos , Simulação por Computador , Feminino , Humanos , Fígado/patologia , Fígado/cirurgia , Neoplasias Hepáticas/patologia , Masculino , Margens de Excisão , Pessoa de Meia-Idade , Planejamento de Assistência ao Paciente , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
2.
Int J Comput Assist Radiol Surg ; 12(1): 59-68, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27538836

RESUMO

PURPOSE: Radiofrequency ablation (RFA) is one of the most popular and well-standardized minimally invasive cancer treatments (MICT) for liver tumours, employed where surgical resection has been contraindicated. Less-experienced interventional radiologists (IRs) require an appropriate planning tool for the treatment to help avoid incomplete treatment and so reduce the tumour recurrence risk. Although a few tools are available to predict the ablation lesion geometry, the process is computationally expensive. Also, in our implementation, a few patient-specific parameters are used to improve the accuracy of the lesion prediction. METHODS: Advanced heterogeneous computing using personal computers, incorporating the graphics processing unit (GPU) and the central processing unit (CPU), is proposed to predict the ablation lesion geometry. The most recent GPU technology is used to accelerate the finite element approximation of Penne's bioheat equation and a three state cell model. Patient-specific input parameters are used in the bioheat model to improve accuracy of the predicted lesion. RESULTS: A fast GPU-based RFA solver is developed to predict the lesion by doing most of the computational tasks in the GPU, while reserving the CPU for concurrent tasks such as lesion extraction based on the heat deposition at each finite element node. The solver takes less than 3 min for a treatment duration of 26 min. When the model receives patient-specific input parameters, the deviation between real and predicted lesion is below 3 mm. CONCLUSION: A multi-centre retrospective study indicates that the fast RFA solver is capable of providing the IR with the predicted lesion in the short time period before the intervention begins when the patient has been clinically prepared for the treatment.


Assuntos
Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/métodos , Gráficos por Computador , Neoplasias Hepáticas/cirurgia , Carcinoma Hepatocelular/diagnóstico por imagem , Simulação por Computador , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Procedimentos Cirúrgicos Minimamente Invasivos , Modelos Teóricos , Imagem de Perfusão , Estudos Retrospectivos , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X
3.
Eur J Haematol ; 80(1): 76-80, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18028435

RESUMO

OBJECTIVES: Although total splenectomy is able to reduce clinical symptoms in patients with hereditary spherocytosis (HS), splenectomized patients are at risk to develop overwhelming bacterial infections and, to a lesser extent, thromboembolic complications. In contrast, partial splenectomy or partial splenic embolization (PSE) may also decrease the rate of hemolytic complications while maintaining residual splenic function. The aim of this study was to investigate the benefit of PSE in children with moderate to severe HS. PATIENTS AND METHODS: We performed PSE via retrograde transfemoral access in eight children (four female, four male) with moderate to severe HS at a median age of 8 yr. HS-related complications before PSE included gallstones in six and aplastic crises in four children. One patient was transfusion-dependent. RESULTS: No acute side effects were seen during or after PSE. Median hemoglobin increased significantly from levels between 7.5 g/dL and 11.65 g/dL before PSE to levels between 8.4 g/dL and 13.35 g/dL after PSE (P = 0.012). Median splenic sizes before PSE ranged from 9.7 cm/m2 to 19.0 cm/m2 and significantly decreased to values between 4.4 cm/m2 and 15.65 cm/m2 during follow-up (P = 0.012). CONCLUSIONS: PSE appears to be a safe, effective and feasible treatment option for the management of children with moderate to severe HS.


Assuntos
Embolização Terapêutica/métodos , Esferocitose Hereditária/terapia , Baço , Criança , Pré-Escolar , Feminino , Testes Hematológicos , Hemoglobinas/análise , Humanos , Lactente , Masculino , Esplenectomia
4.
Eur Radiol ; 16(9): 2016-30, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16547709

RESUMO

In this review the technique, indication for and complications of percutaneous nephrostomy (PCN) and antegrade ureter stent insertion are described. In the majority of the cases PCN is performed to relieve urinary obstruction, which can be of benign or malignant nature. Another indication for PCN is for treatment of urinary fistulas. PCN can be performed under ultrasound and/or fluoroscopic guidance, with a success rate of more than 90%. The complication rate is approximately 10% for major and minor complications together and 4-5% for major complications only. Percutaneous antegrade double-J stent insertion usually is performed if retrograde ureter stenting has not been successful. However, especially in malignant obstructions, the success rate for antegrade stenting is higher than for retrograde transvesical double-J stent insertion. In the case of severe infection and bleeding after PCN JJ-stent insertion may be contraindicated so long as there is no sufficient concomitant drainage via a PCN . Lower urinary tract dysfunction should be excluded before stent placement. The complication rate is 2-4%. Consequent stent surveillance with regular stent exchange is mandatory.


Assuntos
Nefrostomia Percutânea/efeitos adversos , Nefrostomia Percutânea/métodos , Doenças Urológicas/cirurgia , Cateteres de Demora , Humanos , Nefrostomia Percutânea/instrumentação , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...