Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 282
Filtrar
1.
AJNR Am J Neuroradiol ; 43(8): 1142-1147, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35902121

RESUMO

BACKGROUND AND PURPOSE: Skull base tumors are commonly supplied by dural branches of the meningohypophyseal and inferolateral trunks. Embolization through these arteries is often avoided due to technical challenges and inherent risks; however, successful embolization can be a valuable surgical adjunct. We aimed to review the success and complications in our series of tumor embolizations through the meningohypophyseal and inferolateral trunks. MATERIALS AND METHODS: We performed a retrospective review of patients with tumor treated with preoperative embolization at our institution between 2010 and 2020. We reviewed the following data: patients' demographics, tumor characteristics, endovascular embolization variables, and surgical results including estimated blood loss, the need for transfusion, and operative time. RESULTS: Among 155 tumor embolization cases, we identified 14 patients in whom tumor embolization was performed using the meningohypophyseal (n = 13) or inferolateral (n = 4) trunk. In this group of patients, on average, 79% of tumors were embolized. No mortality or morbidity from the embolization procedure was observed in this subgroup of patients. The average estimated blood loss in the operation was 395 mL (range, 200-750 mL). None of the patients required a transfusion, and the average operative time was 7.3 hours. CONCLUSIONS: Some skull base tumors necessitate embolization through ICA branches such as the meningohypophyseal and inferolateral trunks. Our series demonstrates that an effective and safe embolization may be performed through these routes.


Assuntos
Embolização Terapêutica , Neoplasias da Base do Crânio , Humanos , Artérias , Embolização Terapêutica/métodos , Cuidados Pré-Operatórios/métodos , Estudos Retrospectivos , Neoplasias da Base do Crânio/diagnóstico por imagem , Neoplasias da Base do Crânio/terapia
2.
AJNR Am J Neuroradiol ; 42(10): 1827-1833, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34385140

RESUMO

BACKGROUND: Experience with endoluminal flow diversion for the treatment of posterior circulation aneurysms is limited. PURPOSE: We sought to investigate factors associated with the safety and efficacy of this treatment by collecting disaggregated patient-level data from the literature. DATA SOURCES: PubMed, EMBASE, and Ovid were searched up through 2019 for articles reporting flow diversion of posterior circulation aneurysms. STUDY SELECTION: Eighty-four studies reported disaggregated data for 301 separate posterior circulation aneurysms. DATA ANALYSIS: Patient, aneurysm, and treatment factors were collected for each patient. Outcomes included the occurrence of major complications, angiographic occlusion, and functional outcomes based on the mRS. DATA SYNTHESIS: Significant differences in aneurysm and treatment characteristics were seen among different locations. Major complications occurred in 22%, angiographic occlusion was reported in 65% (11.3 months of mean follow-up), and good functional outcomes (mRS 0-2) were achieved in 67% (13.3 months of mean follow-up). Multivariate analysis identified age, number of flow diverters used, size, and prior treatment to be associated with outcome measures. Meta-analysis combining the current study with prior large nondisaggregated series of posterior circulation aneurysms treated with flow diversion found a pooled incidence of 20% (n = 712 patients) major complications and 75% (n = 581 patients) angiographic occlusions. LIMITATIONS: This study design is susceptible to publication bias. Use of antiplatelet therapy was not uniformly reported. CONCLUSIONS: Endoluminal flow diversion is an important tool in the treatment of posterior circulation aneurysms. Patient age, aneurysm size, prior treatment, and the number of flow diverters used are important factors associated with complications and outcomes.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Aneurisma Roto/terapia , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Stents , Resultado do Tratamento
3.
AJNR Am J Neuroradiol ; 42(7): 1264-1269, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34255736

RESUMO

BACKGROUND AND PURPOSE: Published data regarding embolic protection device efficacy is mixed, and its use during carotid artery stent placement remains variable. We, therefore, examined the frequency of embolic protection device use and its association with outcomes after carotid artery stent placement using a national quality improvement data base. MATERIALS AND METHODS: Patients undergoing carotid artery stent placement with or without embolic protection devices were identified in the American College of Surgeons National Surgical Quality Improvement Program data base. The primary outcome was the incidence of major adverse cardiovascular events (defined as death, stroke, or myocardial infarction/arrhythmia) within 30 days. Propensity scoring was used to create 2 matching cohorts of patients using demographic and baseline variables. RESULTS: Between 2011 and 2018, among 1200 adult patients undergoing carotid artery stent placement, 23.8% did not have embolic protection devices. There was no trend toward increased embolic protection device use with time. Patients without embolic protection device use received preoperative antiplatelets less frequently (90.6% versus 94.6%, P = .02), underwent more emergent carotid artery stent placement (7.2% versus 3.6%, P = .01), and had a higher incidence of major adverse cardiovascular events (OR = 1.81; 95% CI, 1.11-2.94) and stroke (OR = 3.31; 95% CI, 1.71-6.39). After compensating for baseline imbalances using propensity-matched cohorts (n = 261 for both), carotid artery stent placement without an embolic protection device remained associated with increased major adverse cardiovascular events (9.2% versus 4.2%; OR = 2.30; 95% CI, 1.10-4.80) and stroke (6.5% versus 1.5%; OR = 4.48; 95% CI, 1.49-13.49). CONCLUSIONS: Lack of embolic protection device use during carotid artery stent placement is associated with a 4-fold increase in the likelihood of perioperative stroke. Nevertheless, nearly one-quarter of patients in the American College of Surgeons National Surgical Quality Improvement Program underwent unprotected carotid artery stent placement. Efforts targeting improved embolic protection device use during carotid artery stent placement are warranted.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Artérias Carótidas/cirurgia , Estenose das Carótidas , Dispositivos de Proteção Embólica , Embolia/prevenção & controle , Acidente Vascular Cerebral , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/prevenção & controle , Estenose das Carótidas/cirurgia , Bases de Dados Factuais , Embolia/etiologia , Humanos , Stents/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
4.
AJNR Am J Neuroradiol ; 42(7): 1258-1263, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33888454

RESUMO

BACKGROUND AND PURPOSE: Acute stroke intervention refractory to mechanical thrombectomy may be due to underlying vessel wall pathology including intracranial atherosclerotic disease and intracranial arterial dissection or recalcitrant emboli. We studied the prevalence and etiology of refractory thrombectomy, the safety and efficacy of adjunctive interventions in a North American-based cohort. MATERIALS AND METHODS: We performed a multicenter, retrospective study of refractory thrombectomy, defined as unsuccessful recanalization, vessel reocclusion in <72 hours, or required adjunctive antiplatelet glycoprotein IIb/IIIa inhibitors, intracranial angioplasty and/or stenting to achieve and maintain reperfusion. Clinical and imaging criteria differentiated etiologies for refractory thrombectomy. Baseline demographics, cerebrovascular risk factors, technical/clinical outcomes, and procedural safety/complications were compared between refractory and standard thrombectomy groups. Multivariable logistic regression analysis was performed to determine independent predictors of refractory thrombectomy. RESULTS: Refractory thrombectomy was identified in 25/302 cases (8.3%), correlated with diabetes (44% versus 22%, P = .02) as an independent predictor with OR = 2.72 (95% CI, 1.05-7.09; P = .04) and inversely correlated with atrial fibrillation (16% versus 45.7%, P = .005). Refractory etiologies were secondary to recalcitrant emboli (20%), intracranial atherosclerotic disease (60%), and/or intracranial arterial dissection (44%). Four (16%) patients were diagnosed with early vessel reocclusion, and 21 patients underwent adjunctive salvage interventions with glycoprotein IIb/IIIa inhibitor infusion alone (32%) or intracranial angioplasty and/or stenting (52%). There were no significant differences in TICI 2b/3 reperfusion efficacy (85.7% versus 90.9%, P = .48), symptomatic intracranial hemorrhage rates (0% versus 9%, P = .24), favorable clinical outcomes (39.1% versus 48.3%, P = .51), or mortality (13% versus 28.3%, P = .14) versus standard thrombectomy. CONCLUSIONS: Refractory stroke thrombectomy is encountered in <10% of cases, independently associated with diabetes, and related to underlying vessel wall pathology (intracranial atherosclerotic disease and/or intracranial arterial dissection) or, less commonly, recalcitrant emboli. Emergent salvage interventions with glycoprotein IIb/IIIa inhibitors or intracranial angioplasty and/or stenting are safe and effective adjunctive treatments.


Assuntos
Acidente Vascular Cerebral , Trombectomia , Angioplastia , Humanos , América do Norte/epidemiologia , Inibidores da Agregação Plaquetária/uso terapêutico , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Prevalência , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/terapia , Trombectomia/efeitos adversos , Trombectomia/estatística & dados numéricos , Falha de Tratamento , Resultado do Tratamento
5.
J Environ Manage ; 250: 109366, 2019 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-31494409

RESUMO

Diffuse pollution from agriculture constitutes a key pressure on the water quality of freshwaters and is frequently the cause of ecological degradation. The problem of diffuse pollution can be conceptualised with a source-mobilisation-pathway (or delivery)-impact model, whereby the combination of high source risk and strong connected pathways leads to 'critical source areas' (CSAs). These areas are where most diffuse pollution will originate, and hence are the optimal places to implement mitigation measures. However, identifying the locations of these areas is a key problem across different spatial scales within catchments. A number of approaches are frequently used for this assessment, although comparisons of these assessments are rarely carried out. We evaluate the CSAs identified via traditional walkover surveys supported by three different approaches, highlighting their benefits and disadvantages. These include a custom designed smartphone app; a desktop geographic information system (GIS) and terrain analysis-based SCIMAP (Sensitive Catchment Integrated Modelling and Analysis Platform) approach; and the use of a high spatial resolution drone dataset as an improved input data for SCIMAP modelling. Each of these methods captures the locations of the CSAs, revealing similarities and differences in the prioritisation of CSA features. The differences are due to the temporal and spatial resolution of the three methods such as the use of static land cover information, the ability to capture small scale features, such as gateways and the incomplete catchment coverage of the walkover survey. The relative costs and output resolutions of the three methods indicate that they are suitable for application at different catchment scales in conjunction with other methods. Based on the results in this paper, it is recommended that a multi-evidence-based approach to diffuse pollution management is taken across catchment spatial scales, incorporating local knowledge from the walkover with the different data resolutions of the SCIMAP approach.


Assuntos
Agricultura , Qualidade da Água , Monitoramento Ambiental , Água Doce , Sistemas de Informação Geográfica , Poluição da Água
6.
AJNR Am J Neuroradiol ; 40(8): 1356-1362, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31345939

RESUMO

BACKGROUND AND PURPOSE: Adjunctive techniques to stent retriever thrombectomy include balloon-guide catheters and/or distal access catheters for aspiration. We describe a novel technique using a flexible, 6 French 088 distal guide sheath advanced past the skull base to augment mechanical thrombectomy. We studied the relative safety and efficacy of this technique in the setting of a combined stent retriever-distal access catheter aspiration thrombectomy protocol. MATERIALS AND METHODS: We performed a retrospective case-control study of intracranial internal carotid artery or M1-M2 middle cerebral artery occlusions requiring mechanical thrombectomy. Patients were divided into 2 groups based on thrombectomy techniques: conventional stent retriever with distal access catheter aspiration without (standard) and with adjunctive GUide sheath Advancement and aspiRation in the Distal petrocavernous internal carotid artery (GUARD). Using propensity score matching, we compared procedural safety, reperfusion efficacy using the modified Thrombolysis in Cerebral Infarction scale and clinical outcomes with the modified Rankin Scale. RESULTS: In comparing the GUARD (45 patients) versus standard (45 matched case controls) groups, there were no significant differences in demographics, NIHSS presentations, IV rtPA use, median onset-to-groin puncture times, procedural complications, symptomatic intracranial hemorrhage, or mortality. The GUARD group demonstrated significantly higher successful mTICI ≥2b reperfusion rates (98% versus 80%, P = .015) and improved functional mRS ≤2 outcomes (67% versus 43%, P = .04), with independent effects of the GUARD technique confirmed in a multivariable logistic regression model. CONCLUSIONS: The GUARD technique during mechanical thrombectomy with combined stent retrieval-distal access catheter aspiration is safe and effective in improving reperfusion and clinical outcomes.


Assuntos
Infarto da Artéria Cerebral Média/cirurgia , Reperfusão/métodos , Trombectomia/instrumentação , Trombectomia/métodos , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
7.
AJNR Am J Neuroradiol ; 40(6): 954-959, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31072969

RESUMO

BACKGROUND AND PURPOSE: 3D high-resolution black-blood MRI or MR vessel wall imaging allows evaluation of the intracranial arterial wall and extraluminal pathology. We investigated the diagnostic accuracy and reliability of black-blood MRI for the intraluminal detection of large-vessel arterial occlusions. MATERIALS AND METHODS: We retrospectively identified patients with intracranial arterial occlusions, confirmed by CTA or DSA, who also underwent 3D black-blood MRI with nonenhanced and contrast-enhanced T1 sampling perfection with application-optimized contrasts by using different flip angle evolution (T1 SPACE) sequences. Black-blood MRI findings were evaluated by 2 independent and blinded neuroradiologists. Large-vessel intracranial arterial segments were graded on a 3-point scale (grades 0-2) for intraluminal baseline T1 hyperintensity and contrast enhancement. Vessel segments were considered positive for arterial occlusion if focal weak (grade 1) or strong (grade 2) T1-hyperintense signal and/or enhancement replaced the normal intraluminal black-blood signal. RESULTS: Thirty-one patients with 38 intracranial arterial occlusions were studied. The median time interval between black-blood MRI and CTA/DSA reference standard studies was 2 days (range, 0-20 days). Interobserver agreement was good for T1 hyperintensity (κ = 0.63) and excellent for contrast enhancement (κ = 0.89). High sensitivity (100%) and specificity (99.8%) for intracranial arterial occlusion diagnosis was observed with either intraluminal T1 hyperintensity or contrast-enhancement imaging criteria on black-blood MRI. Strong grade 2 intraluminal enhancement was maintained in >80% of occlusions irrespective of location or chronicity. Relatively increased strong grade 2 intraluminal T1 hyperintensity was noted in chronic/incidental versus acute/subacute occlusions (45.5% versus 12.5%, P = .04). CONCLUSIONS: Black-blood MRI with or without contrast has high diagnostic accuracy and reliability in evaluating intracranial large-vessel arterial occlusions with near-equivalency to DSA and CTA.


Assuntos
Transtornos Cerebrovasculares/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Adulto , Idoso , Transtornos Cerebrovasculares/complicações , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Acidente Vascular Cerebral/etiologia
8.
Conserv Biol ; 33(5): 1014-1022, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30815912

RESUMO

Leading societies toward a more sustainable, equitably shared, and environmentally just future requires elevating and strengthening conversations on the nonmaterial and perhaps unquantifiable values of nonhuman nature to humanity. Debates among conservationists relating to the appropriateness of valuing ecosystems in terms of their human utility have eclipsed the more important and impactful task of expressing conservation concerns in terms that are meaningful to diverse stakeholders. We considered the wide global diversity of perspectives on the biosocial complex-the relationships and interactions between all living species on Earth-and argue that humanity's best chance for effective conservation is to take a pluralistic approach that engages seriously with the worldviews of all stakeholders. Many worldviews-particularly those in indigenous cultures-place a higher value on the spiritual and nonmaterial aspects than what is often represented by the discourse surrounding Western conservation policy. Alternative framings of the biosocial complex that recognize nature's intrinsic value can be powerful motivators for social change and for local-scale conservation efforts. At a national and international level, changing ethical framings of human relationships with nature have started influencing conceptions of human rights relating to the environment and of the rights of nature itself. This change has led to an increased role of the judiciary in promoting environmental sustainability and promoting justice for groups who are most often affected by environmental harms. We hope our essay will motivate the scientific community to change its own perception of what a sound and sustainable relationship between humanity and other species should be and will help citizens become active environmental subjects, connected to the ecosystems around them.


Adopción de Diferentes Cosmovisiones para Compartir el Planeta Tierra Resumen Para poder llevar a las sociedades hacia un futuro sustentable, compartido equitativa y ambientalmente justo se requiere elevar y fortalecer las conversaciones sobre los valores no materiales y probablemente imposibles de cuantificar que la naturaleza no humana tiene para la humanidad. Los debates entre los conservacionistas en relación con lo apropiado que es valorar los ecosistemas en términos de utilidad para los humanos han eclipsado la labor más importante e impactante de expresar los asuntos de conservación en términos que son significativos para diferentes accionistas. Consideramos la amplia diversidad mundial de perspectivas que existen sobre el complejo biosocial - las relaciones e interacciones entre todas las especies vivientes en la Tierra - y argumentamos que la mejor oportunidad que tiene la humanidad para lograr una conservación efectiva es realizar una estrategia pluralística que se comprometa seriamente con las cosmovisiones de todos los accionistas. Muchas cosmovisiones - particularmente aquellas de las culturas indígenas - les otorgan un valor más alto a los aspectos espirituales y no materiales que lo que se suele representar en el discurso que rodea la política de conservación occidental. Los marcos alternativos del complejo biosocial que reconocen el valor intrínseco de la naturaleza pueden ser motivadores poderosos para el cambio social y para los esfuerzos de conservación a escala local. A nivel nacional e internacional, el cambio de los marcos éticos de las relaciones humanas con la naturaleza ha comenzado a influenciar las concepciones de los derechos humanos en relación con el ambiente y los derechos de la naturaleza misma. Este cambio ha resultado en un papel mucho mayor del poder judicial en la promoción de la sustentabilidad ambiental y de la justicia para grupos a los que con frecuencia les afectan los daños ambientales. Esperamos que nuestro ensayo motive a la comunidad científica a cambiar su propia percepción de lo que debe ser una relación sana y sustentable entre la humanidad y otras especies y que ayude a los ciudadanos a volverse sujetos ambientales más activos y conectados con el ecosistema.


Assuntos
Conservação dos Recursos Naturais , Ecossistema , Planeta Terra , Humanos , Justiça Social
9.
AJNR Am J Neuroradiol ; 39(9): 1689-1695, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30093482

RESUMO

BACKGROUND AND PURPOSE: Micro-arteriovenous malformations are an underrecognized etiology of intracranial hemorrhage. Our study aimed to assess the adjunctive efficacy of intra-arterial conebeam CTA relative to DSA in the diagnosis and surgical planning of intracranial micro-AVMs. MATERIALS AND METHODS: We performed a retrospective study of all micro-AVMs (≤1-cm nidus) at our institution. Blinded neuroradiologists qualitatively graded DSA and intra-arterial conebeam CTA images for the detection of specific micro-AVM anatomic parameters (arterial feeder, micronidus, and venous drainer) and defined an overall diagnostic value. Statistical and absolute differences in the overall diagnostic values defined the relative intra-arterial conebeam CTA diagnostic values, respectively. Blinded neurosurgeons reported their treatment approach after DSA and graded the adjunctive value of intra-arterial conebeam CTA to improve or modify treatment. Intra-arterial conebeam CTA efficacy was defined as interobserver agreement in the relative intra-arterial conebeam CTA diagnostic and/or treatment-planning value scores. RESULTS: Ten patients with micro-AVMs presented with neurologic deficits and/or intracranial hemorrhages. Both neuroradiologists assigned a higher overall intra-arterial conebeam CTA diagnostic value (P < .05), secondary to improved evaluation of both arterial feeders and the micronidus, with good interobserver agreement (τ = 0.66, P = .018) in the relative intra-arterial conebeam CTA diagnostic value. Both neurosurgeons reported that integrating the intra-arterial conebeam CTA data into their treatment plan would allow more confident localization for surgical/radiation treatment (8/10; altering the treatment plan in 1 patient), with good interobserver agreement in the relative intra-arterial conebeam CTA treatment planning value (τ = 0.73, P = .025). CONCLUSIONS: Adjunctive intra-arterial conebeam CTA techniques are more effective in the diagnostic identification and anatomic delineation of micro-AVMs, relative to DSA alone, with the potential to improve microsurgical or radiosurgery treatment planning.


Assuntos
Angiografia Digital/métodos , Angiografia por Tomografia Computadorizada/métodos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Feminino , Humanos , Malformações Arteriovenosas Intracranianas/cirurgia , Masculino , Pessoa de Meia-Idade , Radiocirurgia , Estudos Retrospectivos
10.
J Environ Manage ; 209: 17-22, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29275281

RESUMO

Food, energy, and water (FEW) systems are inexorably linked. Earth's changing climate and increasing competition for finite land resources are creating and amplifying challenges at the FEW nexus. Managing FEW systems to mitigate these negative impacts and stresses is a pressing policy issue. The FEW interface is often managed as three independent systems, missing disruptive opportunities for streamlined integrated management. We contend that existing technologies can be reframed and emerging technologies can be harnessed for integrated FEW management, changing the way that each resource system operates within the broader system. We discuss solutions to three main challenges to integrating FEW system management: resolving spatiotemporal disconnections over multiple scales; closing resource loops; and creating actionable information. Sustainable resource management is critical for humanity, as well as for functioning trade systems and ecological health. Embracing integrated management in FEW systems would enable policy makers and managers to more efficiently and effectively secure critical resource systems in the face of global change.


Assuntos
Conservação dos Recursos Naturais , Abastecimento de Alimentos , Água , Ecologia , Alimentos
11.
AJNR Am J Neuroradiol ; 38(1): 97-104, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28059705

RESUMO

BACKGROUND AND PURPOSE: Although most cervical dissections are managed medically, emergent endovascular treatment may become necessary in the presence of intracranial large-vessel occlusions, flow-limiting and long-segment dissections with impending occlusion, and/or hypoperfusion-related ischemia at risk of infarction. We investigated the role of emergent endovascular stenting of long-segment carotid dissections in the acute ischemic stroke setting. MATERIALS AND METHODS: We retrospectively studied long-segment carotid dissections requiring stent reconstruction with multiple tandem stents (≥3 stents) and presenting with acute (<12 hours) ischemic stroke symptoms (NIHSS score, ≥4). We analyzed patient demographics, vascular risk factors, clinical presentations, imaging/angiographic findings, technical procedures/complications, and clinical outcomes. RESULTS: Fifteen patients (mean age, 51.5 years) with acute ischemic stroke (mean NIHSS score, 15) underwent endovascular stent reconstruction for vessel and/or ischemic tissue salvage. All carotid dissections presented with >70% flow limiting stenosis and involved the distal cervical ICA with a minimum length of 3.5 cm. Carotid stent reconstruction was successful in all patients with no residual stenosis or flow limitation. Nine patients (60%) harbored intracranial occlusions, and 6 patients (40%) required intra-arterial thrombolysis/thrombectomy, achieving 100% TICI 2b-3 reperfusion. Two procedural complications were limited to thromboembolic infarcts from in-stent thrombus and asymptomatic hemorrhagic infarct transformation (7% morbidity, 0% mortality). Angiographic and ultrasound follow-up confirmed normal carotid caliber and stent patency, with 2 cases of <20% in-stent stenosis. Early clinical improvement resulted in a mean discharge NIHSS score of 6, and 9/15 (60%) patients achieved a 90-day mRS of ≤2. CONCLUSIONS: Emergent stent reconstruction of long-segment and flow-limiting carotid dissections in acute ischemic stroke intervention is safe and effective, with favorable clinical outcomes, allowing successful thrombectomy, vessel salvage, restoration of cerebral perfusion, and/or prevention of recurrent thromboembolic stroke.


Assuntos
Dissecção Aórtica/cirurgia , Doenças das Artérias Carótidas/cirurgia , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Dissecção Aórtica/complicações , Doenças das Artérias Carótidas/complicações , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
12.
AJNR Am J Neuroradiol ; 36(11): 2121-6, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26294650

RESUMO

Foreign material emboli following cerebral, cardiac, and peripheral catheterizations have been reported since the mid-1990s. Catheter coatings have been frequently implicated. The most recent surge of interest in this phenomenon within the neurointerventional community is associated with procedures using flow-diversion devices for the treatment of cerebral aneurysms. Following coil-supported Pipeline embolization in 4 cases and stent-supported coiling in 1, 5 patients developed multiple subcentimeter enhancing lesions, usually with surrounding edema and variable magnetic susceptibility in the vascular territories of the treated aneurysms. Conventional angiography findings were unrevealing. Laboratory work-up showed mild CSF protein elevation with no leukocytosis. Brain biopsy in 2 cases revealed granulomatous angiitis encasing foreign material, identical in stain appearance to a polyvinylpyrrolidone catheter coating. Corticosteroid administration typically produced clinical improvement. A heterogeneous radiographic and clinical course was noted, with rise and fall in the number of enhancing lesions in 2 patients and persistence in others. The etiology may be related to widespread adoption of increasingly sophisticated catheterization techniques.


Assuntos
Embolização Terapêutica/efeitos adversos , Corpos Estranhos , Embolia Intracraniana/etiologia , Prótese Vascular/efeitos adversos , Catéteres/efeitos adversos , Embolização Terapêutica/instrumentação , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Radiografia , Stents/efeitos adversos
13.
J Am Assoc Lab Anim Sci ; 54(3): 286-90, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26045454

RESUMO

Simulators for neonatal intubation training have improved, prompting us to compare a state-of-the-art simulator with live ferrets for training novice family-medicine residents in this crucial skill. After a scripted didactic presentation, we used a crossover study design and randomly assigned residents to receive simulator or live ferret training, after which they repeated the procedure by using the opposite method. Participants were asked to report their level of confidence and competence before and after each training session and the usefulness of each training method. In addition, residents were videotaped performing the procedure and evaluated by using a modified global rating scale. The 2 methods did not differ in regard to self-reported confidence, competence, or usefulness of each training procedure. A majority of participants indicated that they preferred using the ferrets over the simulator, with realism cited most frequently as the reason for their choice. Videotape scores for time and motion and flow of the procedure were higher when the simulator was used, but higher for instrument handling when ferrets were intubated. Overall scores were higher for videotaped evaluations with the simulator compared with the ferrets. According to these findings, the simulator appears to provide adequate instruction for the initial training of novice learners in neonatal intubation techniques.


Assuntos
Educação em Veterinária , Furões , Intubação Intratraqueal/veterinária , Animais , Animais Recém-Nascidos , Competência Clínica , Simulação por Computador , Intubação Intratraqueal/métodos
14.
Acta Neurochir (Wien) ; 157(7): 1125-9; discussion 1130, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25981434

RESUMO

BACKGROUND: The use of minimally porous endoluminal devices (MPEDs) such as the Pipeline Embolization Device (PED) has been described for the treatment of brain aneurysms. The benefit of using MPEDs to assist embolization of a direct high-flow carotid cavernous fistula resulting from a ruptured cavernous carotid artery aneurysm is not well documented. METHODS: We describe our experience with deploying a tailored multidevice PED construct across the cavernous internal carotid artery (ICA) wall defect in combination with transarterial coil embolization using the "jailed microcatheter" technique. RESULTS: A 59-year-old woman presented with acute left-sided ophthalmoplegia. Diagnostic cerebral angiography demonstrated a ruptured giant cavernous carotid aneurysm with fistulous outflow via the ipsilateral left superior ophthalmic vein and into the pterygoid venous plexi bilaterally. Via the Marksman microcatheter, a total of three PEDs measuring 4.5 mm × 18 mm, 4.5 mm × 20 mm, and 4.75 mm × 16 mm were telescoped within the ICA across the aneurysm neck. Coiling of the aneurysm fundus and cavernous sinus via the "jailed" Rapidtransit microcatheter was subsequently achieved. A 2-year follow-up digital subtraction angiography (DSA) demonstrated stable obliteration of the aneurysm and the fistula, coincident with complete resolution of the patient's symptoms. CONCLUSIONS: Based on our long-term clinical and angiographic results, we advocate that the presented method be a valid treatment option for selected cases.


Assuntos
Prótese Vascular , Fístula Carótido-Cavernosa/cirurgia , Embolização Terapêutica/métodos , Dispositivos de Acesso Vascular , Aneurisma Roto/complicações , Aneurisma Roto/cirurgia , Fístula Carótido-Cavernosa/etiologia , Embolização Terapêutica/instrumentação , Feminino , Humanos , Pessoa de Meia-Idade
15.
AJNR Am J Neuroradiol ; 36(7): 1299-302, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25792531

RESUMO

BACKGROUND AND PURPOSE: Treatment options for nonsaccular posterior cerebral artery aneurysms include a range of surgical and endovascular reconstructive and deconstructive methods. However, no truly satisfactory treatment option is available to date for lesions arising from the P1 and P2 segments. The purpose of the present case series is to investigate both the efficacy and safety of the Pipeline Embolization Device in treating these challenging aneurysms. MATERIALS AND METHODS: We present a series of 6 consecutive patients who underwent endoluminal reconstruction with the Pipeline Embolization Device for nonsaccular P1 or P2 segment aneurysms between January 2009 and June 2013. RESULTS: Aneurysm location included the P1 segment in 2 patients and the P2 segment in 4 patients. Mean aneurysm diameter was 23 mm (range, 5-44 mm). Mean length of the arterial segment involved was 10 mm (range, 6-19 mm). Clinical presentation included mass effect in 4 patients and perforator stroke and subacute aneurysmal subarachnoid hemorrhage in 1 patient each. Endovascular reconstruction was performed by using 1 Pipeline Embolization Device in 5 patients and 2 overlapping Pipeline Embolization Devices in the remaining patient. Angiographic aneurysm occlusion was immediate in 1 patient, within 6 months in 4 patients, and within 1 year in the remaining patient. Index symptoms resolved in 4 patients and stabilized in the remaining 2. No new permanent neurologic sequelae and no aneurysm recurrence were recorded during the mean follow-up period of 613 days (range, 540-725 days). CONCLUSIONS: Endovascular reconstruction with the Pipeline Embolization Device for nonsaccular aneurysms arising from the P1 and P2 segments compares favorably with historical treatment options in terms of occlusion rate, margin of safety, and neurologic outcome.


Assuntos
Embolização Terapêutica/instrumentação , Procedimentos Endovasculares/instrumentação , Aneurisma Intracraniano/cirurgia , Adulto , Idoso , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Radiografia , Resultado do Tratamento
16.
AJNR Am J Neuroradiol ; 36(5): 937-42, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25572948

RESUMO

BACKGROUND AND PURPOSE: Endoluminal reconstruction with the Pipeline Embolization Device is an effective treatment option for select intracranial aneurysms. However, concerns for the patency of eloquent branch arteries covered by the Pipeline Embolization Device have been raised. We aimed to examine the patency of the anterior choroidal artery and clinical sequelae after ICA aneurysm treatment. MATERIALS AND METHODS: We prospectively analyzed all patients among our first 157 patients with ICA aneurysms treated by the Pipeline Embolization Device who required placement of at least 1 device across the ostium of the anterior choroidal artery. The primary outcome measure was angiographic patency of the anterior choroidal artery at last follow-up. Age, sex, type of aneurysm, neurologic examination data, number of Pipeline Embolization Devices used, relationship of the anterior choroidal artery to the aneurysm, and completeness of aneurysm occlusion on follow-up angiograms were also analyzed. RESULTS: Twenty-nine aneurysms requiring placement of at least 1 Pipeline Embolization Device (median = 1, range = 1-3) across the anterior choroidal artery ostium were identified. At angiographic follow-up (mean = 15.1 months; range = 12-39 months), the anterior choroidal artery remained patent, with antegrade flow in 28/29 aneurysms (96.5%), while 24/29 (82.7%) of the target aneurysms were angiographically occluded by 1-year follow-up angiography. Anterior choroidal artery occlusion, with retrograde reconstitution of the vessel, was noted in a single case. A significant correlation between the origin of the anterior choroidal artery from the aneurysm dome and failure of the aneurysms to occlude following treatment was found. CONCLUSIONS: After placement of 36 Pipeline Embolization Devices across 29 anterior choroidal arteries (median = 1 device, range = 1-3 devices), 1 of 29 anterior choroidal arteries was found occluded on angiographic follow-up. The vessel occlusion did not result in persistent clinical sequelae. Coverage of the anterior choroidal artery origin with the Pipeline Embolization Device, hence, may be considered reasonably safe when deemed necessary for aneurysm treatment.


Assuntos
Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Grau de Desobstrução Vascular , Adulto , Idoso , Angiografia Cerebral , Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/cirurgia , Embolização Terapêutica/instrumentação , Feminino , Seguimentos , Oclusão de Enxerto Vascular/epidemiologia , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
18.
J Am Soc Echocardiogr ; 26(10): 1221-1227, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23860097

RESUMO

BACKGROUND: Invasive studies have shown that children with Fontan palliation have abnormal arterial stiffness, impedance, and hydraulic power and efficiency. The aim of this study was to assess these indexes noninvasively in a cohort of children with Fontan circulation using Doppler echocardiography and compare their results with those of healthy peers. METHODS: This was a case-control study of 22 Fontan patients and 31 healthy control children. Using standard two-dimensional, M-mode, and Doppler echocardiographic imaging and carotid artery applanation tonometry, aortic flows, dimensions, and pulse-wave velocity were measured, and vascular impedance and arterial stiffness were calculated. Hydraulic power and efficiency were calculated from standard fluid dynamics formulae. RESULTS: The median age was similar between groups. Stroke volume index (39 vs 39 mL/min/m(2)) and cardiac index (2.6 vs 2.5 L/min/m(2)) were similar. Aortic cross-sectional area (3.3 vs 2.8 cm(2)), peak aortic flow (302 vs 261 cm(3)/sec), and myocardial performance index (0.47 vs 0.25) were higher and ejection fraction (50% vs 66%) was lower in Fontan patients. Input impedance (61 vs 83 dyne · sec/cm(5)/m(2)) was lower in Fontan patients. Pulse-wave velocity (488 vs 364 cm/sec), elastic pressure-strain modulus (305 vs 263 torr), and stiffness index (4.15 vs 3.04) were higher in Fontan patients. Total arterial compliance (1.29 vs 1.32 mL/torr/m(2)) and mean power (606 vs 527 mW/m(2)) were similar and total hydraulic power (716 vs 627 mW/m(2)) was higher in Fontan patients. Efficiency and the power cost per unit of forward flow were similar. CONCLUSIONS: Despite stiffer aortas, Fontan patients generate more hydraulic power associated with decreased ventricular function to achieve a similar hydraulic efficiency. In Fontan patients, therapy that is given to improve ventricular function may need to target vascular stiffness as well. This technique may be used to monitor the efficacy of therapeutic interventions.


Assuntos
Aorta/fisiologia , Técnica de Fontan , Rigidez Vascular/fisiologia , Adolescente , Artérias Carótidas/fisiopatologia , Estudos de Casos e Controles , Criança , Pré-Escolar , Ecocardiografia Doppler , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Manometria , Estudos Prospectivos , Fluxo Sanguíneo Regional , Função Ventricular
19.
Pediatr Cardiol ; 34(5): 1218-25, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23381174

RESUMO

Chronic kidney disease (CKD) is known to cause increased arterial stiffness, which is an important independent risk factor for adverse cardiovascular events. The purpose of this study was to assess the vascular properties of the aorta (AO) in a group of children with CKD using a noninvasive echocardiography (echo)-Doppler method. We studied 24 children with stages 2 through 5 CKD and 48 age-matched controls. Detailed echocardiographic assessment and echo-Doppler pulse wave velocity (PWV) was performed. Indices of arterial stiffness, including characteristic (Zc) and input (Zi) impedances, elastic pressure-strain modulus (Ep), and arterial wall stiffness index, were calculated. CKD patients underwent full nephrology assessment, and an iohexol glomerular filtration rate was performed, which allowed for accurate assignment of the CKD stage. CKD patients had greater median systolic blood pressure (114 vs. 110 mmHg; p < 0.04) and pulse pressure (51 vs. 40 mmHg; p < 0.001) compared with controls. PWV was similar between groups (358 vs. 344 cm s(-1); p = 0.759), whereas Zi (182 vs. 131 dyne s cm(-5); p < 0.001), Zc (146 vs. 138 dyne s cm(-5); p = 0.05), and Ep (280 vs. 230 mmHg; p < 0.02) were significantly greater in CKD than in controls. Although load-dependent measures of arterial stiffness were greater in non-dialysis dependent CKD patients, PWV was not increased compared with controls. This suggests that the increased arterial stiffness may not be permanent in these pediatric patients with kidney disease.


Assuntos
Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Ecocardiografia Doppler/métodos , Insuficiência Renal Crônica/fisiopatologia , Rigidez Vascular , Adolescente , Estudos de Casos e Controles , Criança , Pré-Escolar , Estudos Transversais , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco
20.
Respir Physiol Neurobiol ; 181(1): 8-13, 2012 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-22285797

RESUMO

The purpose of this study was to determine if healthy young women of various aerobic fitness levels are vulnerable to intrapulmonary arteriovenous shunts (IPAVS) at sub maximal work rates. Female volunteers (n=24) performed semi-recumbent cycling exercise to exhaustion and agitated saline contrast echocardiography was used to determine the presence of IPAVS at rest, during exercise, and post exercise. Subjects were classified as untrained (UT, n=8), moderately trained (MT, n=6) and highly trained (HT, n=10) based on their respective (V(O(2,peak)) (UT=35±5; MT=43±1 and HT = 50 ± 3 ml kg(-1) min(-1)). We found that the % (V(O(2,peak)) at IPAVS onset was not significantly different between women of varying fitness (P>0.05). The majority of individuals exhibited IPAVS during modest levels of exercise intensity. In conclusion, there is no association between aerobic capacity or exercise intensity at IPAVS onset in women performing semi-recumbent cycle exercise.


Assuntos
Anastomose Arteriovenosa/fisiologia , Exercício Físico/fisiologia , Coração/fisiologia , Pulmão/irrigação sanguínea , Pulmão/fisiologia , Aptidão Física/fisiologia , Adulto , Ecocardiografia , Teste de Esforço , Feminino , Humanos , Consumo de Oxigênio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...