Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Drug Deliv Transl Res ; 12(9): 2145-2156, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35691982

RESUMO

The identification of regulatory challenges for nanotechnology-enabled health products, followed by discussions with the involved stakeholders, is the first step towards a strategic planning of how such challenges can be successfully addressed in the future. In order to better understand whether the identified regulatory needs are sector-specific for health products or might also hinder the progress in other domains, the REFINE consortium reached out to communities representing other sectors that also exploit the potential of nanotechnology, i.e. industrial chemicals, food and cosmetics. Through a series of trans-sectorial workshops, REFINE partners identified common as well as sector-specific challenges and discussed possible ways forward. Potential solutions lie in a more strengthen collaboration between regulatory and research communities resulting in a targeted production and exploitation of academic data for the regulatory decision-making. Furthermore, a coordinated use of knowledge sharing platforms and databases, trans-sectorial standardisation activities and harmonisation of regulatory activities between geographical regions are possible ways forward, in line with the upcoming European political initiatives such as the Chemical Strategy for Sustainability (CSS). Finally, we also discuss the perspectives for further development and sustainability of methods and tools developed in the REFINE project.


Assuntos
Nanotecnologia
2.
Drug Deliv Transl Res ; 12(9): 2101-2113, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35538190

RESUMO

The application of nanomaterials in medicine has led to novel pharmaceuticals and medical devices that have demonstrated a strong potential for increasing the efficacy/performance and safety of therapeutic and diagnostic procedures to address a wide range of diseases. However, the successful translation of these technologies from their inception (proof-of-concept) to clinical practice has been challenged by substantial gaps in the scientific and technical capacity of R&D companies, especially SMEs, to keep up with the ever-evolving regulatory expectations in the emerging area of nanomedicine. To address these challenges, the EU Horizon 2020 project REFINE has developed a Decision Support System (DSS) to support developers of nanotechnology-enabled health products in bringing their products to the clinic. The REFINE DSS has been developed to support experts, innovators, and regulators in the implementation of intelligent testing strategies (ITS) for efficient preclinical assessment of nanotechnology-enabled health products. The DSS applies logical rules provided by REFINE experts which generate prioritized lists of assays to be performed (i.e. ITSs) for physicochemical characterisation and for immunotoxicological endpoints. The DSS has been tested against several case studies and was validated by internal project experts as well as external ones.


Assuntos
Nanomedicina , Nanoestruturas , Nanomedicina/métodos , Nanotecnologia/métodos
3.
Eur Radiol Exp ; 6(1): 3, 2022 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-35083595

RESUMO

BACKGROUND: A procedure for sentinel lymph node biopsy (SLNB) using superparamagnetic iron-oxide (SPIO) nanoparticles and intraoperative sentinel lymph node (SLN) detection was developed to overcome drawbacks associated with the current standard-of-care SLNB. However, residual SPIO nanoparticles can result in void artefacts at follow-up magnetic resonance imaging (MRI) scans. We present a grading protocol to quantitatively assess the severity of these artefacts and offer an option to minimise the impact of SPIO nanoparticles on diagnostic imaging. METHODS: Follow-up mammography and MRI of two patient groups after a magnetic SLNB were included in the study. They received a 2-mL subareolar dose of SPIO (high-dose, HD) or a 0.1-mL intratumoural dose of SPIO (low-dose, LD). Follow-up mammography and MRI after magnetic SLNB were acquired within 4 years after breast conserving surgery (BCS). Two radiologists with over 10-year experience in breast imaging assessed the images and analysed the void artefacts and their impact on diagnostic follow-up. RESULTS: A total of 19 patients were included (HD, n = 13; LD, n = 6). In the HD group, 9/13 patients displayed an artefact on T1-weighted images up to 3.6 years after the procedure, while no impact of the SPIO remnants was observed in the LD group. CONCLUSIONS: SLNB using a 2-mL subareolar dose of magnetic tracer in patients undergoing BCS resulted in residual artefacts in the breast in the majority of patients, which may hamper follow-up MRI. This can be avoided by using a 0.1-mL intratumoural dose.


Assuntos
Linfonodo Sentinela , Mama , Humanos , Imageamento por Ressonância Magnética , Mastectomia Segmentar , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Biópsia de Linfonodo Sentinela
4.
Oral Oncol ; 121: 105464, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34329868

RESUMO

OBJECTIVES: To assess the feasibility and merits of a complete magnetic approach for a sentinel lymph node biopsy (SLNB) procedure in oral cancer patients. MATERIALS AND METHODS: This study included ten oral cancer patients (stage cT1-T2N0M0) scheduled for elective neck dissection (END). Superparamagnetic iron oxide nanoparticles (SPIO) were administered peritumorally prior to surgery. A preoperative MRI was acquired to identify lymph nodes (LNs) with iron uptake. A magnetic detector was used to identify magnetic hotspots prior, during, and after the SLNB procedure. The resected sentinel LNs (SLNs) were evaluated using step-serial sectioning, and the neck dissection specimen was assessed by routine histopathological examination. A postoperative MRI was acquired to observe any residual iron. RESULTS: Of ten primary tumors, eight were located in the tongue, one floor-of-mouth (FOM), and one tongue-FOM transition. SPIO injections were experienced as painful by nine patients, two of whom developed a tongue swelling. In eight patients, magnetic SLNs were successfully detected and excised during the magnetic SLNB procedure. During the END procedure, additional magnetic SLNs were identified in three patients. Histopathology confirmed iron deposits in sinuses of excised SLNs. Three SLNs were harboring metastases, of which one was identified only during the END procedure. The END specimens revealed no further metastases. CONCLUSION: A complete magnetic SLNB procedure was successfully performed in eight of ten patients (80% success rate), therefore the procedure seems feasible. Recommendations for further investigation are made including: use of anesthetics, magnetic tracer volume, planning preoperative MRI, comparison to conventional technique and follow-up.


Assuntos
Nanopartículas Magnéticas de Óxido de Ferro , Neoplasias Bucais , Biópsia de Linfonodo Sentinela/métodos , Linfonodo Sentinela , Humanos , Neoplasias Bucais/diagnóstico por imagem , Neoplasias Bucais/cirurgia , Projetos Piloto , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia
5.
Med Phys ; 45(7): 3205-3213, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29782653

RESUMO

PURPOSE: Data-driven gating (DDG) approaches for positron emission tomography (PET) are interesting alternatives to conventional hardware-based gating methods. In DDG, the measured PET data themselves are utilized to calculate a respiratory signal, that is, subsequently used for gating purposes. The success of gating is then highly dependent on the statistical quality of the PET data. In this study, we investigate how this quality determines signal noise and thus motion resolution in clinical PET scans using a center-of-mass-based (COM) DDG approach, specifically with regard to motion management of target structures in future radiotherapy planning applications. METHODS: PET list mode datasets acquired in one bed position of 19 different radiotherapy patients undergoing pretreatment [18 F]FDG PET/CT or [18 F]FDG PET/MRI were included into this retrospective study. All scans were performed over a region with organs (myocardium, kidneys) or tumor lesions of high tracer uptake and under free breathing. Aside from the original list mode data, datasets with progressively decreasing PET statistics were generated. From these, COM DDG signals were derived for subsequent amplitude-based gating of the original list mode file. The apparent respiratory shift d from end-expiration to end-inspiration was determined from the gated images and expressed as a function of signal-to-noise ratio SNR of the determined gating signals. This relation was tested against additional 25 [18 F]FDG PET/MRI list mode datasets where high-precision MR navigator-like respiratory signals were available as reference signal for respiratory gating of PET data, and data from a dedicated thorax phantom scan. RESULTS: All original 19 high-quality list mode datasets demonstrated the same behavior in terms of motion resolution when reducing the amount of list mode events for DDG signal generation. Ratios and directions of respiratory shifts between end-respiratory gates and the respective nongated image were constant over all statistic levels. Motion resolution d/dmax could be modeled as d/dmax=1-e-1.52(SNR-1)0.52, with dmax as the actual respiratory shift. Determining dmax from d and SNR in the 25 test datasets and the phantom scan demonstrated no significant differences to the MR navigator-derived shift values and the predefined shift, respectively. CONCLUSIONS: The SNR can serve as a general metric to assess the success of COM-based DDG, even in different scanners and patients. The derived formula for motion resolution can be used to estimate the actual motion extent reasonably well in cases of limited PET raw data statistics. This may be of interest for individualized radiotherapy treatment planning procedures of target structures subjected to respiratory motion.


Assuntos
Movimento , Tomografia por Emissão de Pósitrons/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Razão Sinal-Ruído , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
6.
Phys Med ; 32(7): 926-31, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27257142

RESUMO

PURPOSE: The use of a magnetic nanoparticle tracer and handheld magnetometer for sentinel lymph node biopsy (SLNB) was recently introduced to overcome drawbacks associated with the use of radioisotope tracers. Unlike the gamma probe, the used magnetometers are not only sensitive to the tracer, but also the diamagnetic human body. This potentially limits the performance of the magnetometer when used clinically. METHODS: A phantom, mimicking the magnetic and mechanical properties of the human axilla, was constructed. The depth performance of two current generation magnetometers was evaluated in this phantom. LN-phantoms with tracer uptake ranging from 5 to 500µg iron were placed at clinically relevant depths of 2.5, 4 and 5.5cm. Distance-response curves were obtained to quantify the depth performance of the probes. RESULTS: The depth performance of both probes was limited. In the absence of diamagnetic material and forces on the probe (ideal conditions) a LN-phantom with high uptake (500µg iron) could first be detected at 3.75cm distance. In the phantom, only superficially placed LNs (2.5cm) with high uptake (500µg iron) could be detected from the surface. The penetration depth was insufficient to detect LNs with lower uptake, or which were located deeper. CONCLUSION: The detection distance of the current generation magnetometers is limited, and does not meet the demands formulated by the European Association for Nuclear Medicine for successful transcutaneous SLN localization. Future clinical trials should evaluate whether the limited depth sensitivity is of influence to the clinical outcome of the SLNB procedure.


Assuntos
Magnetometria/instrumentação , Imagens de Fantasmas , Biópsia de Linfonodo Sentinela/instrumentação , Humanos , Fenômenos Magnéticos
7.
Br J Radiol ; 88(1056): 20150634, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26492466

RESUMO

OBJECTIVE: Sentinel lymph node biopsy (SLNB) with a superparamagnetic iron oxide (SPIO) tracer was shown to be non-inferior to the standard combined technique in the SentiMAG Multicentre Trial. The MRI subprotocol of this trial aimed to develop a magnetic alternative for pre-operative lymphoscintigraphy (LS). We evaluated the feasibility of using MRI following the administration of magnetic tracer for pre-operative localization of sentinel lymph nodes (SLNs) and its potential for non-invasive identification of lymph node (LN) metastases. METHODS: Patients with breast cancer scheduled to undergo SLNB were recruited for pre-operative LS, single photon emission CT (SPECT)-CT and SPIO MRI. T1 weighted turbo spin echo and T2 weighted gradient echo sequences were used before and after interstitial injection of magnetic tracer into the breast. SLNs on MRI were defined as LNs with signal drop and direct lymphatic drainage from the injection site. LNs showing inhomogeneous SPIO uptake were classified as metastatic. During surgery, a handheld magnetometer was used for SLNB. Blue or radioactive nodes were also excised. The number of SLNs and MR assessment of metastatic involvement were compared with surgical and histological outcomes. RESULTS: 11 patients were recruited. SPIO MRI successfully identified SLNs in 10 of 11 patients vs 11 of 11 patients with LS/SPECT-CT. One patient had metastatic involvement of four LNs, and this was identified in one node on pre-operative MRI. CONCLUSION: SPIO MRI is a feasible technique for pre-operative localization of SLNs and, in combination with intraoperative use of a handheld magnetometer, provides an entirely radioisotope-free technique for SLNB. Further research is needed for the evaluation of MRI characterization of LN involvement using subcutaneous injection of magnetic tracer. ADVANCES IN KNOWLEDGE: This study is the first to demonstrate that an interstitially administered magnetic tracer can be used both for pre-operative imaging and intraoperative SLNB, with equal performance to imaging and localization with radioisotopes.


Assuntos
Neoplasias da Mama/patologia , Dextranos , Aumento da Imagem , Linfonodos/patologia , Imageamento por Ressonância Magnética , Nanopartículas de Magnetita , Cuidados Pré-Operatórios , Idoso , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Metástase Linfática , Pessoa de Meia-Idade , Biópsia de Linfonodo Sentinela
8.
Int J Nanomedicine ; 10: 1235-43, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25709445

RESUMO

INTRODUCTION: Breast cancer staging with sentinel lymph node biopsy relies on the use of radioisotopes, which limits the availability of the procedure worldwide. The use of a magnetic nanoparticle tracer and a handheld magnetometer provides a radiation-free alternative, which was recently evaluated in two clinical trials. The hydrodynamic particle size of the used magnetic tracer differs substantially from the radioisotope tracer and could therefore benefit from optimization. The aim of this study was to assess the performance of three different-sized magnetic nanoparticle tracers for sentinel lymph node biopsy within an in vivo porcine model. MATERIALS AND METHODS: Sentinel lymph node biopsy was performed within a validated porcine model using three magnetic nanoparticle tracers, approved for use in humans (ferumoxytol, with hydrodynamic diameter d H =32 nm; Sienna+(®), d H =59 nm; and ferumoxide, d H =111 nm), and a handheld magnetometer. Magnetometer counts (transcutaneous and ex vivo), iron quantification (vibrating sample magnetometry), and histopathological assessments were performed on all ex vivo nodes. RESULTS: Transcutaneous "hotspots" were present in 12/12 cases within 30 minutes of injection for the 59 nm tracer, compared to 7/12 for the 32 nm tracer and 8/12 for the 111 nm tracer, at the same time point. Ex vivo magnetometer counts were significantly greater for the 59 nm tracer than for the other tracers. Significantly more nodes per basin were excised for the 32 nm tracer compared to other tracers, indicating poor retention of the 32 nm tracer. Using the 59 nm tracer resulted in a significantly higher iron accumulation compared to the 32 nm tracer. CONCLUSION: The 59 nm tracer demonstrated rapid lymphatic uptake, retention in the first nodes reached, and accumulation in high concentration, making it the most suitable tracer for intraoperative sentinel lymph node localization.


Assuntos
Nanopartículas de Magnetita , Biópsia de Linfonodo Sentinela/métodos , Animais , Magnetometria , Tamanho da Partícula , Suínos
9.
Nanomedicine ; 11(4): 993-1002, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25680540

RESUMO

The magnetic technique for sentinel lymph node biopsy (SLNB) has been evaluated in several clinical trials. An in vivo porcine model was developed to optimise the magnetic technique by evaluating the effect of differing volume, concentration and time of injection of magnetic tracer. A total of 60 sentinel node procedures were undertaken. There was a significant correlation between magnetometer counts and iron content of excised sentinel lymph nodes (SLNs) (r=0.82; P<0.001). Total number of SLNs increased with increasing volumes of magnetic tracer (P<0.001). Transcutaneous magnetometer counts increased with increasing time from injection of magnetic tracer (P<0.0001), plateauing within 60min. Increasing concentration resulted in higher iron content of SLNs (P=0.006). Increasing magnetic tracer volume and injecting prior to surgery improve transcutaneous 'hotspot' identification but very high volumes, increase the number of nodes excised. FROM THE CLINICAL EDITOR: Sentinel lymph node biopsy (SLNB) is the standard of care for axillary staging of breast cancer patients. Although the current gold standard technique is the combined injection of technetium-labelled nanocolloid and blue dye into the breast, the magnetic technique, using superparamagnetic carboxydextran-coated iron oxide (SPIO), has also been demonstrated as a feasible alternative. In this article, the authors set up to study factors in order to optimize the magnetic tracers.


Assuntos
Meios de Contraste/farmacologia , Campos Magnéticos , Magnetometria/instrumentação , Magnetometria/métodos , Modelos Biológicos , Biópsia de Linfonodo Sentinela , Animais , Biópsia de Linfonodo Sentinela/instrumentação , Biópsia de Linfonodo Sentinela/métodos , Suínos
10.
Breast Cancer Res Treat ; 141(1): 33-42, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23954989

RESUMO

The standard for the treatment of early non-palpable breast cancers is wide local excision directed by wire-guided localization and sentinel lymph node biopsy (SLNB). This has drawbacks technically and due to reliance upon radioisotopes. We evaluated the use of a magnetic tracer for its localization capabilities and concurrent performance of SLNB using a handheld magnetometer in a porcine model as a novel alternative to the current standard. Ethical approval by the IRCAD Ethics Review Board, Strasbourg (France) was received. A magnetic tracer was injected in varying volumes (0.1-5 mL) subcutaneously into the areolar of the left and right 3rd inguinal mammary glands in 16 mini-pigs. After 4 h magnetometer counts were taken at the injection sites and in the groins. The magnetometer was used to localize any in vivo signal from the draining inguinal lymph nodes. Magnetic SLNB followed by excision of the injection site was performed. The iron content of sentinel lymph nodes (SLNs) were graded and quantified. All excised specimens were weighed and volumes were calculated. Univariate analyses were performed to evaluate correlation. Magnetic SLNB was successful in all mini-pigs. There was a significant correlation (r = 0.86; p < 0.01) between magnetometer counts and iron content of SLNs. Grading of SLNs on both H&E and Perl's staining correlated significantly with the iron content (p = 0.001; p = 0.003) and magnetometer counts (p < 0.001; p = 0.004). The peak counts corresponded to the original magnetic tracer injection sites 4 h after injection in all cases. The mean volume and weight of excised injection site specimens was 2.9 cm(3) (SD 0.81) and 3.1 g (SD 0.85), respectively. Injection of ≥0.5 mL magnetic tracer was associated with significantly greater volume (p = 0.05) and weight of excision specimens (p = 0.01). SLNB and localization can be performed in vivo using a magnetic tracer. This could provide a viable alternative for lesion localization and concurrent SLNB in the treatment of non-palpable breast cancer.


Assuntos
Meios de Contraste , Compostos Férricos , Linfonodos/química , Magnetismo , Glândulas Mamárias Animais/anatomia & histologia , Nanopartículas , Biópsia de Linfonodo Sentinela/métodos , Animais , Meios de Contraste/administração & dosagem , Avaliação Pré-Clínica de Medicamentos , Feminino , Compostos Férricos/administração & dosagem , Virilha , Injeções , Linfonodos/anatomia & histologia , Magnetismo/instrumentação , Nanopartículas/administração & dosagem , Corantes de Rosanilina , Biópsia de Linfonodo Sentinela/instrumentação , Suínos , Porco Miniatura , Distribuição Tecidual
11.
IEEE Trans Biomed Eng ; 60(9): 2594-602, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23674409

RESUMO

As the first step in developing a new clinical technique for the magnetic detection of colorectal sentinel lymph nodes (SLNs), a method is developed to measure the magnetic content in intact, formalin fixated lymph nodes using a vibrating sample magnetometer (VSM). A suspension of superparamagnetic nanoparticles is injected ex vivo around the tumor in the resected colon segments. A selection of three lymph nodes is excised from the region around the tumor and is separately measured in the VSM. The iron content in the lymph nodes is quantified from the magnetic moment curve using the Langevin model for superparamagnetism and a bimodal particle size distribution. Adverse, parasitic movements of the sample were successfully reduced by tight fixation of the soft tissue and using a small vibration amplitude. Iron content in the lymph nodes is detected with 0.5 µg accuracy and ranged from 1 to 51 µg. Histological staining confirmed iron presence. The current method of measuring intact biological tissue in a VSM is suitable to show the feasibility and merit of magnetic detection of SLNs in colorectal cancer. For clinical validation of magnetic SLN selection in colorectal cancer, a new magnetometer with high specificity for superparamagnetic nanoparticles is required.


Assuntos
Neoplasias Colorretais/química , Meios de Contraste/análise , Linfonodos/química , Nanopartículas de Magnetita/análise , Magnetometria/métodos , Biópsia de Linfonodo Sentinela/métodos , Neoplasias Colorretais/patologia , Meios de Contraste/química , Histocitoquímica , Humanos , Linfonodos/patologia , Metástase Linfática , Nanopartículas de Magnetita/química , Tamanho da Partícula , Vibração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...