Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 12171, 2024 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806547

RESUMO

Upon implanting tissue-engineered heart valves (TEHVs), blood-derived macrophages are believed to orchestrate the remodeling process. They initiate the immune response and mediate the remodeling of the TEHV, essential for the valve's functionality. The exact role of another macrophage type, the tissue-resident macrophages (TRMs), has not been yet elucidated even though they maintain the homeostasis of native tissues. Here, we characterized the response of hTRM-like cells in contact with a human tissue engineered matrix (hTEM). HTEMs comprised intracellular peptides with potentially immunogenic properties in their ECM proteome. Human iPSC-derived macrophages (iMφs) could represent hTRM-like cells in vitro and circumvent the scarcity of human donor material. iMφs were derived and after stimulation they demonstrated polarization towards non-/inflammatory states. Next, they responded with increased IL-6/IL-1ß secretion in separate 3/7-day cultures with longer production-time-hTEMs. We demonstrated that iMφs are a potential model for TRM-like cells for the assessment of hTEM immunocompatibility. They adopt distinct pro- and anti-inflammatory phenotypes, and both IL-6 and IL-1ß secretion depends on hTEM composition. IL-6 provided the highest sensitivity to measure iMφs pro-inflammatory response. This platform could facilitate the in vitro immunocompatibility assessment of hTEMs and thereby showcase a potential way to achieve safer clinical translation of TEHVs.


Assuntos
Células-Tronco Pluripotentes Induzidas , Macrófagos , Engenharia Tecidual , Humanos , Células-Tronco Pluripotentes Induzidas/citologia , Células-Tronco Pluripotentes Induzidas/imunologia , Engenharia Tecidual/métodos , Macrófagos/imunologia , Macrófagos/metabolismo , Interleucina-1beta/metabolismo , Interleucina-6/metabolismo , Células Cultivadas , Matriz Extracelular/metabolismo , Diferenciação Celular , Alicerces Teciduais/química
2.
Front Cardiovasc Med ; 9: 952178, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36176991

RESUMO

In situ heart valve tissue engineering approaches have been proposed as promising strategies to overcome the limitations of current heart valve replacements. Tissue engineered heart valves (TEHVs) generated from in vitro grown tissue engineered matrices (TEMs) aim at mimicking the microenvironmental cues from the extracellular matrix (ECM) to favor integration and remodeling of the implant. A key role of the ECM is to provide mechanical support to and attract host cells into the construct. Additionally, each ECM component plays a critical role in regulating cell adhesion, growth, migration, and differentiation potential. Importantly, the immune response to the implanted TEHV is also modulated biophysically via macrophage-ECM protein interactions. Therefore, the aim of this review is to summarize what is currently known about the interactions and signaling networks occurring between ECM proteins and macrophages, and how these interactions may impact the long-term in situ remodeling outcomes of TEMs. First, we provide an overview of in situ tissue engineering approaches and their clinical relevance, followed by a discussion on the fundamentals of the remodeling cascades. We then focus on the role of circulation-derived and resident tissue macrophages, with particular emphasis on the ramifications that ECM proteins and peptides may have in regulating the host immune response. Finally, the relevance of these findings for heart valve tissue engineering applications is discussed.

3.
Expert Rev Cardiovasc Ther ; 18(10): 681-696, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32791869

RESUMO

INTRODUCTION: The establishment of transcatheter aortic valve implantation (TAVI) has revolutionized the treatment of severe aortic stenosis. However, with TAVI being approved for low-risk patients, valve durability is becoming of central importance. Here, we summarize how tissue engineered heart valves (TEHVs) may provide a clinically-relevant durable valve replacement compatible with TAVI. AREAS COVERED: Since its introduction, TAVI prostheses have advanced in design and development. However, TAVI bioprostheses are based on fixed xenogeneic materials prone to progressive degeneration. Transcatheter TEHVs may have the potential to overcome the drawbacks of current TAVI bioprostheses, with their remodeling, self-repair, and growth capacities. So far, performance and remodeling of transcatheter TEHV with in-situ regenerative potential were demonstrated in the low-pressure system, with acute performance proved in the systemic circulation. However, several challenges remain to be solved to ensure a safe clinical translation of TEHVs for TAVI approaches. EXPERT OPINION: With TAVI rapidly evolving, the establishment of long-term valve durability represents the top priority to reduce the rate of patient re-interventions, remove the associated risks and adverse events, and improve patients' life quality worldwide. With long-term performance and remodeling proved, TEHVs may represent the next-generation technology for a life-long TAVI prosthesis.


Assuntos
Próteses Valvulares Cardíacas , Engenharia Tecidual , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Lab Chip ; 20(10): 1827-1844, 2020 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-32330215

RESUMO

Microfluidic organ-on-a-chip designs are used to mimic human tissues, including the vasculature. Here we present a novel microfluidic device that allows the interaction of endothelial cells (ECs) with pericytes and the extracellular matrix (ECM) in full bio-matrix encased 3D vessel structures (neovessels) that can be subjected to continuous, unidirectional flow and perfusion with circulating immune cells. We designed a polydimethylsiloxane (PDMS) device with a reservoir for a 3D fibrinogen gel with pericytes. Open channels were created for ECs to form a monolayer. Controlled, continuous, and unidirectional flow was introduced via a pump system while the design facilitated 3D confocal imaging. In this vessel-on-a-chip system, ECs interact with pericytes to create a human cell derived blood vessel which maintains a perfusable lumen for up to 7 days. Dextran diffusion verified endothelial barrier function while demonstrating the beneficial role of supporting pericytes. Increased permeability after thrombin stimulation showed the capacity of the neovessels to show natural vascular response. Perfusion of neovessels with circulating THP-1 cells demonstrated this system as a valuable platform for assessing interaction between the endothelium and immune cells in response to TNFα. In conclusion: we created a novel vascular microfluidic device that facilitates the fabrication of an array of parallel soft-channel structures in ECM gel that develop into biologically functional neovessels without hard-scaffold support. This model provides a unique tool to conduct live in vitro imaging of the human vasculature during perfusion with circulating cells to mimic (disease) environments in a highly systematic but freely configurable manner.


Assuntos
Células Endoteliais , Microfluídica , Comunicação Celular , Matriz Extracelular , Humanos , Dispositivos Lab-On-A-Chip
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...