Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 65(2): 025001, 2020 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-31851947

RESUMO

Solid state photodetectors like silicon photomultipliers (SiPMs) are playing an important role in several fields of medical imaging, life sciences and high energy physics. They are able to sense optical photons with a single photon detection time precision below 100 ps, making them ideal candidates to read the photons generated by fast scintillators in time of flight positron emission tomography (TOF-PET). By implementing novel high-frequency readout electronics, it is possible to perform a completely new evaluation of the best timing performance achievable with state-of-the-art analog-SiPMs and scintillation materials. The intrinsic SiPM single photon time resolution (SPTR) was measured with Ketek, HPK, FBK, SensL and Broadcom devices. Also, the best achieved coincidence time resolution (CTR) for these devices was measured with LSO:Ce:Ca of [Formula: see text] mm3 and [Formula: see text] mm3 size crystals. The intrinsic SPTR for all devices ranges between 70 ps and 135 ps FWHM when illuminating the entire [Formula: see text] mm2 or [Formula: see text] mm2 area. The obtained CTR with LSO:Ce:Ca of [Formula: see text] mm3 size ranges between 58 ps and 76 ps FWHM for the SiPMs evaluated. Bismuth Germanate (BGO), read out with state of-the-art NUV-HD SiPMs from FBK, achieved a CTR of 158 [Formula: see text] ps and 277 [Formula: see text] ps FWHM for [Formula: see text] mm3 and [Formula: see text] mm3 crystals, respectively. Other BGO geometries yielded 167 [Formula: see text] 3 ps FWHM for [Formula: see text] mm3 and 235 [Formula: see text] 5 ps FWHM for [Formula: see text] mm3 also coupled with Meltmount (n = 1.582) and wrapped in Teflon. Additionally, the average number of Cherenkov photons produced by BGO in each 511 keV event was measured to be 17 [Formula: see text] 3 photons. Based on this measurement, we predict the limits of BGO for ultrafast timing in TOF-PET with Monte Carlo simulations. Plastic scintillators (BC422, BC418), BaF2, GAGG:Ce codoped with Mg and CsI:undoped were also tested for TOF performance. Indeed, BC422 can achieve a CTR of 35 [Formula: see text] 2 ps FWHM using only Compton interactions in the detector with a maximum deposited energy of 340 keV. BaF2 with its fast cross-luminescence enables a CTR of 51 [Formula: see text] 5 ps FWHM when coupled to VUV-HD SiPMs from FBK, with only ∼22% photon detection efficiency (PDE). We summarize the measured CTR of the various scintillators and discuss their intrinsic timing performance.


Assuntos
Fótons , Tomografia por Emissão de Pósitrons/instrumentação , Contagem de Cintilação/instrumentação , Silício , Bismuto , Germânio , Método de Monte Carlo , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...